Water Resources and Irrigation Government Departments Closing in 2 days TDR #57890086

Tender For annual repair & maintenance of Lwss Thural Bharanta (Batan Source) In Tehsil Pal Ur Distt. Kangra (Hp) (Sh: - Replacement Of Pumping Machinery Lwss Thural Bharanta (Batan Surce) Set No.2)

Issued by Government Departments · Kangra, Himachal Pradesh
Tender Value
3.75 Lakhs
Estimated cost
Bid Submission
17 Oct 2026
2 days left
EMD
7500
Bank guarantee accepted
Document Fee
350
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kangra → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for annual repair & maintenance of Lwss Thural Bharanta (Batan Source) In Tehsil Pal Ur Distt. Kangra (Hp) (Sh: - Replacement Of Pumping Machinery Lwss Thural Bharanta (Batan Surce) Set No.2)

BOQ

Name of Work:- A/R & M/O LWSS Thural Bharanta (Batan Source) in Tehsil Pal ur Distt. Kangra (HP) (SH: - Replacement of Pumping machinery LWSS Thural Bharanta (Batan Surce) Set No.2)
Sl. No. Item Description
1Surface preparation, Treating the cracks, cleaning of survace with the help of various equipment wire brush etc. and surface to bemade dirt,oil and foreign particles free. Once the cleaning is done the site area will be washed with watre to do away with micro fine particles from the water proofing area. All the area where water proofing job will be taken should be closed for normal foot trafic till .Repair of surface with polymer modified mortar (cement/ water/ Fosroc Nitobond SBRATEX) all the cracks to be repaired and filled with polymer modified mortar. Any loose area present on the surface will also be required with PMM. Repair area will be required to care for one day before application of water proofing coating on the surface. Any pipe penetrations in the surface will berequired and sealed with PMM. complete in all respect as per direction of Engineer in charge with in all leads and lifts.
2Location of site :- The site is located at a distance of 55 KMs from Palampur maranda railway station on thural Sujanpur road site is located at 105 km from Pathankot & 750 mtrs by heads load.
3The altitude of place in which 1000 Metres above MSL.
4the motor is intended
5Type of current :- AC three phase supply with freqency of 50
6cycles per second.
7Rated Voltage :- 415 V(+/- 10%
8Type of Water (Raw/Treated). Clear water
9Charactrstics of water :- (a) Temperature 20 0C b) Turbidity PPM
10c) Hardness 260 Mg./ Litres (as Ca Co3 )
11d)PH f) others --------
12e) Total solids. Mg / lit.
13Depth of well :- Mtrs.
14L.W.L in well/ Sump well:- mtrs.
15Suction Head mtrs
16centre line level of Pump 550.13 mtrs
17Discharge level of highest point 715.13 mtrs.
18No. of pump required :- 1Nos Pump
19Capacity :- 4.90 LPS for each pump
20Static head in mtrs. 165.00 meters
21Total head in metres 180.15 Meters
22Length of Rising main :- 1740 meters
23Dia of Rising main :- 65 mm dia
24No of pumping Hrs. per day:- 16 Hrs.
25Limits of pump operation :- (-) 25 to (+)10 to total head.
26HP of motor Drive unit :- Required BHP of pump at ( +) 10% & (-)25% of total head or BHP with following margins/multiplying factor at dutypoint,whichever is higher
27Up to 2 HP =1.50 d) 10 to 20HP =1.20
282 to 2 HP =1.40 d) 20 to 100HP =1.15
295 to 10 HP =1.30 e) above 100 HP=1.10
30RPM of Pumping Sets:- 2900 _ rpm ( to be quoted by tenderer )
31Test Run :- 8 hrs. continueously for 7 days.
32NPSH available 8.43 mtrs
33Supply of Star delta of L& P & BCH. reputed make of havey duty application rating 15 to 500 amper constant current /torque controll starting from comprehensive motor complete in all respect as per direction of Engineer in charge with in all leads and lifts.
34Providing M.S. sheet 16 SWG fabricated floor mounted closed (Almirah type) switch board including angle iron post of suitable height & size ISA 65x65x6mm all internal electric connections. The drawing of pannel board shall be subject to approval of Engineer-in-Charge
35Note;- The drawing of panel board shall be subject to appoved of Engineer in charge .
36Ammeter AC supply, 100 mm square type auto electric of AE/ IMP/Havells/ L & T / BCH make of suitable range for above motor with selector switches conforming to BIS-1248-1983 latest with upto date amendments.
37Voltmeter AC supply, 100 mm square type auto electric of AE/ IMP/Havells make of suitable range for above motor with selector switches conforming to BIS-8044-1978 latest with upto date amendments.
38ICTP switches with HRC fuses of Kilburn/L&T/Seimens/standard /Havells/ BCH/ . make and having capacity 30% extra of operational rating of motor as per BIS 4064-1978 with up to date ammendments immediately after the power meter of HPSEB.
39MCB of suitable capacity of Havells/standard/MEI/GEC/Kilburn/ BCH. make on incoming feeder for pumping sets conforming to BIS 2516-19855 (latest edition) with neutralinked linked under voltage release.
403 phase indicator lamps complete with toggle switches for individual motors conforming ti BIS 3452 part I & II latest with up to date amendments
41Earth leakage circuit breaker of(ELCB/ GLCR )of Standard Havells/ BCH. make as per BIS 2516-1977 with upto date ammendments & of suitable range with which should have control box,, operating handle and trip / reset bush button on / off indicator, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with megnet thurmal release with metallic type etc., .It should also be fitted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side .
42Hour run meter of reputed/approved make of four digit capacity conforming to BIS -722 (latest edition)
43Change over switch of reputed make & suitable capacity
44Single phase Preventeor of reputed make & suitable capacity
45Three phases voltage monitor relay with all protection 7 usual indication with electrical siem against single, phasing low voltage high voltage & overloading & phase voltage difference as pe BIS 3842 (Latest edition) of suitable capacity
46Supply of Kirloskar/Kilburn /IVC /Fouress /Gled/BHEL/Leader/kartar make of cast steel double flanged sluice valve (to be provided on delivery side of size one dia Higher to the delivery size of pump and capable of with standing nominal seat pressure of 21 kg/cm2 of class ASA-150 confirming to BIS 1414(API 600) Note:- The CI sluice vlave shall confirm to BIS 780-1984 for 50 to 300 mm dia & BIS 2906-1984 for 350 to 1200 mm dia (latest adition) however if seat pressure exceeds the limits prescribed in above mentioned BIS than it shall be of cast steel conforming to class ASA-150 for seat pressure upto 21kg/cm2 or class ASA-300 for seatpressure 52Kg/Cm2 as BS1414(API 600) 65 mm dia
47Supply of Kirloskar/ kilburn /IVC/Fouress/Gled/BHED/Leader/kartar of suitabe size cast steel double flanged swing check type reflux valve having bye-pass arangement (to be provided on delivery side of size one size Higher than pump size to delivery of pump and capable of with standing nominal seat pressure of 21 kg/cm2 of class ASA-150 as per BS-1868-API(600) 65 mm dia
48Providing and laying PVC insulated jointless, flat water proof copper cable of Siemens/ Finolex/Grandlay/Gloster make confirming to BIS: 1554 (Part-I)-1988 or latest with upto date ammendments of suitable size for the pump sets offered (One cable carrying all three phases) including all other electrical equipment/accessories such as thimble,flexible pipe solder,nuts & bolts cable gland etc. laid in pipe or trenches under floor. The type size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities, it shall have to be replaced by the tenderer free of cost.
49(a) On supply side of 3½ core (from HPSEB Meter to switch & starter )=5 Mtrs of size 6 mm2
50(b) On motor side of 3 core (From switch & starter to motor ) =10 mtrs of size 10 mm2
51Providing and laying double loop earthing and copper plate 600x600x3mm thick electrode complete with material such as charcoal & common salt, GI pipes, thimbles, nuts & bolts, digging of pits GI Wire & 25x3mm copper strips as per BIS: 3043-1987 latest with upto date mmendments for above motors & other electrical equipment. NOTE:-- the strip size shall be 20x3 upto 18.5 KW, 25x3 for 18.5 to 37KW 25x5 for 37 to 55KW & 32x5 beyond 55KW.
52Supply & 100 mm dia square dial pressure gauge o suitable range of Fiebeg/ Bourden/ PREGA/ Precision / PREGA make complete with all accessories such as stop cock, copper tubing etc. confiriming BIS 3624-1987 latest with upto date ammendments.
53Providing and laying G.I./ MSERW pipes of suitable size for suction ,delivery and commonheader considering site requirements & NPSH required/available.The pipe sizes for suction and delivery shall as per the requirements of offered pump (to be given by the tenderer)and commonheader shall have area to equal to two times the area of delivery pipe of pump or equal to dia of Rising main including tapers,flanges,bends,rubber gasket,3mm thick nuts & bolt and speical upto 5 meters away from the outer wall of pump house as per layout drawing approved by Engineer-in-charge..The pipes material shall conform to relevent BIS codes and capable ofof with standing FTP equal to 1.5 times the operating pressure and arrangement shall comprise of :
54a) Suction Pipe…80………..mm dia 2x5mtrs length
55b) Delivery pipe …65………….mm dia 2x2 mts. length
56c ) Common header pipe 65 mm dia 5 mtrs. Length
57Errection of all equipments from S.No. 1 to 4,6 & 8 i/c cost of tees,bends,tapers & any other fitting required complete in all respect as per direction of Engineer in charge with in all leads and lifts. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57890086
AUTHORITY Government Departments
TENDER VALUE 3.75 Lakhs
LAST DATE 17-10-2026
Authority
Authority Name Irrigation And Public Health Department
Work Description Tender for annual repair & maintenance of Lwss Thural Bharanta (Batan Source) In Tehsil Pal Ur Distt. Kangra (Hp) (Sh: - Replacement Of Pumping Machinery Lwss Thural Bharanta (Batan Surce) Set No.2)
Basic Detail
Tender No EE/JSVD/THL/2026-27-7379-7415 Dt. 06.10.2026
Bidding Type Tender
Location
City Kangra
State Himachal Pradesh
Key Dates
Publish Date 06 Oct 2026
Submission Date 17 Oct 2026
Open Date 19 Oct 2026
Finance
Tender Value 3.75 Lakhs
Tender Fee 350
EMD 7500
Exemption Not Available
Document List
b388539f-5924-4235-855d-5a202f43e26a.html
BOQ_215983.xls
Form6.pdf
Form8.pdf
Tendernotice_1.pdf
Termsandconditions.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Oct 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

b388539f-5924-4235-855d-5a202f43e26a.html

xls

BOQ_215983.xls

pdf

Form6.pdf

pdf

Form8.pdf

pdf

Tendernotice_1.pdf

pdf

Termsandconditions.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender