Coal and Mines Boards / Undertakings / PSU Closing in 0 days TDR #57898927

Tender For Emergency Replacement And Rectification Of Damaged G.I Pipe Lines, Valves Etc. For Bkts, Nnts, C.I.S.F Barrack And Other Under Block-Ii Area. Vide Enit Ref. No.- Gm/B Ii/Civil/E-Tender/26-27/25 Dated- 06.10.2026

Issued by Boards / Undertakings / PSU · Dhanbad, Jharkhand
Tender Value
6.85 Lakhs
Estimated cost
Bid Submission
16 Oct 2026
0 days left
EMD
8600
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dhanbad → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Emergency Replacement And Rectification Of Damaged G.I Pipe Lines, Valves Etc. For Bkts, Nnts, C.I.S.F Barrack And Other Under Block-Ii Area. Vide Enit Ref. No.- Gm/B Ii/Civil/E-Tender/26-27/25 Dated- 06.10.2026

BOQ

Name of Work:- Emergency replacement and rectification of damaged G.I Pipe lines, Valves etc. for BKTS, NNTS, C.I.S.F Barrack and other under Block-II Area. vide eNIT ref. no.- GM/B II/CIVIL/E-TENDER/26-27/25 dated- 06.10.2026
Sl. No. Item Description
1Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 80 mm dia nominal bore.
2Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 50 mm dia nominal bore.
3Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 40 mm dia nominal bore.
4Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 25 mm dia nominal bore.
5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal outer dia Pipes.
6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm nominal outer dia Pipes.
7Labour charge for refiximg of G.I pipe 80mm dia etc.
8Labour charge for refiximg of G.I pipe 50mm dia etc.
9Labour charge for refiximg of G.I pipe 40mm dia etc.
10Labour charge for refiximg of G.I pipe 25mm dia etc.
11Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge :15 mm to 40 mm nominal bore.
12Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge :Above 40 mm nominal bore.
13P/F G.I flange 80mm dia etc.
14Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :50 mm nominal bore.
15Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :40 mm nominal bore.
16Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :25 mm nominal bore.
17P/F sluice valve 80 mm dia etc.
18Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
19Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore
20Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
21Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore
22Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :25 to 40 mm nominal bore
23Cleaning debries, mud soil in liquid, malba from pipe line portion etc.
24P/F nut-bolt etc.
25P/F rubber packing gasket etc.
26Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57898927
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 6.85 Lakhs
LAST DATE 16-10-2026
Authority
Authority Name Bharat Coking Coal Limited
Work Description Tender for Emergency Replacement And Rectification Of Damaged G.I Pipe Lines, Valves Etc. For Bkts, Nnts, C.I.S.F Barrack And Other Under Block-Ii Area. Vide Enit Ref. No.- Gm/B Ii/Civil/E-Tender/26-27/25 Dated- 06.10.2026
Basic Detail
Tender No GM/BII/CIVIL/E-TENDER/26-27/25 dated-06.10.2026
Bidding Type Tender
Location
City Dhanbad
State Jharkhand
Key Dates
Publish Date 06 Oct 2026
Submission Date 16 Oct 2026
Open Date 17 Oct 2026
Finance
Tender Value 6.85 Lakhs
Tender Fee Ref. Documents
EMD 8600
Exemption Not Available
Document List
BOQ_379606.xls
e6c798ff-5678-493b-a033-bf3f42bb0984.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_379606.xls

html

e6c798ff-5678-493b-a033-bf3f42bb0984.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender