Housing Urban and Rular Development Local Bodies Closing in 4 days TDR #57898952

Tender For Special Repair For Non Residential Building Sports Complex In Sector 56, Chandigarh For The Year 2026-27

Issued by Local Bodies · Chandigarh, Chandigarh
Tender Value
2.10 Lakhs
Estimated cost
Bid Submission
13 Oct 2026
4 days left
EMD
4216
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Special Repair For Non Residential Building Sports Complex In Sector 56, Chandigarh For The Year 2026-27

BOQ

Name of Work:- SPECIAL REPAIR FOR NON RESIDENTIAL BUILDING SPORTS COMPLEX IN SECTOR 56, CHANDIGARH FOR THE YEAR 2026-27
Sl. No. Item Description
1Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (As per DSR 8.31)
2Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (As per DSR 9.20.1)
3Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (As per DSR 9.76)
4Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100 mm (As per DSR 9.100.2)
5Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete Twin rubber stopper (As per DSR 9.101.2)
6Providing and fixing precoated galvanised iron profile sheets (size, shapeand pitch of corrugation as approved by Engineer-in-Charge) of totalcoated thickness 0.50 mm (base metal of minimum 0.45 mm thicknesswith total coating thickness of 0.05mm) with zinc coating 120 grams persqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer onboth side of the sheet and polyester top coat 15-18 microns. Sheet shouldhave protective guard film of 25 microns minimum to avoid scratchesduring transportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixedusing self drilling /self tapping screws of size (5.5x 55 mm) with EPDMseal, complete upto any pitch in horizontal/ vertical or curved surfaces,excluding the cost of purlins, rafters and trusses and including cutting tosize and shape wherever required. (As per DSR 12.5)
712 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) (As per DSR 13.1.1)
8Providing and fixing double scaffolding system (cup lock type) on theexterior side, up to seven story height made with 40 mm dia M.S. tube1.5 m centre to centre, horizontal & vertical tubes joining with cup & locksystem with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircasesystem in the scaffolding for working platform etc. and maintaining it in aserviceable condition for the required duration as approved and removingit there after. The scaffolding system shall be stiffened with bracings,runners, connection with the building etc wherever required for inspectionof work at required locations with essential safety features for the workmenetc. complete as per directions and approval of Engineer-in-charge. Theelevational area of the scaffolding shall be measured for payment purpose.The payment will be made once irrespective of duration of scaffolding. (As per DSR 14.72)
9Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (As per DSR 15.56)
10Providing and laying vitrified floor tiles of specified size (thickness to be specified by the manufacturer) of 1st quality with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm single charge (N.S.)
11Repair of deteriorated RCC Balconies, Beams, Walls, Ceiling, Column or other concrete surface having exposed rusted bars consisting of following operations (a) chipping of concrete surface 25mm thick average depth afterwards remocal of loose concrete and exposing the steel bars. Cleaning the surface properly to remove dust particles and rust from the steel bars. (b) Moistening the surface properly and applying arcylic polymer (acrocrete/ pidilite/ mastercrete or its equivalent) coating mixed with cement for proper bonding of old and new concrete in two coats 0.2kg per 1kg of cement. (c) Providing and fixing chicken mesh of standard size and 26 guage with steel reinforcement by using binding wire and nails complete. (d) Proving and placing of cement concrete l:11/2:3 having average thickness 1\\" (3/4\\" to 11/4\\" thick) mixed with arcylic polymer admixture @ 1kg per bag of cement and waterproof agent @ 400ml per 2 bags of cement including finishing the surface complete in all respect as per the direction and to the entire satisfaction of Engineer-in-Charge. (N.S.)
12Providing and fixing 8mm thick tuffoned glass panes over existing chowkhats or glazed shutter including the cost of nails, putty etc complete in all respects to the entire satisfaction of Engineer-in-charge. (N.S.) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57898952
AUTHORITY Local Bodies
TENDER VALUE 2.10 Lakhs
LAST DATE 13-10-2026
Authority
Authority Name Chandigarh Administration Engineering Department
Work Description Tender for Special Repair For Non Residential Building Sports Complex In Sector 56, Chandigarh For The Year 2026-27
Basic Detail
Tender No CP4/2026/3163789
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 06 Oct 2026
Submission Date 13 Oct 2026
Open Date 13 Oct 2026
Finance
Tender Value 2.10 Lakhs
Tender Fee Ref. Documents
EMD 4216
Exemption Not Available
Document List
750ec218-20b8-4ece-affd-e558c7b906db.html
BOQ_117886.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Oct 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

750ec218-20b8-4ece-affd-e558c7b906db.html

xls

BOQ_117886.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders