Tender For Electrical Renovation And Installation Work At Kanchanpur Bphc Hospital In The District Of Bankura.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
23 Oct 2026
14 days left
EMD
86445
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Purulia → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Electrical Renovation And Installation Work At Kanchanpur Bphc Hospital In The District Of Bankura.
BOQ
| Sl. No. | Item Description |
| 1 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make:- Gloster/KEI/Polycab/Havells/Mescab) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] |
| 2 | Average run 8 mtr |
| 3 | Average run 9 mtr |
| 4 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish. On Board |
| 5 | Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. [Make: LK(L&T)/Siemens/ABB/Havells] |
| 6 | 160 A |
| 7 | Supplying and fixing 415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc. [Make: LK(L&T)/Siemens/ABB/Havells] |
| 8 | Supplying & fixing sheet metal inspection box (16 SWG) of the following sizes ( in mm) flushed in wall as per GS |
| 9 | 175 x 100 x 65 |
| 10 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Make: Legrand/Siemens/ABB] |
| 11 | 6 way (upto 160A) |
| 12 | 8 way (upto 160A) |
| 13 | 4 way (upto 160A) |
| 14 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Make: Legrand/Siemens/ABB] |
| 15 | 8 way |
| 16 | 6 Way |
| 17 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Make: Legrand/Siemens/ABB] |
| 18 | 2+10 Way |
| 19 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS. [Make: Legrand/Siemens/ABB] |
| 20 | 40 A DP |
| 21 | 63 A FP |
| 22 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection as per GS. [Make: Legrand/Siemens/ABB] |
| 23 | 6-32 SP |
| 24 | 63 A TP |
| 25 | Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA in existing Vertical DBs including necessary connection as per GS. [Make: Legrand/Siemens/ABB] |
| 26 | 160 A FP |
| 27 | 100 A FP |
| 28 | Supplying and Drawing 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed single core stranded copper wire (Make:- KEI/Havells/Polycab/Gloster) of the following sizes in the prelaid polythene pipe as per GS. |
| 29 | 2x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) |
| 30 | 2x36/0.3 (2.5 sqmm)+1x 22/0.3 (1.5 sqmm) |
| 31 | 2x 4 sqmm+1x 2.5 sq.mm. |
| 32 | 2x 6.0 sqmm + 1x 4 sqmm |
| 33 | Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS. |
| 34 | 19 mm dia 3 mm thick |
| 35 | 25mm dia 3 mm thick |
| 36 | Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 37 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 6 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. as per G.S |
| 38 | Supply & Fixing 240 V, 3 nos. 16 A, 3 pin Modular type plug socket with 3 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 12 Module GI Modular type switch board with 2 row 12 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc |
| 39 | Supply & Fixing 240 V, 2 nos. 5 A, 3 pin Modular type plug socket with 2 nos. 5 A Modular type switch (Brand approved by EIC), Indicator without plug top on GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc, with connector as per G.S. |
| 40 | Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make-Gloster/KEI/Polycab/ RR Cable/ Havells] |
| 41 | 4 Core 95 sq.mm. |
| 42 | 4 Core 70 sq.mm. |
| 43 | 4 Core 50 Sq. mm |
| 44 | 4 Core 25 Sq. mm |
| 45 | 4 Core 35 Sq. mm |
| 46 | 2 Core 10 Sq. mm |
| 47 | 4 Core 10 Sq. mm |
| 48 | Laying of cable after cutting floor/pavement/wall as per GS for the following Sizes. |
| 49 | 2.5 to 35 Sq. mm [ 5(i)/ F- 3 ] |
| 50 | above 35 to 95 Sq. mm [ 5(ii)/ F- 3 ] |
| 51 | Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. |
| 52 | Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core by crimping method incl supply and fxing of solderless socket (dowells make) as per GS. |
| 53 | 4 Core 95 sq.mm. |
| 54 | 4 Core 70 sq.mm. |
| 55 | 4 Core 50 Sq. mm |
| 56 | 4 Core 25 Sq. mm |
| 57 | 4 Core 35 Sq. mm |
| 58 | 2 Core 10 Sq. mm |
| 59 | 4 Core 10 Sq. mm |
| 60 | Excavation of soil for installation of Earth Electrode and filling & ramming as per GS |
| 61 | For Morum Soil |
| 62 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: (a) By TATA M GI pipe |
| 63 | Connecting the equipments body to earth busbar including s & F Solid GI (Hot Dip) wire of size as below as per GS. 4 SWG |
| 64 | Supply & Fixing earth busbar of galvanised (Hot Dip) MS Flat 25 mm x 6 mm on wall as per GS. |
| 65 | Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991) 4 bars 415 V, 415 A 4 x 50x5mm |
| 66 | Supply & Delivery of Single LED Tube light fittings (make- Philips, Cat No. TMC-502 P1xT-LED 22W / equivalent model of Crompton Fittings- LTT8-20 1 x T8 with 01 Nos LED TUBE Philips Cat No- Mas LED Tube 1200mm 18W 865 T8 I – 2100 lm /Crompton- Cat No- CIS-341- 20-65--SL-NWH or equivalent model of Havells) |
| 67 | Supply & Delivery of twin LED Tube light fittings (Make- Signify (Philips), Cat No. TMC-502 2XT-LED 22W or equivalent model of Crompton Fittings- LTT8-20 2 x T8 with 02 Nos LED TUBE Philips Cat No- Mas LEDTube 1200mm 18W 865 T8 I – 2100lm /Crompton- Cat No- CIS-341-40-65--SL-NWH or equivalent model of Havells) |
| 68 | Supply and fixing 9 W LED light fitting. (Make: Philips(Signify)/ Havells/Crompton) |
| 69 | Supply & Fixing 240 V Modular Socket type fan regulator (Step type)(Brand approved by EIC) on existing sheet metal switch board as per GS |
| 70 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS |
| 71 | Fixing only exhaust fan after making holes in wall as per GS. (12\\") |
| 72 | Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall as per GS. (12\\") |
| 73 | Supply & Fixing of 200mm dia PVC decorative ceiling cover plate for ceiling fans |
| 74 | Supply & delivery of AC 240V 50 Hz 1400 mm sweep ceiling fan complete with a down rod, Canopy, fork incl S & F of S-3 type capacitor as per IS specification & proper Manufacturer certificate of the capacitor and Safety Wire (supplied at the time of delivering the fans ), etc. without regulator, (Make- Usha 1400MM STRIKER PWD ISI 1 STAR (Safety Wire & S3 Capacitor) / Orient Electric 1400 mm sweep; 56W; 300 rpm; 255 cmm; 2 star ac ceiling fan or equivalent make of Crompton Greaves ) and as per direction of EIC as per direction of EIC. |
| 75 | Supply and delivery of Exhaust fans complete with all accessories having the following (Make -EPC/ Orient Electric Heavy Duty /USHA Heavy Duty) 12\\" Speed 920 RPM |
| 76 | Supply and fixing of 230 V, 50 HZ, 450 mm, , high flo oscillating type, metal blades and metal canopy Wall Bracket fan ( Make:- Crompton Cat No- 450mm STORM 2 Plus ( METAL BLADE) /Orient Electric/USHA) |
| 77 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand Approved by EIC ) , without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 78 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand Approved by EIC) & necy. Connections. |
| 79 | Supply and fixing of OLP 3+ 25A Starter incorporative in a box having a 6-32 Amp MCB SPN compsite flash type in the box made of 16 SWG CRC sheet with bakelike top cover and earthing attachment in conceal in wall as per G.S |
| 80 | Supply and fixing of 240V,45 W LED Street light. (Make: Signify (Philips) Cat no. BRP331 LED54 CW R5N PC PSU S1V1/ Crompton Cat No. CRP 409-45-57-SL-GL- NSG or equivalent model of Havells) |
| 81 | Supply and Fixing of Timer DB (concealed in wall) comprising of the following instruments,1) 230V, Digital Timer Switch. (Make: LK(L&T) Cat No. 69HDT0/ Legrand /Siemens) 2) 3 Pole Power Contrcator (Make:- L&T-MNX 32-3P Cat No-CS94111/Siemens/Schneider ),3) 32A FP MCB. (Make-Siemens/Schneider/Lauritz Knudsen (L&T) )5) Toggle Switch. (Make-Siemens/Schneider/Lauritz Knudsen (L&T) or equivalent make) 5) (2+12 Way) SPNDB (Make-Siemens/Schneider/Lauritz Knudsen (L&T) 6) Bakelite base with FP bolt type stud / Terminal block incl S & F Neutral Bar etc with this box for termination of power. 7) The complete arrangement must be wiring by 1.5/2.5/4 Sq mm PVC insulated Cu wire (Make:- Gloster/Polycab/Havells) with suitable length incl socketing /lugs etc as per requirement & direction of EIC |
| 82 | Supplying & Fixing of PVC water proof type Loop box (Make-Sintex) of size 8\\"X10\\" comprising of 4 way 100 Amp. Capacity brass stud/terminal make- AC /DC.,having hinged PVC top cover & 4 mm thick with rubber gasket lining,railway type mechanical locking arrangement,comprising of one 250V,15A kit-kat fuse unit,one NL on porcelain insulator etc. conceal in wall as per direction of EIC |
| 83 | S & F 40 mm. dia. G.I.(M) 1.0 Mtr. Long arm bracket for fixing flood light & neccy connection by 2x 1.5 sq mm Cu wire incl. painting with two coats of RO primer as per direction of EIC. |
| 84 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required |
| 85 | SITC OF CPRI-APPROVED FLOOR-MOUNTED INDOOR TYPE CUBICAL LT DISTRIBUTION PANEL:1) Supply, Installation, Testing and Commissioning (SITC) of CPRI-approved, floor-mounted, indoor type cubical LT Distribution Panel, suitable for 3-phase, 4-wire, 400/415 V, 50 Hz AC supply, complete in all respects as per the approved design, electrical schematic and constructional drawing.2) The panel shall be of floor-mounted, compartmentalised, cubical type, fabricated by a CPRI-approved/empanelled manufacturer/fabricator, and shall comply with the relevant provisions of IS 8623 (Part 1):1993 / IEC 61439-1 & IEC 61439-2, with latest amendments, as applicable to the panel.Panel Construction:-1) The panel shall be fabricated from 2 mm thick MS sheet, suitably stiffened with suitable size MS Angle , wherever required for adequate mechanical strength.2) The panel shall be floor-mounted, self-supporting, cubical and suitable for indoor installation.3) The base frame/base plate shall be fabricated from 5 mm thick MS plate.4) The panel shall be provided with suitable doors/covers, hinges, locking arrangements, cable entry/termination arrangements and removable gland plates.5) The enclosure shall have suitable surface treatment and approved powder-coating/painting system for indoor installation. |
| 86 | Internal Segregation and Arrangement: i) The panel shall be suitably compartmentalised for safe operation and maintenance.ii) Suitable segregation/shrouding shall be provided for busbars and live parts to prevent accidental contact.iii) All internal components, supports, busbars, wiring and accessories shall be suitably rated for the specified voltage, fault level and load. |
| 87 | 4. Drawings and Approval: Before commencement of fabrication, the contractor shall submit the following to the Engineer-in-Charge (EIC) for approval:1) Panel General Arrangement/Constructional Drawing, showing overall dimensions, sections/compartments, busbar arrangement, component mounting, cable entry/termination and internal layout.2) Electrical Schematic/Single Line Diagram, clearly indicating the Normal and Emergency sections, incoming and outgoing feeders, busbars, switching/protection arrangements and interconnections.3) Fabrication of the panel shall not be commenced without approval of the constructional and electrical drawings by the EIC. |
| 88 | 5. The LT Panel shall be fabricated and assembled by a CPRI-approved/recognized panel builder. The Contractor/bidder shall submit valid CPRI approval/recognition documents of the panel builder to the Engineer-in-Charge (E.I.C.) for approval before commencement of fabrication of the panel. Please Enable Macros to View BoQ information |
| 89 | 5. The LT Panel shall be fabricated and assembled by a CPRI-approved/recognized panel builder. The Contractor/bidder shall submit valid CPRI approval/recognition documents of the panel builder to the Engineer-in-Charge (E.I.C.) for approval before commencement of fabrication of the panel. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysOct 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender