Tender For Repair/Maintenance Of Fire Detection & Fire Fighting System Along With Periodic Maintenance And Repairs Of Various Lifts Under Af Stn Sirsa
Tender Value
20 Lakhs
Estimated cost
Bid Submission
19 Oct 2026
9 days left
EMD
40000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sirsa → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maintenance Of Fire Detection & Fire Fighting System Along With Periodic Maintenance And Repairs Of Various Lifts Under Af Stn Sirsa
BOQ
| Sl. No. | Item Description |
| 1 | SCHEDULE 'A' PART-I : REPAIRS TO FIRE ALARM & FIRE FIGHTING SYSTEM |
| 2 | M&L for periodic inspection (once in a Qtr) for proper upkeepment and functioning of the \\"Fire Alarm & Fire Detection System\\" installed in buildings at WSA Including checking for all parameters and carrying out petty repairs, identifying and rectifying the faults including replacement of defective parts & accessories and testing the whole system complete all as specified and as directed comprising of the following :-(a) Fire Alarm Control Panel Four loop - 01 No. (b) Fire Alarm Control Panel Two loop - 05 Nos. (c) Smoke Detectors - 58 Nos. (d) Heat Detectors - 58 No.(e) Manual Call Point - 14 No. (f) Control Module - 59 No. (g) Fault/ Short Circuit Isolator - 05 No. (h) Remote Response Indicator - 116 No. (j) PVC Conduit Pipe 25mm - 850 RM (k) Copper Flexible Wire - 1660 RM |
| 3 | M&L for periodic inspection (once in a Qtr) for proper upkeepment and functioning of the \\"Fire Alarm & Fire Detection System\\" installed in ATC Building Including checking for all parameters and carrying out petty repairs, identifying and rectifying the faults including replacement of defective parts & accessories and testing the whole system complete all as specified and as directed comprising of the following :-(a) Fire Alarm Control Panel Four loop - 01 No. (b) Fire Alarm Control Panel Two loop - 05 No. (c) Smoke Detectors - 58 No. (d) Heat Detectors - 58 No.(e) Manual Call Point - 14 No. (f) Control Module - 59 No. (g) Fault/ Short Circuit Isolator - 05 No. (h) Remote Response Indicator - 116 No(j) PVC Conduit Pipe 25mm - 850 RM (k) Copper Flexible wire - 1660 RM |
| 4 | M&L for periodic inspection (once in a Qtr) for proper upkeepment and functioning of the \\"Fire Alarm & Fire Detection System\\" installed in SRE Building & PAR Building including checking for all parameters and carrying out petty repairs, identifying and rectifying the faults incl replacement of defective parts & accessories and testing the whole system complete all as specified and as directed comprising of the following :-(a) Fire Alarm Control Panel Four loop - 01 No. (b) Fire Alarm Control Panel One/Two loop - 04 No. (c) Multi sensor detector Smoke & Heat with base - 35 No. (d) Fire alarm sounder/siren electronic type 65 DB to 120 DB - 02 No (e) Manual Call Point -10 No. (f) Addressable Control Module - 06 No. (g) Fault/ Short Circuit Isolator - 04 No. (h) Remote Response Indicator - 27 No(j) PVC Conduit Pipe 25mm - 516 RM (k) Copper conductor cable - 1940 RMNOTE: Work in all the above buildings shall be measured as a single unit. |
| 5 | M&L for periodic inspection (once in a Qtr) for proper upkeepment and functioning of the \\"Fire Alarm & Fire Detection System\\" installed in AUDITORIUM Including checking for all parameters and carrying out petty repairs, identifying and rectifying the faults including replacement of defective parts & accessories and testing the whole system complete all as specified and as directed comprising of the following :-(a) Fire Alarm Control Panel Four loop (Make:Notifier) - 01 No (b) Network repeater panel - 01 No. (c) Analogue addressable multi sensor detector - 210 No. (d) Addressable heat detector -04 No(e) Analogue addressable control module -12 No (f) Fault isolator module - 10 No. (g) Remote response indicator -04 No (h) Addressable zone interface module -04 No (j) Hooter / strobe rated 100 db- 12 No . (k) Manual call point- 12 (l) PVC Conduit Pipe 25mm - 380 RM (m) Beam detector - 04 Nos(m) Copper conductor cable 1.5sqmm- 1050 RM |
| 6 | M&L for periodic inspection (once in a Qtr) for proper upkeepment and functioning of the \\"Fire Alarm & Fire Detection System\\" installed in TECH FLT HANGAR & SQN HANGAR Including checking for all parameters and carrying out petty repairs, identifying and rectifying the faults including replacement of defective parts & accessories and testing the whole system complete all as specified & as directed comprising of the following :-(a) Fire Alarm Control Panel Four loop (Make: Notifier) - 02 No (b) Network repeater panel 4 inch 640 character - 04 No. (c) Analogue addressable multi sensor detector with hard addressing feature - 766 Nos(d) Addressable fixed temperature 57 degree thermistor type heat detector - 06 No. (e) Analogue addressable mini monitor module -32 No (f) Fault isolator module - 48 No. (g) Analogue Addressable with hand addressing - 55 No. (h) Analogue addressable monitor module - 20 No (j) Analogue addressable control relay module - 20 No. (k) Hooter / strobe rated 82 Db- 59 No. (l) Dual action addressable manual pull station with address switch - 59 No. (m) Response indicator for detector - 252 No (n) Intelligent electronically addressable duct detector (high velocity- 10 Nos(o) Wall / ceiling mounted type Fire/flame detector - 16 Nos (p) PVC Conduit Pipe 25mm - 7260 RM (q) Copper conductor cable 1.5sqmm- 7000 RMNOTE: Work in both the hangars shall be measured as a single unit. |
| 7 | M&L for periodic inspection (once in a Qtr) for proper upkeepment and functioning of the \\"Fire Alarm & Fire Detection System\\" installed in IGLOO - 05, 06 & 07 Including checking for all parameters and carrying out petty repairs, identifying and rectifying the faults including replacement of defective parts & accessories and testing the whole system complete all as specified & as directed comprising of the following :-(a) Fire Alarm Control Panel Four loop (Make: Honeywell) - 02 No (b) Network repeater panel 4 inch 640 character - 04 No. (c) Analogue addressable multi sensor detector with hard addressing feature - 398 Nos(d) Addressable fixed temperature 57 degree thermistor type heat detector - 30 No. (e) Analogue addressable mini monitor module - 40 No (f) Fault isolator module - 80 No. (g) Analogue Addressable with hand addressing - 50 No. (h) Analogue addressable monitor module - 20 No (j) Analogue addressable control relay module - 20 No. (k) Hooter / strobe rated 82 Db- 59 No. (l) Dual action addressable manual pull station with address switch - 59 No. (m) Response indicator for detector - 252 No (n) Intelligent electronically addressable duct detector (high velocity- 10 Nos(o) Wall / ceiling mounted type Fire/flame detector - 30 Nos (p) PVC Conduit Pipe 25mm - 7260 RM (q) Copper conductor cable 1.5sqmm- 10000 RMNOTE: Work in all 03 Igloos shall be measured as a single unit. Please Enable Macros to View BoQ information |
| 8 | M&L for periodic inspection (once in a Qtr) for proper upkeepment and functioning of the \\"Fire Alarm & Fire Detection System\\" installed in IGLOO - 05, 06 & 07 Including checking for all parameters and carrying out petty repairs, identifying and rectifying the faults including replacement of defective parts & accessories and testing the whole system complete all as specified & as directed comprising of the following :-(a) Fire Alarm Control Panel Four loop (Make: Honeywell) - 02 No (b) Network repeater panel 4 inch 640 character - 04 No. (c) Analogue addressable multi sensor detector with hard addressing feature - 398 Nos(d) Addressable fixed temperature 57 degree thermistor type heat detector - 30 No. (e) Analogue addressable mini monitor module - 40 No (f) Fault isolator module - 80 No. (g) Analogue Addressable with hand addressing - 50 No. (h) Analogue addressable monitor module - 20 No (j) Analogue addressable control relay module - 20 No. (k) Hooter / strobe rated 82 Db- 59 No. (l) Dual action addressable manual pull station with address switch - 59 No. (m) Response indicator for detector - 252 No (n) Intelligent electronically addressable duct detector (high velocity- 10 Nos(o) Wall / ceiling mounted type Fire/flame detector - 30 Nos (p) PVC Conduit Pipe 25mm - 7260 RM (q) Copper conductor cable 1.5sqmm- 10000 RMNOTE: Work in all 03 Igloos shall be measured as a single unit. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysOct 20, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender