Housing Urban and Rular Development Local Bodies Closing in 4 days TDR #57887011

Tender For Rewiring Of Old And Deteriorated Electrical Wiring In The Rooms Construction For Drivers, Police/Security Staff, Post Office, Toilets And Other Rooms Located In The Parking Area In Haryana Vidhan Sabha, Sector-1, Chandigarh. (Mtc Of electr

Issued by Local Bodies · Chandigarh, Chandigarh
Tender Value
3.41 Lakhs
Estimated cost
Bid Submission
13 Oct 2026
4 days left
EMD
6900
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Rewiring Of Old And Deteriorated Electrical Wiring In The Rooms Construction For Drivers, Police/Security Staff, Post Office, Toilets And Other Rooms Located In The Parking Area In Haryana Vidhan Sabha, Sector-1, Chandigarh. (Mtc Of electrical installation In Nrb At Chandigarh)

BOQ

Name of Work:- REWIRING OF OLD AND DETERIORATED ELECTRICAL WIRING IN THE ROOMS CONSTRUCTION FOR DRIVERS, POLICE/SECURITY STAFF, POST OFFICE, TOILETS AND OTHER ROOMS LOCATED IN THE PARKING AREA IN HARYANA VIDHAN SABHA, SECTOR-1, CHANDIGARH. (MTC OF EI IN NRB AT CHANDIGARH)
Sl. No. Item Description
1DSR item No.1.15 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
2Group C
3DSR item No 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor. Single core cable etc. as required.
4Group C
5DSR item No.1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
63 x 1.5 sq. mm
73 x 2.5 sq. mm
8DSR item No. 1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
95/6 A switch
103 pin 5/6 A socket outlet
11DSR item No. 1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
12DSR item No 1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.as required.
131 or 2 Module
144 Module
156 Module
168 Module
17DSR item no 2.5 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar,din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.
184 way (4 + 12), Double door
19DSR item No 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
20Single pole
21DSR item No 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
22DSR item No 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
23DSR item No 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
2425 mm
25DSR Item No 2.2 Supply and Erection of following rating MCCB 3 pole 415voltsof L&T/scheinder/ABB/Havels/Legrand make only with Thermal magnetic/microprocessor Release for overload & short circuit protection, with following breaking capacity (Ics=100%Icu) with positive Isolation. The MCCB should be True RMS Sensing with adjustable overload and short circuit protection. The MCCB is to be installed in existing Cubical Panel making connections etc as required. The MCCB should be confirming IS60947-2 Indian Standard and all type test certificate should be submitted of Govt. approved lab. The job include all petty material required to complete the job to the entire satisfaction of the E.I.C. of the work.
26MCCB 100 Amp 36 KA 4 pole
27DSR Item No 9.2 Brush Less DIrect Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class ofinsulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, ServiceValue (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req.
281400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum)
29DSR Item No 8.10 LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-I n-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90 C).Powder Coated CRCA Sheet Body (Thickness > 0.50 mm)
301.10.4 40 watt
31DSR item no 8.2 LED Down lighter (SMD Type) (System lumen efficacy ≥120 <135lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed /surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \\"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminum Body including trim.
3222 watt Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57887011
AUTHORITY Local Bodies
TENDER VALUE 3.41 Lakhs
LAST DATE 13-10-2026
Authority
Authority Name Chandigarh Administration Engineering Department
Work Description Tender for Rewiring Of Old And Deteriorated Electrical Wiring In The Rooms Construction For Drivers, Police/Security Staff, Post Office, Toilets And Other Rooms Located In The Parking Area In Haryana Vidhan Sabha, Sector-1, Chandigarh. (Mtc Of electrical installation In Nrb At Chandigarh)
Basic Detail
Tender No E3/47W/152
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 06 Oct 2026
Submission Date 13 Oct 2026
Open Date 13 Oct 2026
Finance
Tender Value 3.41 Lakhs
Tender Fee Ref. Documents
EMD 6900
Exemption Not Available
Document List
BOQ_117913.xls
d62c702e-b555-4516-8f66-7c6199db7fe5.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Oct 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓