Tender For Repair/Replacement Of Solar Water Heaters, Electric Geyser, Fitting And Other Connected Item Under Ge Babina Cantt
Tender Value
25 Lakhs
Estimated cost
Bid Submission
27 Oct 2026
19 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jhansi → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Replacement Of Solar Water Heaters, Electric Geyser, Fitting And Other Connected Item Under Ge Babina Cantt
BOQ
| Sl. No. | Item Description |
| 1 | Taking down, dismantling / unscrewing electric water heater (Geyser) for repair / servicing and refixing after repair reconnecting of electrical and water supply and testing with water pressure complete as specified and as directed.Note : If required to deposit unserviceable water heater to AGE (E/M) yard and collection serviceable against replacement from AGE (E/M) yard is responsibility of contractor) |
| 2 | S & F in replacement heating element 2 KW , Triangle type of any type copper sheathed and nickel plated of suitable size for water heater complete all as specified and as directed Make :- Bajaj / Airex/ / Elcon or other ISI Marked |
| 3 | S & F in replacement heating element 1.5 KW, Triangle type of any type copper sheathed and nickel plated of suitable size for water heater complete all as specified and as directed Make :- Bajaj / Airex/ / Elecon Agency or other ISI Marked |
| 4 | S & F in replacement heating element 2 KW, cup type of any type copper sheathed and nickel plated of suitable size for water heater complete all as specified and as directed Make :- Bajaj / Airex/ / Elcon or other ISI Marked |
| 5 | S & F in replacement heating element 1.5 KW, cup type of any type copper sheathed and nickel plated of suitable size for water heater complete all as specified and as directed Make :- Bajaj / Airex/ / Elcon or other ISI Marked |
| 6 | S & F in replacement heating element 2 KW ,Square type of any type copper sheathed and nickel plated of suitable size for water heater complete all as specified and as directed Make :- Bajaj / Airex/ / Elcon or other ISI Marked |
| 7 | S & F in replacement heating element 1.5 KW, square type of any type copper sheathed and nickel plated of suitable size for water heater complete all as specified and as directed Make :- Bajaj / Airex/ / Elcon Or other ISI Marked |
| 8 | S&F in replacement heating element 2 KW watt,Porcelain type for DITZ/VENUS type water heater complete all as specified and as directed. Make :- Bajaj / Airex/ / Elcon or other ISI Marked |
| 9 | S & F in replacement heating element for Solar water heater 2 KW, (size as per site requirement) ISI marked of any type copper sheathed and nickel plated of suitable size complete all as specified and as directed Make :- Bajaj / Airex/ / Elcon or other ISI Marked |
| 10 | S & F in replacement heating element for Solar water heater 3 KW, (size as per site requirement) ISI marked of any type copper sheathed and nickel plated of suitable size complete all as specified and as directed Make :- Bajaj / Airex/ / Elcon or other ISI Marked |
| 11 | S & F in replacement fusible plug having melting point 90 degreeC to 100 degree (as per sample) complete all as specified and as directed. |
| 12 | S & F in replacement safety valve dead weight type for 25 Ltr gyeser (As per sample) complete all as specified and as directed. |
| 13 | S & F in replacement safety valve dead weight type for 50 Ltr Gyser(As per sample) complete all as specified and as directed. |
| 14 | S&F in replacement glass wool for geyser complete all as specified and as directed. |
| 15 | S & F base plate complete with rubber packing suitable for water heater (geyser) for 25 litre capacity any make complete all as specified and as directed. |
| 16 | S & F in replacement base plate complete with rubber packing suitable for water heater (geyser) for 50 Ltr any make capacity complete all as specified and as directed |
| 17 | S&F in replacement outer cover of geyser suitable for 25 Ltr capacity of geyser, complete all as directed |
| 18 | S&F in replacement outer cover of geyser suitable for 50 Ltr capacity of geyser, complete all as directed |
| 19 | S & F in replacement thermostate switch suitable for 25 Ltr water heater (Geyser) of size 11\\"/11\\"/280 mm any make ranging from 5 degree centigrade to 75 degree centigrade including making electric connection complete all as specified and as directed.Make :- Bajaj / Airex/ / Elcon or other ISI Marked |
| 20 | S & F in replacement thermostate switch suitable for 25 Ltr water heater(Geyser) of size 7\\"/7\\"/175 mm any make ranging from 5 degree centigrade to 75 degree centigrade including making electric connection complete all as specified and as directed.Make :- Bajaj / Airex/ / Elcon or other ISI Marked |
| 21 | S & F in replacement thermostate switch suitable for 25 Ltr water heater(Geyser) 4 terminals 16 KA 250 Volts AC Capillary thermal Switch thermosate any make ranging from including making electric connection complete all as specified and as directed.Make :- Bajaj / Airex/ / Elcon or other ISI Marked |
| 22 | S & F in replacement thermostate suitable for 50 Ltr water heater(Geyser) of any make ranging from 5 degree centigrade to 75 degree centigrade including making electric connection complete all as specified and as directed.Make :- Bajaj / Airex/ / Elcon or other ISI Marked |
| 23 | S&F storage type water heater (Geyser), 230 Volt AC, 50 Ltrs capacity with minimum 5-star rating comprising inner tank, suitable heatng element, thermostate with adjustable temperature stting 0-90 C, indication lamps provision ofr inlet outlet and air vent connections & NRV, PVC connection 15 mm size, heavy duty with brass nuts, 450 mm long mounteted on wall surfaces including all fixing arrangement such s faster bolts, nuts washers etc complete including making good disturbed wall surfaces matching with the existing surfaces and finishing all as specified and as directed by Engr-in-charge Make - Havells /Bajaj/Orient/CG as approved by GE. |
| 24 | All as per srl item No. 23 here-in-before but water heater (Geyser), 230 Volt AC, 5 Ltrs capacity complete all as specified and directed. |
| 25 | All as per srl item No. 23 here-in-before but water heater (Geyser), 230 Volt AC, 7/10 Ltrs capacitycomplete all as specified and directed. |
| 26 | S & F in replacement Geyser Assembly for 25 Ltr capacity geyser Triangle type / Square type ( As per sample ) with rubber packing ( As per Sample ) complete all as specified and as directed. Make: Airex/ / Elcon or other ISI Marked. |
| 27 | S & F in replacement Geyser Assembly for 50 Ltr capacity geyser Triangle type / Square type ( As per sample ) with rubber washer complete all as specified and as directed. Make: Airex/ / Elcon or other ISI Marked |
| 28 | S & F in replacement geyser inner tank stainless steel of 25 litre capacity complete all as specified and as directed |
| 29 | S & F in replacement geyser inner tank stainless steel of 50 litre capacity complete all as specified and as directed |
| 30 | S & F in replacement PVC connection pipe 15mm dia of 450mm long with check nuts on both end with rubber washer complete all as specified and as directed. |
| 31 | S & F in replacement PVC insulated flexible cable 3 core with standed copper conductor of size 2.5 Sqmm against unserviceable flexible cable complete all as specified and as directed. |
| 32 | S & F in replacement PVC insulated flexible cable 3 core with standed copper conductor of size 4.00 Sqmm against unserviceable flexible cable complete all as specified and as directed. |
| 33 | S & F in replacement plug top 3 pin 15 Amps ISI Marked as specified and as directed. |
| 34 | S& F in replacement Non Return Valve 15 mm bore cast copper alloy screwed for iron pipe or brass ferrule complete all as specified and as directed. |
| 35 | S& F in replacement 15mm bore GI tubing, medium grade fixed on walls/floor/ceiling with and including necessary GI fittings such as sockets, bends, elbows, tees, short pieces etc including taking down existing GI tubing including making good disturbed surface complete all as specified and directed. |
| 36 | S& F in replacement 20 mm bore GI tubing, medium grade fixed on walls/floor/ceiling with and including necessary GI fittings such as sockets, bends, elbows, tees, short pieces etc including taking down existing GI tubing including making good disturbed surface complete all as specified and directed. |
| 37 | S & F in replacement stop valves chromium plated cast copper alloy, screwed down high pressure with crutch or butter fly handle external threaded screwed bothends for iron pipes of 15 mm dia complete all as specified as directed. |
| 38 | S & F in replacement bib taps chromium plated screwed down high pressure with crutch or butterfly handle external threaded screwed for iron pipes 15 mm dia complete all as specified. |
| 39 | S & F in replacement neon lamp indicator red / green rectangular / round type, complete all as specified and as directed. |
| 40 | Supply & fixing GI nut bolts any type any size as per site requerment all as directed |
| 41 | M & L insulation for hot water worn out insulation 15mm dia GI pipe, medium grade for solar water heater system complete all as specified and as directed. |
| 42 | M & L for brazing rod of copper / steel inner tanks of 25 ltr capacity of geyser and testing complete all as specified and as directed. |
| 43 | M & L for brazing rod of copper/ steel inner tanks of 50 ltr capacity of geyser and testing complete all as specified and as directed. |
| 44 | S & F Modular PVC metal enclosure with two pin socket , chain plug cover with one MCB SP of 20 Amp capacity with alignment 10 KA ‘C’ series complete all as specified and as directed. |
| 45 | Suppling and fixing Gun metal gate valve 15 mm bore with all GI fitting as per existing all as specified and directed |
| 46 | Suppling and fixing in replacement of Gun metal gate valve 20 mm bore with all GI fitting as per existing all as specified and directed |
| 47 | Supply and fixing in replacement of solar plate collector as per existing complete with rubber packing with solar panel glass (As per sample ) complete all as directed. Note :- The rates shall be deemed to be included for all materials or manpower required which are otherwise not specifed in the discription but are requred to ensure proper installation commissioning and operation of soler water heater system as directed at site |
| 48 | Supply and fixing in replacement of solar water tank collector as per existing complete with rubber packing with complete accessory ( As per sample ) complete all as directed. Note :- The rates shall be deemed to be included for all materials or manpower required which are otherwise not specifed in the discription but are requred to ensure proper installation commissioning and operation of soler water heater system as directed at site |
| 49 | Supply and fixing in replacement of 500 ltr capacity of rotational moulded polyethylene water storage tank, 3 (three) layered construction ISI marked BLACK cylindrical vertical with closed top, hoisting and fixing in position including 20mm bore GI pipe medium grade wash out pipe 450 mm long with and 20mm dia GI pipe medium grade over flow pipe 600mm long with fitting including dismantling of existing water tanks of any type and capacity exceeding 500 ltr complete all as directed. |
| 50 | S&F in replacement of sub main wiring with PVC insulated, unsheathed 2 single core cable 1100 volts grade with copper conductor of size 4 sq mm (Nominal area) multi stranded drawn into conduit (Existing / new) with and including 6 sqmm green stranded copper conductor as contineous earthwire with lugs complete all as specified and as directed. Note: New conduit and conduit accossories shall be measured separately. |
| 51 | S & F in replacement of Regid non-metallic PVC conduit not less than 20 mm dia (external) ISI marked (on surface) incl of all accessories and all fittings such as Tees,bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers,lock nuts, saddles, pipe hook etc complete all as specified and as directed |
| 52 | S & F in replacement of MCB protected plug socket power units 20A /25A SP with MCB 20A/25 A SP ‘C’ series fixed in concealed or surface complete all as specified and as directed by Engineer in Charge.Make Havells/Indoasian/ABB/ Legrand/Benlo |
| 53 | M&L for submain wiring with PVC insulated, unsheathed 2 single core cable 1100 vols grade FRLS with stranded copper conductors of size 2.5 sq mm (Nominal area) drawn into conduit (Existing / new), with and including 2.5 sq mm green PVC insulated FRLS stranded copper conductor cable as contineous earth wire terminated with copper lugs / thimbles all as specified and as directed. Note : 1. New conduit and conduit accessories shall be measured and paid separately. |
| 54 | S&F in replacement storage type water heater (Geyser), 230 Volt AC, 25 Ltrs capacity 2000 W with minimum 5-star rating comprising inner tank, suitable heatng element, thermostate with adjustable temperature stting 0-90 C, indication lamps provision ofr inlet outlet and air vent connections & NRV, PVC connection 15 mm size, heavy duty with brass nuts, 450 mm long mounteted on wall surfaces including all fixing arrangement such s faster bolts, nuts washers etc complete including making good disturbed wall surfaces matching with the existing surfaces and finishing all as specified and as directed by Engr-in-charge Make - Havells /Bajaj/Orient/CG. |
| 55 | S&F in replacement of 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape & overall PVC sheathed in service connection suspended by insulating hanger not more than 1 meter apart including 4 mm GI suspension wire one twin core cable flat or circular of size 10 Sq mm to be connected to existing MCB box / Main switches complete all as specified as dircted. |
| 56 | S&F 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape & overall PVC sheathed in service connection suspended by insulating hanger not more than 1 meter apart including 4 mm GI suspension wire one twin core cable flat or circular of size 6 Sq mm to be connected to existing MCB box / Main switches complete all as specified as dircted. |
| 57 | S&F MCB DB, sheet metal enclosures double door SPN 8 way with bus bar 240 volts 2 in 1 shutter type (METAL DOOR) type with blanking plates where required and IP 43 degree protection complete all as specified and directed. |
| 58 | S&F, MCB SPN 40-63 Amps, 240 volts 'C' series 10 KA ,including connection with suitable size copper lugs complete all as specified and directed. |
| 59 | S&F, MCB SP 240 volts, 6 to 40 Amps, 'C' series 10 KA including connection with suitable size copper lugs. complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysNov 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender