Coal and Mines Boards / Undertakings / PSU Closing in 9 days TDR #57898910

Tender For Making Of Foundation For Various Electrical Equipment/Transformers And Replacement Of Damaged Fencing/Boundary Around Different Sub-Station Installed At Saoner Sub Area Of Nagpur Area. E-

Issued by Boards / Undertakings / PSU · Nagpur, Maharashtra
Tender Value
19.72 Lakhs
Estimated cost
Bid Submission
19 Oct 2026
9 days left
EMD
24700
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nagpur → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Making Of Foundation For Various Electrical Equipment/Transformers And Replacement Of Damaged Fencing/Boundary Around Different Sub-Station Installed At Saoner Sub Area Of Nagpur Area. E-

BOQ

Name of Work:- Making of foundation for various electrical equipment/transformers and replacement of damaged fencing/boundary around different sub-station installed at Saoner Sub Area of Nagpur Area. e-
Sl. No. Item Description
1Surafce dressing of the ground including removing vegetation and in- equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil
2Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:All kinds of soil
3Supplying, spreading & compacting of Agggates size 63mm to 45 mm & 45 to 22.5 mm in two layers as per direction of Eng-In-Chrage.
4Repairs to plaster of thickness 12 mm to 20 mm in patchesof area 2.5 sq.meters and under, including cutting thepatch in proper shape, raking out joints and preparing andplastering the surface of the walls complete, includingdisposal of rubbish to the dumping ground, all complete asper direction of Engineer-in-Charge.With cement mortar 1:4 (1 cement : 4 fine sand)
5Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shadeOld work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface
6Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
7Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
8Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.All kinds of soil
9Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
10Providing and laying in position cement concrete ofspecified grade excluding the cost of centering andshuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand(zone-III) derived fromnatural sources : 8 graded stone aggregate 40 mm nominalsize derived from natural sources)
11Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand).
1212 mm cement plaster of mix :1:6 (1 cement: 6 fine sand)
13White washing with lime to give an even shade :New work (three or more coats)
14Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
15Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of ____mm aluminum sheet bonded with white retro reflective sheeting of Class __ ( Type IV High intensity microprismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.4mm aluminum composite material Class B
16Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
17Reinforced cement concrete work in beams, suspended foors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
18Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinthlevel.Thermo-Mechanically Treated bars of grade Fe-500D or more.
19Centering and shuttering including strutting, propping etc . And removal of form forWalls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
20Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
21Filling available excavated earth (excluding rock) in trenches, plinth. sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and for all lift
22Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.Made of G.I. wire of dia 4 mm
23Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work
24Carriage of earth or unwanted material at site as pe direction of Eng-in-Chrage.
25Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57898910
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 19.72 Lakhs
LAST DATE 19-10-2026
Authority
Authority Name Western Coalfields Limited
Work Description Tender for Making Of Foundation For Various Electrical Equipment/Transformers And Replacement Of Damaged Fencing/Boundary Around Different Sub-Station Installed At Saoner Sub Area Of Nagpur Area. E-
Basic Detail
Tender No na3250-civ-e-tender 45-2026-27
Bidding Type Tender
Location
City Nagpur
State Maharashtra
Key Dates
Publish Date 06 Oct 2026
Submission Date 19 Oct 2026
Open Date 21 Oct 2026
Finance
Tender Value 19.72 Lakhs
Tender Fee Ref. Documents
EMD 24700
Exemption Not Available
Document List
1d282dd3-0c59-4dcd-919c-55714b818ca9.html
BOQ_379592.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Oct 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

1d282dd3-0c59-4dcd-919c-55714b818ca9.html

xls

BOQ_379592.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders