Tender For Provn Of Direct Pumping Line From 32 Jcos Pump House To P-71 & P-27 Jcos Accn & Connected Works At Asc Centre (South) Pump House Under Ge (Central) Bangalore
Tender Value
41.92 Lakhs
Estimated cost
Bid Submission
26 Oct 2026
8 days left
EMD
84000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Direct Pumping Line From 32 Jcos Pump House To P-71 & P-27 Jcos Accn & Connected Works At Asc Centre (South) Pump House Under Ge (Central) Bangalore
BOQ
| Sl. No. | Item Description |
| 1 | S&F in replacement for Cl sluice valve, non-rising type conforming to IS-14846, sutiable for 150 mm bore pipe consisting of SS spindle as per IS 6603, Cast iron Body, Dome & Wedge as per IS 210, greasy jute type gland packing, fasteners as per IS 1367, Natural rubber gasket, CI manual hand wheel etc complete double end flanged and drilled, of Class PN-1.6 ( ISI marked) including all jointing materials such as rubber gasket insertion sheet nut, bolts and washers etc complete all as specified and directed. |
| 2 | All as per above item No 01 here-in-before but for 100 mm bore pipes complete all as specified and directed. |
| 3 | M & L in replacement for DI pipe special IS : 1536 / IS : 1537 – DI fittings and specials of class 'K7' like tee's, bends, sockets, collar's of junctioning and coupling etc of any type (flanged or socket/spigot type) or in new position with the help of connecting pieces for sizes upto 200 mm dia DI pipe line complete all as specified and directed. |
| 4 | Supply, laying, jointing, testing and commissioning of centrifugally cast ductile iron pressure pipes flanged or socket/spigot type, Class K7, complete with all jointing materials, fittings, specials, testing and incidental works, for potable water distribution systems, IS : 8329 – Ductile iron pressure pipes, ISO 2531 / EN 545 – DI pipes for water pipelines, Internal Lining- Cement mortar lining conforming to ISO 4179, applied centrifugally. Lining shall be smooth, dense and uniform, suitable for potable water. External Coating- Metallic zinc coating of minimum 130 g/m², followed by a finishing layer of bituminous paint / epoxy coating, as per ISO 8179.Coating shall be continuous, well bonded and free from damage, strictly conform to IS : 8329 / ISO 2531 for Class K7 pipes ,100 mm (4”) dia ISI marked suitable for tighten joint in any length laid in trenches including removal of existing old pipe complete all as specified and directed |
| 5 | Supply, laying, jointing, testing and commissioning of centrifugally cast ductile iron pressure pipes flanged or socket/spigot type, Class K7, complete with all jointing materials, fittings, specials, testing and incidental works, for potable water distribution systems, IS : 8329 – Ductile iron pressure pipes, ISO 2531 / EN 545 – DI pipes for water pipelines, Internal Lining- Cement mortar lining conforming to ISO 4179, applied centrifugally. Lining shall be smooth, dense and uniform, suitable for potable water. External Coating- Metallic zinc coating of minimum 130 g/m², followed by a finishing layer of bituminous paint / epoxy coating, as per ISO 8179.Coating shall be continuous, well bonded and free from damage, strictly conform to IS : 8329 / ISO 2531 for Class K7 pipes, 150 mm (6”) dia ISI marked suitable for tighten joint in any length laid in trenches including removal of existing old pipe complete all as specified and directed |
| 6 | Supply & Fix in replacement of cast iron foot valve with strainer 150 mm dia, IS : 4038 – Specification for foot valves, Body-Grey cast iron of grade FG-200 / FG-260, robust construction, Seat: Gun metal integrally fitted and machined, Disc/Valve: Gun metal with rubber facing, Hinge/Spindle: gun metal, Strainer: Cast iron with adequately sized perforations to prevent entry of debris, Fasteners: Stainless steel / galvanized steel, working pressure up to 10 kg/cm², Foot valve shall be installed at the end of suction pipe inside sump/well, It shall be fixed vertically, truly plumb and properly supported, All jointing materials including nuts, bolts, gaskets and flanges shall be provided. complete all as specified and directed. |
| 7 | M&L in replacement of valve pit of size 120x120x90 CM (All internal dimensions of the chamber) including excn and removing the debris to a distance not exceeding 50 Mtr and M & L for brick massonary with cement mortar with 1: 6, 23 cm and flush pointing externaly as the work proceeds in the same mortar complete (using 30% old bricks & 70% New bricks) complete with the following specifications and as directed by Engr-in-Charge :-(i) 10mm thick plaster internally in CM 1:6.(ii) 40mm thick flooring in PCC 1:2:4, type B-1 using 20mm graded aggregate over 75mm thick hard core of guage not exc 63mm thick. (iii) MS Angle iron frame (40x40x6mm) for cover and mild steel sheet 3mm thick cover with locking arrangement, handle and necessary hinges etc (iv) 100mm thick PCC 1:3:6, type C-2 (using 40 mm graded aggregate) in foundation.(v) Two coat of synthetic enamelled paint to cover and frame internally and externally over a paint of Red Oxide primer. |
| 8 | S&F in replacement Cl swing check NRV conforming to IS-5312, sutiable for 150 mm bore pipe consisting Cast iron Body, door as per IS 210, Bronze body ring as per IS 318, natural rubber door face, hinge pin SS ASTM A276 type 410, fasteners as per IS 1367, Natural rubber gasket, etc complete double end flanged and drilled, of Class PN-1.6 ( ISI marked) including all jointing materials such as rubber gasket insertion sheet nut, bolts and washers etc complete all as specified and directed. |
| 9 | Supply & laying, jointing including testing and commissioning of 70 Sqmm 3.5 Core XLPE insulated armoured and PVC sheathed LT 1100 Volt grade and aluminum conductor confirming to IS 7098 laid in trenches/through pipe/ floor/ fixed on walls etc with fixing acessories complete all as specified and directed. |
| 10 | Supply, installation, commissioning and testing of 50 HP Centrifugal Pump Set, squirrel cage, 3-phase, 415V, 50 Hz, TEFC induction motor suitable for pumping application, complete with base from, coupling, vibration pads, terminal box, earthing arrangement and all necessary accessories as required for efficient operation,. The motor shall conform to IS : 325 / IEC standards, minimum IE3 efficiency class, insulation class 'F' with temperature rise limited to class 'B' Motor shall be suitable for outdoor use with IP 55 Protection.Note : The scope incl PCC plinth, alignment with pump set, complete mechanical and electrical connection and trial run to the satisfaction of Engr-in-Charge. |
| 11 | S&F in replacement of Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore, Body: Grey cast iron of grade FG-200 / FG-260, robust and pressure tight, Float: Stainless steel corrosion resistant, Orifice & Seat: Gun metal , precision machined, Lever / Spindle: Stainless steel, Fasteners: Stainless steel / galvanized steel, working pressure up to 10 kg/cm² and fixing up in Cast Iron Water supply mains of size 80 to 150 mm dia complete all as specified and directed. |
| 12 | Supply and laying 50 mm (2”) dia pipe galvanized, “Medium class”, including all type fittings fixed on wall, ceiling, floor and in trenches including removal of existing old pipe complete all as spcified and directed. |
| 13 | Supply and laying 100 mm (4”) dia pipe galvanized, “Medium class”, including all type fittings fixed on wall, ceiling, floor and in trenches including removal of existing old pipe complete all as spcified and directed. |
| 14 | Design, Fabrication, supply, installation, commissioning and testing Double Door Panel board manufactured from CPRI approved firm with canopy head, out door, vertical type panel board of over all min dimension 900mm(H)X700mm(B)X400mm(W) ) fabricated with 3.15mm thick CRCA sheet for outer body and 3.00mm thick for inner partition walls independent cabinate with cabinate doors for MCCBs, Bus Bars, cable trays, metering equipment, floor monted on angle iron frame of mild steel angle iron 75X75X10 mm thick frame totally enclosed type dust & vermin proof back with provision for fixing MCCBs/MCBs necessary inter connections with Aluminium bar/strip duly coloured code insulation and providing under mentioned equipments & accessories including connections of all out going/in coming existing/New cables of required size and including PCC foundation in 1:3:6, type C1 of 0.5 mtrs height above GL and 0.30mtrs below GL including necessary earth work complete all as specified and as directed :- (a) Bus bar aluminium duly insulated with colour coded heat shrinkable sleeve and monted on suitable size of F class insulaors made of non hygroscopic, non combustible, track resistant hight strength FRP insulator 400 Amps for phases and 400 Amps for neutral set of 04 for FYB & N - 01 Set. (b) INCOMING : MCCB 4 pole 415 volts 50 Hz 315 Amp, 36 KA repturing capacity - 01 No (c) OUTGOING : MCCB TP 415 volts 50 Hz 200 Amp, 26 KA repturing capacity - 01 No and MCCB TP/FP 415 volts 50 Hz 160 Amp, 16 KA repturing capacity - 01 No (d) Multi Functional Meter (LED Display) to read KWH, Amps, Volts and frequency etc of each phase - 01 No(e) Indicating lamp LED type for RYB set of 3 - 01 Set (f) FASD starter for 50HP Pump Set with Single Phase Preventer - 02 Nos(g) Complete pannel wiring and labour charges. |
| 15 | Excavation in trenches not exc 1.5m wide and not exc 1.5m deep and getting out in soft / loose soil all as specified and directed. |
| 16 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25cm thick in soft/loose soil, complete all as specified and as directed. |
| 17 | Removing excvated materials (soils) not exc. 50m and deposited where directed at a level not exc. 1.50m above the starting point complete all as specified and as directed. |
| 18 | M&L for Sand cushioning/sand covering for underground cable protection complete all as specified and directed.Note : Punned thickness only will be measured and paid. |
| 19 | Supply and laying sub class 'B' bricks of old size (standard size as per local availability) laid along alignment of cable as protection to cable in trenches complete all as specified and directed |
| 20 | S&F Gun Metal valve, rising type conforming to IS-14846 -2000, sutiable for 50 mm bore pipe consisting of SS spindle as per IS 6603, Cast iron Body, Dome & Wedge as per IS 210, greasy jute type gland packing, fasteners as per IS 1367, Natural rubber gasket, CI manual hand wheel etc complete double end flanged and drilled, of Class PN-1.0 ( ISI marked) including all jointing materials such as rubber gasket insertion sheet nut ,bolts and washers etc complete all as specified and directed |
| 21 | M&L for Earthing complete with Galvanised Steel earthplate electrole of size 60x60cmx6.0mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to GI 25x3mm earth strip by means of nuts, bolts, check nuts and GI washers, connected to earth main electrical eqpts & terminal point including necessary earth work, PCC chamber 1:3:6 type C1 (20 mm graded stone aggregate), 40 mm thick pre cast RCC 1:2:4 type B1 (20 mm graded stone aggregate) cover slab with 8 mm dia TMT bars at 10 cm centre to centre both ways, funnel with watering pipe & protection pipe, wire mesh and lugs complete all specified and all as shown in electrical plate No. 3 of SSR Part-I (2009) . Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysOct 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender