Housing Urban and Rular Development Government Departments Closing in 14 days TDR #57894520

Tender For Replace All The Existing Window Ac Machine To New Concealed Split Air Conditioning System Inside The Sncu And Supply Installation Testing and Commissioning of New Ac Machine For Triage Area Of Bolpur Sub Division Hospital, Bolpur, Birbhum.

Issued by Government Departments · Kolkata, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
28 Oct 2026
14 days left
EMD
34810
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Replace All The Existing Window Ac Machine To New Concealed Split Air Conditioning System Inside The Sncu And Supply Installation Testing and Commissioning of New Ac Machine For Triage Area Of Bolpur Sub Division Hospital, Bolpur, Birbhum. Rn25001394.,Project Id:- Hf262752140s000

BOQ

Name of Work:- Replace all the existing Window AC Machine to New Concealed Split Air Conditioning System inside the SNCU and SITC of New AC Machine for Triage area of Bolpur Sub Division Hospital, Bolpur, Birbhum. RN25001394.,Project ID:- HF262752140S000
Sl. No. Item Description
1PART A : DISMANTALING OF EXISTING AIR CONDITIONERS:Dismantling of 230 Volt, 1.5 TR window type AC machine and all related equipments in proper process and deposit it to the sectional store in well manner.
2Dismantling of 230 Volt, 2.2 TR split type AC machine with all related equipments both indoor and outdoor unit in proper process & mending good damages. Desmintaling AC deposit it to the sectional store in well manner.
3Cover the window area after dismantaling the window AC Machine by 3mm ACP sheet by necessary fixing arrangement.
4PART B : SITC OF NEW AIR CONDITIONERS:S&D of minimum 14.07KW nominal cooling capacity ceiling suspended [Concealed] Split Air Conditioner with R410A / R407C / R-32 Refrigerant, with single Twin Rotary compressor inverter machine, suitable for operation on 415V,+_ 5% , 50Hz, 3Ph AC Supply. with precharged refrigerant, Wired/ Wireless remote & all other accessories. (Make : O General model ARGG48CMAA/AOGG48CRAB or equivalent to Mitsubishi heavy industries.) As per choice of EIC.
5Installation testing & commissioning of above AC machines at 1st floor by fixing the indoor with two number 1.5mt long MS equal angle of sizes 50mmX50mmX 6mm to fixed by 250mm grouting on wall with 2nos strut of suitable length. The indoor unit suspended from this angle support with 4 nos 10mm full threaded suspender bolt with double nut & spring washer. Out door unit will be fixed on roof with iron chair of size 900mmX 300mm of height 300mm made by 50mmX50mmX6mm MS angel incl painting by two coat of synthetic enamel paint over one coat of RO primer, as per direction of EIC.
6Supply & Laying of Refrigerant Copper pipe of following diameter for connecting of Indoor to Outdoor unit, along with drip resistant nitrile rubber insulation with double insulating wrapping tape to avoid dripping of condensate water:-
7Discharge Line 9.52mm dia, min. thickness 0.8mm with 9mm thick nitrile insulation. (Make : Rajco / Royku).
8Suction Line 15.88mm dia, min. thickness 0.99mm with 9mm thick nitrile insulation. (Make : Rajco / Royku).
9Supply & Laying of PVC insulated unarmoured 1.1 KV grade 6 Core 2.5sq mm copper cable from indoor to outdoor unit with necessary fixing arrangement. (Finolex / Polycab / Havells)
10Wrapping the copper pipe with insulation & electric cable by S/F 26SWG Aluminimum sheet to make it weather & vermin proff.
119.5mm dia with 9mm thick nitrile insulation, 15.88mm dia with 9mm thick nitrile insulation & 6core 2.5Sqmm Copper cable.
12Supply & laying drain Water piping work with 25 mm dia Schedule 40 PVC/ UPVC hard pipes (Finolex / Ashirbad / Supreme) incl. fitting , accessories bends, elbows, tees, flanges, tapings, etc. insulated with 9mm. thick nitrile rubber tube insulation.
13S&F flexible canvas connection for indoor to duct/ air terminal for
1414.07 KW indoor
15SITC of Powder Coated Al. Grill without VCD suitable size (Make:Systemair / Primier)
16S & providing drop ceiling to cover the indoor units & supply air duct including the cost of 3mm thick ACP sheet as per manufacturer's specification on the frame work fabricated from Aluminium hollow rectangular section of size 50mm x 25mm (2mm thick) & duly suspended by Aluminium hollow rectangular section of size 50mm x 38mm (2mm thick) and silicon sealent complete in all respect including making trap door arrangement as per direction of EIC. (Make:Aludecor/Pratapbond)
17PART C : EI WORKS:Supplying and fixing 415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc. (Make- HPL/L&T/Standard)
18Supply & Drawing of 4x70sqmm 360 N/0.5 mm copper flexible wire.
19Supply & fixing of long barrel copper socket for 70sqmm copper conductor.
20Supply & Installation of outdoor type feeder pillar of dimension 1500mm height, 1200mm width & 200mm depth with hooded type construction, fabricated from 3mm thick CRCA sheet & finished with powder coted heat paint over RO primer. The feeder pillar must have provision of fixing 8 way VTPN with the provision to accommodate incoming 4 core 70sq. mm. PVC/Al cable and outgoing 6 & 4 sq. mm. cables. This feeder pillar have 4nos 600mm height legs fixed on roof floor incl. muffing of these legs.
21Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on above feeder pilar box incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make - Legrand /Siemens/Schneider)
22Up to 160A, 8 way Enclosure
23Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection as per GS (Make- Legrand/L&T/Havells/Siemens)
246-32 A TP
25Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting with incomer spreader link in existing DBs / enclosure and necessary connection. For VTPN DB (Make :- Legrand /Siemens/Schneider)
26125 A
27Supplying & Fixing of PVC water proof type Loop box (Make-Sintex GSJB2520 /Hensel) of size [250X200X100]mm having hinged PVC top cover & 4 mm thick with rubber gasket lining,railway type mechanical locking arrangement, with DIN rail. on wall as per direction of EIC.
28S&F of 615V, 63A, 4 Pole Terminal Stud with necessary connection.
29S.I.T.C. of Crono time switch [Make - L&T Cat. No. 67DDT0]
30S & F of 4 pole 25A DIN rail mounted Power contactor with 240V operating coil [ make L&T/ ABB/ Siemens/ Schneider].
31Supplying & Fixing GI Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.2 Module
32Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required
33Supply & Fixing 240 V Modular type indicator (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required
34Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make, HMS quality) incl. necy. fittings as required
352 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
36Supply & Laying 25mm dia Galvanized steel flexible conduit with PVC coating (Precision make) incl. necy. fittings as required
37S&F of Steel wire reinforced flexible PVC Conduit Gland 25mm dia.
38Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid flexible conduit incl necy. connection as required.4x56/0.3 (4 sqmm) + 2x36/0.3 (2.5 sqmm) as ECC
39Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% on roof floor with 150mm above by means of D type iron chair made by 25mmX6mm GI flat ( 1nos per meter), bolts & nuts, etc. as required of the following size. 100x50x1.25mm (18SWG)
40Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the 25mm size PVC rigid conduit 'FR' HMS (Precision make) / flexible conduit and making necy. connection as required
414 x 56/0.3 (4 sqmm) + 2 x 36/0.3 (2.5 sqmm) ECC
42Supply of PVC/ XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make- Havells/RR/Universal/ Polycab/ Gloster As per choice of EIC]
434 core 70 sqmm
44Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
45Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
464 core upto 70 sqmm
47Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
484core 70 sqmm cable
49Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
502.5 Sq mm
514 Sq mm
52THERMAL / UNDERDECK INSULATION :SITC of GI DUCT of Class - VIII grade for supply/return air duct along with pre fabricated plenum for supply and return air with necessary supports, flanges etc. as required and as per IS 655 and IS-277 standards of following gauges. (Make - Sail )
5324 SWG thick
54Supplying & fixing of 19 mm thick duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation. (Make - Armacell / K Flex)
55Supply & fixing of underdeck insulation with 50mm thick TF quality Expanded polysterene slab. (Make - Thermowell ) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57894520
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 28-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Replace All The Existing Window Ac Machine To New Concealed Split Air Conditioning System Inside The Sncu And Supply Installation Testing and Commissioning of New Ac Machine For Triage Area Of Bolpur Sub Division Hospital, Bolpur, Birbhum. Rn25001394.,Project Id:- Hf262752140s000
Basic Detail
Tender No WBPWD/SSEWEC /BRED /NIQ-60 /2026-27
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 06 Oct 2026
Submission Date 28 Oct 2026
Open Date 30 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 34810
Exemption Not Available
Document List
BOQ_5175922.xls
ef1bd2ec-a79c-4f0f-ade3-c9c60013cd98.html
new2911.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Oct 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_5175922.xls

html

ef1bd2ec-a79c-4f0f-ade3-c9c60013cd98.html

pdf

new2911.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender