Power Government Departments Closing in 0 days TDR #57899498

Tender For Conversion Of Existing 33Kv, 11Kv & Lt Oh Network To Ug Cabling System For Section-1(Gs Road) Within The Jurisdiction Of Guwahati-I Electrical Circle, Apdcl Under Distribution Infrastructure Works (Loss Reduction) Of Rev Ed Distribution Se

Issued by Government Departments · Kamrup Metro, Assam
Tender Value
184 Crore
Estimated cost
Bid Submission
28 Oct 2026
0 days left
EMD
3.68 Crore
Bank guarantee accepted
Document Fee
30000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kamrup Metro → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Conversion Of Existing 33Kv, 11Kv & Lt Oh Network To Ug Cabling System For Section-1(Gs Road) Within The Jurisdiction Of Guwahati-I Electrical Circle, Apdcl Under Distribution Infrastructure Works (Loss Reduction) Of Rev Ed Distribution Sector Scheme (Rdss)

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 15-Oct-2026 CORRIGENDUM NO 2 Technical Bid 28-Oct-2026
2 15-Oct-2026 BOQ CORRIGENDUM BOQ 28-Oct-2026

BOQ

Name of Work:- Conversion of Existing 33KV, 11kV & LT OH Network to UG Cabling System for Section-1(GS Road) within the jurisdiction of Guwahati-I Electrical Circle, APDCL under Distribution Infrastructure works (Loss Reduction) of Rev ed Distribution Sector Scheme (RDSS)
Sl. No. Item Description
1Please Enable Macros to View BoQ information
2Conversion of Existing 33KV, 11kV & LT OH Network to UG Cabling System for Section-1(GS Road) within the jurisdiction of Guwahati-I Electrical Circle, APDCL under Distribution Infrastructure works (Loss Reduction) of Revamped Distribution Sector Scheme (RDSS)
3Total Amount of Supply Price
4Total Amount of Installation/Erection charges
5Total of complete work
6Discount if any Offered by Bidder in %
7Conversion of Existing 33KV, 11kV & LT OH Network to UG Cabling System for Section-1(GS Road) within the jurisdiction of Guwahati-I Electrical Circle, APDCL under Distribution Infrastructure works (Loss Reduction) of Revamped Distribution Sector Scheme (RDSS)
8UG Cabling
9SCADA DMS
102.0 SUPPLY OF LINE MATERIALS :PART-A
11Supply of Type tested 33 kV, 1 Core, 630 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable (33KV class) with suitable Cable Jointing & Termination Kit for Straight Through,Indoor & Outdoor
12Supply of 33 kV, 1 Core, 630 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable
13Supply of Indoor Terminating Kit Heat Shrikable type suitable for 33 kV class, 1 Core, 630 mm²,Aluminium UG Cable along with all fitting accessories required.
14Supply of Outdoor Terminating Kit Heat Shrikable type suitable for 33 kV class, 1 Core, 630 mm²,Aluminium UG Cable along with all fitting accessories required.
15Supply of Heat Shrikable type Straight Through Jointing Kit for 33 kV, 1 Core, 630 mm², Aluminiumr UG Cable along with all fitting accessories required.
16Manadatory Spares : 33 kV, 1 Core, 630 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable (33KV class) with suitable Cable Jointing & Termination Kit for Straight Through,Indoor & Outdoor
17Supply of 33 kV, 1 Core, 630 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable (Manadatory Spares)
18Supply of Indoor Terminating Kit Heat Shrikable type suitable for 33 kV class, 1 Core, 630 mm²,Aluminium UG Cable along with all fitting accessories required. (Manadatory Spares)
19Supply of Outdoor Terminating Kit Heat Shrikable type suitable for 33 kV class, 1 Core, 630 mm²,Aluminium UG Cable along with all fitting accessories required. (Manadatory Spares)
20Supply of Heat Shrikable type Straight Through Jointing Kit for 33 kV, 1 Core, 630 mm², Aluminiumr UG Cable along with all fitting accessories required. (Manadatory Spares)
21Supply of 33kV Outdoor type,Compact,SF6-Gas insulated, 36kV class,expandable,motorised Ring Main Unit with LBS having individual FPI and VCB with Earth Switch & protective relay, individual metering unit for both LBS & VCB,with inbuilt FRTU compatible for Distribution SCADA/Automation
22Supply of 33kV 4-Way RMU with built in FRTU with 3 nos. Of LBS and 1 no. VCB of 630 Amp for 630 sqmm outgoing UG cable.
23Supply of 33kV 3-Way RMU with built in FRTU with 2 nos. of LBS and 1no. of VCB of 630 Amp for 630 sqmm outgoing UG cable.
24Supply of Type tested 11 kV, 3 Core, 400 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable (11KV class) with suitable Cable Jointing & Termination Kit for Straight Through,Indoor & Outdoor
25Supply of 11 kV, 3C, 400 mm², Aluminium, TR-XLPE armoured UG cable
26Supply of Heat Shrikable type Indoor Termination Kit for 11 kV, 3Core, 400 mm², aluminum UG Cable along with all fitting accessories required.
27Supply of Heat Shrikable type Outdoor Termination Kit for 11 kV, 3Core, 400 mm², aluminum UG Cable along with all fitting accessories required.
28Supply of Heat Shrikable type Straight Through Jointing Kit for 11 kV, 3Core, 400 mm², aluminum UG Cable along with all fitting accessories required.
29Manadatory Spares : 11 kV, 3 Core, 400 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable (11KV class) with suitable Cable Jointing & Termination Kit for Straight Through,Indoor & Outdoor
30Supply of 11 kV, 3C, 400 mm², Aluminium, TR-XLPE armoured UG cable (Manadatory Spares)
31Supply of Heat Shrikable type Indoor Termination Kit for 11 kV, 3Core, 400 mm², aluminum UG Cable along with all fitting accessories required. (Manadatory Spares)
32Supply of Heat Shrikable type Outdoor Termination Kit for 11 kV, 3Core, 400 mm², aluminum UG Cable along with all fitting accessories required. (Manadatory Spares)
33Supply of Heat Shrikable type Straight Through Jointing Kit for 11 kV, 3Core, 400 mm², aluminum UG Cable along with all fitting accessories required. (Manadatory Spares)
34Supply of 11kV Outddor type,Compact,SF6-Gas insulated,12kV class,expandable,motorised Ring Main Unit with LBS having individual FPI and VCB with Earth Switch & protective relay, for both LBS & VCB,with Inbuilt FRTU compatible for Distribution SCADA/Automation
35Supply of 11kV 5-Way RMU with built in FRTU with 3 nos. of LBS & 2 no. of VCB of 630 Amp for 400 sqmm main UG cable for substation connectivity for 400 sqmm loop UG cable
36Supply of 11kV 4-Way RMU with built in FRTU with 3 nos. of LBS & 1 no. of VCB of 630 Amp for 400 sqmm main UG cable for substation connectivity for 400 sqmm loop UG cable
37Supply of 11kV 3-Way RMU with built in FRTU with 2 nos. of LBS & 1 no. of VCB of 630 Amp for 400 sqmm main UG cable for substation connectivity for 400 sqmm loop UG cable
38Supply of Type tested 1.1 kV, 3.5 Core, 300 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable (1.1KV class) with suitable Cable Jointing & Termination Kit for Straight Through,Indoor & Outdoor
39Supply of 1.1kV, 3.5 Core, 300 mm², Al, TR-XLPE, armored UG Cable
40Supply of Heat Shrikable type Indoor Termination Kit for 1.1 kV, 3.5 Core, 300 mm², aluminum UG Cable along with all fitting accessories required.
41Supply of Heat Shrikable type Outdoor Termination Kit for 1.1 kV, 3.5 Core, 300 mm², aluminum UG Cable along with all fitting accessories required.
42Supply of Heat Shrikable type Straight Through Jointing Kit for 1.1 kV, 3.5 Core, 300 mm², aluminum UG Cable along with all fitting accessories required.
43Supply of 1.1kV, 3.5 Core, 35 mm², Al, XLPE, armored UG Cable for Street lighting
44Supply of assorted bi-metallic lug for 1.1kV, 3.5 Core, 35 mm², Al, XLPE, armored UG Cable.
45Manadatory Spares : 1.1 kV, 3.5 Core, 300 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable (1.1KV class) with suitable Cable Jointing & Termination Kit for Straight Through,Indoor & Outdoor
46Supply of 1.1kV, 3.5 Core, 300 mm², Al, TR-XLPE, armored UG Cable (Manadatory Spares)
47Supply of Heat Shrikable type Indoor Termination Kit for 1.1 kV, 3.5 Core, 300 mm², aluminum UG Cable along with all fitting accessories required. (Manadatory Spares)
48Supply of Heat Shrikable type Outdoor Termination Kit for 1.1 kV, 3.5 Core, 300 mm², aluminum UG Cable along with all fitting accessories required. (Manadatory Spares)
49Supply of Heat Shrikable type Straight Through Jointing Kit for 1.1 kV, 3.5 Core, 300 mm², aluminum UG Cable along with all fitting accessories required. (Manadatory Spares)
50Supply of 1.1kV, LT Feeder Pillar Box, Distribution Pillar Box and Service Pillar Box having Busbar (R,Y,B,N) for termination of 300 sqmm UG cable for connectivity. The entire unit need to be enclosed by Water proof, Fire proof, GI Steel sheet.
51Supply of 1.1kV, 5-Way LT Feeder Pillar Box having Busbar (R,Y,B,N) provision with 2 nos. of HRC Fuse of 400 Amp for Incoming feeder and 3 nos. of HRC Fuse of 250 Amp for Outgoing feeder termination of 300 sqmm UG cable.The entire unit need to be enclosed by Water proof, Fire proof, GI Steel sheet.
52Supply of 1.1kV, 5-Way LT Distribution Pillar Box having Busbar (R,Y,B,N) provision with 2 nos. of HRC Fuse of 400 Amp for Incoming feeder and 3 nos. of HRC Fuse of 250 Amp for Outgoing feeder termination of 300 sqmm UG cable.The entire unit need to be enclosed by Water proof, Fire proof, GI Steel sheet.
53Supply of outdoor floor-mounted 400A Fuse Junction Boxes, complete with enclosure, 400A incoming arrangement, 400A porcelain Kit Kat fuse arrangement, terminals, earthing and internal wiring, suitable for installation in the distribution network
54Supply of outdoor floor-mounted 100A Fuse Junction Boxes, complete with enclosure, 100A incoming arrangement, 400A porcelain Kit Kat fuse arrangement, terminals, earthing and internal wiring, suitable for installation in the distribution network for street lights
55Supply of 1.1kV, 7-Way LT Service Pillar Box having Busbar (R,Y,B,N) provision with 1 no. of HRC Fuse of 250 Amp for Incoming feeder and 5 nos. of Kit-Kat Fuse of 63 Amp for Outgoing feeder termination of 300 sqmm UG cable.The entire unit need to be enclosed by Water proof, Fire proof, GI Steel sheet.
56Supply of PE 80- PN8, HDPE Pipe for cable laying
57Supply of 250 mm dia PE 80- PN8, HDPE Pipe for 33kV cable laying
58Supply of 160 mm dia PE 80- PN8, HDPE Pipe for 11kV cable laying
59Supply of 110 mm dia PE 80- PN8, HDPE Pipe for LT Cable laying
60Supply of 63/50mm PLB(HDPE) pipe for LT Cable laying for street lights
61Supply of Hardware Fittings for Cable Hoisting
62Supply of Hardware Fittings for Cable Hoisting
63Supply of Earthing Materials
64Supply of GI earthing pipe 50mm dia 3m length 3.15mm thickness with preforated holes of 15mm dia at 30cm interval along the length of the pipe
65Supply of 8 SWG (Standard Wire Gauge) Galvanized Iron (GI) wire for earthing is a 4.00 mm (0.157 inch) diameter, zinc-coated steel wire designed for corrosion resistance, typically conforming to IS:280-2006 (or newer). It offers high tensile strength (350-550 N/mm^2) and is used for electrical grounding.
66Supply of 12 core Fiber,single mode, duct type, fibre armoured Optic Cable along with PLB Duct,Straight Through Connector & FO End Connector.
67Supply of 12 core, single mode, duct type, fibre armoured Optical Fiber Cable laid along 33kV & 11kV UG cable
68Supply of HDPE PLB Duct of size 32/26mm for laying of Optical Fiber Cable
69Supply of 160 mm dia PE 80- PN8, HDPE Pipe for communication cables
70Supply of Straight Through Connectors (Plastic Coupler) and acessories for OFC connection
71Supply of End Connectors and acessories for OFC connection at RMUs & SS end
72Supply of Van Mounted Cable Fault Locating Equipment with Mounting arrangement
73Supply of Van Mounted Cable Fault Locating Equipment with Mounting arrangement & having 1 set - Pre-Wiring, 1 Set - Control Unit, 1 set - Surge Generator, 1 set - Cable Fault Locator, 1 set - Cable Identifier, 2 set - Pinpointing Unit, 1 set - Route Tracing Unit, 1 set - DC HV Testing Unit, 1 set - Fault Conditioning & Fault Burring Unit, 1 set - Cable, 1 set - DG Unit, 1 set - Safety Module, 1 No. - Mounting Van for Comprehensive set with all necessary advance set-up.
74Supply of Portable cable test and fault location systemon low and medium voltage power cables
75Supply of Portable cable test and fault location system on low and medium voltage power cables
76Supply of armoured UG cable service Mains inside pipes from the L.T. Feeder pillar boxes to individual consumer installations (Average length of each service main 30mtr )
77Supply of 2 core x 10 sq mm PVC insulated UG armoured cable to be laid by open trench method and vertical wall run to the consumer energy meter. Average length of each service main 30mtr. (Single phase Consumers-1275nos)
78Supply of 4 core x 10 sq mm PVC insulated UG cable to be laid by open trench method and vertical wall run to the consumer energy meter. Average length of each service main 30mtr..(3 phase Consumers-750 nos)
79Supply of 4 core x 16 sq mm PVC insulated UG cable to be laid by open trench method and vertical wall run to the consumer energy meter. Average length of each service main 30mtr..(3 phase Consumers- 375 nos)
80Supply of 4 core x 25 sq mm PVC insulated UG cable to be laid by open trench method and vertical wall run to the consumer energy meter. Average length of each service main 30mtr..(3 phase Consumers- 150 nos)
81Supply of 63/50mm PLB(HDPE) pipe for LT service cable laying of individual consumers
82Supply of 110/96mm PLB (HDPE) pipe for LT service cable laying of group of consumers
83Supply of Service main Cable Accessories for above sized cables
84Supply of Clamps-8 nos/ one service main 1phase-4
85Supply of Terminal Connector-4 nos/ one service main 1phase consumer
86Supply of Terminal conectors for 10 sq mm PVC insulated UG cable 3phase-8 ERECTION OF FOLLOWING EQUIPMENT & MATERIALS(As per Technical Specification) ELECTRICAL WORKS (PART-A)
87Laying, Comissioning & Testing of Type tested 33 kV, 1 Core, 630 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable (33KV class) with suitable Cable Jointing & Termination Kit for Straight Through,Indoor & Outdoor at other Utilities or Private properties.
8833 kV, 1 Core, 630 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable via Direct Burried Method as per approved scheme
8933 kV, 1 Core, 630 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable 1 Runs through HDPE pipe by Open Trench method, as per approved scheme
9033 kV, 1 Core, 630 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable 1 Runs through HDPE pipe by HDD method, as per approved scheme
91Erection, Testing & Commissioning of Indoor Terminating Kit Heat Shrikable type suitable for 33 kV class, 1 Core, 630 mm²,Aluminium UG Cable
92Erection, Testing & Commissioning of Outdoor Terminating Kit Heat Shrikable type suitable for 33 kV class, 1 Core, 630 mm²,Aluminium UG Cable
93Erection, Testing & Commissioning of Heat Shrikable type Straight Through Jointing Kit for 33 kV, 1Core, 630 mm²,Aluminiumr UG Cable
94Restoration charges in Public & Private premises.
95Erection, Testing & Commissioning of 33kV Outdoor type,Compact,SF6-Gas insulated,36kV class,expandable,motorised Ring Main Unit with LBS having individual FPI and VCB with Earth Switch & protective relay,individual metering unit for both LBS & VCB,with Inbuilt FRTU compatible for Distribution SCADA/Automation
96Erection, Testing & Commissioning of 33kV 4-Way RMU with built in FRTU with 4 nos. VCB of 630 Amp for 630 sqmm outgoing UG cable.
97Erection, Testing & Commissioning of 33kV 3-Way RMU with built in FRTU with 3 nos. VCB of 630 Amp for 630 sqmm outgoing UG cable.
98Laying, Comissioning & Testing of 11 kV, 3 Core, 400 mm² Aluminium, TR-XLPE insulation UG Cable including Erection of suitable Cable Jointing Kit & Termination Kit and restoration at other Utilities or Private properties.
9911 kV, 3 Core, 400 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable via Direct Buried Method as per approved scheme
10011 kV, 3 Core, 400 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable 1 Runs through HDPE pipe by Open Trench method, as per approved scheme
10111 kV, 3 Core, 400 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable 1 Runs through HDPE pipe by HDD Method, as per approved scheme
102Erection, Testing & Commissioning of Heat Shrikable type Indoor Termination Kit for 11 kV, 3Core, 400 mm², aluminum UG Cable for termination
103Erection, Testing & Commissioning of Heat Shrikable type Outdoor Termination Kit for 11 kV, 3Core, 400 mm², aluminum UG Cable for termination
104Erection, Testing & Commissioning of Heat Shrikable type Straight Through Jointing Kit for 11 kV, 3Core, 400 mm², aluminum UG Cable
105Restoration charges in Public & Private premises.
106Erection, Testing & Commissioning of 11kV Outddor type,Compact,SF6-Gas insulated,12kV class,expandable,motorised Ring Main Unit with LBS having individual FPI and VCB with Earth Switch & protective relay,individual metering unit for both LBS & VCB,with Inbuilt FRTU compatible for Distribution SCADA/Automation
107Erection, Testing & Commissioning of 11kV 5-Way RMU with built in FRTU with 2 nos. of LBS & 3 no. of VCB of 630 Amp for 400 sqmm main UG cable for substation connectivity for 400 sqmm loop UG cable
108Erection, Testing & Commissioning of 11kV 4-Way RMU with built in FRTU with 3 nos. of VCB & 1 no. of LBS of 630 Amp for 400 sqmm main UG cable for substation connectivity for 400 sqmm loop UG cable
109Erection, Testing & Commissioning of 11kV 3-Way RMU with built in FRTU with 2 nos. of LBS & 1 no. of VCB of 630 Amp for 400 sqmm main UG cable for substation connectivity for 400 sqmm loop UG cable
110Laying, Comissioning & Testing of 1.1 kV, 3.5 Core,1-Run, 300 mm² Aluminium, TR-XLPE insulation UG Cable including Erection of suitable Cable Jointing Kit & Termination Kit and restoration at other Utilities or Private properties.
1111.1 kV, 3.5 Core, 300 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable 1 Runs through Open Trench method, as per approved scheme
1121.1 kV, 3.5 Core, 300 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable 1 Runs through HDPE pipe by Open Trench method, as per approved scheme
113Erection, Testing & Commissioning of Heat Shrikable type Indoor Termination Kit for 1.1 kV, 3.5Core, 300 mm², aluminum UG Cable for termination
114Erection, Testing & Commissioning of Heat Shrikable type Outdoor Termination Kit for 1.1 kV, 3.5Core, 300 mm², aluminum UG Cable for termination
115Erection, Testing & Commissioning of Heat Shrikable type Straight Through Jointing Kit for 1.1 kV, 3.5 Core, 300 mm², aluminum UG Cable
1161.1kV, 3.5 Core, 35 mm², Al, XLPE, armored UG Cable for Street lights Runs through Open Trench method, as per approved scheme along with installation of bimetallic lugs for termination wherever required
117Erection, Testing & Commissioning of 1.1kV, LT Feeder Pillar Box having Busbar (R,Y,B,N) for termination of 300 sqmm UG cable for connectivity. The entire unit need to be enclosed by Water proof, Fire proof, GI Steel sheet.
118Erection, Testing & Commissioning of 1.1kV, 5-Way LT Feeder Pillar Box having Busbar (R,Y,B,N) provision with 2 nos. of HRC Fuse of 400 Amp for Incoming feeder and 3 nos. of HRC Fuse of 250 Amp for Outgoing feeder termination of 300 sqmm UG cable for connectivity between DT and FPB.The entire unit need to be enclosed by Water proof, Fire proof, GI Steel sheet.
119Erection, Testing & Commissioning of 1.1kV, 5-Way LT Distribution Pillar Box having Busbar (R,Y,B,N) provision with 2 nos. of HRC Fuse of 400 Amp for Incoming feeder and 3 nos. of HRC Fuse of 250 Amp for Outgoing feeder termination of 300 sqmm UG cable.The entire unit need to be enclosed by Water proof, Fire proof, GI Steel sheet.
120Erection, Testing & Commissioning of outdoor floor-mounted 400A Fuse Junction Boxes, complete with enclosure, 400A incoming arrangement, 400A porcelain Kit Kat fuse arrangement, terminals, earthing and internal wiring, suitable for installation in the distribution network
121Erection, Testing & Commissioning of outdoor floor-mounted 100A Fuse Junction Boxes, complete with enclosure, 100A incoming arrangement, 400A porcelain Kit Kat fuse arrangement, terminals, earthing and internal wiring, suitable for installation in the distribution network for street lights
122Erection, Testing & Commissioning of 1.1kV, 7-Way LT Service Pillar Box having Busbar (R,Y,B,N) provision with FOR 400 A, 433 V AC with Rewirable (Kit-Kat) Fuses (5 Outgoings) for Outgoing feeder termination of 300 sqmm UG cable.The entire unit need to be enclosed by Water proof, Fire proof, GI Steel sheet.
123Erection, Testing & Commissioning of 80- PN8, HDPE Pipe for Cable laying
124Erection, Testing & Commissioning of 250 mm dia PE 80- PN8, HDPE Pipe for 33kV and 11kV cable laying
125Erection, Testing & Commissioning of 160 mm dia PE 80- PN8, HDPE Pipe for 33kV and 11kV cable laying
126Erection, Testing & Commissioning of 110 mm dia PE 80- PN8, HDPE Pipe for LT Cable laying
127Erection, Testing & Commissioning of 63/50mm PLB(HDPE) pipe for LT Cable laying for street lights
128Erection, Testing & Commissioning of Hardware Fittings for Cable Hoisting
129Erection, Testing & Commissioning of Hardware Fittings for Cable Hoisting
130Erection of Earthing Materials
131Erection, Testing & Commissioning of GI earting pipe 50mm dia 3m length 3.15mm thickness with preforated holes of 15mm dia at 30cm interval along the length of the pipe
132Erection, Testing & Commisioning of 8 SWG (Standard Wire Gauge) Galvanized Iron (GI) wire for earthing is a 4.00 mm (0.157 inch) diameter, zinc-coated steel wire designed for corrosion resistance, typically conforming to IS:280-2006 (or newer). It offers high tensile strength (350-550 N/mm^2) and is used for electrical grounding.
133Laying, Commissioning & Testing of 12 core,Single mode Fibre Optic cables through PLB duct including erection of St. through Connector & End Connector
134Laying,Commissioning & Testing of 12 core Single mode Fibre Optic cables through PLB Duct laid along 33 kV & 11kV UG cable in existing RCC Cable trench as per instruction of Engg. Incharge
135Laying of Communication Cables through HDPE pipes laid along LT UG cable alongside existing RCC cable trench as per instruction of Engineer In Charge
136Erection,Commissioning & Testing of Straight Through Connectors (Plastic Coupler) and acessories for OFC connection
137Erection, Testing & Commissioning of End Connectors and acessories for OFC connection at RMUs & SS end CIVIL WORKS (PART-B) Civil works for laying of 33kV, 11kV & LT cable (as per the designed cable route) in existing open cable trench
138Civil works for laying of 33kV, 11kV & LT cable (as per the designed cable route) in existing open cable trench by Executing Agency/APDCL
139Excavation along the road and tunneling under drain for cable crossing along with back-filling, for laying of 33kV, 11kV & LT cable (as per the designed cable route) in existing open cable trench of ((W) 800mm X (D)1605mm)
140Excavation along the road and tunneling under drain for cable crossing along with back-filling, for laying of 33kV, 11kV & LT cable (as per the designed cable route) in existing open cable trench of ((W)1200mmX (D)1605mm)
141Excavation along the road and tunneling under drain for cable crossing along with back-filling, for laying of 33kV, 11kV & LT cable (as per the designed cable route) in existing open cable trench of ((W)1200mm X (D)1980mm)
142Excavation along the road and tunneling under drain for cable crossing along with back-filling, for laying of 11kV & LT cable (as per the designed cable route) in existing open cable trench of ((W)800mm X (D)1230mm)
143Excavation along the road and tunneling under drain for cable crossing along with back-filling, for laying of LT cable (as per the designed cable route) in existing open cable trench of ((W)800mm X (D)855mm)
144Supply and Erection of Equipment Foundation with all accessories
145Supply & Erection of RCC Foundation of 0.6m for 3-Way 33kV RMU with built in FRTU including supply of all materials, Excavation of soil,Shifting of soil etc(M-25 Grade)
146Supply & Erection of RCC Foundation of 1m for 3-Way 33kV RMU with built in FRTU including supply of all materials, Excavation of soil,Shifting of soil etc(M-25 Grade)
147Supply & Erection of RCC Foundation of 0.6m for 4-Way 33kV RMU with built in FRTU including supply of all materials, Excavation of soil,Shifting of soil etc(M-25 Grade)
148Supply & Erection of RCC Foundation of 1m for 4-Way 33kV RMU with built in FRTU including supply of all materials, Excavation of soil,Shifting of soil etc(M-25 Grade)
149Supply & Erection of RCC Foundation of 0.6m for 3-Way 11kV RMU with built in FRTU including supply of all materials, Excavation of soil,Shifting of soil etc(M-25 Grade)
150Supply & Erection of RCC Foundation of 1m for 3-Way 11kV RMU with built in FRTU including supply of all materials, Excavation of soil,Shifting of soil etc(M-25 Grade)
151Supply & Erection of RCC Foundation of 0.6m for 4-Way 11kV RMU with built in FRTU including supply of all materials, Excavation of soil,Shifting of soil etc(M-25 Grade)
152Supply & Erection of RCC Foundation of 1m for 4-Way 11kV RMU with built in FRTU including supply of all materials, Excavation of soil,Shifting of soil etc(M-25 Grade)
153Supply & Erection of RCC Foundation of 0.6m for 5-Way 11kV RMU with built in FRTU including supply of all materials, Excavation of soil,Shifting of soil etc(M-25 Grade)
154Supply & Erection of RCC Foundation of 1m for 5-Way 11kV RMU with built in FRTU including supply of all materials, Excavation of soil,Shifting of soil etc(M-25 Grade)
155Supply & Erection of RCC Foundation of 0.6m for 5 Way LT FPB/DPB ncluding supply of all materials, Excavation of soil,Shifting of soil etc(M-25 Grade)
156Supply & Erection of RCC Foundation of 1m for 5 Way LT FPB/DPB ncluding supply of all materials, Excavation of soil,Shifting of soil etc(M-25 Grade)
157Supply & Erection of RCC Foundation of 0.6m for 7 Way LT SPB including supply of all materials, Excavation of soil,Shifting of soil etc (M-25 Grade)
158Supply & Erection of RCC Foundation of 1m for 7 Way LT SPB including supply of all materials, Excavation of soil,Shifting of soil etc (M-25 Grade)
159Supply & Erection of RCC Foundation of 0.6m for 400 A Fuse Junction Boxes including supply of all materials, Excavation of soil,Shifting of soil etc (M-25 Grade)
160Supply & Erection of RCC Foundation of 0.6m for 100 A Fuse Junction Boxes including supply of all materials, Excavation of soil,Shifting of soil etc (M-25 Grade)
161Supply & Erection of Double Pole Structure Equipment Foundation with all accessories
162Supply & Erection of Double Pole Structure Equipment Foundation with all accessories (ISMB & ISMC Steel Structure considered)
163Supply & Erection of Double Pole Structure Equipment Foundation with all accessories (For 33kV UG to OH Structure)
164Supply & Erection of Double Pole Structure Equipment Foundation with all accessories (For 11kV UG to OH Structure)
165Civil work for Route Marking & Cable Crossing
166Supply & Erection of Cable Route Markers at an interval of 100 mtrs.
167Supply & Erection of Cable Bridge
168Supply & Erection of Cable Bridge made of Galvanised Iron for 33kV, 11kV cable for crossing of water body (per square meter weighs 1Quintal). 11 number of cable bridge are required in Section-1(GS Road)
169Supply & Erection of Cable Bridge Foundation
170Dismantling of Existing Assets
171Dismantling of 33kV, 11kV & LT line conductor/cable along with pole, X-arm, etc. & returning to store
172Laying,Commissioning and testing of UG cable service Mains inside pipes from the L.T. Feeder pillar boxes to individual consumer installations (Average length of each service main 30mtr )
173Laying of 2 core/ 4 core x 10/16/25 sq mm PVC insulated UG cable to be laid by open trench method with PLB (HDPE) duct and vertical wall run to the consumer energy meter, Average length of each service main 30mtr.
174Laying of 63/50 mm PLB (HDPE) pipe for individual consumers
175Laying of 110/96 mm PLB(HDPE) pipe for group of consumers
176Laying of 110/96 mm PLB (HDPE) pipe for group of consumers in microtunneling
177Excavation, Sand Bedding, Brick Padding & Backfilling (300 mm wide trench, 600 mm deep) of total cable
178Erection of Service main Cable Accessories
179Erection of Clamps-8 nos for one service main
180Erection of Terminal conectors 4 nos for one service main
181Erection of Terminal conectors 8 nos for one service main
182Statutory charges
183Statutory charges (against the charges towards GMC, PHED etc.) including inspection charges (Lumpsum)
184Capacity Building Charges
185Capacity Building and Training for Employer for smooth operation & maintanance of the entire UG network for 1 year from the takeover of the first Section.
186Hardware for Control Centre As per TS
187SCADA Server
188DMS Server
189OMS Server
190ISR server
191NMS server
192DTS server
193Developmental server
194Commnuication Server
195Web/Directory server
196Workstation with dual TFT Monitors ( S/S monitoring)
197Workstation with dual TFT Monitors (Network monitoring)
198Remote VDUs with one TFT Monitors
199Developmental console with one TFT
200DTS/Workstation Console with dual TFTs
201DLP/ LED based Video Projection system with 3x4 Module configuration with each module at least 67\\" diagonal with common projector
202Storage & Backup Devices
203External RAID Mass storage device ( for 24 months online backup)
204External DAT drive
205Switches
206Layer II switch (SCADA/DMS LAN)
207Layer II switch ( Planning & Development system LAN)
208Routers
209Router for interfacing IT system & SCADA/DMS DR centre
210Router at remote VDU
211Security system (DMZ)
212Web server with load balancing
213Mail server
214Router
215Firewall & network IDS/IPS
216Layer II switch
217Other Active Devices
218GPS Time synchronisation system
219Time, day & date digital displays
220Printers
221Color inkjet printer
222B/W Laser printer
223Software For Control Center
224SCADA software
225ISR Software
226DMS software
227DTS software
228Developmental software
229Network Management Software
230WEB /Network security software
231RDBMS package
232GIS Adaptor/Engine for importing data from GIS system under IT system
233Manadatory Spares
234Mandatory Spares
235Hardware For DR Center As per TS
236DR Server
237Commnuication Server
238Workstation with single TFT Monitor
239Storage & Backup Devices
240External RAID Mass storage device ( for24 months online backup)
241External DAT drive
242Switches
243Layer II switch (SCADA/DMS LAN)
244Routers
245Router for interfacing IT system & SCADA/DMS DR centre
246Other Active Devices
247GPS Time synchronisation system
248Time, day & date digital displays
249Software For DR Center As per TS
250SCADA software
251Mandatory Spares
252Manadatory Spares
253Mandatory Spares
254RTU base equipment comprising panels, racks, sub-racks, Power Supply modules, CPU, interfacing equipment, required converters & all other required items/accessories including complete wiring for all modules for locations mentioned at Vol Vi (Should be compatible for IEC 62056 along with other protocols metioned in SBD)
255Multifunctional transducers
256Contact Multiplying Relays (CMRs)
257Heavy duty relays for Control
258Dummy Breaker Latching Relays
259Transformer Transducers
260Single TFT PC for LDMS with OS
261DC Current Transducer
262DC Voltage Transducer
263AC Voltage Transducer
264OTI and WTI Temperature Indicator
265ACDB with sufficient MCBs
266Ethernet Switchs 24 Ports for Relay Networking
267Weather transducer - Wind speed
268Weather transducer - Rainfall
269Weather transducer - Humidity
270Weather transducer -Temperature
271Weather transducer -Wind Direction
272TEST EQUIPMENTS for RTU
273RTU Database Configuration & Maintenance Software tool
274Master Station cum RTU Simulator & Protocol analyser software tool
275Laptop PC for above software tools along with interfacing hardware including Hub
276Manadatory Spares
277Mandatory Spares
278Test Equipments for FRTU
279FRTU Database Configuration & Maintenance Software tool
280Master Station cum FRTU Simulator & Protocol analyser software tool
281Laptop PC for above software tools along with interfacing hardware including Hub
282Dual redundant link Network Connectivity Charge for 100MbPS Link at CC
283Dual redundant link Network Connectivity Charge for 100MbPS Link at DR
284Dual redundant link Network Connectivity Charge for 2 MbPS Link at SS
285Dual redundant link Network connectivity from CC to optic fiber WAN/LAN (Field devices )
286MPLS Router
287Dual redundant link Network Connectivity Charge (GPRS) 5G Link for Field devices as RVDU, FRTU
288Modems
289Manadatory Spares
290Mandatory Spares
291Main Equipments - DR Centre
292UPS with suitable rating running in parallel redundant mode*
293For RTU / Data Concentrator / Communication Eqpts.
294DC Power Supply (DCPS) system based on SMPS
2952 kVA online UPS for RTU Locations with VRLA Batteries to give 4 hrs back up
296Remote VDU location
297UPS (2 kVA )
298Manadatory Spares
299Mandatory Spares
300Facility Managament Services for 5 Years after GO-LIVE

AI Tender Summary

OUR REF NO 57899498
AUTHORITY Government Departments
TENDER VALUE 184 Crore
LAST DATE 28-10-2026
Authority
Authority Name Assam Power Distribution Company Limited
Work Description Tender for Conversion Of Existing 33Kv, 11Kv & Lt Oh Network To Ug Cabling System For Section-1(Gs Road) Within The Jurisdiction Of Guwahati-I Electrical Circle, Apdcl Under Distribution Infrastructure Works (Loss Reduction) Of Rev Ed Distribution Sector Scheme (Rdss)
Basic Detail
Tender No APDCL/CGM(PPD)/RDSS/GCUC-UG Cabling/26-27
Bidding Type Tender
Location
City Kamrup Metro
State Assam
Key Dates
Publish Date 15 Oct 2026
Submission Date 28 Oct 2026
Open Date 01 Jan 0001
Finance
Tender Value 184 Crore
Tender Fee 30000
EMD 3.68 Crore
Exemption Available
Document List
BOQ_85260.xls
ed7e6c81-b47b-4377-8668-6ef05236a0f2.html
GCCANDSCCSCADA.pdf
IFBPART1.pdf
IFBPART2A.pdf
IFBPART2B.pdf
IFBPART2BSCADA.pdf
IFBPART3.pdf
REQUIREDDRAWING.rar
ROUTEMAPUG.rar
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 28, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Today
Oct 28, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Today
Oct 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today

Tender Documents

Download All (ZIP) ↓
xls

BOQ_85260.xls

html

ed7e6c81-b47b-4377-8668-6ef05236a0f2.html

pdf

GCCANDSCCSCADA.pdf

pdf

IFBPART1.pdf

pdf

IFBPART2A.pdf

pdf

IFBPART2B.pdf

pdf

IFBPART2BSCADA.pdf

pdf

IFBPART3.pdf

rar

REQUIREDDRAWING.rar

rar

ROUTEMAPUG.rar

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender