Drinking Water Supply and Sanitation Government Departments Closing in 9 days TDR #57898572

Tender For Construction Of E Type Quarter At Rayagada Under Rwss Division, Rayagada In The District Of Rayagada For The Year 2026-27

Issued by Government Departments · Rayagada, Odisha
Tender Value
98.31 Lakhs
Estimated cost
Bid Submission
21 Oct 2026
9 days left
EMD
98317
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Rayagada → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of E Type Quarter At Rayagada Under Rwss Division, Rayagada In The District Of Rayagada For The Year 2026-27

BOQ

Name of Work:- Construction of E type quarter at Rayagada under RWSS Division, Rayagada in the District of Rayagada for the year 2026-27
Sl. No. Item Description
1Construction of E type quarter at Rayagada under RWSS Division
2(i) Civil works: Clearing and grubbing roads and land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness.
3Earth work in excavation in foundation trenches, column foundation, pit, etc in all kind of soil including moorum stony earth and earth mixed with boulders except sheet rock and boulders not requiring blasting including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site with initial lead of 50 mtr and all lifts, including shoring, shuttering & dewatering (if required) with cost of labour, labour cess, hire & running charges of all machineries, sundries & T&P required for the work complete as directed by the Engineer in charge.Upto 1.5mtr Depth
4-Do- Beyond 1.5mtr to 3.00 mtr Depth
5Disposal of surplus/ excavated materials by mechanical means within 5km. Lead away from the site including cost of all labour , T&P complete as per the direction of the Engineer-in-charge.
6Filling the Foundation and Plinth, sides of foundation, etc. with excavated materials (excluding rock), in layers not exceeding 0.225 m in depth including cost of watering, ramming, dressing and levelling the top to proper level & gradient, cost of labour, conveyance, loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge.
7Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. at the rate of 7.5 liters per sqm on vertical surface and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center (or as directed by the manufacturer) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge. ( The payment shall be made on the basis of actual plinth area of the building at ground floor and vertical faces will not be measured for payment). Note- The contractor shall have to furnish Ten (10) years guarantees to maintain the anti-termite treated area / structure free from termite. In addition to the 10 years guarantee furnished as above, the contractor shall have to furnish ten years (after certificate of final completion) Bank Guarantee Bond issued by any Nationalized Bank executed in favour of the client as directed in the prescribed proforma available in the tender document for an amount of 10% (ten percent) of cost of this item of work.
8Supplying and Filling with Sand in Foundation and Plinth in layers not exceeding 20 cm in depth, well watered and compact , top surface dressed and levelled to proper level and gradient including cost of all materials , conveyance,taxes, royalties, loading, unloading, cost of all labour, T&P, etc.All compelete as per the dirrection of Engineer-in-charge.
9PCC WORK: Providing and lying Plain Cement Concrete of proportion (1:3:6) in foundation & floor using 40 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge. Ground Floor
10PCC WORK: Providing and lying Plain Cement Concrete of proportion (1:3:6) in foundation & floor using 40 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge. Beyond 1.5 M to 4.5M Depth
11RCC WORK: Providing, lifting, hoisting and laying in position Machine Batched, Machine Mixed and Machine Vibrated Design mix Cement Concrete of M-20 Including the cost of Centering and Shuttering (minimum cement content not less than 347Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance, loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement. R.C.C. foundation and footing bases of columns mass concrete pre-cast slab etc. Beyond 1.5 M to 4.5M Depth
12-Do- R.C.C. Plinth Beam at Ground Floor
13-Do- R.C.C. Beams, columns, grider and bressmer etc.Ground Floor
14-Do- R.C.C. Beams, columns, grider and bressmer etc.Terrace Floor
15-Do- R.C.C. Floor and Roof slab 4.3Mtr. Height.Ground Floor
16-Do- R.C.C. Floor and Roof slab 4.3Mtr. Height.Terrace Floor
17-Do- R.C.C. stairs excluding landing but including railing.Ground Floor
18-Do- R.C.C. LintelGround Floor
19-Do- R.C.C. LintelTerrace Floor
20-Do- RCC Projecting sun shades and chajjas up toGround Floor
21-Do- RCC Projecting sun shades and chajjas up toTerrace Floor
22-Do- RCC Drain baseGround Floor
23-Do- RCC Drain WallGround Floor
24-Do- RCC Drain Slab CoverGround Floor
25Providing and fixing TOR Fe-500 HYSD reinforcement bars of required diameter for RCC works, including straightening, cutting, bending, binding, tying, hoisting, lowering, and placing in position as per approved design/drawings (BBS), with standard fan hooks. Rate includes all materials, labour, conveyance, loading/unloading, binding wires (18–20 gauge), T&P, and all incidental charges, complete as per Engineer-in-Charge.Note: (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement and payment). Ground Floor
26-Do- Terrace Floor
27Brick Work: Providing and laying Brick Masonry work in Foundation & Plinth using Fly ash bricks of 25 Cm. x 12 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:4) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. Ground Floor
28Brick work: Providing and laying brick masonry work in superstructure using fly ash bricks of size 25 cm × 12 cm × 8 cm, having crushing strength not less than 75 kg/cm² with dimensional tolerance ±2%, conforming to IS 12894 and IS 2212, in cement mortar (1:4) for half-brick masonry walls. The work includes provision for 2 nos. 6 mm dia MS bars at every 4th layer, after immersing the bricks in water for a minimum of 6 hours before use. All necessary projections, splays, cuttings, circular moulding, corbelling, etc., as per drawings are included. The rate includes cost of all materials, labour, conveyance, royalties, loading and unloading, scaffolding, staging, watering and curing, sundries, tools & plants (T&P), and all incidental charges, complete as per the directions of the Engineer-in-Charge.Note: Cost of steel reinforcement is excluded. Ground Floor
29Brick work: Providing and laying full-brick masonry work in superstructure using fly ash bricks of size 25 cm × 12 cm × 8 cm, having a crushing strength of not less than 75 kg/cm² with dimensional tolerance ±2%, conforming to IS 12894 and IS 2212, in cement mortar (1:6), after immersing the bricks in water for a minimum of 6 hours before use. The work includes all necessary projections, splays, cuttings, circular moulding, corbelling, etc., as per the drawings. The rate includes the cost of all materials, labour, conveyance, royalties, loading and unloading, scaffolding, staging, watering and curing, sundries, tools and plants (T&P), and all other incidental charges, complete as per the directions of the Engineer-in-Charge. Ground Floor
30-Do- Terrace Floor
316 mm thick cement plaster in cement mortar (1:4) on ceilings of roof slabs, stairs, landings, chhajjas, shelves, columns, beams, lofts, etc., including roughening, scraping, finishing smooth with wooden floats, grooves, beads, drip courses, scaffolding, curing, materials, labour, T&P, conveyance, royalties, and all incidental charges, complete as per Engineer-in-Charge. Ground Floor
32-Do- Terrace Floor
33Providing and applying 12 mm thick cement plaster in cement mortar (1:4) on the surface of half-brick masonry walls, including racking out joints, scraping and cleaning the surface, and finishing smooth using wooden floats, bars, etc., to proper plumb and level. The work also includes making grooves, beads, and drip courses to provide the required ornamental finish as per drawings. The rate includes the cost of all materials, labour, conveyance, loading and unloading, royalties, scaffolding, staging, watering before plastering, curing, sundries, tools & plants (T&P), and all other incidental charges, complete as per the directions of the Engineer-in-Charge. Ground Floor
34Providing and applying 12 mm thick cement plaster in cement mortar (1:6) on the surface of brick masonry walls (external even surfaces), including racking out joints, scraping and cleaning the surface, and finishing smooth using wooden floats to proper plumb and level. The work also includes making grooves, beads, and drip courses to provide the required ornamental finish as per drawings. The rate includes the cost of all materials, labour, conveyance, loading and unloading, taxes and royalties, scaffolding, watering and curing, sundries, tools & plants (T&P), and all other incidental charges, complete as per the directions of the Engineer-in-Charge. Ground Floor
35-Do- Terrace Floor
36Providing and applying 12 mm thick cement plaster in cement mortar (1:6) on the surface of brick masonry walls (internal even surfaces), including racking out joints, scraping and cleaning the surface, and finishing smooth using wooden floats to proper plumb and level. The work also includes making grooves, beads, and drip courses to give the required ornamental finish as per drawings. The rate includes the cost of all materials, labour, conveyance, loading and unloading, royalties, scaffolding, watering and curing, sundries, tools & plants (T&P), and all other incidental charges, complete as per the directions of the Engineer-in-Charge. Ground Floor
37Providing and applying 16 mm thick cement plaster in cement mortar (1:6) on the surfaces of brick masonry walls (internal uneven surfaces), including racking out joints, scraping and cleaning the surface, and finishing smooth using wooden floats, bars, etc., to proper plumb and level. The work also includes making grooves, beads, and drip courses to give the required ornamental finish as per drawings. The rate includes the cost of all materials, labour, conveyance, loading and unloading, royalties, scaffolding, staging, watering before plastering, curing, sundries, tools & plants (T&P), and all other incidental charges, complete as per the directions of the Engineer-in-Charge. Ground Floor
38-Do- Terrace Floor
39Providing average 25mm thick grading Concrete in C.C ( 1:2:2 ) using 6mm size crusher broken black hard granite chips using 2% water proofing cement compound (Make: Sika / Fosroc / Equivalent) after scraping and cleaning the roof surface and finishing smooth to proper slope and gradient including cost of all materials, conveyance, sundries,T&P watering and curing by ponding water over terrace slab etc. complete as per the direction of the Engineer-in-charge. Ground Floor
40-Do- Terrace Floor
41Plinth protection: Providing, laying and compacting Plinth Protection in approved design mix Plain Cement Concrete (P.C.C.) of Grade M-20 using machine batching, machine mixing and machine vibration with black hard crusher broken granite chips of approved quality, size and grading obtained from approved quarry, including cost of cement, aggregates, water, admixtures (as per IS 9103, wherever required), all materials, labour, T&P, machinery, conveyance, loading, unloading, royalty, watering, curing, compacting and finishing the exposed surface smooth to the required line, level, thickness and slope, including all incidental charges complete as per the drawings and direction of the Engineer-in-Charge. Ground Floor
42Providing and laying levelling course in Plain Cement Concrete (P.C.C.) of Grade M-15 using approved quality cement, sand and 20 mm and down graded black hard granite crusher broken stone chips obtained from approved quarry, including batching, mixing, hoisting, conveying, laying in position, ramming, compacting, dressing to the required line, level and slope, curing and finishing, including cost of all materials, labour, tools and plants, loading, unloading, conveyance, royalties, taxes and all incidental charges complete as per the direction of the Engineer-in-Charge. Ground floor
43Providing and installing two component acrylic modified cementitious waterproofing coating with Masterseal 551 /Equivalent over roof slab after carrying out pond test on roof slab, filling all defects, saturating the surface, mixing the products and then application in 2.0 mm thickness (1.8 Kg / sqm coverage rate for 1.0 mm thickness) in suitable layers complete in all respect, all materials, tools, plant & labour complete in all respect.Density 1850kg/m³ , Mix ratio (Powder to liquid) 3:1 by weight ,Water penetration Din 1048 1.5 Bar no leakage Potlife @ 25°C 2 hours & @ 40°C 30 minutes,Recoatable: 8-12 hours Elongation >42% (air) & >31% (under water),Tensile strength >20 kg/cm2 ,VOC content (HK prod code P10-17) 0.5 g/L (Sika/Fosroc/MYK/) First floor
44-Do- Terrace Floor
45Finishing works: Supplying and finishing the plastered surface of wall using Cement Based Wall Putty (Water Based) of approved make and quality and finished smooth and even surface to receive the paint including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc, all complete as per the direction of Engineer-in-Charge.(Make: Birla White/J K Wall Putty) Internal Putty at Ground floor
46-Do- Terrace Floor
47Providing and applying two coats of plastic emulsion paint of approved make, quality, and shade over one coat of wall primer of approved quality on internal plastered surfaces, including thorough brushing of the surface to remove dust, dirt, and other foreign materials, sandpapering, and priming. The rate shall include the cost of all materials, labour, conveyance, loading and unloading, scaffolding, staging, tools & plants (T&P), watering and curing, and all other incidental charges, complete as per the directions of the Engineer-in-Charge.Note: Colour and shade shall be approved prior to procurement and application.Make: Dulux / Nerolac / Berger / Asian Paints. Ground Floor
48-Do- Terrace Floor
49Providing and applying two coats of exterior-grade Weather Coat paint of approved make and shade over one coat of water-bound cement primer on the surface, including surface preparation. The rate shall include the cost of materials, labour, scaffolding, tools & plants (T&P), and all other incidental charges, complete as per the directions of the Engineer-in-Charge.Note: Colour and shade shall be approved prior to procurement and application.Make: Dulux / Nerolac / Berger / Asian Paints. Ground Floor
50-Do- Terrace Floor
51Providing and applying two coats of synthetic enamel paint of approved make and shade on the surface, including surface preparation. The rate includes the cost of materials, labour, conveyance, tools & plants (T&P), labour cess, and all incidental charges etc complete as per the directions of the Engineer-in-Charge.Note: Colour and shade shall be approved prior to procurement and application.Approved Make: Dulux / Nerolac / Berger / Asian Paints. Ground Floor
52-Do- Terrace Floor
53Flooring work: Providing and laying granite stone flooring using 19-20 mm thick granite stone slabs of approved quality, colour, and size above 0.4 Sq.m as per IS 14223, in stair treads and risers, over an underlayer of 20 mm thick cement mortar (1:4) (1 cement : 4 coarse sand) conforming to IS 1443. The work includes cutting to size, laying, and joining with white cement slurry and colouring pigment to match the shade, with typical half nosing and cutting grooves. The rate includes the cost of all materials, labour, royalties, loading and unloading, conveyance, sundries, watering and curing, and all other incidental charges complete, as per the directions of the Engineer-in-Charge.Note: Sample of granite tiles shall be approved prior to procurement and use. Ground Floor
54Providing and laying granite stone flooring in floors and landings using 19-20 mm thick granite stone slabs of approved quality, colour, and size above 0.4 Sq.m as per IS 14223, laid over an underlayer of 20 mm thick cement mortar (1:4) (1 cement : 4 coarse sand) conforming to IS 1443. The work includes cutting to size, laying, and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, and cleaning the surface with acid. The rate includes the cost of all materials, labour, conveyance, royalties, loading and unloading, sundries, watering and curing, tools & plants (T&P), and all other incidental charges, complete as per the directions of the Engineer-in-Charge.Note: Sample of granite tiles shall be approved prior to procurement and use. Ground Floor
55-Do- Terrace Floor
56Providing and laying granite stone tiles in dado/skirting using 10 mm thick granite stone slabs of approved quality, colour, and size up to 0.4 Sq.m as per IS 14223, laid to proper line, level, and slope over 12 mm thick cement mortar (1:3) (1 cement : 3 coarse sand) conforming to IS 1443. The work includes cutting to size, laying, and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, and cleaning the surfaces with acid. The rate includes the cost of all materials, labour, conveyance, royalties, loading and unloading, sundries, watering and curing, tools & plants (T&P), and all other incidental charges, complete as per the directions of the Engineer-in-Charge.Note: Sample of granite tiles shall be approved prior to procurement and use. Ground Floor
57-Do- Terrace Floor
58Providing and laying 600 mm × 600 mm vitrified tile flooring conforming to IS: 15622, of approved make, quality, shade, and colour, laid over a 20 mm thick cement mortar bed (1:4) (1 cement : 4 coarse sand). The work includes cutting tiles to required size, laying in proper line, level, and plumb, and filling joints with white cement slurry mixed with matching pigment, including cleaning the surface. The rate includes the cost of all materials, labour, tools & plants (T&P), loading and unloading, conveyance, royalties, watering and curing, and all other incidental charges, complete as directed by the Engineer-in-Charge.Note: Sample of tiles shall be approved prior to procurement and use.Make: Johnson / Somany / Varmora or equivalent. Ground Floor
59Providing and laying vitrified tile dado/skirting conforming to IS: 15622, of approved make, quality, colour, and size 600 mm × 600 mm, fixed up to the required height from floor level over an underlayer of 12 mm thick cement mortar (1:3) (1 cement : 3 coarse sand). The work includes cutting tiles to required size, laying in proper line and level, and filling joints with white cement slurry mixed with approved colouring pigment to match the shade and colour, including cleaning the surface. The rate includes the cost of all materials, labour, conveyance, royalties, loading and unloading, sundries, watering and curing, tools & plants (T&P), and all other incidental charges, complete as directed by the Engineer-in-Charge.Note: Sample of tiles shall be approved prior to procurement and use.Make: Johnson / Somany / Varmora or equivalent. Ground Floor
60Supplying and installing Aluminium System: - Fixed windows made out of ALUPURE/Equivalent make frame dimension of 39mm x 42mm for with corners mechanical joints. Alupure Aluminium Systems are extruded through Nalco Billets with 6063 T6 Grade. With complete wind load calculation as per IS:875(part-3).Almost unlimited choice of colours deu to finishing techniques such as anodising and powder finishing. The system can accomodate glass with 4/5/6/8/10/12/14/20 & 22mm. The profile manufacturer should have an authorised fabrication partner for windows assembling and installation. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets, bridging wedges and glass packers) & with suitable water draining system. Application of Silicon sealant from Inside / Outside of MCCOY /Dowcorning or equivalent. or Openable windows made out of ALUPURE/Equivalent make frame dimension of 39mm x 62.9mm & Sash dimension of 46mm x 92mm for with corners mechanical joints. Alupure Aluminium Systems are extruded through Nalco Billets with 6063 T6 Grade. With complete wind load calculation as per IS:875(part-3). Almost unlimited choice of colours deu to finishing techniques such as anodising and powder finishing. The system can accomodate glass with 4/5/6/8/10/12/14/20 & 22mm. The profile manufacturer should have an authorised fabrication partner for windows assembling and installation. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) & with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent. or Sliding windows made out of ALUPURE/Equivalent make frame dimension of 88mm x 40 & Sash dimension of 31mm x 61.5mm for with corners mechanical joints. Alupure Aluminium Systems are extruded through Nalco Billets with 6063 T6 Grade. With complete wind load calculation as per IS:875(part-3). Almost unlimited choice of colours deu to finishing techniques such as anodising and powder finishing. The system can accomodate glass with 4/5/6/8/10/12/14/20 & 22mm. The profile manufacturer should have an authorised fabrication partner for windows assembling and installation. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) & with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent. Ground Floor
61-Do- Terrace Floor
624 nos hinges,1 No door stopper , 1 No tower blot, 1 No martise lock (Door Size: 1000mm x 2400 mm)
63Supplying, fabricating, and fixing M.S. grills made of M.S. flats/square bars as per drawings and design, fixed in position to proper plumb, including one coat of approved quality metallic primer. The rate includes cost of all materials, conveyance, transportation, taxes, labour, sundries, tools & plants (T&P), and all incidental charges, complete as per the directions of the Engineer-in-Charge. Ground Floor
64-Do- Terrace Floor
65S.S. Railing: Supplying, fabricating & fixing of polished stainless steel (304 grade) items made out of pipes, angles, flats, plates, hollow tube, square pipe bracing as per approved design and specification, buffing, polishing etc. with cost, conveyance, labour in railing, parapet, staircase, space frame etc required for the work complete in all respect as per direction of Engineer-in-charge. Ground Floor
66Providing and fixing factory made single extruded WPC (Wood Polymer Composite) soliddoor/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Frame size 65 x 125 mm Ground Floor
67Providing and fixing ISI marked 32 mm thick flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak three ply veneering with vertical grains or cross bands and face veneers on both faces of shutters of approved design including cost of all door fittings and fixtures etc. complete (SOR-2022, Item-25.17.8) Ground Floor
68Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.
69Construction of granular sub-base by providing Grading VI close graded Material, spreading in uniform layers with motor grader on prepared surface, mixing by place in method rotavator at OMC, and compacting with vibratory power roller to achieve the desired density, complete as per clause 401
70Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces as per section 800 of MoRTH specifications for Road & Bridge works (5th revision) and instruction of Engineer in charge
71Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per Table 600.1,cement content not to be less than 150kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver and compacting with vibratory roller, finishing and curing asper Clause 601 of MoSRT&H Specifications for Road & Bridge works (4th Revision)
72Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing and as per Clause 602 of MoSRT&H Specifications for Road & Bridge works (4th Revision)
73Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408
74Providing and laying 600 mm x 600 mm Matt Finished Vitrified Floor Tiles confirming to IS : 15622 of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) Ground Floor
75Providing and laying of Glazed Ceramic Wall Tiles in dado/skirting confirming to IS : 15622 of approved make, quality, colour and size 600mm x 300mm upto required height from floor level fixed over an under layer of 12mm thick bed of cement mortar (1:3) (1 Cement : 3 Coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) (Make:Somany/Jhonson/RAK/kajaria) Ground Floor
76Providing and fixing factory made single extruded WPC (Wood Polymer Composite) soliddoor/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.Shold fast/lugs or SS dash fasteners shall be paid for separately). Frame size 65 x 125 mm Ground Floor
77Providing and fixing of solid plain flush door shutter 30mm thick WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with SS 304 Grade Matt Finished 3 Nos butt hinges of Size 100mm X 60mm X 2.5mm, 1 No 250mm X 16mm Aldrop,1 No 150mm x 16mm tower bolt,2 No 150mm length Door handle with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Make: WPC: Century / Black Cobra / Rajshri Plastiwood, Hardware Fittings: Godrej / Dorset / Link / Dorma) Ground Floor
78Providing and installing two component acrylic modified cementitious waterproofing coating with Masterseal 551 over roof slab after carrying out pond test on roof slab, filling all defects, saturating the surface, mixing the products and then application in 2.0 mm thickness (1.8 Kg / sqm coverage rate for 1.0 mm thickness) in suitable layers complete in all respect, all materials, tools, plant & labour complete in all respect.Density 1850kg/m³ , Mix ratio (Powder to liquid) 3:1 by weight ,Water penetration Din 1048 1.5 Bar no leakage Potlife @ 25°C 2 hours & @ 40°C 30 minutes,Recoatable: 8-12 hours Elongation >42% (air) & >31% (under water),Tensile strength >20 kg/cm2 ,VOC content (HK prod code P10-17) 0.5 g/L Ground Floor
79(ii) Electrical workks: Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Each lightpoint should have provision for ceiling rose and angle holder point. In all the rooms there shall be two types of switchboard- one for raw and the other one for inverter. The inverter switchboard shall include atleast one fan, one light and other emergency sockets. Each quarter shall have 2 separte Dbs- one for raw and the other one for inverter. GROUP-A(QTRS)
80-Do- GROUP-B(QTRS)
81-Do- GROUP-C(COMMON AREA)
82Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
83Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius ) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
84Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
85Supplying,fixing of 2 x 6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type) ( ( flame retradant type) with suitable size modular box & metallic cover plate (both side)( flame retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius )/Panasonic (vision)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
86Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (2X1.5+1X1.5)
87Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit. (2X2.5+1X1.5)
88Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit (2X4+1X1.5)
89Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit . (2X6+1X2.5)
90Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB c of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
91Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
92S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
93S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision)
94Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
95Supplying, installation, testing and commssioning of 1200 mm sweep Copper wound BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix /Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.( REGULATOR COMPATIBLE)
96SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .
97SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years
98Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved.
99Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years.(To be used in parking, corridor area etc.)
100SITC of energy efficient LED 60Watt,5700K LED well glass equiped with isolated electronics driver suitable for industrial application,,IP65,IK 10 ,110 lm/w medium bay heighted LED downlighter with all required accessories as required. (For area Lighting) (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)
101Supply and fixing of 16 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years (RAW DB)
102Supply and fixing of 8 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years (INVERTER DB)
103Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9./ABB SB 200 the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 years.
104Supplying and fixing 63 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB FB200 in the existing DB complete with connections as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year.
105Supplying and fixing 25 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA .Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9./ ABB FB200 in the existing DB complete with connections as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year.
106Supply and fixing of 63A 220V automatic over/under voltage, overload protection device with protection range 230-300V (Overvolatge), 80-210 V(Undervoltage), autoreconnect, adjustable device in complete as per the direction of Engineer-in-charge.Make-AMICI smart/Legrand/Siemens/Schneider/ABB
107Supplying and fixing 6-32 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year.
108(Earthing) INSTALLATION:- S/IT/C Of Earthing withG.I earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required as per direction of Engg.-in-Charge.
109Providing and fixing 6 SWG G.I wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge.
110Providing and fixing 25mm x 5 mm G.I strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
111Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Make-Polycab/KEI/Finolex/Havells/RR kabel/Gloster/V-Guard
112Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
113EXTERNAL ILLUMINATION For all the quarters: Supply of Elegant look 60 W AIO LED Solar Street lights having extruded alluminium housing, 180Wp or more (subjected to final panel backup calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) Mono Crystalline Panel/Laminates fixed on the top of the luminaire housing, maintenance free 12.8 volts 78 Ah or more (subjected to final battery calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) LiFePO4 battery(BIS certified) , BMS, MPPT charge controller, PIR sensor( when there will be no movement the lumens output will be 30% output).The solar panel and battery should be designed to provide 2 days (24 hrs ) back up . The luminaire is having IP 65 protection for critical components, IK 08 and having lumen output of >=10000 lumens as per LM 79 report third party/central/state govt accredited NABL lab to justify the lumen output & lumen efficacy . Lenses should be provided on the LED chip for better lighting dstribution to avoid glare on human eyes. Both the luminaire and Mono Crystalline Panel must be manufactured in India. The Solar lighting company must submit the third party central/state govt accredited NABL lab reports to justify the lumen efficacy,luminaire output , IK 08 and IP 65 protection.The Luminaire should be supplied along with adjustable type mounting bracket which can be fitted directly on the pole.The Solar lighting manufacturer must submit the declaration letter by mentioning that complete solar light and the solar panel are manufactured in India and warranty certificate on their company's letterhead by mentioning warranty period as 5 years and necessary aftersales Service will be provided through their tollfree base service network located within 100 KM from the project site. The Solar lighting manufacturer must submit the declaration letter by mentioning that complete solar light and the solar panel are manufactured in India and warranty certificate on their company's letterhead by mentioning warranty period as 5 years and necessary aftersales Service will be provided through their tollfree base service network located within 100 KM from the project site. The Solar Street light manufacturer should have own NABL accredieted laborotory. The following test reports must be submitted and approved from SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR for the technical acceptance of the products.1.LM 79 REPORT and LM 80 Report ( from third party/central/state govt accredited NABL lab of AIO solar light) , 2. IK 08 ( from third party/central/state govt accredited NABL lab of AIO solar light ) , 3. IP 65 (Report of third party/central/state govt accredited NABL lab of AIO solar light 4. EN50530 – MPPT Efficiency , 5. IEC61547 , 6. IEC61000-3-2 – EMC , 7. IEC 60598-2-3 ,8. IEC 62109-1, ( The necessary test reports of third party/central/state govt accredited NABL lab from sl no. 4 to sl no.8 must be submitted for any wattage of AIO solar light )Make-(Philips/Panasonict/Wipro/Crompton/Bajaj/Havells/LT ). NB: The cost includes 5 years CMC including repair/ Maintenance/ replacement of the product in case of any defect
114Installation of 6 mtr pole on the foundation after fixing the 60 W AIO Light in the pole by using suitable machinery by taking all safety precautions as per the direction of EIC.
115Supply of 6 mtr long hot dip galvanized Octagonal pole having base dia of 155 mm and top dia of 70 mm and plate thick ness of 4 mm or more. complete with base plate 260x260x16 mm and 4 nos. Jtype En 8 grade foundation bolts (M24X750 mm) to withstand 180 KM / HR or more wind speed considering the weight & dimension of 1 nos 60 W AIO Solar light to be fitted in the top of the pole .The bidder shall also furnish wind load test report of the solar fixture and wind load test of the pole considering the weight and dimension of 1 no 60 W AIO Solar light to be fitted in the pole to sustain wind speed of 180km/hr or more from third party /central/state govt accredited NABL lab after award of the work.( For solar)(Make - Bajaj/RR ispat//Valmont/Vakrangee/Utkarsh)
116Construction of RCC foundation by using M20 grade RCC and Fe415 grade reinforcement in the foundation by considering the SBC as 10 T Per sq mtr and fixing 4 nos. EN8 grade foundation bolts in that foundation and installation of the pole with solar light on that foundation using suitable machinery. The work shall be executed as per the instruction of Eng-in-charge. The structural calculation and civil foundation shall be duly approved by competant authority from civil wing before execution of the work.
117LIGHTENING PROTECTION SYSTEM--- Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB
118Supply of Roof conductor holder for parapet- PolyamideConductor holder:With M8 female thread or diameter 7mm, M8Screw to connect the conductor holder.Weather andtemperature resistant from -35 to +90 degree Celsius tested.Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB
119Supply of Polyamide roof cable holder for flat roof:DIN 48829 Form B1. Closed form with bottom. Filling weight1Kg (frost-resistant concrete). Sleeve from polyethylene, black@ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB
120Supply of Connector: For T cross and parallel connectors. Quickinstallation using hexagonal bolt M10X30 high-grade hot dipgalvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB
121Supply of 1 mtr vertical air terminal with mounting accessorieson the flat surface to meet the requirements of IS/IEC 62305.Tested for Electrical , mechanical and chemical as per IEC62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB
122Supply of Vertical air terminal with accessories:Providing of Air terminalsas per IS-IEC -62305 part-3Nominal size Ø10/16 mm aluminium rod:2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN48801) Suitable for high wind load.Tested as per IEC 62561. Make-OBO/Dehn/ABB
123Supply for Providing of Stand for Fang Fix system 16 kg with base andclamp ,made up of frost resistant concrete and clamp testedupto 100KA lightning current . Make-OBO/Dehn/ABB
124Supply for Providing of Stand for Fang Fix system 16 kg made up of frostresistant concrete. Make-OBO/Dehn/ABB
125Supply of Test Joint (Folding Clamp) suitable to connect 8mmround conductor and max by 30x3 mm GI strip as specified indrawing and directed by Engineer.Tested for 100kA lightning current. Make-OBO/Dehn/ABB
126Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr HeightFor Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB
127Supply of Galvanised Steel Flat 30X3 mm thickness from earthelectrode directly in ground as required. Flat conductor HotDipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB
128Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB
129Supply of flat conductor holder- Fit: FL 30, With mounting hole6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece fromhot-dip galvanised steel, Bottom section from polyamide, black.Tested as per IEC 62561. Make-OBO/Dehn/ABB
130Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB
131Supply of UL Listed maintenance free ,Low carbon coppercoated earth rod of 3 metre electrode having diameter of 17.2mm with copper coating thickness of 250micron tested as perIEC 62561-2 Make-OBO/Dehn/ABB
132Supply of universal clamp made of SS to connect rod with flatconductor Make-OBO/Dehn/ABB
133Supply of Earth conductivity enhancing mineral compound shall be of 25kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB
134Supply of The above arrangements shall be provided with Heavy dutyearth champer of 5000kg load bearing capacity to ensure thesafety of earthing system Make-OBO/Dehn/ABB
135Installation of The above arrangements including all accessories as per Direction of Engg. In charge.
136Portable Fire Extinguisher System Supplying, installation, testing and commissioning of CO2 type Fire Extinguisher 4.5 kg capacity confirming to IS: 2878 made from ISI marked seamless cylinder confirming to IS: 7285, fitted with ISI marked controlled valve confirming to IS: 3224, high pressure 1mtr discharge hose & horn complete with initial gas charged with carrying handle & wall mounting bracket as per direction of Engineer-in-charge. Make-Safex/Fireshield/Ceasefire/FLAMEKLOG
137Supplying, installation, testing and commissioning of ABC type fire extinguishers of 6 kg capacity including cost of all material & labour etc complete. Make-Safex/Fireshield/Ceasefire/FLAMEKLOG
138SIGNAGES: SITC flexyl of Photoluminescent based Glow-in-the-dark sheeting with luminious properties enclosed in a weather-proof UV stabilized film with UV screen printing by imported inks pasted over 3 mm Thick Cast Acrylic Sheet with the Protection of 3 mm Thick Cast Acrylic from Front side with stud type mirror screw with lifespan of 5 years, visible upto 4-6 hrs in total darkness for floor indication, fire exit, hydrant, hose reel, fire extinguisher, MCP, fire alarm panel, in case of fire, lift, alarm valve signages
139(iii) P.H. works: Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor c-pvc pipes and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge.In Ground floor (Supreme/Ashirvad/Oriplast) 20mm dia CPVC pipe
140-Do- 25mm dia CPVC pipe
14125mm UPVC ASTM Pipe in Ground floor
14232 mm dia UPVC ASTM pipe
14325mm UPVC ASTM Pipe in 1st floor
14440mm diaUPVC ASTM pipe
145Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.250mm thick wall In Ground Floor
146Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge. In Ground Floor
147Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge. 15mm dia CP Bib cock (FLR-CHR-5047N Jaquar make)
148-Do- 15mm dia CP 2 Way bib cock (FLR-CHR-5041N)
149-Do- 15mm dia long body Sink cock (Jaquar)-CON-CHR-357KN
150-Do- 15 mm dia CP L.B. Bib cock (CON-CHR-037KN)
151-Do- 15mm dia CP angle stop cock (FLR-ACR-5053N)
152-Do- 15mm dia C.P. wall mixture 3-in-one System (Jaquar make with provision for over head ShowerFLR-ANQ-5281N
153-Do- Single Lever Basin Mixer without PopupWaste with 450mm Long Braided Hoses(As Per Cat. No: Cat. No: KUP-CHR-35011BPM of Jaquar)
154-Do- 32mm dia CP on Brass Bottle Trap (As per Cat. No. ALD-CHR-769L250x190 of Jaquar)
155-Do- ELENA VERTICAL(Manual) JAQUAR WATER HEATER( ELM-WHT-3KWV010)
156-Do- 15mm dia CP piller cock (CON-CHR-021KN)
157-Do- 15mm dia CP flange
158-Do- 15mm Cp extention piece
159-Do- Double coat hook (AKP-CHR- 35761P Jaquar make)
160-Do- 25mm brass full way valve
161-Do- 32mm brass full way valve
162-Do- 40mm brass full way valve
163-Do- 125mmdia C.P.grating
164-Do- 15mm dia CP Health faucet -jaquar make-HSH-CHR-85537))
165-Do- 600mm X 125mm C.P glass shelf (CAN-CHR-1171N)
166-Do- 25mm CP towel rail (CAN-CHR-1111N)
167-Do- Shower Arm (SHA-CHR-477)
168-Do- Over head shower 150 x 150 square (jaquar OHS-CHR-1605 Make)
169-Do- C.P towel ring (CAN-CHR-1121NMI)
170-Do- Towel Rack 600mm long with Lower Hangers, Stainless Steel AKP CHR-35781PS of jaquar
171-Do- Corner shelf ACN-CHR-1173(Jaquar make)
172-Do- CP soap holder (CAN-CHR-1131N)
173Supplying all materials, labour, T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701--1996 including cutting holes through the tank and fixing mild steel ltubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting up to a height of 5 meters above ground level and placing the tank to the required position and providing 1st class Fly ash.Brick work in cement mortar (1:6) of 0.46mt. height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C.slab of size 1.60mt.x1.60mt. and 0.10mt. thick, R.C.C.beam of 0.25mt.x0.30mt. and 2.60mt. average length in cement concrete (1:2:4) using 12mm size h.g.chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge. 2000 litre capacity water storage tanks(3 Layer) in 1st floor-sintex make
174Supplying, fiting and fixing of 40 mm Ball Cock with Rod & Ball of approved make with ISI mark and fixing the same inside 2000 ltrs PVC Water Storage Tank including all cost of materials, labour, carriage, taxes etc complete.
175Supplying all materials,labour,T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No.13592/1992 to walls with nails,bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification,testing,earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of Engineer-in-charge. (Supreme/Ashirvad/Oriplast) 110mm dia U-PVC SWR Pipe
176-Do- 75 mm dia U-PVC SWR Pipe
177-Do- 110mm dia U-PVC Door Tee
178-Do- 110mm dia U-PVC Plain Tee
179-Do- 110mm dia U-PVC Door Bend
180-Do- 110mm dia U-PVC Offset without ear
181-Do- 110mm dia U-PVC 'P' trap
182-Do- 110mm dia U-PVC Plain Band
183-Do- 110mm dia U-PVC Cowl
184-Do- 110mm dia U-PVC clamp
185-Do- 75mm dia U-PVC Door Bend.
186-Do- 75mm dia U-PVC Plain Bend.
187-Do- 110x75mm dia Reducer
188Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge250mm to 375mm thick wall
189Supplying all materials, labour, T&P and cutting holes in R.C.C roofs,comice etc for passing HCI Pipes/U.P.V.C Pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concre(1;2;4) includeing finishing complete so as to make it leak proof as per direction of the Engineer in charge.
190Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in chargea.European water closet with ‘S’ trap plain (Parrywere/Hindware/Nicer Make) (a)EWC (Jaguar LYRIC Make -LYS-WHT-38851P180UFSM
191Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink with outlet at end and weir overflow including fitting and fixing a pair of cast iron or MS brackets painted white, fixing 50mm/40mm dia CP brass waste, fixing 50mm/40mm dia PVC waste pipe 910mm long with supply of wooden plugs, screws and cement etc including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge600x450x250 mm stainless steel kitchen sink-glossy-IS:13983 - 1994 (Jayna make)
192Supply all materials and labour for fitting and fixing of following size white glazed vitreous chinaHalf Padestal wash hand basin of approved make in all floor of approved quality including cutting the walls & floor and making good the damages with cement concrete (1:2:4) etc. including all taxes, duties, transportation etc. all complete as per direction of EIC. (Make:JAQUAR/HINDWARE/CERA/PARRYWARE)Half pedestal basin FNS-WHT-40801 Wall Hung Basin with Fixing Accessories Size: 620x480x185 mm & FNS-WHT-40305Half pedestal with Fixing Accessoriesfor 40801
193Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge Design Mirror
194Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge. In ground floor Toilet A & C
195Supplying all materials, labour, T&P and providing cement concrete ( 1:3:6 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. in ground floor Toilet A & C
196Supplying all materials, labour, T&P and providing cement concrete (1:2;4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royality, taxes etc all complete as aper specification and direction of the E.I.C. Ground floor Toilet A & C
197Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge
198Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter.
199Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:1.5:3) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, fly ash bricks in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI/P-trap gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in chargeInside size 250mmx250mm
200Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in chargeInside size 760mmx760mmx460mm
201Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in chargeInside size 910mmx910mmx910mm
202Cost of R.C.P.C.Cover.
203Supplying all materials, labour, T&P and constructing soakway pit of the following size with precast RCC rings joined loose, gravel backing in the rear of well steining, precast RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including cutting hole in the rings for inlet pipe,earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge 1.22m dia x 2.10m deep soakway pit
204Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. 110mm dia u-pvc pipe alround concrete
205-Do- 160mm dia u-pvc pipe alround concrete
206Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation(G.I/P.V.C/M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only Labour for drilling of 200mm dia bore from '0' mtr. to '30' mtr.
207-Do- Labour for drilling of 150mm dia bore from '30' mtr. to '150' mtr.
208Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. Lowering of 200mm dia GI/P.V.C/MS casing pipes 0 mtr to 30 m
209Cost of 200mm dia P.V.C schedule-80 pipe
210Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge By DTH/Rotary Rig
211Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing,commissioning,trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge. 2 H.P single phase submerssible pump set
212-Do- DOL control panel
213-Do- 2.50sqmm cable
214-Do- 32mm dia steel short piece
215-Do- Steel rope
216-Do- Bore cap
217-Do- 32mm dia HDPE pipes
218-Do- Rigid casing pipe for cable
219Labour charges for lowering of submesible pumpset with pipes and cables etc. with testing and commissioning at site.
220Supply all materials,labours,T&P and construction bore well protection chamber of the inside size 650x650x1000 height with cement concrete ( 1;3;6) using 40 mm size hard granite metal on foundation,1st class fly ash brickwork incement motar(1:3),with base cement concrete (1:2:4) useing 12 mm size h.g chips ,12 mm thick cement plaster (1:4) inside and out site ,R CC cover slab in (1:1.5:3) using 12 mm size h.g chips earthwork in excavation in all kinds of soil and refiling the cavity around the chamber including watering ,curing,convayance of all materials to worksite,payment of royalty,taxes etc all complete as per approved specification and direction of the engineer-in -charge. Bore well protection chamber.
221Construction 1 nos 30 users RCC Septic tank Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge.
222- do - with addl. Depth of 1.5 m
223Excavation of foundation in laterite rock or any hard rock (other than granite or disintegrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.50 mtr. in depth and depositing the soil within initial lead of 50 mtr. and as per specification approved by the Department.
224Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge In ground floor
225Supplying all materials, labour, T&P and providing cement concrete ( 1:3:6 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. In ground floor
226Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge Base,Wall & Top Slab
227Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge Base,Roof Slab & Side Slab
228-Do- For RCC wall
229Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor
230Supplying all materials,labour,T&P and providing 6mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. Floor & I/s, O/s Wall
231Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
232Supplying all materials, labour, T&P and fitting and fixing S.W.Tee of size 160mx160mx160m as per P.H.D.specification and direction of the E.I.C.
233Supplying all materials, labour, T&P and constructing vent base as per P.H.D specification etc all complete.
234Supplying all materials, labour, T&P and fitting and fixing UPVC SWR soil waste ventilating pipes and fittings to walls with nails, bobbins and wooden plugs or laying in trenches including earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. 110mm diameter U-PVC SWR pipe
235-Do- 110mm dia U-PVC Plain shoe bend
236-Do- 110mm dia U-PVC Cowl
237Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge
238CONSTRUCTION OF 10000 LTR RCC SUMP 1nos: Earthwork in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to minimum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer in charge.
239Earthwork in excavation of foundation in stonety earth mixed with gravel within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to minimum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer in charge. 1st Extra lift
240Supplying all materials, labour, T&P and providing filling sand including watering, ramming and conveyance of all materials to site.
241Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 40mm H.G metal including watering, curing and conveyance of all materials to site.
242Supplying all materials, labour,T&P and providing cement concrete (1:1.5:3) for RCC work using 12mm HG chips including hoisting,laying,curring and conveyance of all materials to site etc complete. Base,Wall & Top Slab
243Supplying all materials, labour, T&P and providing brick work with Fly ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:3) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
244Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage. 1.00 qntl per cum
245Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor. RCC walls
246Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:3) including watering,curring and conveyance of all materials to site. Inside portion (1 no)
247Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site. (1no)
248Supplying all materials, labour, T&P and futting and fixing 20mm dia MS/CI step iron including supply of necessary C.C(1:2:4) for fixing etc complete as per P.H.D. specification. (1no)
249Supplying all materials, labour, T&P and cleaning of debries,uprooging and disposing at a safe distance all complete as per direction of the Engineer in charge Sweeper N.B: The amount put to tender is exclusive of GST. The intending bidders should offer their rate which shall be exclusive of GST as per norms. GST applicable onwards contract shall be paid over the bill amount at the time of payment of each bill. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57898572
AUTHORITY Government Departments
TENDER VALUE 98.31 Lakhs
LAST DATE 21-10-2026
Authority
Authority Name Rural Water Supply And Sanitation Division
Work Description Tender for Construction Of E Type Quarter At Rayagada Under Rwss Division, Rayagada In The District Of Rayagada For The Year 2026-27
Basic Detail
Tender No 03/RWSS/RGD/2026-27
Bidding Type Tender
Location
City Rayagada
State Odisha
Key Dates
Publish Date 07 Oct 2026
Submission Date 21 Oct 2026
Open Date 22 Oct 2026
Finance
Tender Value 98.31 Lakhs
Tender Fee 10000
EMD 98317
Exemption Available
Document List
01_SBD_ETypeQuater_03_2026-27.pdf
BOQ_612552.xls
c42a34c9-f3bd-49fc-b924-5744fe0eba08.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Oct 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
pdf

01_SBD_ETypeQuater_03_2026-27.pdf

xls

BOQ_612552.xls

html

c42a34c9-f3bd-49fc-b924-5744fe0eba08.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail