Tender For Rkvy Project-Construction Of Physical Barriers For Mitigating Man Animal Conflict By Installation Of Conventional (5 Line) Cum Hanging Solar Fencing (1.0 Km) At Kandakkayam To Puzhippalappdi Areas In Murinjapuzha Forest Station Under Erume
Tender Overview
Project Description
Tender for Rkvy Project-Construction Of Physical Barriers For Mitigating Man Animal Conflict By Installation Of Conventional (5 Line) Cum Hanging Solar Fencing (1.0 Km) At Kandakkayam To Puzhippalappdi Areas In Murinjapuzha Forest Station Under Erumely Range During 2026-27
BOQ
| Sl. No. | Item Description |
| 1 | Civil works |
| 2 | Cutting branches of trees overhanging above any structures of girth between 60cm to 90cm including stacking of serviceable materials and disposal of unserviceable material, cost of labour, hire charges of rope and pully etc without making any damages to nearby structures etc complete |
| 3 | Cutting branches of trees overhanging above any structures of girth beyond 120cm including stacking of serviceable materials and disposal of unserviceable material, cost of labour, hire charges of rope and pully etc without making any damages to nearby structures etc complete. |
| 4 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 5 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 6 | DOWEL BARS - Supplying and providing MS dowel bars of size 16 mm dia of 0.60 m long (30 cm in rock and 30cm in concrete) including drilling holes of 20mm dia to a depth of 0.30m in rock and filling the gap with cement grout(0.075kg/each) etc |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement: 2 coarse sand (zone-III)derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 8 | Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 9 | providing and fixing reel insulator made up of virgin durable quality, sturdiness, unit weight 18g or nearest ,withstanding voltage 15kV 15 kV |
| 10 | Supplying and fixing permanent wire Tightner corrosion resistant pressure diecasting process, using LM6 grade aluminum alloy. it is used to tighten fence wire and maintain adequate tension. etc. complete as per the direction of engineer in charge |
| 11 | Supply and fixing of Super Strain insulator (Poly propylene, 400 N, 15 KV Guy type) |
| 12 | providing warning signs poly-rthlene plastic with statutory colour and signs |
| 13 | providing and fixing of bullets(connectors)-copper material or aluminium or stainless steel material having an inner core hole size of 2.5mm dia,2cm length including all cost |
| 14 | Providing and laying of fence wire SWG 12 ACSR high tension hot dipped, size 2.59 mm, standard IS 398-part2 /1996, breakage capacity 600kg, purity of zinc 99.95% wof coating 230g/m2, GI systematic make etc. complete as per direction of engineer in charge.(Quality of ACSR wire should be assured with test result and certificates) |
| 15 | Providing and fixing 2.85 Mtr, 2 mm Dia SS rope (304 Grade) for vertical hanging lines in solar fencing, including all necessary accessories,cutting, fixing, labour, tools and tackles approved make etc. complete as per direction of engineer in charge. |
| 16 | Supplying and fixing Gate Handle with spring including all labour charges etc |
| 17 | Electrical works |
| 18 | providing and fixing of lightning diverter must be capable of diverting stray lightening. The diverter assembly must be adjustable for spark gaps. : Adequate earthing to be provided |
| 19 | Supply and installation of Energizer with following specification 12 V Energizer of Make: dual zone energizer with 2 years warranty or equivalent,must confirm to IEC standard 60335.2.76 or IS 302-3-76 (1999) and all national and international standards of safety,switch to high and low power setting, solar panel option to recharge 12volt battery,Should possess the following output characters, Peak o/pvoltage not more than 10kv on 50Kload, o/o energy 3.5 J minimum pulse duration1.01-3.0m sec-,Pulse interval 1.1-1.4 sec, peak current 7.0-8.0 А |
| 20 | Supply of 12V 100AH Lithium ferrous phosphate battery with 5year warranty maintenance free with connecting wires etc. |
| 21 | Supply of equipment safety box for housing energizer, battery, charge control unit etc, body of which is made of 18-20 gauge metal plate, powder coated provided with stand of 1 meter height made of single leg of painted GI pipe size of 75 mm. |
| 22 | Supply and fixing of MPPT Charge controller 12/24V 50A having capacity of 900Wp solar to regulate the charging of the battery of approved brand (ASHAPOWER or Equivalent |
| 23 | providing and fixing 160 watts, mono crystalline solar panel 12 volts rating with minimum 10 years performance warranty against manufacturing defects. Make waree,adani or equivalent |
| 24 | Providing Digital volt meter must display fence voltage in kilowatt up to 9.9kvincluding all cost |
| 25 | supply of Tool Kit cutting pliers, crimping tool, multi meter, double ended spanner etc as equivalent |
| 26 | supply and drawing DC Solar cable 4 sq mm single run with UV protection of reputed brand connection etc as required |
| 27 | Providing and laying of Lead Out Cable must be double insulated withstanding 15KV voltage and inner core wire must be GI |
| 28 | supply and installing multi spike Lightning arrester Must be capable of diverting stray lightning in suitable height including GI pipe for fixing and concrete/equivalent for fixing on the ground |
| 29 | Earthing system Must contain earth mixture capable of retaining moisture and 8 mmdia stainless steel rod grade 304 or above non rusting quality of 4 feet long Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
TodayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender