Defence Statutory Bodies & Commissions/Committees Closing in 9 days TDR #57890233

Tender For Repair/Maintenance Of Fire Detection & Fire Fighting System Along With Periodic Maintenance And Repairs Of Various Lifts Under Af Stn Sirsa

Issued by Statutory Bodies & Commissions/Committees · Sirsa, Haryana
Tender Value
20 Lakhs
Estimated cost
Bid Submission
19 Oct 2026
9 days left
EMD
40000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sirsa → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maintenance Of Fire Detection & Fire Fighting System Along With Periodic Maintenance And Repairs Of Various Lifts Under Af Stn Sirsa

BOQ

Name of Work:- REPAIR/MAINTENANCE OF FIRE DETECTION & FIRE FIGHTING SYSTEM ALONG WITH PERIODIC MAINTENANCE AND REPAIRS OF VARIOUS LIFTS UNDER AF STN SIRSA
Sl. No. Item Description
1SCHEDULE 'A' PART-I : REPAIRS TO FIRE ALARM & FIRE FIGHTING SYSTEM
2M&L for periodic inspection (once in a Qtr) for proper upkeepment and functioning of the \\"Fire Alarm & Fire Detection System\\" installed in buildings at WSA Including checking for all parameters and carrying out petty repairs, identifying and rectifying the faults including replacement of defective parts & accessories and testing the whole system complete all as specified and as directed comprising of the following :-(a) Fire Alarm Control Panel Four loop - 01 No. (b) Fire Alarm Control Panel Two loop - 05 Nos. (c) Smoke Detectors - 58 Nos. (d) Heat Detectors - 58 No.(e) Manual Call Point - 14 No. (f) Control Module - 59 No. (g) Fault/ Short Circuit Isolator - 05 No. (h) Remote Response Indicator - 116 No. (j) PVC Conduit Pipe 25mm - 850 RM (k) Copper Flexible Wire - 1660 RM
3M&L for periodic inspection (once in a Qtr) for proper upkeepment and functioning of the \\"Fire Alarm & Fire Detection System\\" installed in ATC Building Including checking for all parameters and carrying out petty repairs, identifying and rectifying the faults including replacement of defective parts & accessories and testing the whole system complete all as specified and as directed comprising of the following :-(a) Fire Alarm Control Panel Four loop - 01 No. (b) Fire Alarm Control Panel Two loop - 05 No. (c) Smoke Detectors - 58 No. (d) Heat Detectors - 58 No.(e) Manual Call Point - 14 No. (f) Control Module - 59 No. (g) Fault/ Short Circuit Isolator - 05 No. (h) Remote Response Indicator - 116 No(j) PVC Conduit Pipe 25mm - 850 RM (k) Copper Flexible wire - 1660 RM
4M&L for periodic inspection (once in a Qtr) for proper upkeepment and functioning of the \\"Fire Alarm & Fire Detection System\\" installed in SRE Building & PAR Building including checking for all parameters and carrying out petty repairs, identifying and rectifying the faults incl replacement of defective parts & accessories and testing the whole system complete all as specified and as directed comprising of the following :-(a) Fire Alarm Control Panel Four loop - 01 No. (b) Fire Alarm Control Panel One/Two loop - 04 No. (c) Multi sensor detector Smoke & Heat with base - 35 No. (d) Fire alarm sounder/siren electronic type 65 DB to 120 DB - 02 No (e) Manual Call Point -10 No. (f) Addressable Control Module - 06 No. (g) Fault/ Short Circuit Isolator - 04 No. (h) Remote Response Indicator - 27 No(j) PVC Conduit Pipe 25mm - 516 RM (k) Copper conductor cable - 1940 RMNOTE: Work in all the above buildings shall be measured as a single unit.
5M&L for periodic inspection (once in a Qtr) for proper upkeepment and functioning of the \\"Fire Alarm & Fire Detection System\\" installed in AUDITORIUM Including checking for all parameters and carrying out petty repairs, identifying and rectifying the faults including replacement of defective parts & accessories and testing the whole system complete all as specified and as directed comprising of the following :-(a) Fire Alarm Control Panel Four loop (Make:Notifier) - 01 No (b) Network repeater panel - 01 No. (c) Analogue addressable multi sensor detector - 210 No. (d) Addressable heat detector -04 No(e) Analogue addressable control module -12 No (f) Fault isolator module - 10 No. (g) Remote response indicator -04 No (h) Addressable zone interface module -04 No (j) Hooter / strobe rated 100 db- 12 No . (k) Manual call point- 12 (l) PVC Conduit Pipe 25mm - 380 RM (m) Beam detector - 04 Nos(m) Copper conductor cable 1.5sqmm- 1050 RM
6M&L for periodic inspection (once in a Qtr) for proper upkeepment and functioning of the \\"Fire Alarm & Fire Detection System\\" installed in TECH FLT HANGAR & SQN HANGAR Including checking for all parameters and carrying out petty repairs, identifying and rectifying the faults including replacement of defective parts & accessories and testing the whole system complete all as specified & as directed comprising of the following :-(a) Fire Alarm Control Panel Four loop (Make: Notifier) - 02 No (b) Network repeater panel 4 inch 640 character - 04 No. (c) Analogue addressable multi sensor detector with hard addressing feature - 766 Nos(d) Addressable fixed temperature 57 degree thermistor type heat detector - 06 No. (e) Analogue addressable mini monitor module -32 No (f) Fault isolator module - 48 No. (g) Analogue Addressable with hand addressing - 55 No. (h) Analogue addressable monitor module - 20 No (j) Analogue addressable control relay module - 20 No. (k) Hooter / strobe rated 82 Db- 59 No. (l) Dual action addressable manual pull station with address switch - 59 No. (m) Response indicator for detector - 252 No (n) Intelligent electronically addressable duct detector (high velocity- 10 Nos(o) Wall / ceiling mounted type Fire/flame detector - 16 Nos (p) PVC Conduit Pipe 25mm - 7260 RM (q) Copper conductor cable 1.5sqmm- 7000 RMNOTE: Work in both the hangars shall be measured as a single unit.
7M&L for periodic inspection (once in a Qtr) for proper upkeepment and functioning of the \\"Fire Alarm & Fire Detection System\\" installed in IGLOO - 05, 06 & 07 Including checking for all parameters and carrying out petty repairs, identifying and rectifying the faults including replacement of defective parts & accessories and testing the whole system complete all as specified & as directed comprising of the following :-(a) Fire Alarm Control Panel Four loop (Make: Honeywell) - 02 No (b) Network repeater panel 4 inch 640 character - 04 No. (c) Analogue addressable multi sensor detector with hard addressing feature - 398 Nos(d) Addressable fixed temperature 57 degree thermistor type heat detector - 30 No. (e) Analogue addressable mini monitor module - 40 No (f) Fault isolator module - 80 No. (g) Analogue Addressable with hand addressing - 50 No. (h) Analogue addressable monitor module - 20 No (j) Analogue addressable control relay module - 20 No. (k) Hooter / strobe rated 82 Db- 59 No. (l) Dual action addressable manual pull station with address switch - 59 No. (m) Response indicator for detector - 252 No (n) Intelligent electronically addressable duct detector (high velocity- 10 Nos(o) Wall / ceiling mounted type Fire/flame detector - 30 Nos (p) PVC Conduit Pipe 25mm - 7260 RM (q) Copper conductor cable 1.5sqmm- 10000 RMNOTE: Work in all 03 Igloos shall be measured as a single unit. Please Enable Macros to View BoQ information
8M&L for periodic inspection (once in a Qtr) for proper upkeepment and functioning of the \\"Fire Alarm & Fire Detection System\\" installed in IGLOO - 05, 06 & 07 Including checking for all parameters and carrying out petty repairs, identifying and rectifying the faults including replacement of defective parts & accessories and testing the whole system complete all as specified & as directed comprising of the following :-(a) Fire Alarm Control Panel Four loop (Make: Honeywell) - 02 No (b) Network repeater panel 4 inch 640 character - 04 No. (c) Analogue addressable multi sensor detector with hard addressing feature - 398 Nos(d) Addressable fixed temperature 57 degree thermistor type heat detector - 30 No. (e) Analogue addressable mini monitor module - 40 No (f) Fault isolator module - 80 No. (g) Analogue Addressable with hand addressing - 50 No. (h) Analogue addressable monitor module - 20 No (j) Analogue addressable control relay module - 20 No. (k) Hooter / strobe rated 82 Db- 59 No. (l) Dual action addressable manual pull station with address switch - 59 No. (m) Response indicator for detector - 252 No (n) Intelligent electronically addressable duct detector (high velocity- 10 Nos(o) Wall / ceiling mounted type Fire/flame detector - 30 Nos (p) PVC Conduit Pipe 25mm - 7260 RM (q) Copper conductor cable 1.5sqmm- 10000 RMNOTE: Work in all 03 Igloos shall be measured as a single unit. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57890233
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 20 Lakhs
LAST DATE 19-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maintenance Of Fire Detection & Fire Fighting System Along With Periodic Maintenance And Repairs Of Various Lifts Under Af Stn Sirsa
Basic Detail
Tender No GE/SRA/T-49/2026-27
Bidding Type Tender
Location
City Sirsa
State Haryana
Key Dates
Publish Date 06 Oct 2026
Submission Date 19 Oct 2026
Open Date 20 Oct 2026
Finance
Tender Value 20 Lakhs
Tender Fee 500
EMD 40000
Exemption Available
Document List
4be8d450-2db3-4b8c-ac9d-8b1c8440eff6.html
BOQ_888733.xls
CREDIT.pdf
GENINSTRCTIONT.pdf
Tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Oct 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

4be8d450-2db3-4b8c-ac9d-8b1c8440eff6.html

xls

BOQ_888733.xls

pdf

CREDIT.pdf

pdf

GENINSTRCTIONT.pdf

pdf

Tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders