Tender For Special Repair Of Bldg No To-312 Of 14 Corps Zonal Wksp Under Age B/R-I Of Ge 865 Ews, Leh
Tender Value
13.39 Lakhs
Estimated cost
Bid Submission
27 Oct 2026
19 days left
EMD
26800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
leh → Ladakh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair Of Bldg No To-312 Of 14 Corps Zonal Wksp Under Age B/R-I Of Ge 865 Ews, Leh
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons laid bedded and pointed in any mortar etc, complete all as specified and directed. |
| 2 | M&L for 25 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in sub base of floor, complete all as specified and directed. |
| 3 | Screed or bedding layer of mortar 15 mm thick for laying floor finishes in cement ratio 1:4, complete all as specified and directed. |
| 4 | M&L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbbing and polishing complete all as specified and directed. |
| 5 | Dismantling wall and ceiling boards (Fiber, pulp, insulation, blankets) any thickness including covered fillets and supporting members complete all as specified and directed. |
| 6 | M&L for 2nd class soft wood clean sawn as in battens for grids of ceiling & lining fixed with nails exc 13 sqcm and n exc 25 sqcm in section including dsmantlng, complete all as specified and as directed. |
| 7 | M&L for covered fillets of standard hard board not less than 6mm thick and up to 40mm wide and fixing with screws including dismantlng, complete all as specified and as directed |
| 8 | M&L for 9mm thick prelaminated particle board medium interior grade, prelaminated one side with decorated choice lamination & other side balancing white lamination fixed with nails to timber frame work as in wall panelling, shelves/boarding complete all as specified and as directed. |
| 9 | S&F anodised aluminium snap grid frame work of size 605x605mm for false ceiling, complete all as specified and directed. |
| 10 | Non asbestos 8 mm fibre cement building boards fixed with or laid/inserted to timber /GI/Aluminium framewk with screws, complete all as specified and directed. |
| 11 | M&L Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of existing plain or corrugated sheet of any description complete all as specified and directed. |
| 12 | S&F Fibre glass reinforced translucent plain sheeting 2mm thick with two corrugations side lap fixed with coach screw and washer in roof ,wall etc complete all as specified and as directed including dismantling of existing plain or corrugated sheet any description complete all as specified and directed. |
| 13 | M&L Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of existing plain or corrugated sheet any description complete all as specified and directed. |
| 14 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 15 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240, complete all as specified and directed. |
| 16 | Preparation of newly or previously untreated steel surfaces, of any description, over 10 cm width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 17 | M & L for 75 mm PCC 1:2:4 type B-1 using 20mm graded aggregate as plinth protection finished even and smooth with out using extra cement, complete all as specified and directed. |
| 18 | M&L Forming Contraction (Dummy) joints 65 mm deep x 10mm wide, filled with sealing compound Grade 'A' in plinth protection, complete all as specified and directed. |
| 19 | Demolition of cement concrete (unreinforced) in ground floor and pavings n'exc 15cm thick below or above ground level complete all as specified and as directed. |
| 20 | M&L for Cement concrete type D-2,1:4:8 (40mm graded aggreate) 75 mm thick as in sub -floors ,sub- bases ,floors and pavings,etc, complete all as specified and directed. |
| 21 | M&L for Chequred cement concrete tiles 30cm X 30cm X 20mm thick, set ,pointed & jointed in neat cement slurry in floors polished with grey cement & pigments .Layed over 20mm thick cement screed base (1:6) , complete all as specified and directed. |
| 22 | Taking down carefully copper/aluminium point wiring (light, fan, socket and power point) complete fittings such as switches, ceiling rose, regulators, socket etc and removing material from site and making good disturbed surfaces of walls, floors/ceiling to match the existing surface all as spfd and directed. |
| 23 | Taking down of submain wiring surface of wall, floores / ceiling and match the existing complete all as specified and directed. |
| 24 | M&L for point wiring with copper conductor FRLS cable Multistrand, single core 1.5 Sqmm size for one light point or bell point /Exhaust fan Point controlled by one switch including one run of 1.5 Sqmm multistrand PVC copper conductor cable for earth continuity in and including PVC casing and capping of approved size and quality fixed on walls/ceiling including rectangular PVC board heavy duty type for mounting switches /sockets etc complete all as directed and specified. |
| 25 | All as per Ser item No 25 here-in-before but for one 5/6 Amp socket outlet points on same board controlled by one switch. |
| 26 | All as per Ser item No 25 here-in-before but for one 5/6 Amp socket outlet points on independent board controlled by one switch. |
| 27 | All as per item No 25 above but using 4.0 sqmm cable. |
| 28 | Lamp holder, PVC/ Polycarbonate type with back plate, straight/ angular suitable for batten fittings, complete all as specified and directed. |
| 29 | Switch piano flush button single pole 6 Amps 230 volts one way, complete all as specified and directed. |
| 30 | Socket out let two-in-one 5 pin 6 Amps flush type, 230 volts, complete all as specified and directed.. |
| 31 | Switch Socket combination 5 pin 6 Amps 230 volts, flush type universal, complete all as specified and directed. |
| 32 | Switch Socket combination 5 pin 6 Amps and 16Amps 230 volts, flush type universal, complete all as specified and directed. |
| 33 | Ceiling rose 3 terminal bakelite 65mm x50mm surface type, PVC/ Polycarbonate, isolated body, complete all as specified and directed. |
| 34 | Replacement of MCB DB, SPN, 8 way sheet metal enclosures double door 230 V AC, 50 Hz AC with IP 54 and IK 09 rating having fully insulated copper busbar of rating 200 Amps, insulated neutral bar, earth bar and cable ties for cable management including polyuthrene gasket complete complete in all respect flushed in wall including cutting chases on wall for taking out old unsv DB and fixing of new DB and making good disturbed surface of wall with cement mortar 1:4 and finishes to match exisiting surface, complete all as specified and directed. |
| 35 | Replacement of MCB DB, SPN, 4 way sheet metal enclosures double door 230 V AC, 50 Hz AC with IP 54 and IK 09 rating having fully insulated copper busbar of rating 200 Amps, insulated neutral bar, earth bar and cable ties for cable management including polyuthrene gasket complete complete in all respect flushed in wall including cutting chases on wall for taking out old unsv DB and fixing of new DB and making good disturbed surface of wall with cement mortar 1:4 and finishes to match exisiting surface, complete all as specified and directed. |
| 36 | MCB, SPN, AC, 240 volts \\"C\\" series capacity of 40-63 Amps, 10kA and making connections, complete all as specified & directed. |
| 37 | MCB, SP, AC, 240 volts \\"C\\" series capacity of 6-32 Amps, 10kA and making connections, complete all as specified & directed. |
| 38 | Supply and fix in replacement submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed as required in PVC casing Caping wire size 2x4.0 sq. mm + 1x4.0 sq. mm earth wire complete all as specified and directed. |
| 39 | Supply and Fixing only in Replacement LED light fitting 1X20 W, 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make-Havells / crompton / Bajaj |
| 40 | Supply and fixing in replacement of LED Lamps 12 watt complete testind and commissioning all are specifed and directed by engineer-in-charge |
| 41 | Supply, fixing, connecting and testing in replacement LED security light fitting 35 watt, 230 volt, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp and GI Bracket made out of 32mm dia medium grade pipe 1.2m length to bend to shape 120 degrees for fixing on pole and suitable for 70 Watt street light with 02 Nos clamps set of flat iron (40 x4mm) nuts, bolts and washers including painting with two coats of aluminim paint over a coat of primer complete with impact and corrossion resistant incl thermal management in multiple optics complete with IP65/66 protectionand making good disturbed surface of wall with cement mortar 1:4 and finishes to match exisiting surface, complete all as specified and directed. |
| 42 | Earthing complete in repair with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead GI wire 4mm dia by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvd iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of 2009.Note : RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover. |
| 43 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in hard/dense soil complete all as specified and directed. |
| 44 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 2 core complete all as specified and directed. |
| 45 | M&L for crushed stone sand cushioning to UG cable, provide with the layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable complete all as specified and directed. |
| 46 | Supply and laid Un-reinforced precast concrete cable cover class LV 1 flat size 250 mm x 150 mm x 40 mm complete all as specified and directed. |
| 47 | Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed. |
| 48 | Removing excavated material n.exc 50m and depositing where directed at a level exc. 1.5 cm above the starting point complete all as specified and directed. |
| 49 | Supply and fix GI Pipe Light grade with all connected accessories of sizes 40 mm dia complete all as specified and directed. |
| 50 | Deduct Schedule of Credit of Rs (-)35326.50 (Minus) as listed in Schedule 'A' (Contd). Contract Sum shall be arrived after deducting the credit amount.Note :- Tenderers will not quote against this item being a firm amount. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysNov 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 27 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender