Project Description

Tender for Setting Up Of Hydraulic & Boat Repair Facility Engineering Division At Nd (V).

BOQ

Name of Work:- SETTING UP OF HYDRAULIC & BOAT REPAIR FACILITY ENGINEERING DIVISION AT ND (V).
Sl. No. Item Description
1Lump sum amount worked out by the contractor for \\"BUILDINGS & STRUCTURES\\" as listed in Schedule 'A' Part-I.
2Lump sum amount worked out by the contractor for \\"PILE FOUNDATION\\" as listed in Schedule 'A' Part-II.
3Lump sum amount worked out by the contractor for \\"SUSPENDED FLOOR\\" as listed in Schedule 'A' Part-III
4Lump sum amount worked out by the contractor for \\"DEMOLITION/DISMANTLING\\" as listed in Schedule 'A' Part-IV.
5Lump sum amount worked out by the contractor for \\"SITE CLEARANCE/ AREA DEVELOPMENT/ EARTH WORK\\" as listed in Schedule 'A' Part-V
6Lump sum amount worked out by the contractor for \\"CIVIL REPAIR WORKS/ ADDITION/ ALTERATION\\" as listed in Schedule 'A' Part-VI
7Lump sum amount worked out by the contractor for \\"SEWAGE DISPOSAL\\" as listed in Schedule 'A' Part-VII.
8Lump sum amount worked out by the contractor for \\"PATH, HARD STANDING\\" as listed in Schedule 'A' Part-VIII
9Lump sum amount worked out by the contractor for \\"INTERNAL WATER SUPPLY\\" as listed in Schedule 'A' Part-IX.
10Lump sum amount worked out by the contractor for \\"INTERNAL ELECTRIFICATION\\" as listed in Schedule 'A' Part-X
11Lump sum amount worked out by the contractor for \\"EXTERNAL WATER SUPPLY\\" as listed in Schedule 'A' Part-XI
12Lump sum amount worked out by the contractor for \\"EXTERNAL ELECTRIFICATION\\" as listed in Schedule 'A' Part-XII
13Lump sum amount worked out by the contractor for \\"AIR CONDITIONING & REFRIGERATION\\" as listed in Schedule 'A' Part-XIII.
14Lump sum amount worked out by the contractor for \\"FIRE ALARM AND DETECTION SYSTEM\\" as listed in Schedule 'A' Part-XIV
15Lump sum amount worked out by the contractor for \\"EXTERNAL FIRE FIGHTING SYSTEM\\" as listed in Schedule 'A' Part-XV
16Lump sum amount worked out by the contractor for \\"LIGHTNING PROTECTION\\" as listed in Schedule 'A' Part-XVI
17Schedule \\"A\\" Part - XVII: [Miscellaneous Items] [To be quoted by the bidder.]
18PILE FOUNDATION
19M&L for drilling or boring for 500 mm nominal dia bored cast-in-situ piles through any or all types of strata i.e. soft/loose soil, stiff clay, gravel, cobble stone, compact moorum, soft conglomerate or loose boulders, disintegrated rock, weathered rocks/rocks etc., (except hard rock for socketing depth) upto top of socketing depth/founding depth by adopting suitable method with perennial water and disposal of drilling/bored materials outside MD land at GVMC designated places exc 10km and not exc. 15km, as directed, complete all as specified and as directed by Engineer-in-Charge.
20All as per Serial Item No. 17.002 here in before but through hard rock for founding minimum 3D (Where D is dia of pile) metre depth for 500 MM dia pile for Item Nos. 17.02 & 17.03:-(i) The depth of boring for piles shall be measured from existing ground level/bed level/ river bed level to the approved founding level. (ii) It shall be ensured that the waste bentonite slurry/ drilled or bored material is pumped off from the premises outside MD land at GVMC designated places exc 10km and not exc. 15km to locations shown by GE to contractor at his own cost. (iii) All channels/tanks made for bentonite circulations shall be filled with approved moorum obtained by contractor at his cost after clearing all bentonite cakes.(iv) The contractor may use any approved method as approved by GE for boring without any extra cost to the Govt. The rates for boring of piles shall be inclusive of any method/ casing that may be used by the contractor for bored piles. Nothing extra shall be paid. (v) For the purpose of payment of boring/drilling, description of hard rock shall be as given in SSR Part-I specification. (vi) The rate quoted by the contractor shall be inclusive of the rates for the shifting and setting up of piling rig as many times as required.
21Carrying out initial load tests on test pile of 500mm dia as per standard procedure laid down in IS-2911 by static load test method with compressive strength, including construction of test cap, dismantling the cap after the test and clearing the site and maintaining complete records of load settlements etc. as specified and as directed by GE and submission of reports for a test load of 175 tonne in non-working areas in the vicinity of site, including the cost of new piles with specification as same as working pile with minimum depth of socketing into the hard rock 3D (Where D is dia of pile) depth, complete all as specified and as directed by Engineer-in-Charge. Note: Load required for testing as per IS shall be arranged by the contractor and test pile shall be abandoned after testing.
22Carrying out routine load test on 500 mm dia pile (working pile) as per standard procedure given in IS-2911 (Part IV) by static load test method with compressive strength, including construction of test cap, dismantling the cap after the test and clearing the site and maintaining complete records of load settlements etc. and submission of reports for a test load of 105 tonne, complete all as specified and as directed by Engineer-in-Charge.Note: Load required for testing as per IS shall be arranged by the contractor and pile for testing shall be shall be selected by GE.
23Chipping of laitance concrete in piles above cut off level up to a maximum of 1m from cut of level using suitable tools and equipments and dressing the pile head suitably so as to receive the form work for deck work, including breaking to the required level exposing the pile reinforcement to sufficient length as per approved drawing for embedding into the base slab etc., and disposal the debris to distance of exc. 10.0Km but n. exc. 15.00Km, complete all as specified and directed by the Engineer-in-Charge.
24CIVIL REPAIR WORKS/ ADDITION/ ALTERATION
25M&L for polymer composit non skid flooring of thickness not less than 10mm, in floors etc over 15mm thick screed bed with cement mortar 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer vin Charge.
26Providing & fixing false ceiling with fully perforated 12mm thick micro tegular edged or 10mm thick sqare edged GRG false ceiling tiles at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of size 595 X 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRCO .50 to 0.75 as per IS 8225: 1987, Noncombustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum0 to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33 mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15 X 32 mm of length 3000 mm, cross-T of size 15 X 32 mm of length 600 mm to form grid module of size 600 X 600 mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8 mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L- shape level adjuster of size 85X25X2mm. Galvanized iron perimeter wall angle of size 24X24X0.40mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.
27Supply and application of 3mm thick static dissipative grade ESD flooring, PIDILITE or equivalent, after proper surface preparation, that includes obtaining clean, dry, and sound concrete, the surface must be prepared using vacuum assisted grinding to remove all laitance, the residual moistuer should not be more than 4-5%, followed by application of epoxy primer-cipoxy18, PIDILTE or equivalent using a roller and allowing it to dry for 8 hours, followed by applying 2 mm thick epoxy screed using Cipoxy18 PIDILTE or equivalent mixed with graded aggregate, establishing ground couple over the primer layer. Followed by fixation of self-adhesive copper Strip/Copper tape to fixed at every 3 mt in a crises manner (The self-adhesive copper tape shall struck at the peripheries of the floor and joined to the ground/Earthing pit) and application of conductive middle coat of two component aquox ESD or equivalent using a brush or a roller and allowing to cure for 12 hours, followed by application of Statguard FF108 any equivalent of selected RAL shade on the floor and spread to a uniform thickness of 1 mm with a notched trowel and deaerate with spiked roller. Allow the film to cure for 24 hours. NOTE: - Resistance level; surface resistivity range :10^6 to 10^9; ESD topcoat should be carbon fibre free and have third generation carbon nano tube technology for better & uniform resistance.
28M&L for 50 mm thick vaccum dewatered concrete flooring using M-20 grade design mix concrete by vaccum processing with use of suction mat and vaccum pump and trowelling the surface with skim floater including sprinkling floor hardner @ 5 kg/sqm over concrete surface while it is greenand the surface finished mechanically even and smooth complete all as specified and directed by Engr-in-Charge.
29INTERNAL ELECTRIFICATION
30M & L for point wiring with 1.5 Sq.mm. (nominal cross sectional area) PVC FRLS insulated unsheathed cable with copper conductor, single core multi stranded 1100 V grade confirming to IS 694: 1977 drawn in rigid PVC conduit concealed including provision of not less than 20mm bore rigid PVC conduit as per IS 9537 (Part 1-1983) with conduit accessories, provision of junction boxes, tees, terminal boxes with factory made of 1.6 mm thick MS boxes fitted, modular cover plate with frame for mounting modular switches/ sockets etc, including one run of 1.5 Sq.mm. single core PVC FRLS unsheathed cable with multi stranded copper conductor as earth continuity conductor and connected to common earth dolly for one light/bell/fan/exhaust fan/wall mounted fan/socket on indepedent board controlled by one way switch complete all as specified and as directed by the Engineer-in-Charge. Note: Cutting chases and making good surfaces shall be included in Schedule \\"A\\" Part-I.
31All as per item no. 19.01 here in before but 5 Amps socket point on same board complete all as specified and as directed by the Engineer-in-Charge.
32All as per item no. 19.01 here in before but 5 Amps socket point in independent board complete all as specified and as directed by the Engineer-in-Charge.
33All as per item no.19.02 here in before but bell point in independent board complete all as specified and as directed by the Engineer-in-Charge.
34All as per item no. 19.03 but 2.5 Sq mm copper cable FRLS and 2.5 Sqmm one single core copper earth wire for 5/15 Amp Switch Socket point complete all as specified and as directed by the Engineer-in-Charge.
35All as per item no. 19.04 here in before but 2way light point in independent board complete all as specified and as directed by the Engineer-in-Charge.
36S & F air circulators fans (wall mounted type )230V single phase industrial type 600mm sweep suitable for wall mounting complete all as specified and as directed by the Engineer-in-Charge.
37S & F pedestal type air circulators fans (wall mounted type )230V single phase oscillating type 500mm sweep suitable for wall mounting complete all as specified and as directed by the Engineer-in-Charge.
38S & F next generation, energy saving, environment friendly & robust highbay LED suspended light fitting with PDC housing suitable for ceiling (Surface/ suspended) mouing with system efficacy upto 150 lm/W of capacity 100W complete all as specified and as directed by the Engineer-in-Charge
39EXTREANAL WATER SUPPLY
40M&L for Valve chamber of size 600mm x 600mm x 600mm internal dimensions, with and including excavation in any type of soil, spreading, levelling and refilling etc. PCC (1:4:8) type D2 for foundation, Fly ash brick work of one brick thick wall in CM (1:4) including internal plaster 15mm thick in CM (1:4) external plaster 15mm thick(1:4) up to 150mm below GL and providing coping in PCC (1;2:4) type B1, angular iron frame of size 50x50x6mm with 3mm thick MS plate cover complete including locking arrangements and having FRP coating of 2mm thick on both inside and outside surfaces all as shown in TD drawing and complete all as specified and as directed by Engineer-in-Charge.
41S & F Pumping sets, centrifugal , electric driven, supply and install complete up to 5 WHP single phase operating on 170 to 280 Volts AC 50 Hz inclusive of starter and PCC foundation complete all as specified and directed by Engineer-in-Charge.
42Material and labour for Cutting the existing GI pipe line of 100 mm dia and inserting of 100 X 100 X 50mm dia new tees, branches etc of suitable size complete all as specified and as directed by Engineer-in-Charge.
43Material and labour \\" T joint\\" 100 X 100 X 50mm for branch pipe by making opening 100mm dia from existing water line complete all as specified and directed by Engineer-in-Charge.
44EXTREANAL ELECTRIFICATION
45Supply, install, testing and commissioning of 11KV compact sub station with 200KVA(ONAN) Type Transformer and LT panel. The 11KV outdoor package sub station shall be consisting of following:1. HT SWITCHGEAR11 KV, 630Amps, 21KA for 3 sec. SF6 insulated Non -Extinsible Compact switchgear(Type CV+M) consisting of one No motorized load breakswitch one no.Fixed Motorised vacuum circuit breaker(VCB) having inbuilt load break switch and earth switch within SF6 insulated robotically welded non ferrite non magnetic stainless steel enclosure of thickness 2.5 mm having IP 67, with series trip, self powered microprocessor based numerical 3 O/C & 1E/F relay (IDMTL+Inst) protection with metering module. Relay shall be self powered with RS485 communication port. Protection CT shall be 100/1a 2.5VA SP10. Standard Manometer (SF6 Gas Pressure Indicator), Voltage presence indicator (VPIS) for incoming Healthy indications, Manual push button for breaker ON/OFF Mechanical Indication for Breaker & LBS ON/OFF/EARTHED Operating handle.Metering CT shall be 100/1A 2.5VA Class 1.0 accurasy Metering PT :11000/ 3 110V/ 3 50 VA Class 1.0 Accuracy. DC battery 12Ah capacity & Charger Trafo Scheme 6 window Annunication +Hooter Master trip protection realy All incoming modules of the RMU shall be capable for cable termination of 3Cx120sq.mm AI XLPE Cable
462.TRANSFORMER200KVA, 11KV/433V Dyn 11 oil filled (ONAN) Hermetically sealed distribution transformer with corrugated radiator wall (without conservator type design) & top mounted normal porcelain bushing for HT, LT with OFF circuit tap changer. Off circuit Tap Links(OCTL),Tapping range+5% to -5% in a steps of 2.5% (4Steps/5 positions). Tempreture rise shall be 40/45 Deg.C for oil/winding resp. Over an ambient of 50 Deg.C Tempreture. Insulationclass:A, Transformer losses as per IS1180 Efficiency level 1/Star 1 as per latest Ammendment 4. Max.Total losses at 50% loading :1860 W @120 Deg.C Max.Total losses at 100% loading:5300W @120 Deg.C % Impedance (%Z) shall be 4.5% (Subject to IS Tol) Rating & Diagram (R&D)Plate Fitted on Transformer Oil Temp.indicator (OTI) with alaram and trip contact, winding Tempreture Indicator (WTI) with alarm and trip contacts (with RS-485 Port)
473. LT Panel BoardLT Panel cubical type floor indoor type mounted double door, 3 phase 4 wire 50 cycles, 415 volts with 630A Aluminiun Bus bar (100% for phase & Neutrals) Current density 1 amp/ sqmm, having IP 2X, Fabrication using 1.5/2mm CRCA sheet steel complete with internal wiring conssiting of following: -Incomer from transformer 400A, 433V 4P 50 Hz 36 KA Fixed Manual MCCB Microprocessor based released OC, EF, SC Protection- 01 NoOutgoing Feeders100A 433V 4P 50Hz 36 KA Fixed Mnaual MCCB Microprocessor based released OC, EF, SC Protection - 04 Nos63A 433V 4P 50 Hz 36 KA Fixed Manual MCCB Microprocessor based released OC, EF, SC Protection - 03 NosOn load Changeover switch 400 Amps-01Nos Outdoor EnclsoureOutdoor type enclosure having construction of Galvanised sheet steel having 1.5 mm thickness for Non-load bearing & 2 mm for Load bearing partition sheets & Door with HRCA 4 mm base frame The Enclosure shall have IP 54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for Transformer compartment. The enclosure exterior shall be powder coated (Colour Light gray and dark gray). Each compartment will be provided with the door and pad lo+E9:E11cking arrangment.
48The compartment illumination lamp with door operated switch shall be provided fro MV & LV compartment. Interconnection and earthing Interconnection between HT switchgear & Transformer using 1C x 3R x 95 Sqmm XLPE single core aluminium unarmored cable & interconnection between transformer & LT switchgear using aluminium busbars with aluminium flexible. Internal earthing connections by using 50 x 6mm GI strips and 50 x 6mm CU transformer neutral.
49S & F cable Junction Box IP 65 of size 200 X 160 X 98 mm with MCB SP 6 Amps complete incl necessary fixing arrangement complete all as specified and directed by Engr-in-Charge.
50S & F hot dip galvanized perforated type factory made cable tray of size 300 X 75 X 2 mm thick complete with coupling plate bends. MS brackets for support and clamps for fixing of cable on the try incl nut bolts washers and other fixing materials complete all as specified and directed by Engr-in-Charge.
51Cutting, disconnecting and rerouting of any size serviceable aluminium/copper conductor PVC insulated XLPE HT cable of any size upto 400 sqmm and making good disturbed surfaces complete as all as specified and as directed by Engineer-in-Charge.
52Cutting, disconnecting and rerouting of any size serviceable aluminium/copper conductor PVC insulated XLPE LT cable of any size upto 400 sqmm and making good disturbed surfaces complete as all as specified and as directed by Engineer-in-Charge.
53Cutting, disconnecting and rerouting of any size unserviceable GI/CI pipe upto 150 mm dia and making good disturbed surfaces complete as all as specified and as directed by Engineer-in-Charge.
54M&L for earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-I, including excavation / earth work in any strata, adequate quantity of charcoal and common salt, PCC chamber with RCC 1:2:4 type B1 40mm thick cover slab with 8mm dia TMT bars @150mm c/c in both ways, suitable handle and angle iron frame of suitable size to fix the cover, with 20mm bore GI pipe light grade for watering with funnel, wire mesh and 40mm bore GI pipe medium grade for protection of galvanised iron strip 32×6mm, including testing after completion and complete all as specified and as directed by Engineer-in-Charge.Note: Earth wire will be measured up to & including 7.5mtr from the earth strip or earth testing terminal block whichever is lesser under this item.
55AIR CONDITIONING
56S & F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 140V to 295V with output voltage stabilized at 230V with accuracy of +2.5% and of capacity 2KVA complete all as specified and directed by Engr-In-Charge.
57S & F Mineral RO Water Purifiers 8 liter storage capcaity, purification by RO+UF+UV+TDS control with purification and two filter candles in addition with each purifier complete all as specified and directed by Engr-In-Charge.Model No. ELEGANT LITE 8L RO+UF+TDS of KENT Make or equivalent in other approved makes given in the tender documents as approved by GE
58Supply, install, testing and commissioning of vertically constructed Dehumidifier 3 phase, 415 volts, 50 Hz, AC of capacity 350 Ltr/ day operated an 5-50°C ambient temperature with rotary typeair compressor with Air flow rate 2720 m3/hr and maintaining relative humidity 30-90% having micro computer based controller with panel made of 20 SWG sheet with all accessries and connections complete all as specifiied and as directed by Engr-in-Charge.
59S & F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of ±2.5% and of capacity 4KVA complete all as specified and directed by Engr-In-Charge.
60FIRE ALARM AND DETECTION SYSTEM
61Supply, installation, testing and commissioning of Microprocessor based intelligent adressable networking type fire alarm panel with 4 x 20 Alpha numeric LCD display, EN54 Standreds Event logging and printing facility, Real time clock & RS-485 port to connect repeater panel via 4 wires, Keyboard programming with password locking. Provision of RS-232 for LAN connection with 12 Hrs backup facilty UPS system for AFDC panel . Provision of connecting Fire Fighting equipments as required to complete all as specified and directed by Engr-in-Charge. Note:(i) One loop micro processor
62Supply, installation, testing and commissioning of Microprocessor based intelligent adressable type fire alram repeat panel EN54 Standrerds with 4 x 20 Alpha numeric LCD display,Keyboard programming with passowrd locking.Provision of connecting Fire Fighting repeat equipments as required to complete all as specified and directed by Engr-in-Charge.
63Supply, installation, testing and commissioning of intelligent analogue addressable multi criterion detectors combination of Heat and Smoke below false ceiling/ on ceiling including the cost of base plate. 75 mm dia MS outlet box for fixing of the detector base, mounting accessories etc., complete all as specified and directed by Engr-in-Charge.
64Supply, installation, testing and commissioning of intelligent addressable Manual Call point resettabel made of ABS/cas aluminium for indoors and outdoors with Fire indication and complete all as specified and directed by Engr-in-Charge.
65Supply, installation, testing and commissioning of addressable wall mounting, strobes cum hooters including the cost of mounting accessories complete as per specifications and as required including testing and commissioning and complete all as specified and directed by Engr-in-Charge.
66Supply and fix of 2 core 1.5 Sqmm copper screened cable and including stove enameled steel conduit not less than 25 mm dia, high conductivity annealed bare electrolytic copper conductor 650/1100V grade, PVC insulated pair twisted & screened, flexible both inner and outer FR/FRLS PVC sheathed with proper pair identification. 1.2 Standard : As per 1554, part-1 & IS 5831 latest and any other relevant standard; complete all as specified and as directed.
67S & F Sprinkler control panel with audio visual indications-relay logic type and complete all as specified and directed by Engr-in-Charge. (a) Water release module : Auto/Manual release mode(b) Auto with built in timer(settable) & emergency manual over ride switch NMAke: Honeywell/System Sensor/Spencers.
68EXTERNAL FIRE FIGHTING SYSTEM
69Supply, lay in trenches, ducts, jetty gallery, connect, test and commissioning Ductile iron pressure pipe with flanged and confirming to IS-8329 : 2000 in standard maximum lengths , class K-9, flange rating PN-10, including necessary gasket and special items/fittings pipes lining inside with cement mortar (CML) outside with bituminous coating as per Annx 'C' of IS-8329 of 150mm bore size complete all as specified and as directed by Engineer-in-Charge.Note:-(i) Necessary earth work and fittings will be measured and paid for separately.
70Supply, lay in trenches, ducts, jetty gallery, connect, test and commissioning Ductile iron pressure pipe with flanged and confirming to IS-8329 : 2000 in standard maximum lengths , class K-9, flange rating PN-10, including necessary gasket and special items/fittings pipes lining inside with cement mortar (CML) outside with bituminous coating as per Annx 'C' of IS-8329 of 80mm bore size complete all as specified and as directed by Engineer-in-Charge.Note:-(i) Necessary earth work and fittings will be measured and paid for separately.
71Re-routing of existing water supply and fire main system by disconnecting and taking out CI/MS pipe of size 150 mm /100 mm dia complete including fire hydrand/ fire valves/ from the existing position complete all as specified and as directed by Engr-in-Charge.
72M & L for fabrication and erection fire stand of suitable size made out of angle iron/channel and paint with 2 coats of post office red colour synthetic enamel paint over a coat of red oxide primer and lettering with white paint including Galvanised MS fire bucket 14 Ltr Cpacity -04 Nos and one bucket for sand and complete all as directed by Engr-In-Charge.
73S & F PVC water tank of capcity 10,000 liter (terrace tank) and complete all as directed by Engr-In-Charge.
74Supply install testing and commissioning monoblock pump set KDS1040, 3 phase, 415 volts 50 Hz AC of capacity 10/7.5 HP/KW of 36 mtr hed and discharge 900 Ltr/m with 80m suction and 65 mm discharge line complete all as specified and directed.
75Supply and fixing AFFF type fire extinguishers - mechanical foam type 9 litres capacity complete with initial charge, gun metal cap, discharge hose with nozzle, wall fixing brackets, etc., complete all as specified and as directed by Engineer-in-Charge.
76Supply and fix light weight screw grip type CO2 fire extinguishers – 4.5 Kg capacity complete with initial charge, gun metal cap, discharge hose with AB horn, nozzle, wall fixing brackets etc confirming to IS : 15683 with ISI mark complete all as specified and as directed by Engineer-in-Charge.
77Schedule of Credit (minus) Rs 33767.60Details of items for Schedule of credit is given Serial page No. . This Amount shall be automatically deducted to arrive at tendered sum. Please Enable Macros to View BoQ information
78Schedule of Credit (minus) Rs 33767.60Details of items for Schedule of credit is given Serial page No. . This Amount shall be automatically deducted to arrive at tendered sum. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57898273
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 5.78 Crore
LAST DATE 13-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Setting Up Of Hydraulic & Boat Repair Facility Engineering Division At Nd (V).
Basic Detail
Tender No DDG CE V TOKEN 10 OF 2025- 2026
Bidding Type Tender
Location
City Visakhapatanam
State Andhra Pradesh
Key Dates
Publish Date 06 Oct 2026
Submission Date 13 Nov 2026
Open Date 20 Nov 2026
Finance
Tender Value 5.78 Crore
Tender Fee 3000
EMD 6.14 Lakhs
Exemption Available
Document List
3470ArchDrgs.pdf
3470IP.pdf
3470Preprise.pdf
3470SPLD.pdf
3470StrctDrgs.pdf
3470Tender.pdf
3470TypDrgs.pdf
ada00023-e809-4bf3-935f-82aad8b078ef.html
BOQ_888810.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 31 days
Nov 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 38 days

Tender Documents

Download All (ZIP) ↓
pdf

3470ArchDrgs.pdf

pdf

3470IP.pdf

pdf

3470Preprise.pdf

pdf

3470SPLD.pdf

pdf

3470StrctDrgs.pdf

pdf

3470Tender.pdf

pdf

3470TypDrgs.pdf

html

ada00023-e809-4bf3-935f-82aad8b078ef.html

xls

BOQ_888810.xls

pdf

Tendernotice_1.pdf