Defence Statutory Bodies & Commissions/Committees Closing in 1 days TDR #57898308

Tender For Repair/Maint Of Internal Electrification Work Services With Replacement Of Unsv Wiring Various Type Of Light Fitting And Fixtures, Distribution Board Submain Wiring Incl Maintenance Of Summer And Winter Appliances With Connected Items Of M

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
40 Lakhs
Estimated cost
Bid Submission
03 Nov 2026
1 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of Internal Electrification Work Services With Replacement Of Unsv Wiring Various Type Of Light Fitting And Fixtures, Distribution Board Submain Wiring Incl Maintenance Of Summer And Winter Appliances With Connected Items Of Md/ Otm At Dpdo Kwc Timarpur Under Ge(North) Delhi Cantt-10

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 27-Oct-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-Nov-2026

BOQ

Name of Work:- REPAIR/MAINT OF INTERNAL ELECTRIFICATION WORK SERVICES WITH REPLACEMENT OF UNSV WIRING VARIOUS TYPE OF LIGHT FITTING AND FIXTURES, DISTRIBUTION BOARD SUBMAIN WIRING INCL MAINTENANCE OF SUMMER AND WINTER APPLIANCES WITH CONNECTED ITEMS OF MD/ OTM AT DPDO KWC TIMARPUR UNDER GE(NORTH) DELHI CANTT-10
Sl. No. Item Description
1Taking out Unseviceable main switch DB,MCB DB existing Complete
2M&L for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for
3All as per the description of srl item No 02 here in before but One light point controlled by one switch of 6Amp
4All as per the description of srl item No 02 here-in-before but one fan point controlled by one, one way switch 06 Amps
5All as per srl item No 02 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch
6All as per the description of srl item No 02 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch
7All as per the description of srl item No.02 here in before but One bell point controlled by one bell push switch of 6Amp
8All as per the description of srl item No 02 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed
9M&L for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing through existing conduit pipe complete with replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for
10All as per the description of srl item No 04 here in before but One light point controlled by one switch of 6Amp
11All as per the description of srl item No 04 here-in-before but one fan point controlled by one, one way switch 06 Amps
12All as per the description of srl item No 04 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch
13All as per the description of srl item No 04 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch
14All as per the description of srl item No 04 here in before but One bell point controlled by one bell push switch of 6Amp
15All as per the description of srl item No 04 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed
16M&L for point wiring with single core FRLS, PVC insulated, unsheathed multi stranded copper conductor of size 1.5 sqmm alongwith 1.5 sqmm earth wire of multi strand copper conductor (with same specification) drawing through existing conduit pipe including replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete for the following :-
17All as per the description of srl item No 06 here in before but One light point controlled by one switch
18All as per the description of srl item No 06 here in before but One ceiling/exhaust fan point controlled by one switch
19All as per the description of srl item No 06 here in before but One socket outlet 5 Amps controlled by one switch on same board
20All as per the description of srl item No 06 here in before but One socket outlet 5 amps controlled by one switch on independent board
21All as per the description of srl item No 06 here in before but One bell point controlled by one bell push switch
22All as per the description of srl item No 06 above but wiring with 2.5 sqmm copper wire and 2.5 sqmm earth wire for socket out let 16 Amps on independent board
23S&F in repair Switch piano flush type 5/6 Amps single pole one way 230 Volts complete
24S&F in repairSwitch piano flush type 15/16 A single pole one way 230 Volts complete
25S&F in repair Socket Outlet 2 in 1, 3 pin 5 Amps flush type 230 Volt complete
26S&F in repair Socket Outlet 2 in 1, 3/6 pin 5 and 15 Amp flush type 230 Volts complete
27S&F in repair Bell push, flush type 5 Amps 230 Volts complete
28S&F in repair electronic fan step regulator fiush type 120 watt, 230 Volt complete
29S&F in repair lamp holder, 230 volt AC, PVC / Polycarbonate type with back plate suitable for batten fitting including 9 watt LED bulb inverter type upto 4 Hrs back up 6500 K complete all as specified & directed
30S&F in repair modular switch, 06 Amps, single pole, one way, 250 volts, one module and IP 20 protection complete all as specified & directed
31S&F in repair modular bell push with indicator, 06 Amps, single pole, one way, 250 volts complete all as specified & directed
32S&F in repair modular switch, with indicator, 16 Amps, single pole, one way, 250 volts, one module complete all as specified & directed
33S&F in repair modular socket outlet 05 Pin, 06 Amps, 02 module with shutter complete all as specified & directed
34S&F in repair modular socket outlet 02 in 01, 03 pin, 06 Amps and 16 Amps, 02 module with shutter complete all as specified & directed
35S&F in repair ceiling fan modular regulator, stepped type of 0 to 04 rotary steps, electronic, 02 module, humfree, AC, 230 volts, 100 watts, duly ISI marked complete
36S&F ding dong bell, AC, 230 volts, single pole complete all as specified & directed.
37S&F ceiling rose, 6 Amps, 250 volts, AC with three terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete.
38S&F in repair Thermostatic switch stainless steel, 120 Vac to 250 Vac, SPST, 0 degree C to 150 degree C, 32 Amps, DP complete all as specified & directed
39S&F in repair Thermostatic switch stainless steel ,120 Vac to 250 Vac, SPST, 0 degree C to 150 degree C, 15 Amps, DP complete all as specified & directed
40Supplying and laying in replacement or fixing or passing through pipe, 1100 volts grade PVC insulated copper stranded conductor cable, unarmoured, served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core cable flat or circuler for the following size of cables :-
416 Sqmm
4210 Sqmm
43S&F in repair surface/ceiling mounted inverter type LED panel type of size 2ft x 2ft, 36W, 230V, 5700K complete with driver full window glarefree opal diffuser LED panel with CRCA powder coated white housing complete with all accessories required for connection and making good the disturbed ceiling complete
44S&F in repair wall mounted LED batten with polycarbonate housing and initigrated electronic drive 20 watt fixture 4 feet provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete.
45S&F in repair wall mounted LED batten with aluminium housing and integrated electronic drive 20-Watt Emergency Inverter Batten| Reserve Plus 4-feet Rechargeable Inverter Batten ,Colour : Cool Day Light Provides up to 4-hour backup, Fully charges in upto 8 hours, 2600mAh long-lasting battery, Bright 100lm/watt outputand integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete
46S&F in repair surface and wall mounted LED batten 10 watt 2 feet long extruded aluminium housing provided for efficient heat dessipation with polycarbonate diffusser and integrated electronic drive, pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete.
47S&F in repair decorative wall mounting, brushed nickel finish fixture with Opal glass diffuser suitable with 9 W LED lamp B22 base.(Make of Bulb : Havells/Philips/ Wipro), and all accessories pre-wired including connecting up complete.
48S&F in repair LED Post top lantern luminaire with die cast aluminium spigot, lid cover and clear acrylic cover 45 watt, 5700 K with IP-65 protection incl connection complete.
49All as per the description of srl item No 31 but for 70 watt, 5700 K with IP-65 protection incl connection complete.
50S&F in repair inverter type LED Bulkhead luminaire of polycarbonate housing and enclosed with acrylic diffuser IP-65 protection incl connection complete.
51S&F in repair LED security light fitting of 45 watts with pressure die-cast aluminium housing complete with all accessories, fixing of fitting on wall with necessary fixing arrangement, IP66 protection as required at site & connection complete suitable for pole dia 40mm.
52M&L (in replacement) for LED security light with emergency backup 50W Models 5500 Lumen Battery capacity 12.8V, 12Ah Cool white 6500K LED Driver efficiency >90% (Battery to Load) made up of of pressure die cast aluminium housing with toughned glass and individual high power LEDs with secondary optics, IP 66 protection, clamp type suitable for 32-50mm dia bracket pipe, to be mounted on existing/ new GI bracket and connecting the street light fitting using 1.5 Sqmm PVC insulated copper cable complete all as directed. Note:- New GI bracket with clamp shall be measured & paid seperately
53S&F in repair exhaust fans AC single phase 230/240 V of size 300mm sweep steel body with louver and depositing old exhaust fan to MES store complete all as directed.
54S&F in repair Ventilating fan, wall mounted type of 250 mm sweep, 240 volts, AC, 50 Hz capacity, cutting of hole in wall, making of wooden frame/all required arrangement for mounting of fan including making good of disturbed surface etc complete.
55M&L in repair for submain wiring with three core (submain) PVC insulated cable with 4 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 4 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 25 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making disturbed surfaces complete
56All as per the description of srl item No 37 above but with 6 sqmm and 6 sqmm as earth wire with 32mm dia
57S&F in repair MCB DB, single pole and neutral with 200 Amps rated bus bar, 230 volts, glazed, double door type, IP-43, including connecting all connections of wire to MCBs with proper lugs & making good to the disturbed surface complete for the following no of way :-
584 way
598 way
6012 way
61S&F in repair sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts, 04 ways with 200 Amps rated copper bus bar and metal door with IP 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed and comprising of the following:- (a) MCCB, 100 Amps, 04 pole, AC, 415 Volts of 16 KA breaking capacity complete - 01 No. (b) MCB, SPN/SP 63A, AC,240 volts - 04 Nos.
62S&F in repair MCB, DP/SPN, 240 Volts, AC of breaking capacity 10 KA, 'C' curve and connections by using suitable copper lugs complete of following rating :-
6363 Amps
6440 Amps
65S&F in repair MCCB 4 Pole, 415 volt, AC, fixed type, with breaking capacity 16 KA suitable for load line DB & connection complete of following rating :-
6663 amps rating
67100 amps rating
68S&F in repair MCB, SP, AC, 240 volts of 6 to 32 Amps capacity \\"C\\" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
69M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete all as specified and directed.Note:- testing of earthing after completion is in permissible limit obtained with out making extra cost.
70S&F in repair AC single phase static energy meter of accuracy class 1.0, 240 V 50 Hz with Backlit LCD display of rating 10-60 A (measures and displays KWH,V,Current I, KW, pf last month history of KWH, MD in KW) with special features like TOD, temper logging, optical communication port display in absence of power with transparent hinge type box and depositing old meter to MES store complete all as directed.
71S&F in repair sheet metal enclosure with Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 'C' curve, 240 Volt complete
72S&F in repair fans ceiling complete with blade ,down rod,electronic type regulator and accesoories 230 V, 1200 mm sweep. BLDC ,min air delivery 210 CFM with service value 6 BEE 5 star rated with brushless direct current motor energy saving and depositing old ceiling fans to MES store complete all as directed.
73Supply of Bosch Professional Angle Grinder, Model GWS 900-100 (Model No. 0 601 396 0F1) or equivalent, rated input power 900 W, 230 V AC, 50 Hz, 100 mm disc capacity, no-load speed 11,000 RPM, M10 spindle thread, complete with protective guard, auxiliary handle, spanner/wrench, one heavy-duty plastic tool box, one pair of industrial safety hand gloves, five (05) metal cutting wheels (100 mm) and five (05) grinding wheels (100 mm), complete in all respects as directed by Engineer-in-Charge
74Supply and laying or fixing or passing through pipe in repair of 1100V grade, heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 10 sqmm 2 core nominal cross section complete
75S&F in repair wall mounting fan 400/450 mm sweep, adjustable, plastic blade grill for protection, pull cord control for speed and oscillation on-off, ABS body incl connection complete all as directed
76S&F (in replacement) LED landscape bollard outdoor garden light 10 watt, 230 volt, inverted pyramid tripod type with soft 360 degree distribution,600mm long IP-65 protection, incl necessary civil work for grouting & foundation work of suitable sizewith PCC work complete all as specified and directed
77S&F in repair PVC flexible twin twisted copper conductor cable multi strand of size 0.5 sqmm nominal cross section complete Please Enable Macros to View BoQ information
78S&F in repair PVC flexible twin twisted copper conductor cable multi strand of size 0.5 sqmm nominal cross section complete Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57898308
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 03-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of Internal Electrification Work Services With Replacement Of Unsv Wiring Various Type Of Light Fitting And Fixtures, Distribution Board Submain Wiring Incl Maintenance Of Summer And Winter Appliances With Connected Items Of Md/ Otm At Dpdo Kwc Timarpur Under Ge(North) Delhi Cantt-10
Basic Detail
Tender No GE/North-134/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 27 Oct 2026
Submission Date 03 Nov 2026
Open Date 05 Nov 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Available
Document List
38a59d3b-a84e-4a2d-b82e-e650a87d96a4.html
BOQ_888813.xls
Gen134.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 03, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 1 day
Nov 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Nov 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

38a59d3b-a84e-4a2d-b82e-e650a87d96a4.html

xls

BOQ_888813.xls

pdf

Gen134.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender