Tender For Conversion Of Existing 33Kv, 11Kv & Lt Oh Network To Ug Cabling System For Section-1(Gs Road) Within The Jurisdiction Of Guwahati-I Electrical Circle, Apdcl Under Distribution Infrastructure Works (Loss Reduction) Of Rev Ed Distribution Se
Tender Overview
Project Description
Tender for Conversion Of Existing 33Kv, 11Kv & Lt Oh Network To Ug Cabling System For Section-1(Gs Road) Within The Jurisdiction Of Guwahati-I Electrical Circle, Apdcl Under Distribution Infrastructure Works (Loss Reduction) Of Rev Ed Distribution Sector Scheme (Rdss)
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 15-Oct-2026 | CORRIGENDUM NO 2 | Technical Bid | 28-Oct-2026 |
| 2 | 15-Oct-2026 | BOQ CORRIGENDUM | BOQ | 28-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Please Enable Macros to View BoQ information |
| 2 | Conversion of Existing 33KV, 11kV & LT OH Network to UG Cabling System for Section-1(GS Road) within the jurisdiction of Guwahati-I Electrical Circle, APDCL under Distribution Infrastructure works (Loss Reduction) of Revamped Distribution Sector Scheme (RDSS) |
| 3 | Total Amount of Supply Price |
| 4 | Total Amount of Installation/Erection charges |
| 5 | Total of complete work |
| 6 | Discount if any Offered by Bidder in % |
| 7 | Conversion of Existing 33KV, 11kV & LT OH Network to UG Cabling System for Section-1(GS Road) within the jurisdiction of Guwahati-I Electrical Circle, APDCL under Distribution Infrastructure works (Loss Reduction) of Revamped Distribution Sector Scheme (RDSS) |
| 8 | UG Cabling |
| 9 | SCADA DMS |
| 10 | 2.0 SUPPLY OF LINE MATERIALS :PART-A |
| 11 | Supply of Type tested 33 kV, 1 Core, 630 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable (33KV class) with suitable Cable Jointing & Termination Kit for Straight Through,Indoor & Outdoor |
| 12 | Supply of 33 kV, 1 Core, 630 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable |
| 13 | Supply of Indoor Terminating Kit Heat Shrikable type suitable for 33 kV class, 1 Core, 630 mm²,Aluminium UG Cable along with all fitting accessories required. |
| 14 | Supply of Outdoor Terminating Kit Heat Shrikable type suitable for 33 kV class, 1 Core, 630 mm²,Aluminium UG Cable along with all fitting accessories required. |
| 15 | Supply of Heat Shrikable type Straight Through Jointing Kit for 33 kV, 1 Core, 630 mm², Aluminiumr UG Cable along with all fitting accessories required. |
| 16 | Manadatory Spares : 33 kV, 1 Core, 630 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable (33KV class) with suitable Cable Jointing & Termination Kit for Straight Through,Indoor & Outdoor |
| 17 | Supply of 33 kV, 1 Core, 630 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable (Manadatory Spares) |
| 18 | Supply of Indoor Terminating Kit Heat Shrikable type suitable for 33 kV class, 1 Core, 630 mm²,Aluminium UG Cable along with all fitting accessories required. (Manadatory Spares) |
| 19 | Supply of Outdoor Terminating Kit Heat Shrikable type suitable for 33 kV class, 1 Core, 630 mm²,Aluminium UG Cable along with all fitting accessories required. (Manadatory Spares) |
| 20 | Supply of Heat Shrikable type Straight Through Jointing Kit for 33 kV, 1 Core, 630 mm², Aluminiumr UG Cable along with all fitting accessories required. (Manadatory Spares) |
| 21 | Supply of 33kV Outdoor type,Compact,SF6-Gas insulated, 36kV class,expandable,motorised Ring Main Unit with LBS having individual FPI and VCB with Earth Switch & protective relay, individual metering unit for both LBS & VCB,with inbuilt FRTU compatible for Distribution SCADA/Automation |
| 22 | Supply of 33kV 4-Way RMU with built in FRTU with 3 nos. Of LBS and 1 no. VCB of 630 Amp for 630 sqmm outgoing UG cable. |
| 23 | Supply of 33kV 3-Way RMU with built in FRTU with 2 nos. of LBS and 1no. of VCB of 630 Amp for 630 sqmm outgoing UG cable. |
| 24 | Supply of Type tested 11 kV, 3 Core, 400 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable (11KV class) with suitable Cable Jointing & Termination Kit for Straight Through,Indoor & Outdoor |
| 25 | Supply of 11 kV, 3C, 400 mm², Aluminium, TR-XLPE armoured UG cable |
| 26 | Supply of Heat Shrikable type Indoor Termination Kit for 11 kV, 3Core, 400 mm², aluminum UG Cable along with all fitting accessories required. |
| 27 | Supply of Heat Shrikable type Outdoor Termination Kit for 11 kV, 3Core, 400 mm², aluminum UG Cable along with all fitting accessories required. |
| 28 | Supply of Heat Shrikable type Straight Through Jointing Kit for 11 kV, 3Core, 400 mm², aluminum UG Cable along with all fitting accessories required. |
| 29 | Manadatory Spares : 11 kV, 3 Core, 400 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable (11KV class) with suitable Cable Jointing & Termination Kit for Straight Through,Indoor & Outdoor |
| 30 | Supply of 11 kV, 3C, 400 mm², Aluminium, TR-XLPE armoured UG cable (Manadatory Spares) |
| 31 | Supply of Heat Shrikable type Indoor Termination Kit for 11 kV, 3Core, 400 mm², aluminum UG Cable along with all fitting accessories required. (Manadatory Spares) |
| 32 | Supply of Heat Shrikable type Outdoor Termination Kit for 11 kV, 3Core, 400 mm², aluminum UG Cable along with all fitting accessories required. (Manadatory Spares) |
| 33 | Supply of Heat Shrikable type Straight Through Jointing Kit for 11 kV, 3Core, 400 mm², aluminum UG Cable along with all fitting accessories required. (Manadatory Spares) |
| 34 | Supply of 11kV Outddor type,Compact,SF6-Gas insulated,12kV class,expandable,motorised Ring Main Unit with LBS having individual FPI and VCB with Earth Switch & protective relay, for both LBS & VCB,with Inbuilt FRTU compatible for Distribution SCADA/Automation |
| 35 | Supply of 11kV 5-Way RMU with built in FRTU with 3 nos. of LBS & 2 no. of VCB of 630 Amp for 400 sqmm main UG cable for substation connectivity for 400 sqmm loop UG cable |
| 36 | Supply of 11kV 4-Way RMU with built in FRTU with 3 nos. of LBS & 1 no. of VCB of 630 Amp for 400 sqmm main UG cable for substation connectivity for 400 sqmm loop UG cable |
| 37 | Supply of 11kV 3-Way RMU with built in FRTU with 2 nos. of LBS & 1 no. of VCB of 630 Amp for 400 sqmm main UG cable for substation connectivity for 400 sqmm loop UG cable |
| 38 | Supply of Type tested 1.1 kV, 3.5 Core, 300 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable (1.1KV class) with suitable Cable Jointing & Termination Kit for Straight Through,Indoor & Outdoor |
| 39 | Supply of 1.1kV, 3.5 Core, 300 mm², Al, TR-XLPE, armored UG Cable |
| 40 | Supply of Heat Shrikable type Indoor Termination Kit for 1.1 kV, 3.5 Core, 300 mm², aluminum UG Cable along with all fitting accessories required. |
| 41 | Supply of Heat Shrikable type Outdoor Termination Kit for 1.1 kV, 3.5 Core, 300 mm², aluminum UG Cable along with all fitting accessories required. |
| 42 | Supply of Heat Shrikable type Straight Through Jointing Kit for 1.1 kV, 3.5 Core, 300 mm², aluminum UG Cable along with all fitting accessories required. |
| 43 | Supply of 1.1kV, 3.5 Core, 35 mm², Al, XLPE, armored UG Cable for Street lighting |
| 44 | Supply of assorted bi-metallic lug for 1.1kV, 3.5 Core, 35 mm², Al, XLPE, armored UG Cable. |
| 45 | Manadatory Spares : 1.1 kV, 3.5 Core, 300 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable (1.1KV class) with suitable Cable Jointing & Termination Kit for Straight Through,Indoor & Outdoor |
| 46 | Supply of 1.1kV, 3.5 Core, 300 mm², Al, TR-XLPE, armored UG Cable (Manadatory Spares) |
| 47 | Supply of Heat Shrikable type Indoor Termination Kit for 1.1 kV, 3.5 Core, 300 mm², aluminum UG Cable along with all fitting accessories required. (Manadatory Spares) |
| 48 | Supply of Heat Shrikable type Outdoor Termination Kit for 1.1 kV, 3.5 Core, 300 mm², aluminum UG Cable along with all fitting accessories required. (Manadatory Spares) |
| 49 | Supply of Heat Shrikable type Straight Through Jointing Kit for 1.1 kV, 3.5 Core, 300 mm², aluminum UG Cable along with all fitting accessories required. (Manadatory Spares) |
| 50 | Supply of 1.1kV, LT Feeder Pillar Box, Distribution Pillar Box and Service Pillar Box having Busbar (R,Y,B,N) for termination of 300 sqmm UG cable for connectivity. The entire unit need to be enclosed by Water proof, Fire proof, GI Steel sheet. |
| 51 | Supply of 1.1kV, 5-Way LT Feeder Pillar Box having Busbar (R,Y,B,N) provision with 2 nos. of HRC Fuse of 400 Amp for Incoming feeder and 3 nos. of HRC Fuse of 250 Amp for Outgoing feeder termination of 300 sqmm UG cable.The entire unit need to be enclosed by Water proof, Fire proof, GI Steel sheet. |
| 52 | Supply of 1.1kV, 5-Way LT Distribution Pillar Box having Busbar (R,Y,B,N) provision with 2 nos. of HRC Fuse of 400 Amp for Incoming feeder and 3 nos. of HRC Fuse of 250 Amp for Outgoing feeder termination of 300 sqmm UG cable.The entire unit need to be enclosed by Water proof, Fire proof, GI Steel sheet. |
| 53 | Supply of outdoor floor-mounted 400A Fuse Junction Boxes, complete with enclosure, 400A incoming arrangement, 400A porcelain Kit Kat fuse arrangement, terminals, earthing and internal wiring, suitable for installation in the distribution network |
| 54 | Supply of outdoor floor-mounted 100A Fuse Junction Boxes, complete with enclosure, 100A incoming arrangement, 400A porcelain Kit Kat fuse arrangement, terminals, earthing and internal wiring, suitable for installation in the distribution network for street lights |
| 55 | Supply of 1.1kV, 7-Way LT Service Pillar Box having Busbar (R,Y,B,N) provision with 1 no. of HRC Fuse of 250 Amp for Incoming feeder and 5 nos. of Kit-Kat Fuse of 63 Amp for Outgoing feeder termination of 300 sqmm UG cable.The entire unit need to be enclosed by Water proof, Fire proof, GI Steel sheet. |
| 56 | Supply of PE 80- PN8, HDPE Pipe for cable laying |
| 57 | Supply of 250 mm dia PE 80- PN8, HDPE Pipe for 33kV cable laying |
| 58 | Supply of 160 mm dia PE 80- PN8, HDPE Pipe for 11kV cable laying |
| 59 | Supply of 110 mm dia PE 80- PN8, HDPE Pipe for LT Cable laying |
| 60 | Supply of 63/50mm PLB(HDPE) pipe for LT Cable laying for street lights |
| 61 | Supply of Hardware Fittings for Cable Hoisting |
| 62 | Supply of Hardware Fittings for Cable Hoisting |
| 63 | Supply of Earthing Materials |
| 64 | Supply of GI earthing pipe 50mm dia 3m length 3.15mm thickness with preforated holes of 15mm dia at 30cm interval along the length of the pipe |
| 65 | Supply of 8 SWG (Standard Wire Gauge) Galvanized Iron (GI) wire for earthing is a 4.00 mm (0.157 inch) diameter, zinc-coated steel wire designed for corrosion resistance, typically conforming to IS:280-2006 (or newer). It offers high tensile strength (350-550 N/mm^2) and is used for electrical grounding. |
| 66 | Supply of 12 core Fiber,single mode, duct type, fibre armoured Optic Cable along with PLB Duct,Straight Through Connector & FO End Connector. |
| 67 | Supply of 12 core, single mode, duct type, fibre armoured Optical Fiber Cable laid along 33kV & 11kV UG cable |
| 68 | Supply of HDPE PLB Duct of size 32/26mm for laying of Optical Fiber Cable |
| 69 | Supply of 160 mm dia PE 80- PN8, HDPE Pipe for communication cables |
| 70 | Supply of Straight Through Connectors (Plastic Coupler) and acessories for OFC connection |
| 71 | Supply of End Connectors and acessories for OFC connection at RMUs & SS end |
| 72 | Supply of Van Mounted Cable Fault Locating Equipment with Mounting arrangement |
| 73 | Supply of Van Mounted Cable Fault Locating Equipment with Mounting arrangement & having 1 set - Pre-Wiring, 1 Set - Control Unit, 1 set - Surge Generator, 1 set - Cable Fault Locator, 1 set - Cable Identifier, 2 set - Pinpointing Unit, 1 set - Route Tracing Unit, 1 set - DC HV Testing Unit, 1 set - Fault Conditioning & Fault Burring Unit, 1 set - Cable, 1 set - DG Unit, 1 set - Safety Module, 1 No. - Mounting Van for Comprehensive set with all necessary advance set-up. |
| 74 | Supply of Portable cable test and fault location systemon low and medium voltage power cables |
| 75 | Supply of Portable cable test and fault location system on low and medium voltage power cables |
| 76 | Supply of armoured UG cable service Mains inside pipes from the L.T. Feeder pillar boxes to individual consumer installations (Average length of each service main 30mtr ) |
| 77 | Supply of 2 core x 10 sq mm PVC insulated UG armoured cable to be laid by open trench method and vertical wall run to the consumer energy meter. Average length of each service main 30mtr. (Single phase Consumers-1275nos) |
| 78 | Supply of 4 core x 10 sq mm PVC insulated UG cable to be laid by open trench method and vertical wall run to the consumer energy meter. Average length of each service main 30mtr..(3 phase Consumers-750 nos) |
| 79 | Supply of 4 core x 16 sq mm PVC insulated UG cable to be laid by open trench method and vertical wall run to the consumer energy meter. Average length of each service main 30mtr..(3 phase Consumers- 375 nos) |
| 80 | Supply of 4 core x 25 sq mm PVC insulated UG cable to be laid by open trench method and vertical wall run to the consumer energy meter. Average length of each service main 30mtr..(3 phase Consumers- 150 nos) |
| 81 | Supply of 63/50mm PLB(HDPE) pipe for LT service cable laying of individual consumers |
| 82 | Supply of 110/96mm PLB (HDPE) pipe for LT service cable laying of group of consumers |
| 83 | Supply of Service main Cable Accessories for above sized cables |
| 84 | Supply of Clamps-8 nos/ one service main 1phase-4 |
| 85 | Supply of Terminal Connector-4 nos/ one service main 1phase consumer |
| 86 | Supply of Terminal conectors for 10 sq mm PVC insulated UG cable 3phase-8 ERECTION OF FOLLOWING EQUIPMENT & MATERIALS(As per Technical Specification) ELECTRICAL WORKS (PART-A) |
| 87 | Laying, Comissioning & Testing of Type tested 33 kV, 1 Core, 630 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable (33KV class) with suitable Cable Jointing & Termination Kit for Straight Through,Indoor & Outdoor at other Utilities or Private properties. |
| 88 | 33 kV, 1 Core, 630 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable via Direct Burried Method as per approved scheme |
| 89 | 33 kV, 1 Core, 630 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable 1 Runs through HDPE pipe by Open Trench method, as per approved scheme |
| 90 | 33 kV, 1 Core, 630 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable 1 Runs through HDPE pipe by HDD method, as per approved scheme |
| 91 | Erection, Testing & Commissioning of Indoor Terminating Kit Heat Shrikable type suitable for 33 kV class, 1 Core, 630 mm²,Aluminium UG Cable |
| 92 | Erection, Testing & Commissioning of Outdoor Terminating Kit Heat Shrikable type suitable for 33 kV class, 1 Core, 630 mm²,Aluminium UG Cable |
| 93 | Erection, Testing & Commissioning of Heat Shrikable type Straight Through Jointing Kit for 33 kV, 1Core, 630 mm²,Aluminiumr UG Cable |
| 94 | Restoration charges in Public & Private premises. |
| 95 | Erection, Testing & Commissioning of 33kV Outdoor type,Compact,SF6-Gas insulated,36kV class,expandable,motorised Ring Main Unit with LBS having individual FPI and VCB with Earth Switch & protective relay,individual metering unit for both LBS & VCB,with Inbuilt FRTU compatible for Distribution SCADA/Automation |
| 96 | Erection, Testing & Commissioning of 33kV 4-Way RMU with built in FRTU with 4 nos. VCB of 630 Amp for 630 sqmm outgoing UG cable. |
| 97 | Erection, Testing & Commissioning of 33kV 3-Way RMU with built in FRTU with 3 nos. VCB of 630 Amp for 630 sqmm outgoing UG cable. |
| 98 | Laying, Comissioning & Testing of 11 kV, 3 Core, 400 mm² Aluminium, TR-XLPE insulation UG Cable including Erection of suitable Cable Jointing Kit & Termination Kit and restoration at other Utilities or Private properties. |
| 99 | 11 kV, 3 Core, 400 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable via Direct Buried Method as per approved scheme |
| 100 | 11 kV, 3 Core, 400 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable 1 Runs through HDPE pipe by Open Trench method, as per approved scheme |
| 101 | 11 kV, 3 Core, 400 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable 1 Runs through HDPE pipe by HDD Method, as per approved scheme |
| 102 | Erection, Testing & Commissioning of Heat Shrikable type Indoor Termination Kit for 11 kV, 3Core, 400 mm², aluminum UG Cable for termination |
| 103 | Erection, Testing & Commissioning of Heat Shrikable type Outdoor Termination Kit for 11 kV, 3Core, 400 mm², aluminum UG Cable for termination |
| 104 | Erection, Testing & Commissioning of Heat Shrikable type Straight Through Jointing Kit for 11 kV, 3Core, 400 mm², aluminum UG Cable |
| 105 | Restoration charges in Public & Private premises. |
| 106 | Erection, Testing & Commissioning of 11kV Outddor type,Compact,SF6-Gas insulated,12kV class,expandable,motorised Ring Main Unit with LBS having individual FPI and VCB with Earth Switch & protective relay,individual metering unit for both LBS & VCB,with Inbuilt FRTU compatible for Distribution SCADA/Automation |
| 107 | Erection, Testing & Commissioning of 11kV 5-Way RMU with built in FRTU with 2 nos. of LBS & 3 no. of VCB of 630 Amp for 400 sqmm main UG cable for substation connectivity for 400 sqmm loop UG cable |
| 108 | Erection, Testing & Commissioning of 11kV 4-Way RMU with built in FRTU with 3 nos. of VCB & 1 no. of LBS of 630 Amp for 400 sqmm main UG cable for substation connectivity for 400 sqmm loop UG cable |
| 109 | Erection, Testing & Commissioning of 11kV 3-Way RMU with built in FRTU with 2 nos. of LBS & 1 no. of VCB of 630 Amp for 400 sqmm main UG cable for substation connectivity for 400 sqmm loop UG cable |
| 110 | Laying, Comissioning & Testing of 1.1 kV, 3.5 Core,1-Run, 300 mm² Aluminium, TR-XLPE insulation UG Cable including Erection of suitable Cable Jointing Kit & Termination Kit and restoration at other Utilities or Private properties. |
| 111 | 1.1 kV, 3.5 Core, 300 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable 1 Runs through Open Trench method, as per approved scheme |
| 112 | 1.1 kV, 3.5 Core, 300 mm² Aluminium, TR-XLPE insulation armoured (Extruded type) UG cable 1 Runs through HDPE pipe by Open Trench method, as per approved scheme |
| 113 | Erection, Testing & Commissioning of Heat Shrikable type Indoor Termination Kit for 1.1 kV, 3.5Core, 300 mm², aluminum UG Cable for termination |
| 114 | Erection, Testing & Commissioning of Heat Shrikable type Outdoor Termination Kit for 1.1 kV, 3.5Core, 300 mm², aluminum UG Cable for termination |
| 115 | Erection, Testing & Commissioning of Heat Shrikable type Straight Through Jointing Kit for 1.1 kV, 3.5 Core, 300 mm², aluminum UG Cable |
| 116 | 1.1kV, 3.5 Core, 35 mm², Al, XLPE, armored UG Cable for Street lights Runs through Open Trench method, as per approved scheme along with installation of bimetallic lugs for termination wherever required |
| 117 | Erection, Testing & Commissioning of 1.1kV, LT Feeder Pillar Box having Busbar (R,Y,B,N) for termination of 300 sqmm UG cable for connectivity. The entire unit need to be enclosed by Water proof, Fire proof, GI Steel sheet. |
| 118 | Erection, Testing & Commissioning of 1.1kV, 5-Way LT Feeder Pillar Box having Busbar (R,Y,B,N) provision with 2 nos. of HRC Fuse of 400 Amp for Incoming feeder and 3 nos. of HRC Fuse of 250 Amp for Outgoing feeder termination of 300 sqmm UG cable for connectivity between DT and FPB.The entire unit need to be enclosed by Water proof, Fire proof, GI Steel sheet. |
| 119 | Erection, Testing & Commissioning of 1.1kV, 5-Way LT Distribution Pillar Box having Busbar (R,Y,B,N) provision with 2 nos. of HRC Fuse of 400 Amp for Incoming feeder and 3 nos. of HRC Fuse of 250 Amp for Outgoing feeder termination of 300 sqmm UG cable.The entire unit need to be enclosed by Water proof, Fire proof, GI Steel sheet. |
| 120 | Erection, Testing & Commissioning of outdoor floor-mounted 400A Fuse Junction Boxes, complete with enclosure, 400A incoming arrangement, 400A porcelain Kit Kat fuse arrangement, terminals, earthing and internal wiring, suitable for installation in the distribution network |
| 121 | Erection, Testing & Commissioning of outdoor floor-mounted 100A Fuse Junction Boxes, complete with enclosure, 100A incoming arrangement, 400A porcelain Kit Kat fuse arrangement, terminals, earthing and internal wiring, suitable for installation in the distribution network for street lights |
| 122 | Erection, Testing & Commissioning of 1.1kV, 7-Way LT Service Pillar Box having Busbar (R,Y,B,N) provision with FOR 400 A, 433 V AC with Rewirable (Kit-Kat) Fuses (5 Outgoings) for Outgoing feeder termination of 300 sqmm UG cable.The entire unit need to be enclosed by Water proof, Fire proof, GI Steel sheet. |
| 123 | Erection, Testing & Commissioning of 80- PN8, HDPE Pipe for Cable laying |
| 124 | Erection, Testing & Commissioning of 250 mm dia PE 80- PN8, HDPE Pipe for 33kV and 11kV cable laying |
| 125 | Erection, Testing & Commissioning of 160 mm dia PE 80- PN8, HDPE Pipe for 33kV and 11kV cable laying |
| 126 | Erection, Testing & Commissioning of 110 mm dia PE 80- PN8, HDPE Pipe for LT Cable laying |
| 127 | Erection, Testing & Commissioning of 63/50mm PLB(HDPE) pipe for LT Cable laying for street lights |
| 128 | Erection, Testing & Commissioning of Hardware Fittings for Cable Hoisting |
| 129 | Erection, Testing & Commissioning of Hardware Fittings for Cable Hoisting |
| 130 | Erection of Earthing Materials |
| 131 | Erection, Testing & Commissioning of GI earting pipe 50mm dia 3m length 3.15mm thickness with preforated holes of 15mm dia at 30cm interval along the length of the pipe |
| 132 | Erection, Testing & Commisioning of 8 SWG (Standard Wire Gauge) Galvanized Iron (GI) wire for earthing is a 4.00 mm (0.157 inch) diameter, zinc-coated steel wire designed for corrosion resistance, typically conforming to IS:280-2006 (or newer). It offers high tensile strength (350-550 N/mm^2) and is used for electrical grounding. |
| 133 | Laying, Commissioning & Testing of 12 core,Single mode Fibre Optic cables through PLB duct including erection of St. through Connector & End Connector |
| 134 | Laying,Commissioning & Testing of 12 core Single mode Fibre Optic cables through PLB Duct laid along 33 kV & 11kV UG cable in existing RCC Cable trench as per instruction of Engg. Incharge |
| 135 | Laying of Communication Cables through HDPE pipes laid along LT UG cable alongside existing RCC cable trench as per instruction of Engineer In Charge |
| 136 | Erection,Commissioning & Testing of Straight Through Connectors (Plastic Coupler) and acessories for OFC connection |
| 137 | Erection, Testing & Commissioning of End Connectors and acessories for OFC connection at RMUs & SS end CIVIL WORKS (PART-B) Civil works for laying of 33kV, 11kV & LT cable (as per the designed cable route) in existing open cable trench |
| 138 | Civil works for laying of 33kV, 11kV & LT cable (as per the designed cable route) in existing open cable trench by Executing Agency/APDCL |
| 139 | Excavation along the road and tunneling under drain for cable crossing along with back-filling, for laying of 33kV, 11kV & LT cable (as per the designed cable route) in existing open cable trench of ((W) 800mm X (D)1605mm) |
| 140 | Excavation along the road and tunneling under drain for cable crossing along with back-filling, for laying of 33kV, 11kV & LT cable (as per the designed cable route) in existing open cable trench of ((W)1200mmX (D)1605mm) |
| 141 | Excavation along the road and tunneling under drain for cable crossing along with back-filling, for laying of 33kV, 11kV & LT cable (as per the designed cable route) in existing open cable trench of ((W)1200mm X (D)1980mm) |
| 142 | Excavation along the road and tunneling under drain for cable crossing along with back-filling, for laying of 11kV & LT cable (as per the designed cable route) in existing open cable trench of ((W)800mm X (D)1230mm) |
| 143 | Excavation along the road and tunneling under drain for cable crossing along with back-filling, for laying of LT cable (as per the designed cable route) in existing open cable trench of ((W)800mm X (D)855mm) |
| 144 | Supply and Erection of Equipment Foundation with all accessories |
| 145 | Supply & Erection of RCC Foundation of 0.6m for 3-Way 33kV RMU with built in FRTU including supply of all materials, Excavation of soil,Shifting of soil etc(M-25 Grade) |
| 146 | Supply & Erection of RCC Foundation of 1m for 3-Way 33kV RMU with built in FRTU including supply of all materials, Excavation of soil,Shifting of soil etc(M-25 Grade) |
| 147 | Supply & Erection of RCC Foundation of 0.6m for 4-Way 33kV RMU with built in FRTU including supply of all materials, Excavation of soil,Shifting of soil etc(M-25 Grade) |
| 148 | Supply & Erection of RCC Foundation of 1m for 4-Way 33kV RMU with built in FRTU including supply of all materials, Excavation of soil,Shifting of soil etc(M-25 Grade) |
| 149 | Supply & Erection of RCC Foundation of 0.6m for 3-Way 11kV RMU with built in FRTU including supply of all materials, Excavation of soil,Shifting of soil etc(M-25 Grade) |
| 150 | Supply & Erection of RCC Foundation of 1m for 3-Way 11kV RMU with built in FRTU including supply of all materials, Excavation of soil,Shifting of soil etc(M-25 Grade) |
| 151 | Supply & Erection of RCC Foundation of 0.6m for 4-Way 11kV RMU with built in FRTU including supply of all materials, Excavation of soil,Shifting of soil etc(M-25 Grade) |
| 152 | Supply & Erection of RCC Foundation of 1m for 4-Way 11kV RMU with built in FRTU including supply of all materials, Excavation of soil,Shifting of soil etc(M-25 Grade) |
| 153 | Supply & Erection of RCC Foundation of 0.6m for 5-Way 11kV RMU with built in FRTU including supply of all materials, Excavation of soil,Shifting of soil etc(M-25 Grade) |
| 154 | Supply & Erection of RCC Foundation of 1m for 5-Way 11kV RMU with built in FRTU including supply of all materials, Excavation of soil,Shifting of soil etc(M-25 Grade) |
| 155 | Supply & Erection of RCC Foundation of 0.6m for 5 Way LT FPB/DPB ncluding supply of all materials, Excavation of soil,Shifting of soil etc(M-25 Grade) |
| 156 | Supply & Erection of RCC Foundation of 1m for 5 Way LT FPB/DPB ncluding supply of all materials, Excavation of soil,Shifting of soil etc(M-25 Grade) |
| 157 | Supply & Erection of RCC Foundation of 0.6m for 7 Way LT SPB including supply of all materials, Excavation of soil,Shifting of soil etc (M-25 Grade) |
| 158 | Supply & Erection of RCC Foundation of 1m for 7 Way LT SPB including supply of all materials, Excavation of soil,Shifting of soil etc (M-25 Grade) |
| 159 | Supply & Erection of RCC Foundation of 0.6m for 400 A Fuse Junction Boxes including supply of all materials, Excavation of soil,Shifting of soil etc (M-25 Grade) |
| 160 | Supply & Erection of RCC Foundation of 0.6m for 100 A Fuse Junction Boxes including supply of all materials, Excavation of soil,Shifting of soil etc (M-25 Grade) |
| 161 | Supply & Erection of Double Pole Structure Equipment Foundation with all accessories |
| 162 | Supply & Erection of Double Pole Structure Equipment Foundation with all accessories (ISMB & ISMC Steel Structure considered) |
| 163 | Supply & Erection of Double Pole Structure Equipment Foundation with all accessories (For 33kV UG to OH Structure) |
| 164 | Supply & Erection of Double Pole Structure Equipment Foundation with all accessories (For 11kV UG to OH Structure) |
| 165 | Civil work for Route Marking & Cable Crossing |
| 166 | Supply & Erection of Cable Route Markers at an interval of 100 mtrs. |
| 167 | Supply & Erection of Cable Bridge |
| 168 | Supply & Erection of Cable Bridge made of Galvanised Iron for 33kV, 11kV cable for crossing of water body (per square meter weighs 1Quintal). 11 number of cable bridge are required in Section-1(GS Road) |
| 169 | Supply & Erection of Cable Bridge Foundation |
| 170 | Dismantling of Existing Assets |
| 171 | Dismantling of 33kV, 11kV & LT line conductor/cable along with pole, X-arm, etc. & returning to store |
| 172 | Laying,Commissioning and testing of UG cable service Mains inside pipes from the L.T. Feeder pillar boxes to individual consumer installations (Average length of each service main 30mtr ) |
| 173 | Laying of 2 core/ 4 core x 10/16/25 sq mm PVC insulated UG cable to be laid by open trench method with PLB (HDPE) duct and vertical wall run to the consumer energy meter, Average length of each service main 30mtr. |
| 174 | Laying of 63/50 mm PLB (HDPE) pipe for individual consumers |
| 175 | Laying of 110/96 mm PLB(HDPE) pipe for group of consumers |
| 176 | Laying of 110/96 mm PLB (HDPE) pipe for group of consumers in microtunneling |
| 177 | Excavation, Sand Bedding, Brick Padding & Backfilling (300 mm wide trench, 600 mm deep) of total cable |
| 178 | Erection of Service main Cable Accessories |
| 179 | Erection of Clamps-8 nos for one service main |
| 180 | Erection of Terminal conectors 4 nos for one service main |
| 181 | Erection of Terminal conectors 8 nos for one service main |
| 182 | Statutory charges |
| 183 | Statutory charges (against the charges towards GMC, PHED etc.) including inspection charges (Lumpsum) |
| 184 | Capacity Building Charges |
| 185 | Capacity Building and Training for Employer for smooth operation & maintanance of the entire UG network for 1 year from the takeover of the first Section. |
| 186 | Hardware for Control Centre As per TS |
| 187 | SCADA Server |
| 188 | DMS Server |
| 189 | OMS Server |
| 190 | ISR server |
| 191 | NMS server |
| 192 | DTS server |
| 193 | Developmental server |
| 194 | Commnuication Server |
| 195 | Web/Directory server |
| 196 | Workstation with dual TFT Monitors ( S/S monitoring) |
| 197 | Workstation with dual TFT Monitors (Network monitoring) |
| 198 | Remote VDUs with one TFT Monitors |
| 199 | Developmental console with one TFT |
| 200 | DTS/Workstation Console with dual TFTs |
| 201 | DLP/ LED based Video Projection system with 3x4 Module configuration with each module at least 67\\" diagonal with common projector |
| 202 | Storage & Backup Devices |
| 203 | External RAID Mass storage device ( for 24 months online backup) |
| 204 | External DAT drive |
| 205 | Switches |
| 206 | Layer II switch (SCADA/DMS LAN) |
| 207 | Layer II switch ( Planning & Development system LAN) |
| 208 | Routers |
| 209 | Router for interfacing IT system & SCADA/DMS DR centre |
| 210 | Router at remote VDU |
| 211 | Security system (DMZ) |
| 212 | Web server with load balancing |
| 213 | Mail server |
| 214 | Router |
| 215 | Firewall & network IDS/IPS |
| 216 | Layer II switch |
| 217 | Other Active Devices |
| 218 | GPS Time synchronisation system |
| 219 | Time, day & date digital displays |
| 220 | Printers |
| 221 | Color inkjet printer |
| 222 | B/W Laser printer |
| 223 | Software For Control Center |
| 224 | SCADA software |
| 225 | ISR Software |
| 226 | DMS software |
| 227 | DTS software |
| 228 | Developmental software |
| 229 | Network Management Software |
| 230 | WEB /Network security software |
| 231 | RDBMS package |
| 232 | GIS Adaptor/Engine for importing data from GIS system under IT system |
| 233 | Manadatory Spares |
| 234 | Mandatory Spares |
| 235 | Hardware For DR Center As per TS |
| 236 | DR Server |
| 237 | Commnuication Server |
| 238 | Workstation with single TFT Monitor |
| 239 | Storage & Backup Devices |
| 240 | External RAID Mass storage device ( for24 months online backup) |
| 241 | External DAT drive |
| 242 | Switches |
| 243 | Layer II switch (SCADA/DMS LAN) |
| 244 | Routers |
| 245 | Router for interfacing IT system & SCADA/DMS DR centre |
| 246 | Other Active Devices |
| 247 | GPS Time synchronisation system |
| 248 | Time, day & date digital displays |
| 249 | Software For DR Center As per TS |
| 250 | SCADA software |
| 251 | Mandatory Spares |
| 252 | Manadatory Spares |
| 253 | Mandatory Spares |
| 254 | RTU base equipment comprising panels, racks, sub-racks, Power Supply modules, CPU, interfacing equipment, required converters & all other required items/accessories including complete wiring for all modules for locations mentioned at Vol Vi (Should be compatible for IEC 62056 along with other protocols metioned in SBD) |
| 255 | Multifunctional transducers |
| 256 | Contact Multiplying Relays (CMRs) |
| 257 | Heavy duty relays for Control |
| 258 | Dummy Breaker Latching Relays |
| 259 | Transformer Transducers |
| 260 | Single TFT PC for LDMS with OS |
| 261 | DC Current Transducer |
| 262 | DC Voltage Transducer |
| 263 | AC Voltage Transducer |
| 264 | OTI and WTI Temperature Indicator |
| 265 | ACDB with sufficient MCBs |
| 266 | Ethernet Switchs 24 Ports for Relay Networking |
| 267 | Weather transducer - Wind speed |
| 268 | Weather transducer - Rainfall |
| 269 | Weather transducer - Humidity |
| 270 | Weather transducer -Temperature |
| 271 | Weather transducer -Wind Direction |
| 272 | TEST EQUIPMENTS for RTU |
| 273 | RTU Database Configuration & Maintenance Software tool |
| 274 | Master Station cum RTU Simulator & Protocol analyser software tool |
| 275 | Laptop PC for above software tools along with interfacing hardware including Hub |
| 276 | Manadatory Spares |
| 277 | Mandatory Spares |
| 278 | Test Equipments for FRTU |
| 279 | FRTU Database Configuration & Maintenance Software tool |
| 280 | Master Station cum FRTU Simulator & Protocol analyser software tool |
| 281 | Laptop PC for above software tools along with interfacing hardware including Hub |
| 282 | Dual redundant link Network Connectivity Charge for 100MbPS Link at CC |
| 283 | Dual redundant link Network Connectivity Charge for 100MbPS Link at DR |
| 284 | Dual redundant link Network Connectivity Charge for 2 MbPS Link at SS |
| 285 | Dual redundant link Network connectivity from CC to optic fiber WAN/LAN (Field devices ) |
| 286 | MPLS Router |
| 287 | Dual redundant link Network Connectivity Charge (GPRS) 5G Link for Field devices as RVDU, FRTU |
| 288 | Modems |
| 289 | Manadatory Spares |
| 290 | Mandatory Spares |
| 291 | Main Equipments - DR Centre |
| 292 | UPS with suitable rating running in parallel redundant mode* |
| 293 | For RTU / Data Concentrator / Communication Eqpts. |
| 294 | DC Power Supply (DCPS) system based on SMPS |
| 295 | 2 kVA online UPS for RTU Locations with VRLA Batteries to give 4 hrs back up |
| 296 | Remote VDU location |
| 297 | UPS (2 kVA ) |
| 298 | Manadatory Spares |
| 299 | Mandatory Spares |
| 300 | Facility Managament Services for 5 Years after GO-LIVE |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
TodayCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
TodayBid Submission Deadline
Online submission via eProcurement portal.
TodayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender