Tender For Provn Of Nine Omqs For Sqn Ldr And Above At Airforce Station Gurgaon
Tender Value
6.10 Crore
Estimated cost
Bid Submission
10 Nov 2026
15 days left
EMD
6.32 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gurgaon → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Nine Omqs For Sqn Ldr And Above At Airforce Station Gurgaon
BOQ
| Sl. No. | Item Description |
| 1 | SCHEDULE `A' PART - I (Building Works) is not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only. |
| 2 | Construction of Single storey building for Offr md accn for one officer (Air Cmde) including servant qtr and garrage including internal services with permanent specifications complete all as specified and shown on drawings. |
| 3 | Construction of double Storey (G+1) building for Offr md accn for 04 officers qtrs (Sqn Ldr and above) including servant qtr and garrage including internal services with permanent specifications complete all as specified and shown on drawings. |
| 4 | Construction of Garbage bin with permanent specifications complete all as specified and shown on drawings. |
| 5 | NOTE: Schedule ‘A’ Part II to XVI under Ser No 2.01 to 2.08 are Prepriced by MES. |
| 6 | Lump sum price worked out by the Contractor for “SITE CLEARANCE, EXCAVATION AND EARTH WORK” as listed in Schedule ‘A’ Part II |
| 7 | Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY WORK\\" as listed in Schedule ‘A’ Part III |
| 8 | Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION WORK\\" as listed in Schedule ‘A’ Part IV |
| 9 | Lump sum price worked out by the Contractor for “ROAD, PATH AND HARDSTANDING WORK\\" as listed in Schedule ‘A’ Part V |
| 10 | Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL WORK” as listed in Schedule ‘A’ Part VI |
| 11 | Lump sum price worked out by the Contractor for “AREA DRAINAGE WORK” as listed in Schedule ‘A’ Part VII |
| 12 | Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY WORK” as listed in Schedule ‘A’ Part VIII |
| 13 | Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY WORK\\" as listed in Schedule ‘A’ Part IX |
| 14 | Lump sum price worked out by the Contractor for “HOT WATER SUPPLY WORK” as listed in Schedule ‘A’ Part X |
| 15 | Lump sum price worked out by the Contractor for “SECURITY WALL WORK” as listed in Schedule ‘A’ Part XI |
| 16 | Lump sum price worked out by the Contractor for “STEEL GATE WORK” as listed in Schedule ‘A’ Part XII |
| 17 | Lump sum price worked out by the Contractor for “VERMICOMPOST WORK” as listed in Schedule ‘A’ Part XII |
| 18 | SCHEDULE `A' PART - XIII MISC ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only. |
| 19 | \\"INTERNAL WATER SUPPLY WORK\\" |
| 20 | S&F Brass Chromium Plated Central Hole Mixture 15mm bore (dia) without Popup Waste System with 450mm long provided Hoses including Flange suitable for Wash Hand Basin, complete all as specified and directed by Engr in Charge. |
| 21 | \\"INTERNAL ELECTRIFICATION WORK\\" |
| 22 | Supply and fix blank plate one module all as specified. |
| 23 | Supply and fixing Metal flush box 8 module all as specified and directed. |
| 24 | Supply and fix, LED bulb 7 Watt, all as specified and directed. |
| 25 | Supply and fixing LED light fitting with high out put diffuser squre type, 05 watt 220 V AC decorative type including connecting up with three core flexible copper cable of suitable size complete all as specified and directed. |
| 26 | Supply and fixing LED building security light fitting 25 Watt 230 V AC outdoor type with high-pressure die-cast aluminium housing and heat-resistant complete with driver, lamp bracket, with impact and corrosion-resistant, including thermal management in multiple optics, complete with IP 65/66 protection all as specified and directed. |
| 27 | Supply and fix TV coaxial connector type F-1 modular designed for cable installation of white colour combines functionally with a sleek design complete all as specified and directed by Engineer-in-charge. |
| 28 | \\"ROAD, PATH AND HARDSTANDING WORK\\" |
| 29 | M & L for applying 2mm thick thermoplastic road marking compound of white/yellow of approved make, shade for road marking of any width & girth & painting lines, dashes, arrows etc on bitumen road/pavement & on concrete surfaces using hot processor plant including removing old paint by paint remover or burning of blow lamps & cleaning with scrapers for removing all dirt/dust & other foreign matters at site & managing traffic control etc complete all as specified and directed of Make: Apco track of Asian or equivalent in Shalimar/Berger lewis/Nerolac/Johnson & Nicholson.complete all as specified and directed by Engr in Charge. |
| 30 | \\"AREA DRAINAGE WORK\\" |
| 31 | Supplying and fixing FRP (Fiber Reinforced Plastic) drain cover slab (size = 1000mm x 450mm x 5mm) of approved make, designed for a minimum load capacity of 2.5 tons, manufactured from high-strength fiberglass reinforced resin, complete with anti-skid surface, corrosion and UV resistance, lightweight, non-conductive, and maintenance-free, including all fittings, seating on drain/concrete ledge, testing, and installation, complete as per specifications and directions of Engineer-in-Charge. |
| 32 | \\"EXTERNAL WATER SUPPLY\\" |
| 33 | Supplying, and laying and testing in trenches, jointing/connecting and testing 80mm bore ductile iron pipe class 'K-7' with spigot and socketed ends, centrifugally cast suitable joint complete, all as specified and directed by Engineer-in-Charge. |
| 34 | Cutting the existing CI/DI pipe bore and inserting one Tee 100mm x 100mm x 80 mm including connecting pipes, collars etc. complete including necessary excavation and earthwork complete all as specified and directed. |
| 35 | Cutting DI/CI 80 mm dia pipes inserting Tee/elbow and reducing to required length before laying of size 50 mm complete, all as specified and directed. |
| 36 | M&L for construction of valve pit chamber 60 cm x 60 cm x 60 cm internal dimension with 10 cm thick foundation using PCC 1:4:8 type D-2 over 10 cm thick hardcore, 20 cm thick PCC block wall built in cement and sand mortar 1:4, 15 mm thick internal plaster including top of floor in cement 1:4, 15 mm cement, 1.4 mm thick MS sheet cover with 20x20x4 mm flat iron hold fast, hinges, handle, locking arrangement and applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surface including disposal of surplus soil of to a distance of n.exc 50 m complete all as specified and directed. |
| 37 | \\"SEWAGE DISPOSAL WORKS\\" |
| 38 | M&L for Construction RCC septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in walls, base slab, baffle walls and roof slab including beams etc. with vent shaft, manhole opening with cover connection etc., complete with effective depth of 1.5 mtr and overall depth 3 meter for 100 users with upflow filters etc., all as specified and shown on drawing complete, all as specified and directed by Engineer-in-Charge. |
| 39 | M&L for Construction of soakage well in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring and solid in M-25 concrete including intercepting chamber, screen chamber brick work in CM, RCC cover slab in M-25/RR masonry/SFRC cover, interconnecting pipes of RCC/DWC, complete filled with brick bats, complete of size 1.8 M × 3.0 m deep. |
| 40 | \\"STREET LIGHT WORK\\" |
| 41 | Supply and fix LED street light fitting of not less than 90 watt, LED having 6000K/3000K CCT of IP 66 protected luminaire with high power LED enclosed in pressure die-cast aluminium frame IK-07, alongwith GI pipe 40 mm dia medium grade of length not less than 2.5 RM bend to an angle as per site directions, fixed to the pole/ Wall with MS clamp made up of 40 x 6 mm flat, nut, bolts, washers, etc complete all as specified and directed. |
| 42 | S&F SMC based outdoor type Junction Box pole mounted having four Nos aluminium bus bar 100 Amps for cable connections and looping including MCB SP 06 Amp, C Curve, 10 kA, fixed to pole/wall with necessary clamps, nuts, bolts etc., complete all as specified and directed. |
| 43 | \\"EXTERNAL ELECTRIC SUPPLY WORKS\\" |
| 44 | Supply, installing, testing and commissioning factory made and tested LT Feeder Panel Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-65/66) and made of 3.15 mm thick CRCA SHEET & suitable channel mounted MCB 100mm Aluminium, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. The scope of work also comprising of the following:- (Main Panel)INCOMING MCCB 350 A 36 KA 4 POLE THERMAL MAGNETIC Release – 1 SetOUTGOING MCCB 200 A 25 KA 4 POLE THERMAL MAGNETIC – 3 SetMCCB 63 A 16 KA 4 POLE THERMAL MAGNETIC – 1 SetDIGITAL VOLT METER (0-500V) – 1 SetDIGITAL AMP METER (0-600A) – 1 SetVOLT METER SELECTOR SWITCH – 1 SetAMP METER SELECTOR SWITCH – 1 SetINDICATING LIGHT RED 220V AC – 1 SetINDICATING LIGHT YELLOW 220V AC – 1 SetINDICATING LIGHT GREEN 220V AC – 1 SetPROTECTION MCB 6 A SP – 3 NosC.T. 250/5 A – 3 Nos |
| 45 | DANGER PLATE – 1BUS BAR CHAMBER 500 A for 3 phase and 250 A for neutral – 4ENCLOSURE OF SUITABLE SIZE – 1Panel Manufacturer RequirementsThe panel manufacturer should have following Govt. Approved Certificates:1. CPRI Certification Degree of Protection IP-65/662. CPRI Short Circuit withstand strength should be 50KA rms for 1.0 Sec with initial peak of 105KA3. CPRI Certification Rated current for short circuit not less than 4000 A with rated insulation voltage 660V4. ISO 9001 CERTIFIED |
| 46 | Supply, installing, testing and commissioning factory made and tested LT Panel Outdoor type, platform mounted, suitable for 415 Volts Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-65/66) and made of 3.15 mm thick CRCA SHEET & suitable channel mounted MC 70 mm Aluminium, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. The scope of work also comprising of the following:- Make:- Havells/Schneider/ABB/L&T/Universal Switch Gear Control/Finolex. (For AOC HOUSE)INCOMING MCCB 160 A 25 KA 4 POLE THERMAL MAGNETIC – 1 SetOUTGOING MCB 100 A 4 pole 16 KA – 2 NosDIGITAL VOLT METER (0-500V) – 1 SetDIGITAL AMP METER (0-60A) – 1 SetVOLT METER SELECTOR SWITCH – 1 SetAMP METER SELECTOR SWITCH – 1 SetINDICATING LIGHT RED 220V AC – 1 SetINDICATING LIGHT YELLOW 220V AC – 1 SetINDICATING LIGHT GREEN 220V AC – 1 SetOUTGOING TERMINAL – 6PROTECTION MCB 6 A SP – 3C.T. 60/5 A – 3 |
| 47 | DANGER PLATE – 1BUS BAR 250 A 4 STRIPS ALUMINIUM – 4ENCLOSURE OF SUITABLE SIZE – 1 UNIVERSALThe panel manufacturer should have following Govt. Approved Certificates:1. CPRI Certification Degree of Protection IP-65/662. CPRI Short Circuit withstand strength should be 50KA rms for 1.0 Sec with initial peak of 105KA3. CPRI Certification Rated current for short circuit not less than 4000 A with rated insulation voltage 660V4. ISO 9001 CERTIFIED |
| 48 | Supply, installing, testing and commissioning factory made and tested LT Bus Bar Chamber Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-55/66) and made of 3.15 mm thick CRCA SHEET & suitable channel mounted MC 70mm Aluminium, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. The scope of work also comprising of the following:- Make:- Havells/Schneider/ABB/L&T/Universal Switch Gear Control/Finolex. (For 8 OMQs)INCOMING MCCB 160 A 25 KA 4 POLE THERMAL MAGNETIC – 1 SetOUTGOING MCCB 100 A 16 KA 4P – 3 NosTimer switch complete with contactor, timer, MCB etc – 01 SetDIGITAL VOLT METER (0-500V) – 1 SetDIGITAL AMP METER (0-200A) – 1 SetVOLT METER SELECTOR SWITCH – 1 SetAMP METER SELECTOR SWITCH – 1 SetINDICATING LIGHT RED 220V AC – 1 SetINDICATING LIGHT YELLOW 220V AC – 1 SetINDICATING LIGHT GREEN 220V AC – 1 SetOUTGOING TERMINAL – 24PROTECTION MCB 6 A SP – 3 HPLC.T. 200/5 A – 3 |
| 49 | DANGER PLATE – 1BUS BAR CHAMBER 250 A 4 STRIPS ALUMINIUM – 4ENCLOSURE OF SUITABLE SIZE – 1 UNIVERSALThe panel manufacturer should have following Govt. Approved Certificates:1. CPRI Certification Degree of Protection IP-65/662. CPRI Short Circuit withstand strenght should be 50KArms for 1.0 Sec with intial peak of 105KA3. CPRI Certification Rated current for short circuit not less than 4000 A with rated insulation voltage 660V4. ISO 9001 CERTIFIED |
| 50 | Supply only 1.5 sqmm twin core PVC insulated and sheathed copper conductor multistrand cable for electric connection from overhead line / junction box to street light complete all as specified. |
| 51 | S&F as in repairs Junction box (Bus bar chamber box) of size 250 × 200 × 105 mm made out FRP suitable for 415 Volt, 4 Way TPN aluminium bus bars of capacity 100 amps with 01 No. MCB, SP, 6 Amp, 240 volts, 10 KA for controlling the street light complete fixing arrangement to the pole with nut, bolts and washers including providing the electrical connection for incoming / outgoing cable through proper lugs/thimbles complete all as directed. |
| 52 | M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as directed. |
| 53 | Supply, installation, testing & commissioning of 11 KV Outdoor type RMU, extensible type, floor mounted, consisting of 1 LBS + 2 VCB with internal copper bus bars, consisting of combinations of 630 Amp, 350MVA fixed manual Load Break Switch & fixed type Vacuum Circuit Breaker. All live parts, bus bars, LBS connections of RMU shall be enclosed in one tank to avoid multiple interconnections & sealed for life as per standard design of OEM non magnetic and non ferrite grade stainless steel tank having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year as tested as per IEC 62271-200. The unit shall have front cable entry for ease of installation. RMU shall be complete with all accessories such as Terminal boots, VPIS, cable supports, all front cable terminations, mechanical indications for Load break switch ON/OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60994. Altitude of installation up to 1000m as per IEC 60120. Extensible Bushings, if applicable shall be bolted type/side mounted outside the tank for connection of external bus bar. Also, the outer enclosure shall cover the full length of the switchgear, to ensure IP3X+IP54 protection for cable boxes. The unit shall be internal arc proof not less than 21KA for 1 sec for tank and Cable Box, and tested and totally safe for human beings. The gas release & personnel safety with internal arc proof shall not depend on plinth design. Bidder shall provide type test report to prove compliance to the “Internal fault IAC-AFLR as per IEC 62271-200. Internal arc proof & testing shall be done as per OEM norms. |
| 54 | The Vacuum Bottle shall be of same make as that of RMU to ensure better life cycle optimization for the RMU. Approved Make : ABB, Siemens, Schneider.630A Load Break Switch module for making of fault current alongwith Earth Switch of full making capacityShort time withstand current - 21KA/3 secMaking Capacity - 52.5kApAuxiliary contacts - 1NO + 1NCPower frequency withstand voltage - 28kVImpulse withstand voltage - 75kVNominal operating gas pressure - 1.2 to 1.4 Bar abs.Front cover mechanism - IP2XCable covers - 3XSnap action mechanism for manual operationCable box for front termination of the cable suitable upto 3 core 300 Sqmm, 11 KV XLPE cableRight angle non-touch proof Termination boots - 1 Set (R,Y,B) |
| 55 | 630A VCB module for making & breaking of fault current alongwith Earth Switch of full making capacityManual operated 630 A Vacuum circuit breaker having spring stored mechanism.Three position disconnector/earthing switch downstream vacuum circuit-breaker.Three position single spring mechanism for disconnector/earthing switch.“Live Cable” LED Indicators thru Capacitor Voltage Dividers mounted on the bushings.Short time breaking current - 21KA/3 secMaking Capacity - 52.5 kApAuxiliary contacts - 1NO + 1NCPower frequency withstand voltage - 28KVImpulse withstand voltage - minimum 75KVNominal operating gas pressure - 1.2 to 1.4 Bar abs.Front cover mechanism - IP2XCable covers - 3XGreen(ON)/Red(OFF) push buttons to operate VCB.30/C + 1E/F self powered numerical protection relay with Low and High set for Over current and Earth Fault.Resin cast ring core protection CT plate mounted with case: 10/1 A, 5P10, 2.5 VA - 3 NosMechanical ON/OFF/EARTH/Spring charge Indication of 1 VCB + 2 Load break switch.Cable boxes shall be Arc Proof interlocked with respective Earthing Switches.Right angle non-touch proof Termination boots - 1 Set (R,Y,B). |
| 56 | M&L for platform with Brick work of 2m x 2m x 1.5m incl excavation, PCC, Plaster, painting with weather proof paint and flooring of 150mm thick RCC type B-1 (20mm aggregate) and platform should be fenced with MS frame work with Angle and expended metal wire mesh of weight exc 4 Kg/Sqm, painting complete all as specified and directed by Engr-in-Charge. |
| 57 | \\"ARBORICULTURE WORK\\" |
| 58 | Supplying on site garden soil (sweet soil passed through 20 mm sieve and 90% to pass through IS sieve of 10 mm size free from all rubbish like lumps, stones, roots and other foreign materials suitable for gardening. The soil should be fresh from quarry. The colour of the soil generally be red including cost of all materials, labour, transportation, all tools, plants, taxes, octroi etc. complete as specified, directed and approved by GE (Stack/lorry measurements will be taken and 20% deduction shall be made towards voids). |
| 59 | Supplying on site manure, well decayed, well dried, well powdered without clods and free from stones, dried grass and other rubbish material. The colour of manure shall be black. The manure screened through sieve at designation 4.75 micron including carriage at site. The manure will be measured by measuring box. |
| 60 | Supplying on site recently produced Neem oil in form of cake stacked and used within 15 days from procurement @ 1 Kg per Sqm of soil to be mixed only for the top 300 mm deep soil. To prevent white ant attack to the roots of the plants. |
| 61 | M&L Planting large feature Trees: -In 0.6 M x 0.6 M x 0.6 M Pit, applying 10 gm DAP fertilizer in root zone in each pit, filling the pit with fresh garden soil/silt, sand and manure in ratio of 3:1 by volume (3 part of stacked volume of earth after reducing by 20% for voids, 1 part of stacked volume of manure after reducing by 8% for voids) mixing soil/silt, sand & manure thoroughly well as directed, watering with applying chemical insecticide phorate or equivalent as per manufacturer's instructions, applying fertilizer NPK8 mixing as per instruction of manufacturer, planting 1 to 2 yr healthy and 4 to 5 Feet (4'-5') tall specific feature trees sapling as per specification 8/10 M centre to centre along internal road and boundary maintaining till well established by watering, weeding, stirring of soil replacing of casualties etc complete. The contractor will responsible & take all suitable measures to protect the planted saplings from cattle, soil spray and high wind pressure & snowballs.Note:- A1. Excavation of pit shall be measured and paid under Sch A Part-II2. Removing of surplus soil of pit shall be measured and paid separately under Sch A Part-II3. Supply of garden soil and manure shall be measured and paid separately under Sch A Part-II4. Chemical insecticide phorate for termite control shall be paid in item No 3.58.5. NPK fertilizer and DAP fertilizer for root zone shall be paid separately in item No 3.59 & 3.60 respectively. |
| 62 | Gulmohar |
| 63 | Amaltas (Cassia Fistula) |
| 64 | Silver Oak |
| 65 | Indian Coral Tree (Erythrina Variegata) |
| 66 | Champa (Plumeria) |
| 67 | Palash (Butea Monosperma) |
| 68 | Hyophorbe Lagenicauli (a variety of Bottle Palm) |
| 69 | Planting shrubs/hedges :-Preparing the pits/strips upto depth of 0.3 mtr including applying the DAP fertilizer in root zone @ 25gm/Sqm, filling the pit with a mixture of manure and sweet earth at the ratio of 1:3 (one manure three sweet earth) and supplying and planting Shrubs/hedges of good approved quality (as per site given) healthy grown up saplings with good roots system, plant shall be of minimum 0.30 to 0.60 mtr tall from ground level at the time of planting, daily watering, deweeding, adding required fertilizers, replacing the died plants, spraying of pesticides all complete incl cost of all materials, labour, tools, plants, fertilizers without any extra cost etc all as specified, directed and approved by GE. The contractor will responsible & take all suitable measures to protect the planted saplings from cattle, salt spray and highwind pressure & snowballs.Notes :-(a) Excavation of pit shall be measured and paid under Sch A Part-II..(b) Removing of surplus soil of pit shall be measured and paid separately under Sch A Part-II.(c) Supply of garden soil and manure and shall be measured and paid separately under Sch A Part-II. |
| 70 | Large shrubs Golden Duranta, Hibiscus lafrance, Ixora Dwarf red, Techoma Capancia etc with 10 plants in one sqm as islands in green areas. |
| 71 | Small shrubs as ground cover in service corridors, sewer line etc @ 150 mm c/c |
| 72 | hedges along internal lawns/green areas |
| 73 | Climbers/creepers along periphery boundary wall 100mm c/c. |
| 74 | S&F MS tree guard of 60 cm dia and 1.75 mtr height made up of 20mm x 20mmx3mm MS angle with 1.5 mtr high GI netting with 0.71 mm galvanized steel wire including two years maintenance replacing the damaged tree guards & foing in PCC block of 1:2:4 to hold tight and handing over in good condition as per drawing. |
| 75 | Preparation of ground for planting of Pusa selection No-1 grass and filling fresh garden soilsit sand and manure. Mixing the garden soil, manure non edible soil thoroughly well leveling, watering on previous night and planting of Pusa selection No-1 grass as follows :- Cut the strips of 10-15 cms Make the furrows on the filled surface. Take the fine manure without any mbture and apply in these furrows. Put the cut ribbons of the grass strips. Press thoroughly water heavily for 3-4 days. Allow to lite dry and then apply roller 100-150 KT abovet Water regularly. The planting ratio shall be 15sqm matt of grass shall be spreaded in to 10 sqm on land over 100-150 KT above. Water regularly. The planting ratio shall be 15sqm matt of grass shall be spreaded in to 10 sqm on land over 100-150 KT above. Water regularly. The planting ratio shall be 15sqm matt of grass shall be spreaded in to 10 sqm on land over 100-150 KT above. Water regularly. The contractor will responsible & take all suitable measures to protect the planted sapings from cattle, salt spray and highwind pressure & snowballs.Note: -(a) Excavation shall measured & paid under Sch A Part-II.(b) Garden soil manure shall be paid under Sch A Part-II. |
| 76 | Supply of chemical insecticide phorate or equivalent for termite control. |
| 77 | Supply of NPK fertilizer for mixing in soil all as specified. |
| 78 | Supply of DAP fertilizer for root zone for plants/trees/ grass. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysNov 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender