Defence Statutory Bodies & Commissions/Committees Closing in 8 days TDR #57892892

Tender For Addition/Alteration To Bldg No P-351 (Gas Godown) And Allied Facilities At Hq Wac Subroto Park

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
43.66 Lakhs
Estimated cost
Bid Submission
26 Oct 2026
8 days left
EMD
87320
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Addition/Alteration To Bldg No P-351 (Gas Godown) And Allied Facilities At Hq Wac Subroto Park

BOQ

Name of Work:- ADDN/ALTN TO BLDG NO P-351 (GAS GODOWN) AND ALLIED FACILITIES AT HQ WAC SUBROTO PARK
Sl. No. Item Description
1Surface excavation Soft/loose soil n.exc (not exceeding) 30cm deep and averaging 15 deep and getting out complete all as specified and directed.
2M & L for hard core of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed.
3M&L for PCC 1:4:8 type D2,(using 40mm graded stone aggregates) as in foundation,filling and mass concrete all as specified and directed.
4M&L for 40 mm thick Cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in sub floors, sub bases , floors and paving's/ paver blocks etc complete all as specified and directed.
5Removing excavated soil material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified an directed.
6M&L prepare rough concrete surface by brushing with wire brushes and removing dust , loose materials etc, sweeping with brooms and finally fanning the cleaned surface with air blown compressor to remove all loose dirt etc and providing & laying 40mm thick Antistatic Bitumastic flooring conforming to IS 8374-1977 for Specification and IS 1196-1973 for laying bitumastic flooring and having material specification as below I) Bitumen (90x15 or 75/15) grade : 13-15% ii) Carbon black of conductive grade like Graphite : 5-7% iii) Stone dust (clean) : 30% iv) Stone girt (max 6mm size : 20% v) Lime stone dust(80 to 90% Calcium 30%) laid and spread uniformely and compacted with hand roller to a uniform smmoth surface complete all as specified and directed.
7Dismantling plain corrugated steel sheeting any gauage thick ness including Nainital and similar pattern complete all as specifed and directed.
8S&F for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
9S&F for Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
10Dismantling wrought iron or mild steel work of any description not otherwise provided for etc complete all as specified and directed.
11S & F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing iron gates, iron stages (Beam, tee, angle, channel, sheets or flat sections) including distance pieces, cleats etc of Fe 410-W (Gde E- 250) quality A complete all as specified and as directed.
12M&L for two coats synthetic enamel paint over a coat of red oxide primer on steel surfaces of any description not otherwise described over 10 cm width or girth including preparation of surfaces complete all as specified.
13Demolition of brick/concrete block walling, in cement mortar including all quoins archas pillars etc and pre-cast block walling etc complete all as specifed and directed.
14M & L for brick work with sub-class `B' bricks old size, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:4 complete all as specified and directed.
15M&L for PCC 1:4:8 type D2,(using 40mm graded stone aggregates) as in foundation,filling and mass concrete complete all as specified and directed.
16M & L for providing reinforced cement concrete 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in copping, shelves roof kerbs or mud stops, rounded or chamfered edges, including necessary formwork complete all as specified and directed.
17Taking down cement plaster on brick or stone wall etc incl raking out joints hacking for key scrubbing down with water complete all as specifed and directed.
18M&L for 15 mm thick rendering in cement mortar 1:4 or fair faces of brick or cement concrete surfaces finished even and smooth without using extra cement complete all as specifed and directed.
19M&L for rendering 15mm thick on other than fair faces of brick work or concrete surfaces (Cement plaster 1:6) finished even and smooth without using extra cement complete all as specified and as directed.
20M&L for preparing new surface and applying exterior paint (weather coat, apex ultima) of required shade,Two coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm, complete all as specified and as directed.
21M & L Preparation of newly plastered or unplastered surface and applying two coats of distemper oil emulsion over a coat of primer on walls complete all as specified and directed.
22M&L for 80mm thick, M-40 Grade Machine pressed precast concrete pre-painted interlocking paver block any shape and size casted in plastic moulds and competed on vibratory table confirming to IS 15658-2006 with grey cement and pigment complete all as specified and directed.
23M&L for 75 mm thick PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed.
24M&L for Sand filling under floors or in foundation including watering and consolidation complete all as specified and directed.
25S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of andard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as rected (each line wire to be measured complete all as specified and as directed.
26S&F for rotational molded polyethylene water storage tanks (white colour) of 1000 ltrs capacity (cylindrical vertical with closed threaded top) hoisted and fixed in position including 20mm dia HD polythene float (ball) and epoxy coated aluminum rod (fly nut) screwed for iron pipe or brass ferrule complete all as specified and directed.
27S&F steel water tubing, galvanised, medium grade, ISI marked with all fittings and fixed on walls and ceilings or laid in floors bore of pipe 15 mm complete all as specified and directed.
28S&F steel water tubing, galvanised, medium grade, ISI marked with all fittings and fixed on walls and ceilings or laid in floors bore of pipe 20 mm complete all as specified and directed.
29S&F CP bib taps long body , cast copper alloy, fancy type with crutch or butterfly handles, chromium plated, screwed down to iron pipes or for brass ferrule of 15 mm bore complete all as specified and directed.
30S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe & fixed dia of bore of pipe 20mm complete all as specified and directed.
31S&F double lever non corrodible wire mesh of copper with appropriate and approved guage to be fixed with tinned tacks or copper wire staple complete all as specifed and directed.
32Supply and hang 10 liter GALVANIZED MILD STEEL FIRE BUCKET (Fire suppression hand tools) , Conforming to IS:2546 latest complete all as specified and directed.
33Supplying and installing portable fire extinguisher suitable for class B and class C fire hazard in LPG storage/ gas godown areas, conforming to relevant indian standards and statutory fire safety requirements . Extinguisher shall be of stored -pressure type with seamless steel cylinder, corrosion-reistant finish , discharge hose and safety pin . 9 kg dry chemical powder (DCP) fire extinguisher suitable for flammable gas and liquid fire, and 4.5 kg CO2 fire extinguisher for electrical and gas fire risk. extinguisher shall omply with applicable standards such as bureau of indian standards and rlated fire safety codes. units shall be installed at accessible locations with proper signage , mounting arrangemnts and unobstructed access all as specified and directed.
34S& F 110 mm bore PVC (SWR ) pipe single socketed in any length with rubber ring joints, laid in trenches/floors/wall (using GI half round Clamp etc including removing from site complete all as specified and directed.
35M&L for 16-18mm thick granite slab on top of cooking plateform, bar counter and simillar work including cutting polishing rounding on edge etc machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone over and including 15mm thick screed bed in CM 1:4. including grinding and polishing complete all as specified and directed.
36M&L for 16-18mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall with any height) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, cutting polishing rounding on edge etc machine cut, bedded, jointed with grey cement slurry, pointed with white cement with admixture of pigment to match the shade of granite stone and holding with brass screw complete all as specified and directed.
37M&L for removal of old malba , (debris) incluiding old broken bricks , rcc debris and all using trolley tractor ,load not execeeding 3 cum per load , loading trolley to full capacity and leveling the surface of land and disposing debris outside MOD land as per directed.
38M&L for removal of sherbs at site and trimming dead branches and over grown branches , and clearing the over grown sherbs complete all as specified and directed.
39M&L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete all as specified and as directed.
40Excavation in trenches n.exc 1.5m wide and n.exc1.5 m in depth for foundation, or shafts, wells, cess pits manholes, pier holes etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in any type of soil / rock (soft / hard / dense soil /rock) complete all as specified and directed.
41Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm complete all as specified and directed.
42Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed out side MOD land complete all as specified and directed.
43M & L for Mild steel TMT bars, 10 mm dia and over, cut to length, bent to shape rwquired including cranking bending, spirally for hooping for columns, hooking ends and binding with and including mild syteel wire (annealed) not less than 0.9 mm dia, complete all as specified and directed.
44S&F milt steel TMT bars 6 to 8mm dia , cut to length, bent to shape requred, including crancing bending and binding with mild steel (anneal) wire not less than 0.90mm dia complete all as directed and specified and directed.
45M & L for Formwork to sides of concrete foundation, bases of column vertical or to batter (rough finished flat surfaces of concrete), complete all as specified and directed.
46M&L for providing reinforcement cement concrete 1:2:4 type B1 (using 20mm graded stone agg) as in slabs/ beams/column in floors balconies,canopies, desc slabs and the shelves and the like complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57892892
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 43.66 Lakhs
LAST DATE 26-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Addition/Alteration To Bldg No P-351 (Gas Godown) And Allied Facilities At Hq Wac Subroto Park
Basic Detail
Tender No GE/SP/TOKEN-63/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 06 Oct 2026
Submission Date 26 Oct 2026
Open Date 29 Oct 2026
Finance
Tender Value 43.66 Lakhs
Tender Fee 500
EMD 87320
Exemption Available
Document List
8b96e092-f149-4810-9433-49521e36fe85.html
BOQ_888617.xls
TENDER63.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Oct 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

8b96e092-f149-4810-9433-49521e36fe85.html

xls

BOQ_888617.xls

pdf

TENDER63.pdf

pdf

Tendernotice_1.pdf

Disclaimer