Housing Urban and Rular Development Government Departments Closing in 16 days TDR #57889160

Tender For Repair & Maintenance Of Ac & Air Cooling In Govt Pt Jln Hospital At Nagaur

Issued by Government Departments · Nagaur, Rajasthan
Tender Value
5.57 Lakhs
Estimated cost
Bid Submission
04 Nov 2026
16 days left
EMD
11140
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nagaur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair & Maintenance Of Ac & Air Cooling In Govt Pt Jln Hospital At Nagaur

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 15-Oct-2026 Date Extended Date 04-Nov-2026

BOQ

Name of Work:- Repair & Maintenance of AC & Air Cooling in Govt Pt JLN Hospital at Nagaur
Sl. No. Item Description
1SITC of Monoblock closed coupled motor pump set with TEFC motor, motor should be IP55-F class and IE2 efficiency for monobloc, with carbon steel /SS-410 shaft, Mechanical seal, Single/Three phase Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively and Dynamically balanced rotating parts to ensure min. vibration etc. complete in all respect.
20.5 HP, 1-Ø, (8 - 26)Mtr, (50-10) LPM (SS Impellor & SS Body)
3Supply and Fixing of Desert Cooler having cooling capacity of 5000 cum/hr., approx. size of cooler is 28\\"x28\\"x38\\" and having tank of 9\\" height with 20\\" 1400 rpm heavy duty fan motor and required size of submersible pump and all other required accessories. Cooler should be made of 18 SWG GI sheet for tank and remaining cooler body should be of 20 SWG GI sheet, grill of size 22\\"x25\\" including required size angle iron stand duly painted with 2 coats of red oxide and one coat of enamel paint complete in all respect as required.
4Supply and fixing of ss-304 (18 guage ) made sump for 15000 to 30000 cfm double skin central evaporative cooling plant including the air cooling machine needs to be dismantal and reinstalled using a new sump with necessary arrengement for water pump, wet pads , 2 nos pre-filters,the end plates for pad & eliminator shall be in ss-304 constructed, include necessary hardware etc as required.
5Painting of desert cooler with two coats of rubber paint inside of water tank and two coat of synthetic enamelled paint on both side of cooler body, fan body, grills etc.after cleaning with sand paper, complete in all respect as required.
6Replacement of cooler pads (heavy) set of 3 no. of size 25\\" x 27\\"
7P & F Brass float valve of weighing approx. 250 gm, 8\\" long rod,PVC ball of 4\\" dia. For desert coler as required.
8P & F of submercible pump set suitable for 18/24 \\"Desert coolers.
9P & F cooler fan motor suitable for 20\\" desert cooler including making connection testing etc. as required.
10with copper winding Motor ISI Marked
11Supplying and charging of fresh refrigerant and testing of performance of air conditioner/ fridge/ water cooler of following capacity including capallary and strainer/ filter.
121.5 TR Window/ Split A.C.
13Supply, installation, testing and commissioning of interconnecting copper refrigerant piping of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified 'Class O' in Fire Propagation as per BS 476 Part 6 with 7 mil Glass Cloth and 3 coats of anti UV paint (on area which is exposed to weather) including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes.
1415.9 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick)
159.5 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick)
16Replacement of defective compressor by company repaired compressor as per OEM recommendations of following gadgets including testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
171.5 TR A.C.
183.0 TR A.C.
19Servicing of 1.0/1.5/2.0 TR capacity Split/ Window type air conditioner
20Supply & fixing of evaporative cooling Celdec pads of 200mm Thick made out from impregnated cellulose paper media of imported origin including fixing in Air washer complete in all respect.
21Providing and replacement of following ball bearing of air washer including removing the bearing and refixing the same at suitable location as required as per OEM recommendations. Replacement of material or components shall be use ae per guideline of OEM of original product. Allthe scrap material should be retained by the contractor.
22UC 207
23UC 211
24P & F 3 Speed rotary switch for Desert Cooler complete with testing etc as required.
25P & F ISI marked waterproof plywood 6.0 mm thick including cutting, hardwares etc. as required.
26Servicing and overhauling of 20\\" sweep desert cooler including oiling, greasing, painting of tank from inside with rubber paint after properly desmantling each assembly and refixing the same as required.
27Providing & Fixing of ISI marked (IS:1293) 6 amp unbreakable 3 pin plug top having lamp indicator with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal including making connection testing etc. as required.
28Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size.
2916.0 Sq. mm
304 core Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57889160
AUTHORITY Government Departments
TENDER VALUE 5.57 Lakhs
LAST DATE 04-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Repair & Maintenance Of Ac & Air Cooling In Govt Pt Jln Hospital At Nagaur
Basic Detail
Tender No NIT20 2026-27 EE PWD Elec Dn Ajmer
Bidding Type Tender
Location
City Nagaur
State Rajasthan
Key Dates
Publish Date 15 Oct 2026
Submission Date 04 Nov 2026
Open Date 04 Nov 2026
Finance
Tender Value 5.57 Lakhs
Tender Fee 500
EMD 11140
Exemption Available
Document List
24fd350e-7b49-4e86-88a0-3ba8108499c0.html
BOQ_1069702.xls
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf
Tendernotice_4.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 04, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 16 days
Nov 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Nov 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

24fd350e-7b49-4e86-88a0-3ba8108499c0.html

xls

BOQ_1069702.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

pdf

Tendernotice_4.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender