Tender For Mtps - I - Tm - Unit - Ii - Renewal Of Gasket At Water Box Side, Tube Nest Side, Condensate Inlet And Outlet Flange, Inspection And Cleaning Of Tube Nest And Hydraulic Testing Of Lph-2/ 3/ 4, Gc-1, Ejector 2A, Vent Condenser And Renewal Of

Issued by Boards / Undertakings / PSU · Salem, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
21 Oct 2026
14 days left
EMD
6200
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Salem → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Mtps - I - Tm - Unit - Ii - Renewal Of Gasket At Water Box Side, Tube Nest Side, Condensate Inlet And Outlet Flange, Inspection And Cleaning Of Tube Nest And Hydraulic Testing Of Lph-2/ 3/ 4, Gc-1, Ejector 2A, Vent Condenser And Renewal Of Gasket At Deaerator Main Flange, Deaerator Lines Flanges At Deaerator End And Overhauling Of Safety Relief Valves In Hphs & Deaerator Tank During Annual Overhauling Work 2026-27.

BOQ

Name of Work:- MTPS - I - TM – Unit – II - Renewal of Gasket at water box side, tube nest side, condensate inlet and outlet flange, inspection and cleaning of tube nest and hydraulic testing of LPH-2/ 3/ 4, GC-1, Ejector 2A, Vent condenser and Renewal of Gasket at Deaerator main flange, Deaerator lines flanges at Deaerator end and overhauling of Safety Relief Valves in HPHs & Deaerator tank during Annual Overhauling Work 2026-27.
Sl. No. Item Description
1Overhauling and Gasket renewal of LP Heater2/3/4.a) Removing of water box and placing it on the repair bay.
2b) Lifting of tube nest, placing it on the T.G. floor, inspection, cleaning of tube nest and shell etc.
3c) Preparation of gaskets for the tube nest, water box inlet and outlet pipe line flanges etc.
4d) Providing new gaskets for the tube nest and placing the tube nest inside the shell.
5e) Cleaning and checking of drip line Header Nozzle holes, Checking the tube nest for leak if any plugging of all punctured tubes, placing the water box on the tube nest and tightening of main flange, Condensate inlet and outlet flanges after providing new gaskets.
6Overhauling and Gasket renewal of Gland Cooler 1 a) Removal of Water box, flange bolts and nuts, Condensate inlet and outlet flanges, lifting the water box, placing it on the floor and cleaning of all flange surfaces.
7b) Lifting of tube nest, Placing it on the floor, inspection, cleaning of tube nest and hydraulic testing etc.
8c) Providing new gasket, for the tube nest and placing the tube nest inside the shell.
9d) Placing the water box on the tube nest and tightening the main flange, Condensate inlet and outlet flanges after providing new gasket.
10Renewal of Feed water tank manual gaskets, HP Heaters, Drip lines, and BFP Re-circulation lines flange gasket at Deaerator end cleaning inside the feed water tank including consumables.a) Opening of manhole cover of feed water storage tank both sides and gasket preparation for the manhole.
11b) Inspection of trays and sampling lines and cleaning of feed water tank.
12c) Changing of gaskets in HP Heaters drip line flanges and BFP's Re-circulation line flange at Deaerator.
13d) Assembling of manhole covers with new gaskets after cleaning the old gaskets. (Tag No. Deaerator feed tank and it’s connected Drip lines, BFP’s RC line flange)
14Overhauling and Hydraulic testing and Re-assembling of Safety valve size 6”/8”/ 40/64 ATA Removing the safety Relief valve size 6”, 8” / 40, 64 ATA, Disassembling the Safety Relief Valve, cleaning all the parts of the SRV, checking the seating surfaces, Lapping the seat and disc for perfect blue matching. Setting the pressure for rated lifting the SRV with hydraulic pump. Reassembling the SRV with new inlet and outlet flange gaskets. (Tag.No. HP Heater’s SRVs = 8 Nos., Deaerator SRVs – 3 Nos., Total-11 Nos.)
15Overhauling Hydraulic test and Re-assembling of Safety valve of size 4”/2”/ 300 class. Removing the safety Relief valve Size 4’’, 2.5’’/ 339 Class from LP Heater, Gland cooler-I Flange & Stud heating system Disassembling the Safety Relief Valve, cleaning all the parts of the SRV, checking the seating surfaces, Lapping the seat and disc for perfect blue matching. Setting the pressure for rated lifting the SRV with hydraulic pump. Reassembling the SRV with new inlet and outlet flange gaskets.(Tag No- LP Heater-2,3,4 & GC-2- 4 Nos. and Flange & stud heating SRV- 4 Nos. Total-8Nos.)
16Inspection and Gasket Renewal of MainEjector.Disconnecting of all the steam pipe lines air lines and dismantling the nozzle box, Ejector shell, tube nest etc cleaning the tubes, water box, attending the tube puncture, setting and checking the nozzle gap, hydraulic testing of the tubes and assembling the ejector shell, tube nest, nozzle box, providing with new gasket connecting all the related pipe lines, overhauling of exit NRV and flow meter in main ejector as per direction of the Engineer in charge. (Ejector-2A)
17Dismantling the Vent Condenser, water box and connected pipe lines, cleaning the water box tube nest flanges and connected pipe line flanges and renewal of gaskets, inspecting the tube nest for leak. Removing studs and nuts in the vent condenser main flange, condensate inlet and outlet pipe line and placing it on the platform. Removing water box, cleaning water box and shell flanges.
18Taking out the Vent condenser Tube Nest from the Vent Condenser Shell and tilting the tube nest for 180 degrees.
19Positioning the tube nest inside the shell and assembling of water box and all connected pipe lines after providing gaskets and tightening of all flanges stud and nut etc.(Vent condenser)
20Champion Make Style – 54 Super Metallic Compressed Asbestos fiber Jointing sheet confirm to IS 2712/1998, Grade W/1, Size 2000 x 1500 x 3mm Drive End/Heater Drip Pump/ Model: NU 411 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57898014
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 21-10-2026
Authority
Authority Name Tamil Nadu Generation And Distribution Corporation Limited
Work Description Tender for Mtps - I - Tm - Unit - Ii - Renewal Of Gasket At Water Box Side, Tube Nest Side, Condensate Inlet And Outlet Flange, Inspection And Cleaning Of Tube Nest And Hydraulic Testing Of Lph-2/ 3/ 4, Gc-1, Ejector 2A, Vent Condenser And Renewal Of Gasket At Deaerator Main Flange, Deaerator Lines Flanges At Deaerator End And Overhauling Of Safety Relief Valves In Hphs & Deaerator Tank During Annual Overhauling Work 2026-27.
Basic Detail
Tender No CE / MTPS-I / SE / M-I / TM / OT. 152 / 2026-27
Bidding Type Tender
Location
City Salem
State Tamil Nadu
Key Dates
Publish Date 07 Oct 2026
Submission Date 21 Oct 2026
Open Date 22 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 6200
Exemption Available
Document List
1f926383-60d1-4075-b6b6-8a016b3e1893.html
BOQ_854440.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 07, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Oct 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Oct 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

1f926383-60d1-4075-b6b6-8a016b3e1893.html

xls

BOQ_854440.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender