Defence Statutory Bodies & Commissions/Committees Closing in 5 days TDR #57898322

Tender For Repair/Maint Of External Water Supply Di/Ci/Gi Pipelines, Valve, Valve Pits, Gi Service Connection, Borewell,Pumps, Motors, Bleaching Dosing Plants, Starter, Electric Panels, And Supply Of Essential Chemical For Disinfection Of Water For W

Issued by Statutory Bodies & Commissions/Committees · Gorakhpur, Uttar Pradesh
Tender Value
50 Lakhs
Estimated cost
Bid Submission
26 Oct 2026
5 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gorakhpur → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of External Water Supply Di/Ci/Gi Pipelines, Valve, Valve Pits, Gi Service Connection, Borewell,Pumps, Motors, Bleaching Dosing Plants, Starter, Electric Panels, And Supply Of Essential Chemical For Disinfection Of Water For Water Supply Installation At Various Location Under Ge(Af) Gorakhpur .

BOQ

Name of Work:- REPAIR/MAINT OF EXTERNAL WATER SUPPLY DI/CI/GI PIPELINES, VALVE, VALVE PITS, GI SERVICE CONNECTION, BOREWELL,PUMPS, MOTORS, BLEACHING DOSING PLANTS, STARTER, ELECTRIC PANELS, AND SUPPLY OF ESSENTIAL CHEMICAL FOR DISINFECTION OF WATER FOR WATER SUPPLY INSTALLATION AT VARIOUS LOCATION UNDER GE(AF) GORAKHPUR .
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Garrison Engineer (AF) Gorakhpur Name of Work: REPAIR/MAINT OF EXTERNAL WATER SUPPLY DI/CI/GI PIPELINES, VALVE, VALVE PITS, GI SERVICE CONNECTION, BOREWELL,PUMPS, MOTORS, BLEACHING DOSING PLANTS, STARTER, ELECTRIC PANELS, AND SUPPLY OF ESSENTIAL CHEMICAL FOR DISINFECTION OF WATER FOR WATER SUPPLY INSTALLATION AT VARIOUS LOCATION UNDER GE(AF) GORAKHPUR . Contract No.: GE(AF)/GKP/E-61 OF 2026-27 File No. 9510/E8 Serial Page No.15 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of item Item Code / Make Quantity Units Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
2Disconnecting, removing from foundation staging to Centrifugal Pump/Motor of various Capacities from site and Transporting to nearest Workshop for repairing including returning back after repairing and Re-installation in Original Position and Re-connection in water supply installation & Testing complete all as specified and as directed by Engineer-in-charge. Note-Cost of repairs will be measured & paid separetely under respective item, here-in-after .
3Dismantling of Self Priming Non Clogging Centrifugal pump coupled motor of capacity 5HP Induction type & transporting to work shop for repair and replacement of defective worn out parts, heat varnishing and drying stator and rotor including overhauling of motor and pump and reinstaiiation all parts to original position with necessary testing and commissioning complete aii as directed. Note:- Reairs and replacement of old parts shall be measured and paid separately under relevant items given here in below incl taking out old parts.
4Suply only Ball bearing (DE) Part no. 260 or 261
5Suply only Rubber flap Part no. 4882
6Suply only Pump shaft Part no. 180
7Suply only Flat Gasket for shaft sleeve Part no. 515
8Suply only Shaft sleeve Part no. 261
9Disconnecting & taking out to Submersible Pump/Motor of various Capacities and lifting from bore hole of Pump Houses and Transporting to nearest Workshop for repairing including returning back after repairing and Re-instaltion & lowering in Original Position and Re-connection in water supply installation and Testing complete all as specified and as directed by Engineer-in-charge.Note-Cost of repairs will be measured & paid separetely under respective item, here-in-after.
10Dismantling to submersible Pump 20HP for repair & replace-ment of unserviceable spare-parts including necessary cutting, grinding, drilling, machine work for fixing of spares and re-assembling the Same and Tested in work shop , complete all as specified and as directed by Engineer-in-charge. Note:- (i) Defective spare parts (except bronze bushes) shall be measued & paid seprately under respective item of this shedule as supply only. But Fixing charges (Lbour element ) shall be deemed to be included in the unit rate of this item without any extra cost.
11All as per above here-in-before but 15HP
12Cutting & removing burn out motor winding of submersible pump set of capacity 15/20 HP pump set and cleaning complete & rewinding with superior quality of PVC insulated copper wire of same size & same gauge, weight and reassembling & testing complete as directed by Eng-in- Charge . Note-motor winding should be guarantee period for six month.
13Cutting & removing burn out motor winding of submersible pump set of capacity 25 HP pump set and cleaning complete & rewinding with superior quality of PVC insulated copper wire of same size & same gauge, weight and reassembling & testing complete as directed by Eng-in- Charge . Note-motor winding should be guarantee period for six month.
14Supply only thrust bearing/thrust plate for submersible pump set.
15Supply only motor housing bush (GM).
16Supply only Impeller bronze suitable for submersible pump set.
17Supply & fix GI steal wire rope 12mm dia submersible pump set including taking old/us steel wire rope.
18Supply only Sand Guard and water seal.
19Supply only Bowl packing
20Supply only Impeller shaft sleeves
21Supply only Impeller shaft (SS)
22Supply only Bowl bush (GM)
23Supply only Neckring (GM)
24Supply only SS coupling
25Supply only Stud
26S&F in replacement 10Sqmm 3 Core submersible cable flat copper conductor all as specified and directed.
27S&F in replacement 06 Sqmm 3 Core submersible cable flat copper conductor all as specified and directed.
28S&F in replacement star delta starter 3 phase 440V 28-42 amp rating fullyautomatic with enclosures. Model No CS96008 (MUG 30) of L&T or equivlent make specified in PS.E44
29S&F in replacement star delta starter 3 phase 440V 13-21 amp rating fullyautomatic with enclosures. Model No CS96008 (MUG 30) of L&T or equivlent of Legrand/Philips/Havells
30Taking out old U/S MCCB from LT panels & replacement with new MCCB 100 Amp, 415 V, 4 Pole 16 KA complete all as specified and directed.
31Taking out old U/S MCCB from LT panels & replacement with new MCCB 125 Amp, 415 V, 4 Pole 16 KA complete all as specified and directed.
32Supply and fixing in replacement of ammeter anlog flush type and selector switch for ammeter 0-100 Amp with CT coil analog flush type complete all as specified and directed.
33Supply and fixing in replacement of Voltmeter 0-500 Amp complete all as specified and directed.
34Supply and fixing in replacement of indicator Lamp LED type panel Lamp complete all as specified and directed.
35Dismatling old U/S non return valve of any size and replacement with new 150mm dia non return valve complete all as specified and directed.
36Dismatling old U/S non return valve of any size and replacement with new 100 mm dia non return valve complete all as specified and directed.
37M&L for repair of booster pump 2 HP centrifugal type complete including repalement of bearing , nut ,washer, gland doori etc all as spcified and directed of Eng-in-charge.
38M&L for repair of booster pump 1/0.5 HP complete including repalement of bearing , nut ,washer, gland doori etc all as spcified and directed of Eng-in-charge. Make Kirloskar KOEl or equivalent make specified in PS.
39S&F in replacement of gland packing for protecting water leakage from sluice valve and centrifugal pump set etc all as specified and directed of Eng-in-charge.
40S&F in replacement of hand wheel for opening and closing of sluice valve etc all as specified and directed of Eng-in-charge.
41S&Fchlorination Dozing pump single phase electrically operated 230 volts , 50 HZ ,fuse 1 amp with plastic suction and delivery piping solution tank maxm output 4.0 LPH Make -Unichlor of model no- UC-11,Sl no-60365 or equivlent make specified in PS.
42Supply, laying (in repair ) & testing XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volt grade of size 35 Sqmm 3.5 core complete all as specified and directed.
43Supply and laying DWC pipe SN-4 with coupler 40mm OD for cablre protection , ISI marked along with all accessories like socket, bend, couplers etc. Conforming to IS 14930, PartII complete with fitting and cutting , jointing etc. Laid in trenches/fixed to pole /laying under road crossing /fixed on pavement wall with clamps complete all as specified and as directed. Make Jindal/Telerex
44M&L packing pea gravel of size 2 to 4 mm of natural shape brought direct from river bed and packing around the casing pipe of mild steel to entire depth upto ground level including removal of soil around well and packing with gravel all as spcified and directed.
45Disconnecting electric connections and taking out submersible pump set of any capacity with column pipe of any length including cable for carring out development of bore well of any size and any length and lowering the same and connecting the electric cable after devolopment complete including testing for getting satisfactory discharge complete all as directed.
46M&L Flusing of borewell with compressed air with air compressor completely till the removed of sand, mud from the bore and till the clear water arrived . Flushing will be done with interval of 2-4 hours to the satisfaction of Eng-in-charge
47Dismantling and Material and labour for installation testing and commissioning wall mounted water level indicator electrically operated to show indication of 10 levels water in OHT including sensors and complete electrical connection up to pump house consisting of the following :-(a) Automatic multilevel visual indicator of 10 levels (Make-Benzer/Aqualift/Indian Engineering Co.(b) Sensor of steel 316-10 Nos.(c) Alarms.
48S&F in repair Gear motor complete 230 Volt 50Hz for Decrine Dozing pumps complete all as specified and directed.
49S&F in repair Motor assembling with bearing brackets and Tolerance for Decrine Dosing pumps , complete all as specified and directed.
50S&F in repair Coil 250 Volt 50 Hz for Decrine Dozing pumps, complete all as specified and directed.
51S&F in repair Single head feed rate control with Decrine Dosing pumps , complete all as specified and directed.
52S&F in repair Pump head (Ferrules 1/4 & duck bill included) for Decrine Dosing pumps complete all as specified and directed.
53S&F in repair Roller assembly for Decrine Dosing pumps, complete all as specified and directed.
54S&F in repair Pump tube for Decrine Dosing pumps , complete all as specified and directed.
55S&F in repair Injection check valve ⅜'' for Decrine Dosing pumps , complete all as specified and directed.
56S&F in repair Weighted suction line strainer ⅜ inch forDecrine Dosing pumps complete all as specified and directed.
57S&F in repair Size ⅜ inch white suction/discharge tubing for Decrine Dosing pumpscomplete all as specified and directed.
58supply ,installation ,testing and commissioning LT 415 volt 4 wire AC 50 HZ factory made out door type panel weather & vermin proof of 16 gauge thick MS black sheet spray painted two coats inside & outside with approved paint over a coat of primer ,floor mounted ,locking arrangement including suitable size brick duct in ground for cable two earth terminal suitable cable glands for all incoming and outgoing cable including grouting of panel 60 cm above ground level by providing 90 cm long angle 50x50x 6 mm welded on all the four corner embeded in PCC 1;2;4 USING 20 mm stone aggregate up to 30 cm necessary earth work complete all as specified and directed by Engr-in charge including the following accesssoriesusing lugs and glands for cable connection at Pump House all as specified and directed by EIC and providing of followings:- (a) Copper bus bar - 04 Nos 100 Amp ratings & 01 No 100AMP.(b)MCCB 63 Amp 4 pole 25 KA -01No(Make-L&T/Havells/Merlin Gerin) (Incoming)(c)TPN 4 POLE isolator 40 -01No(Make-L&T/Havells/Merlin Gerin) (outgoing)(d) Digital Volt meter, 3 ph,96x96 sqmm size suitable for voltage range 0-500 V -01 No (Make :- Conzerv/L&T)(e) Digital Ammeter, 3 ph,96x96 sqmm size suitable for range 0-100Amp CTS ratio 100/5 Amp -01 set(Make :- Conzerv/L&T)(f) Indicator lamp LED type of (RYB) set of 03 Nos with toggle switch-01 set (Make - L&T,SCI)(g) S & F MCB SPN 32 Amp cap -02 (Make- Protec/Havells/MDS)(h) S&F in replacement star delta starter 3 phase 440V 28-42 amp rating fullyautomatic with enclosures. Model No CS96008 (MUG 30) of L&T or equivlent of Legrand/Philips/Havells
59M & L For Cleaning of over head inside tank of capacity 0.1/1 lakhs gallon of staging 18 to 20 mtr height with scrubing on wall/ floors, removing of sludge, sand and washing with fresh water and bleaching powder including and painting the date of cleaning of tank ,cleaning of valve pits complete all as specified and directed.
60Material ,Labour & testing flanged pipe joints of 150 mm dia with 3 mm thick rubber gasket (packing ring) including provision of suitable size bolts, nuts and double washers complete all as specified and directed.
61Material ,Labour & testing flanged pipe joints of 100 mm dia with 3 mm thick rubber gasket (packing ring) including provision of suitable size bolts, nuts and double washers complete all as specified and directed.
62Material ,Labour & testing flanged pipe joints of 80 mm dia with 3 mm thick rubber gasket (packing ring) including provision of suitable size bolts, nuts and double washers complete all as specified and directed .
63Surface dressing n.exc 30 cm deep including cutting of bushes, grass etc complete all as specified and directed.
64M & L for Earthing complete with galvanized earth plate electrode 600 x 600 x 6 mm buried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to galvanised iron strip 32x6mm dia means of nut, bolts and washers made out of galvanized iron mild steel and 40 mm dia GI pipe \\"light grade\\" for protection of earth lead/Strip and connected to control board or main switch or as directed by Engineer -in-Charge including earthing pit in PCC (1:3:6) type C1 for chamber & Pre-cast RCC cover of size 380 x 380 x 40 mm with one handle made out of 8 mm dia round bar, 20 mm dia GI pipe light grade for watering funnels , wire mesh and provided charcoal or coke of alternative layers of 15 cm including necessary earth work complete.
65Taking out and S & F in replacement of new cast iron sluice valve with flanged of 150 mm bore dia end with stainless steel spindle and Cl wheel class PN 1.6 inc rubber gasket nuts bolts and washer for following size ISI marked conforming to IS 14848 (2000), complete all as specified and directed including necessary excavation or removing of sludge , water from pit.
66Taking out and S & F in replacement of new cast iron sluice valve with flanged of 100 mm bore dia end with stainless steel spindle and Cl wheel class PN 1.6 inc rubber gasket nuts bolts and washer for following size ISI marked conforming to IS 14848 (2000), complete all as specified and directed including necessary excavation or removing of sludge , water from pit.
67M&L chemical and bactirilogical testing of water and submission of report all as spcified and directed . Particular of test to be carried out (a) PH(b) odour© Taste (d) TDS (e) turbidity (f) total Hardness (g) sulphate (h) chloride (j) Resdiual free chlorine (k) M P N coliform bacteria Note:- Testing shall be carried out through a Government Laboratory/Government Agency as specified by the department and authenticated test report shall be submitted to the Engineer-in-Charge.The quoted rate shall include cost of collection of water samples, sampling containers, transportation of samples to and from the testing laboratory, laboratory/testing charges, sample handling, preparation and preservation, report charges and all other incidental expenses, conveyance and labour involved in carrying out the tests and submission of reports, complete in all respects as specified and directed.
68S & F for demolation of old unserviceable valve chamber and construction of new valve chamber of size 1m x 1m x 1 mtr with brick work comprising the following items complete all as specified and directed.(a) 150 MM thick PCC foundation (1:2:4) type B2 40 MM graded aggregrate.(b) Brick construction with (1:6) cement mortar and rendering 15 mm thick externally and internally complete fair face of brick works surface in cm (1:4).(c) MS cover of thickness 4 mm double door type welded to angle of soze 40 x 40 x 5 mm embedded in cement coping in PCC (1:2:4) tye B-0 wirh anchor fastner including looking arrangment complete with two coat of heighly corresive resistant apoxy point over one coat of red oxide primer.
69S & F M S rising pipe 150 mm dia as per ISI mark complete with flange joint with gasket & nut bolt as specified.
70S&F (in replacement) Water pressure Gauge 0-150 LBS/10.6 Kg complete water meter submersed in oil with brass stop cock all as specified and directedand taking out old one
71Cutting worn out winding of electric motor 3 phase of cap 7.5 HP and cleaning complete re- winding with superior quality of enameled copper wire same size, same gauge, weight and reassembling & testing, complete including replacement of bearings and terminal plate all as specified and directed.
72Cutting worn out winding of electric motor 3 phase of cap 12.5 HP and cleaning complete re- winding with superior quality of enameled copper wire same size, same gauge, weight and reassembling & testing, complete including replacement of bearings and terminal plate all as specified and directed.
73S & F DOL starter 3 phase of 7.5 HP, 415 volts MK 1.5, all as specified and directed.Make Havells/ L&T OR Equvilant .
74Excavation in trenches not exceeding 1.5mtr wide & not exceeding 1.5 mtr deep for laying pipe lines etc & getting out in soft /loose soil including forming bottom surface to required level or slope complete all as specified and directed by Engineer-in-charge.
75Returning , filling in trenches (Soft/Loose soil) in layers not exceeding 25 cm thick after laying of pipe including spreading, levelling & well ramming including watering as required all as specified and directed by Engineer-in-charge.
76Removing surplus excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above from the starting point all as specified and directed by Engineer-in-charge.
77M&L for 40 mm dia bore galvanised iron light grade for cable protection and sealing both ends complete all as specified and as directed.Make:- Tata/ Jindal/ Prakash Surya.
78M&L for cutting the existing hard standing/PCC/WBM road at a depth not less than 25CM in width for passing of cable through GI pipe , returning filling in, complete including finishing the surfaces by providing cement concrete (1:2:4) type B-2 (using 40mm graded stone aggregate ) up to 20 cm depth , finising to a uniform smooth surface to match the existing surface complete all as specified and directed. Note; (i) GI pipes shall be measured and paid separately (ii) Any damages made /caused to the HT/LT cables , Water supply pipe lines ,OFC cables etc during the excavation work shall be made good by the contr as per original & to the entire satisfaction of of Engr-in-charge. Cost of the same is deemed to be included in the unit quoted rates.
79Collection of water sample from the ETP of Aakash Vihar area(one sample of Raw sewage and one sample of treated water) and STP of Vijay Vihar area(one sample of raw sewage and one sample of treated water),in total four samples and testing of the same (bacteriological and chemical analysis) from the UP Jal Sansthan or any other Govt. recognized lab and submission of report to the department complete all as specified and directed.)
80M&L for Painting of pipe lines with two coat of synthetic enamell paint as per colour code after cleaning and removing existing dust and dirt on existing painted surfaces complete all as specified and as directed by Engineer-in-Charge. of 100 to 150mm bore horizontal Note:- The rate for scafolding etc deemed to be included in the quoted rates.
81Supply only water testing Kit with all accessories, samples in tubes from 0.1 ppm to 5 ppm from reputed manufacturer complete all as specified.
82Supply only Ortho Tollidine solution for water testing, in 500 ml bottles complete all as speicified.
83Supply only PH testing Kit with all accessories for swimming pool water from reputed manufacturer complete all as specified.
84Supply & Installed Float Switch device at DOL Starter for auto and manual operation of sewage Pump suitable for 7.5 HP , 3 phase motor complete all as specified and directed.
85Supply only PVC Hose pipe 50mm dia complete all as specified and directed
86Supply only Nylon rope 25mm dia suitable for suction sweeper
87Material and Labour for taking out /dismantling of Air blower pump set of rating 3 phase 440 Volts supply of capacity upto12.5 HP from ETP plant at any location and shifting the same to contractor's workshop for repair and re-installation/refixing the same at its original site and testing complete all as specified and directed by EIC .
88M&L for Cutting out the existing winding of the motor of capacity upto 20 HP, opening of winding, re-winding of motor with same size of rewinding with super enamelled copper winding including tapping, varnishing, baking and furnishing with the insulating sleeve and making connection complete all as specified and directed.
89Repairing of pump by re-threading of worn out studs holes and supply and fixing over size studs with nut and washer complete all as specified and dierected.
90Repairing of pump shaft by depositing metal on it by breazing, grinding and polishing to appropriate size of the shaft complete all as specified and directed.
91Supply and fixing gun metal/stainless steel bush of pump shaft complete all as specified and directed.
92Supply and fixing driven end bearing of blower shaft complete all as specified and directed.
93Supply and fixing end bearing of blower shaft complete all as specified and directed.
94Supply and fixing gland and packing complete all as specified and directed.
95Supply and fixing coupling with studs between motor & air blower complete all as speicifed and directed.
96Supply and fixing in replacement suction air filter complete all as specified and directed.
97Supply and fixing in replacement of suction silencer complete all as specified and directed.
98Supply and fixing Neck ring complete all as specified and directed.
99Supply and fixing bearing of motor shaft complete all as specified and directed.
100Material and Labour for taking out /dismantling of Air blower pump set of rating 3 phase 440 Volts supply of capacity upto 7.5 HP from plant at any location and shifting the same to contractor's workshop for repair and re-installation/refixing the same at its original site and testing complete all as specified and directed by EIC .
101Material and Labour for Cutting out the existing winding of the motor upto capacity of 7.5HP, opening of winding, re-winding of motor with same size of rewinding with super enamelled copper winding including tapping, varnishing, baking and furnishing with the insulating sleeve and making connection complete all as specified and directed.
102Material and Labour for taking out /dismantling of Air blower pump set of rating 3 phase 440 Volts supply of capacity upto 5.0 HP from plant at any location and shifting the same to contractor's workshop for repair and re-installation/refixing the same at its original site and testing complete all as specified and directed by EIC .
103Material and Labour for Cutting out the existing winding of the motor of capacity upto 5 HP, opening of winding, re-winding of motor with same size of rewinding with super enamelled copper winding including tapping, varnishing, baking and furnishing with the insulating sleeve and making connection complete all as specified and directed.
104Cutting out the existing winding of the motor of capacity upto 2 HP, opening of winding, re-winding of motor with same size of rewinding with super enamelled copper winding including tapping, varnishing, baking and furnishing with the insulating sleeve and making connection complete all as specified and directed.
105M & L for taking out unserviceable non clog submersible type raw effluent sewage lifting Submersible pump set of capacity upto 10 HP of rating 3 phase 440 Volts, from raw sewage collection sump/well of plant well upto 18 mtr depth ,for cleaning of muds , overhauling, Oiling,Greasing and servicing by Opening of all parts , bush ,bearing , rotor ,drum , bearing of motor shaft ,Neck ring, coupling with studs between motor & all other parts and re-assemble the same after greasing , oiling of and shifting the same to authorised workshop for repair , testing and re-installation/Re-fixing/lowering in the sewage sump complete all as specified all as directed by EIC. ( Note : - ( i ) Parts renewed shall be measured and paid separately under appropriate items ) (ii) Overhauling and servicing of non clog submersible Pump should be carried out by Auth company or dealer Which is specialist of above
106Attend the day to day complaint of non functing part to Air Blower , Air Blower Motor ,non clog submersible Pump, motor of any size ,type ,capacity and all connected parts .Note : - ( i ) Parts renewed shall be measured and paid separately under appropriate items ) (ii) Complaint Should be attend immediately within two hrs & Rectified the same day at the earliest without effecting of service .)
107Attend the day to day sewage complaint related leakege , choke , replacement of any part , with cutting ,jointing and any other work of GI Pipe ,MS Pipe , PVC Pipe for any size ,type ,capacity and any location rectified the same all as directed by EIC. ( Note : - ( i ) Parts renewed shall be measured and paid separately under appropriate items ) (ii) Complaint Should be attend immediately within two hrs & Rectified the same day at the earliest without effecting of service .)
108Material and labour for taking out the silt & foreign object , Cleaning & Removing sludge from course bar screen including all chamber of equilasation tank upto depth of 15 Mtr any capacity from ETP as per direction by EIC .
109Material and labour for taking out the silt & foreign object ,Cleaning & Removing sludge from Fine bar screen ,Oil & Grease Chamber with water pressure, bleaching powder etc complete with all as specified & direction by EIC .
110Material and labour for taking out the silt & foreign object ,Cleaning & Removing sludge from MBBR I & II Chamber with water pressure, bleaching powder etc complete with all as specified & direction by EIC .
111Material and labour for taking out the silt & foreign object ,Cleaning & Removing sludge from Tube Setteler Chamber with water pressure, bleaching powder etc complete with all as specified & direction by EIC .
112Supply and fix Plastic Media MBBR (Media) as per existing size & specification of IS and direction by EIC .
113Supply and fix in repair Pac media in tube settler tank as per existing specified size
114Replacement of sand filter media of sludge drying bed as per specification laid specification of IS , as per direction by EIC .
115Material and Labour for taking out unserviceable/burnt raw non clog submersible type raw effluent sewage lifting Submersible pump set of capacity upto 10 HP of rating 3 phase 440 Volts supply from raw sewage collection sump of ETP/Sewage plant at any location and shifting the same to authorised workshop for repair and re-installation/Re-fixing/lowering in the sewage sump complete all as specified and directed. (Parts renewed shall be measured and paid separately under appropriate items) listed here below :-
116Cutting out the existing winding of stator of submersible motor of any make and rewinding with water proof copper winding wire of appropriate guage as existing all as specified and directed.
117Straightening of the slots of stator of submersible motor of any make.
118Supply and fixing thrust bearing block complete of submersible pump of any make.
119Supply and fixing gun metal bushes for submersible motor as per manufacturer's design and specification.
120Supply and fixing sand guard of submersible motor.
121Supply and fixing of bronze metal impellars
122Supply and fixing of shaft sleeve
123Supply and fixing of set of gasket and O-ring
124Supply and fixing of Mechanical seal motor end.
125Supply and fixing of Mechanical seal pump end
126Supply and fixing deep groove ball bearing motor side
127Supply and fixing groove ball bearing pump side
128Supply and fixing pump casing
129Supply and fixing of intermediate casing
130Supply and fixing of bearing housing
131Supply and fixing of bearing cover
132Supply and fixing of shaft protection sleeve
133Supply and fixing of bowl, cast iron
134Supply and fixing of bearing sleeve complete
135Supply and fixing of rotor
136Supply and fixing of cable assembly
137S&F MCCB 160 Amps, 415 volts AC 50Hz, 3 pole, bracking capacity 36 kA ajustable thermal setting, with suitable size of sheet metal enclosure complete all as specified.
138S&F MCCB 200 Amps, 415 volts AC 50Hz, 4 pole, bracking capacity 36 kA ajustable thermal setting, with suitable size of sheet metal enclosure complete all as specified.
139Spray Concentrate Grass & weed, Grasses, Vines Brush Stumps Killer 41% Gyphosate grass burning chemical for all MES installation all as specified and directed.
140Supply and laying(in repair) DI pipes K-7 of 150 mm dia with flanged joint of ISI marked complete all as specified and directed.
141Supply and laying (in repair) DI pipes K-7 of 100 mm dia with flanged joint of ISI marked complete all as specified and directed.
142Supply and laying (in repair) GI pipes of 80 mm dia with flanged joint of ISI marked complete all as specified and directed.
143M&L construction of brick masonry valve pit of size 1050 mm X 1000 mm X 1000 mm (internal dimensions of chamber) depth to be reckoned from the top of PCC in foundation to top of MS cover with MS sheet cover 3mm thick including frame of angle iron 40 X 40 X 6 mm with locking arrangement and lifting handle including painting two coats of black synthetic enamel paint over a coat of red oxide primer etc including brick work in one brick thick wall in cement mortar 1:4, 15mm thick plastering in cement mortar 1:4 (internally on all brick wall and external upto 15cm below ground level) and necessary excavation and earth work in any type of soil, returning, filling in, disposal of surplus spoil to a distance not exceeding 50 mtr 15 cm thick PCC 1:4:8 type D-2 in PCC foundation projected by 15cm all round from the outer face of brick wall PCC 1:2:4 type B-1 in coping complete all as specified
144Supply and lay M S Pipes with flanged joints heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of size 150 MM including necessary fabrication if required of ISI marked complete all as specified and directed.
145Supply and lay (in repair) M S Pipes with flanged joints heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of size 100 MM including necessary fabrication if required of ISI marked complete all as specified and directed.
146Taking out UNSV cable of any sizeand making good disturbed surfaces of walls, floors etc to match with existing surfaces complete all as specified and directed.
147Supply, laying & testing XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volt grade of size 35 Sqmm 3.5 core complete all as specified and directed.
148Supply and laying DWC pipe SN-4 with coupler 40mm OD for cablre protection , ISI marked along with all accessories like socket, bend, couplers etc. Conforming to IS 14930, PartII complete with fitting and cutting , jointing etc. Laid in trenches/fixed to pole /laying under road crossing /fixed on pavement wall with clamps complete all as specified and as directed.
149Supply and laying Galvanized iron pipe light grade of dia 50 mm for cable protection in trenches /ducts/floor or fixed on walls /roof/poles etc including suitable fixing accessories complete all as specified and directed Make Tata /Jindal/prakash.Note:- Wherever the protection pipes are to be laid/fixed on poles/walls/other surface the cost of clamping using appropriate size/type of MS clamps ,nuts,bolts etc is deemed to be included in the unit quoted rates.
150M&L for cutting the existing hard standing/PCC/WBM road at a depth not less than 45cm and 25cm in width for passing of cable through GI pipe , returning filling in, complete including finishing the surfaces by providing cement concrete (1:2:4) type B-2 (using 40mm graded stone aggregate ) up to 20 cm depth , finising to a uniform smooth surface to match the existing surface complete all as specified and directed. Note; (i) GI pipes shall be measured and paid separately (ii) Any damages made /caused to the HT/LT cables , Water supply pipe lines ,OFC cables etc during the excavation work shall be made good by the contr as per original & to the entire satisfaction of of Engr-in-charge. Cost of the same is deemed to be included in the unit quoted rates.
151Supply and Repacking stuffing box of sluice valve spindle including taking apart and reassembling of size 80 mm complete all as specified and directed.
152Supply and Repacking stuffing box of sluice valve spindle including taking apart and reassembling of size 100 mm complete all as specified and directed.
153Supply and Repacking stuffing box of sluice valve spindle including taking apart and reassembling of size 150 mm complete all as specified and directed.
154Taking out sluice valves refacing, regrinding and refixing of size 80 mm all as directed by Engr -in Charge complete all as specified and directed.
155Taking out sluice valves refacing, regrinding and refixing of size 100 mm complete all as specified and directed.
156Taking out sluice valves refacing, regrinding and refixing of size 150 mm complete all as specified and directed.
157M&L for detection of leakage in 80 mm bore CI pipe line and taking out lead joints by burning/melting including supplying and refiling the Run lead joint with all fittings laid in floors or fixed to walls and ceiling etc including necessary fabrication,excavation and earth work if reqd complete all as specified and directed.
158M&L for detection of leakage in 100 mm bore CI pipe line and taking out lead joints by burning/melting including supplying and refiling the Run lead joint with all fittings laid in floors or fixed to walls and ceiling etc including necessary fabrication,excavation and earth work complete all as specified and directed.
159M&L for detection of leakage in 150 mm bore CI pipe line and taking out lead joints by burning/melting including supplying and refiling the Run lead joint with all fittings laid in floors or fixed to walls and ceiling etc including necessary fabrication,excavation and earth work complete all as specified and directed.
160Supplying,laying (in repair) and testing for 20mm bore GI tube medium grade ISI marked with necessary GI fitting such as elbow, union, reducer, tees, bends etc and short length complete laid in trenches/fixed on walls/ laid under floors complete all as specified and directed.
161All as above but 25 mm bore
162All as above but 40 mm bore
163All as above but 50 mm bore
164S & F in replacement of new cast iron sluice valve with flanged end with stainless steel spindle and Cl wheel class PN 1.6 inc rubber gasket nuts bolts and washer for following size ISI marked conforming to IS 14848 (2000),150 mm bore complete all as specified and directed including necessary excavation or removing of sludge , water from pit. all as specified and directed by Engineer-in-charge
165All as above but 100 mm bore
166All as above but 80 mm bore
167Cutting of road/hard standing for laying/dismentling of pipe line and making good disturbed surface and matching with the existing surface with cement concrete 1:2:4 not less than 75 mm in thickness on compacted sub base after laying of pipe line, complete all as specified and directed.
168supply & fixing gun metal gate valve with iron wheel head screwed both side for GI pipe 20mm bore sizes Make: Leader/Zoloto/Kirloskar
169All as above but 25mm bore
170All as above but 40mm bore
171All as above but 50mm bore
172M&L for repairing cast iron sluice valve flanged type of any make by dismantling the valve replacing the bolts nuts, washers, check nut, gaskets, spindle stainless steel suitable for 80 mm sluice valve wedgenut hand wheel set screw etc and reassembling and refixing the same in position including repairing the worn out gland packing and testing complete all as specified and directed for Sluice valve 80mm bore
173All as above but Sluice valve 100 mm
174All as above but Sluice valve 150mm
175Material & Labour & testing in replacement with 3 mm thick rubber gasket joint (packing ring) including provision of suitable size bolts, nuts,flanged joint and double washers complete for 200 mm dia all as specified and directed by the Engineer-in-charge:
176All as above but 150 mm dia
177All as above but 100 mm dia
178All as above but 80 mm dia
179Cutting of existing Cast iron pipes of 150 mm bore in position for insertion of new tees, branches etc including jointing with fittings complete all as specified and directed by Engineer-in-charge.
180Cutting of Cast iron pipes of 100 mm bore in position for insertion of new tees, branches etcincluding jointing with fittings complete all as specified and directed by Engineer-in-charge.
181Cutting of Cast iron pipes of 80 mm bore in position for insertion of new tees, branches etc including jointing with fittings complete all as specified and directed by Engineer-in-charge.
182Dismatling old U/S non return valve of size 150 mm and replacement with new 150mm dia non return valve complete all as specified and directed.
183Dismatling old U/S non return valve of size 100 mm and replacement with new 150mm dia non return valve complete all as specified and directed.
184Dismatling old U/S non return valve of size 80 mm and replacement with new 150mm dia non return valve complete all as specified and directed.
185Dismatling old U/S non return valve of size 50 mm and replacement with new 150mm dia non return valve complete all as specified and directed.
186S&F in replacement GI Elbow Threaded type of size 20 mm complete all as specified and directed by Engineer-in-charge.
187S&F in replacement GI Elbow Threaded type of size25 mm complete all as specified and directed by Engineer-in-charge.
188S&F in replacement GI Elbow Threaded type of size 40 mm complete all as specified and directed by Engineer-in-charge.
189S&F in replacement GI Elbow Threaded type of size 50 mm complete all as specified and directed by Engineer-in-charge.
190S&F in replacement GI Elbow Threaded type of size 80 mm complete all as specified and directed by Engineer-in-charge.
191S&F in replacement GI TEE Threaded type of size 20 mm complete all as specified and directed by Engineer-in-charge.
192S&F in replacement GI TEE Threaded type of size25 mm complete all as specified and directed by Engineer-in-charge.
193S&F in replacement GI TEE Threaded type of size 40 mm complete all as specified and directed by Engineer-in-charge.
194S&F in replacement GI TEE Threaded type of size 50 mm complete all as specified and directed by Engineer-in-charge.
195S&F in replacement GI TEE Threaded type of size 80 mm complete all as specified and directed by Engineer-in-charge.
196S&F in replacement GI SocketThreaded type of size 20 mm complete all as specified and directed by Engineer-in-charge.
197S&F in replacement GI Socket Threaded type of size25 mm complete all as specified and directed by Engineer-in-charge.
198S&F in replacement GI Socket Threaded type of size 40 mm complete all as specified and directed by Engineer-in-charge.
199S&F in replacement GI Socket Threaded type of size 50 mm complete all as specified and directed by Engineer-in-charge.
200S&F in replacement GI Socket Threaded type of size 80 mm complete all as specified and directed by Engineer-in-charge.
201S&F in replacement GI Socket Threaded type of size 100 mm complete all as specified and directed by Engineer-in-charge.
202S&F in replacement GI Union Threaded type of size 20 mm complete all as specified and directed by Engineer-in-charge.
203S&F in replacement GI Union Threaded type of size 25 mm complete all as specified and directed by Engineer-in-charge.
204S&F in replacement GI UnionThreaded type of size 40 mm complete all as specified and directed by Engineer-in-charge.
205S&F in replacement GI Union Threaded type of size 50 mm complete all as specified and directed by Engineer-in-charge.
206S&F in replacement GI Union Threaded type of size 80 mm complete all as specified and directed by Engineer-in-charge.
207S&F in replacement GI Union Threaded type of size 100 mm complete all as specified and directed by Engineer-in-charge.
208S&F in replacement GI Plug Threaded type of size 20 mm complete all as specified and directed by Engineer-in-charge.
209S&F in replacement GI Plug Threaded type of size 25 mm complete all as specified and directed by Engineer-in-charge.
210S&F in replacement GI Plug Threaded type of size 40 mm complete all as specified and directed by Engineer-in-charge.
211S&F in replacement GI Plug Threaded type of size 50 mm complete all as specified and directed by Engineer-in-charge.
212S&F in replacement GI Plug Threaded type of size 80 mm complete all as specified and directed by Engineer-in-charge.
213S&F in replacement GI Plug Threaded type of size 100 mm complete all as specified and directed by Engineer-in-charge.
214S&F in replacement GI Cross Threaded type of size 20 mm complete all as specified and directed by Engineer-in-charge.
215S&F in replacement GI Cross Threaded type of size 25 mm complete all as specified and directed by Engineer-in-charge.
216S&F in replacement GI Nipple Threaded type of size 20 mm complete all as specified and directed by Engineer-in-charge.
217S&F in replacement GI Nipple Threaded type of size 25 mm complete all as specified and directed by Engineer-in-charge.
218S&F in replacement GI Nipple Threaded type of size 40 mm complete all as specified and directed by Engineer-in-charge.
219S&F in replacement GI Nipple Threaded type of size 50 mm complete all as specified and directed by Engineer-in-charge.
220S&F in replacement GI CapPlug Threaded type of size 20 mm complete all as specified and directed by Engineer-in-charge.
221S&F in replacement GI CapPlug Threaded type of size 25 mm complete all as specified and directed by Engineer-in-charge.
222S&F in replacement GI CapPlug Threaded type of size 40 mm complete all as specified and directed by Engineer-in-charge.
223S&F in replacement GI CapPlug Threaded type of size 50 mm complete all as specified and directed by Engineer-in-charge.
224S&F in replacement GI CapPlug Threaded type of size 80 mm complete all as specified and directed by Engineer-in-charge.
225S&F in replacement GI Flange Threaded type of size 20 mm complete all as specified and directed by Engineer-in-charge.
226S&F in replacement GI Flange Threaded type of size 25 mm complete all as specified and directed by Engineer-in-charge.
227S&F in replacement GI Flange Threaded type of size 40 mm complete all as specified and directed by Engineer-in-charge.
228S&F in replacement GI Flange Threaded type of size 50 mm complete all as specified and directed by Engineer-in-charge.
229S&F in replacement GI Flange Threaded type of size 80 mm complete all as specified and directed by Engineer-in-charge.
230S&F in replacement GI Flange Threaded type of size 100 mm complete all as specified and directed by Engineer-in-charge.
231S&F in Replacement Strainer for suction of size 100 mm complete all as specified and directed by Engineer-in-charge.
232S&F in Replacement Strainer for suction of size 150 mm complete all as specified and directed by Engineer-in-charge.
233S&F in replacement Water level controller (16.4 feet cable) IP68 waterproof housing with sensitive microswitch alongwith all connectetd accessories all as spcified and directed.
234Supply only stable bleaching powder grade-B complete all as specified and directed.
235Supply only Chlorine Test Kit complete with orthotodoline solution (As per sample) complete all as specified and directed.
236Material & Laying for drilling, tapping cast iron water mains (in position) for branch connections of 20/25 mm bore GI Pipe, including saddle pieces, elbow,tee,reducer and nuts & bolts complete all as specified and directed by Engineer-in-charge.
237S&F Single Phasing Preventer contact rating 10 Amp, protrction degree IP40 and instantaneous type trip delay,415 V AC 50 HZ suitable for 3 phase pump starters complete all as specified and directed.
238M&L cleaning of RCC overhead reservoir of capacity 1.0 Lakhs gallons through Mechanical tank cleaning process by involving the following six(6) stages of cleaning process and as directed by Engr-in-charge:- Location - OP/NP Area & Tech Area a) De-watering by high pressure submersible pump all completeb) Total removal of sludges by suction pumps all complete.c) Cleaning of walls,ceiling and floor by high pressure jet of 80-180 bar pressure all completed) Removal of addl. sludge by industrial vacuum pump all complete.e) Antibacterial treatment of inside of tank to make it complete bacteria free and all complete.f) Treated with ultra violet radiatior to make it complete bacteria free all complete.Note:-(1) The entire work should be carried out by 6-Stage tank cleaning process by any franchises or M/S TANK CLEANING(Pvt) Ltd or any other MES approved firm having equivalent technology.(2) Entire T&P should be arranged by the contractor at their own.Only electric power & water shall be supplied by MES at stipulated rate.(3) (a) Date of cleaning ,(b) Capacity of tank should be written over the outer surface of tank by synthetic enamel paint with lettering not less than 100 mm height.Cost of the same is deemed inclusive in the quoted unit rate of cleaning of tank.
239S&F in repair Concussive BiB taps 25 mm size of cast copper alloy, screwed for iron pipe and fixed all as specified and directed.
240Material & Labour for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate all as specified and directed . Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57898322
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 50 Lakhs
LAST DATE 26-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of External Water Supply Di/Ci/Gi Pipelines, Valve, Valve Pits, Gi Service Connection, Borewell,Pumps, Motors, Bleaching Dosing Plants, Starter, Electric Panels, And Supply Of Essential Chemical For Disinfection Of Water For Water Supply Installation At Various Location Under Ge(Af) Gorakhpur .
Basic Detail
Tender No 9510/E8
Bidding Type Tender
Location
City Gorakhpur
State Uttar Pradesh
Key Dates
Publish Date 06 Oct 2026
Submission Date 26 Oct 2026
Open Date 28 Oct 2026
Finance
Tender Value 50 Lakhs
Tender Fee 500
EMD 1 Lakhs
Exemption Available
Document List
0756298b-d6c2-4a49-9bf6-d51c27140528.html
BOQ_888444.xls
tenderca61.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Oct 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

0756298b-d6c2-4a49-9bf6-d51c27140528.html

xls

BOQ_888444.xls

pdf

tenderca61.pdf

pdf

Tendernotice_1.pdf

Disclaimer