Tender For Providing Rain Water Harvesting, Accessibility To Physically Challenged Persons, Front Elevation, Fire Fighting Arrangements Medical Gas Pipe Line Arrangements For The Work Of Construction Of Additional New Building In Government Hospital
Tender Overview
Project Description
Tender for Providing Rain Water Harvesting, Accessibility To Physically Challenged Persons, Front Elevation, Fire Fighting Arrangements Medical Gas Pipe Line Arrangements For The Work Of Construction Of Additional New Building In Government Hospital At Sulur In Coimbatore District.
BOQ
| Sl. No. | Item Description |
| 1 | EARTH WORK OPEN EXCAVATION by manual means in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers. |
| 2 | Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 3 | Construction BRICKWORK in cement mortar 1:5 (One cement and five M - sand) using best quality Fly ash Brick of size 230x110x70mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge. |
| 4 | FOR FOUNDATION AND BASEMENT. |
| 5 | PLAIN CEMENT CONCRETE 1:5:10 (One cement, five M - sand and ten aggregate) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 6 | Supplying and fixing in position best quality P.V.C. SOIL / WASTE PIPES of following sizes having I.S.I mark and providing leak proof joints including fixing to walls with Specials / PVC /MS. clamps etc., and making connection to all sanitary fittings,dismantling the masonry / RCC works wherever necessary and making good the dismantled portion to original condition etc., complete complying with standard specification.[The PVC pipe should be got approved by the Executive Engineer before use on works.] |
| 7 | 110mm diametre PVC SOIL PIPE [ 6Kg / Cm2] |
| 8 | Supplying and filling 40mm gauge metal in DISPERSION TRENCH etc., complete complying with standard specification and as directed by the departmental officers. |
| 9 | Supplying and filling 20mm gauge metal in DISPERSION TRENCH etc., complete complying with standard specification and as directed by the departmental officers. |
| 10 | Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 11 | PAINTING with TEXTURE PAINTING of best quality and approved colours of texture paint including cost of materials and labour charges for finishing with all necessary accessories in all floors including curing etc,. complete complying with standard specifications. (The paint to be used should be got approved by the executive engineer before use on work.) |
| 12 | Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the departmental Officers. |
| 13 | Supply and fixing of Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and redoing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the departmental Officers. |
| 14 | Supply and fixing of Gas Outlet Points: (Self sealing type - Single / DIN outlet pipe) with 'S' type bracket made up of copper and the out let of non-interchangeable for other gas. The outlet points are brazed with brass bracket with self sealing valve (Stainless Steel) with all accessories and complete set and are covered by plastic cover duly colour coated as per specific gas and button cover etc., complete as directed by the departmental Officers and as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification. |
| 15 | Medical Gas Copper Pipeline arrangement to hang on the wall of socket type connection installation of seamless cleaned and degreased non arsenical phosphorous gas copper pipe line with saddles complete with brazing work including all copper fitting (tee, elbow, reducer, coupling). The copper pipelines should be tested suitable for a steam of working pressure of 17.34 kg. / cm2 (17 bar) and confirm to BS 864 Standard with specially made for brazed socket type connection. The medical gas copper pipeline should be tested as per standard and commissioning after painting as per International Code No. IS 2379/1963 Table-V. The pipelines installed at the various wings and floors etc., complete as directed by the departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification. |
| 16 | 15mm OD 0.90mm Thick Copper Pipe |
| 17 | 10mm OD 0.90mm thick copper pipe |
| 18 | Brass Isolation Valve suitable for the copper pipe and should be of non lubricated 90 degree turn lever ball valve of reputed make, conneced in line with medical gas pipe line system by using suitable size brass valve adopter union, ferrule, nipple, rubber O' ring, tapion lap and etc. All pipe line regulators shall be capable of controlling pipe line pressure and must compatible with the requirements specified in IS 12827-1989. All valves should be pneumatically tested for twice the working pressure for the gas line as per IS Code 12827 / 1989 & ISO 7396 / 1987 Sepecification. |
| 19 | 15mm Isolation Valve |
| 20 | Paving the floor with best quality TACTILE PAVER TYPE OF NEW TEK BT YELLOW COLOUR CERAMIC TILES of size 305 X305 X15mm and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 21 | Supplying , fixing and roofing with colour galvalume sheet of 0.47mm thick with all necessary accessories such as J/U bolt and nuts of suitable length with suitable bitumen washers complete complying with standard specification and as directed by the departmental officers. |
| 22 | Supplying , fixing and roofing with POLYCARBONATE SHEET 6mm thick with all necessary accessories such as J/U bolt and nuts of suitable length with suitable bitumen washers complete complying with standard specification and as directed by the departmental officers. |
| 23 | Supplying. Fabricating and fixing of M S GRILL for open court yard grill, grill work to doors, windows and ventilators with required size and angles including with necessary M.S. Channels, ' L ' angles, M.S. Plate as per the approved special designed including cost of materials and labour charges for cutting angle, welding charges including cost of welding rod conveyance charges at site of work including cost of one coat of red oxide primer etc., complete and as directed by the departmental officers. |
| 24 | PAINTING NEW IRON WORKS works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 25 | GST 18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender