Civil Aviation Boards / Undertakings / PSU Closing in 20 days TDR #57886838

Tender For Construction Of Link Taxi Track For Proposed New Fto At Kishangarh Airport. Sh-Electrical Work.

Issued by Boards / Undertakings / PSU · Ajmer, Rajasthan
Tender Value
1.02 Crore
Estimated cost
Bid Submission
27 Oct 2026
20 days left
EMD
2.05 Lakhs
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ajmer → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Link Taxi Track For Proposed New Fto At Kishangarh Airport. Sh-Electrical Work.

BOQ

Name of Work:- Construction of Link Taxi Track for proposed new FTO at Kishangarh Airport. SH-Electrical work.
Sl. No. Item Description
1Supply of Medium Intensity Elevated type omni directional LED Taxiway edge Light fitting (LED type) for aviation visual aids requirements complete with LEDs, optic lens, power converter, two pin secondary lead, central column assembly, breakable coupling, base plate, gaskets, bolts etc. and all other standard accessories required as per ICAO and conforming to technical specifications.
2Supply of omni directional Inset Type Taxi way Light Fitting complete with shallow base, matching body made of die cast aluminium, pre-focused LED lamp and driver units suitable to work on 15 w 6.6/6.6 amps Isolating transformer with all accessories confirming to ICAO requirement complete as required.
3Supply of following type Bi-directional inset type High intensity Runway Edge light fitting for aviation visual aids requirements complete with shallow base of side cable entry, matching body of the fitting complete with 2 x 105 Watts, 6.6 amps pre-focused reflector halogen lamp connected heat resistant accessories, prism assembly, optical assembly, 'O' ring seal, pressure relief test plug, hardware, Cover Gas Kit and all other standard accessories required as per ICAO and conforming to technical specifications.
4Clear/Yellow
5Supply, installation, testing and commissioning of FAA certified / compliant model, Elevated, Uni-directional, Yellow, suitable for ICAO all weather operation, LED Runway Guard lights complete with Two elevated LED light fittings, driver, site programmable flash control unit ( switching device), cable lead with plug, Lense, glass, optical assembly, seal, hardware and all standard accessories, ready for site installation along with breakable coupling and base plate as per site requirement etc. compatible to existing ALCMS conforming to latest ICAO / CAR requirement as per specifications complete as required.
6Supply of Single core, 06 Sqmm, 5 KV, XLPE insulated & PVC seathed stranded copper conductor, antitermite & antirodent,Airport lighting cable confirming to IS 7098 (Part-II) with up to date ammendement and as per technical specification specified in tender documents.
7Supply of Single core, 16 Sqmm, 5 KV, XLPE insulated & PVC seathed stranded copper conductor, antitermite & antirodent,Airport lighting cable confirming to IS 7098 (Part-II) with up to date ammendement and as per technical specification specified in tender documents.
8Supply of 2 core 4 sqmm 600 V grade, copper conductor, EPR insulated, PCP sheathed, underground secondary cable complete as specified complete as required and conforming to technical specifications.
9Supply of following type, 5 KV grade, 50 Hz, series Isolating Transformer encapsulated in polyester resin, finally moulded in neoprene type rubber with primary and secondary connectors etc and all other standard accessories required as per ICAO and conforming to technical specifications.
1015 W, 6.6/6.6 Amps.
1145 W, 6.6/6.6 Amps.
12100 W, 6.6/6.6 Amps.
13200 W, 6.6/6.6 Amps.
14Supply of 5 KV grade plug & receptacle (Essna Connector) of type I class B connector & suitable for field attachment with 5 KV grade PVC insulated and PVC sheathed single core 6 sqmm copper conductor cable as etc complete as required and conforming to technical specifications.
15Supply of 5 KV grade plug & receptacle (Essna Connector) of type I class B connector & suitable for field attachment with 5 KV grade PVC insulated and PVC sheathed single core 16 sqmm copper conductor cable as etc complete as required and conforming to technical specifications.
16Supply of 1.1 KV grade plug & receptacle (Essena Connector) of type II class B connector & suitable for field attachment with 1.1 KV grade PVC insulated and PVC sheathed 2 core 4 sqmm copper conductor cable etc complete as required and conforming to technical specifications.
17Supply, installation, testing and commissioning of 4.0 KW Indoor type air cooled constant current regulator of microprocessor controlled, thyristor type suitable for operation on 230 Volts + 10%, 50 Hz input AC supply with 5 steps variation of current output, suitable for local and remote control operation with suitable control supply and able to communicate with PC or PLC controlled system, with output current indicated on multifunction digital display, overcurrent, over voltage, open circuit and earth fault protection and earthleakage meter, positive back indication equipments, hours run counter, complete as required, confirming to ICAO requirements and as per technical specifications.
18Design, Manufacturing, Supply, installation, connection, testing and commissioning of illuminated taxiway/ runway guidance signages of various sizes made of anodized 2 mm (nominal) thick extruded aluminum profile frame with suitable stiffening supports for structural rigidity, 1.5 mm thick aluminum back cover, 4 mm thick poly carbonate sheet with glare free face, supporting legs, breakable coupling etc. The letters and symbols shall be internally pasted/ screen printed with required coloring. The sign boards shall be uniformly internally illuminated with required number of LEDs strips to achieve required illumination level, alongwith drivers, internal control circuit, automatic changeover to function on both main & standby (runway/ taxiway) circuits etc and shall operate without any flickering when operated on input source of 2.8 Amps. to 6.6 amps. series current. The suitable arrangement shall be made for water tightness and locking arrangement. The signages shall be installed on 1:2:4 grade cement concrete of size 400x400x500 mm for each leg and total base of 150 mm thick for the distance of 1.5 mtr. all around the board including installation of isolating transformer, crimping/ jointing of plug & receptacles, laying of secondary leads, connections, earthing etc. complete as required. The taxiway guidance signages shall be as per ICAO and confirming to technical specifications. (legends shall be as approved by Engineer‐in‐charge).
19Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)
20Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.120 mm dia (OD-120 mm & ID-103 mm nominal)
21Supply of 90 mm high density polyethylene HDPE pipe (PE- 80, PN-6) as per IS - 4984 with up to date amendment along with accessories like socket, bend, couplers etc. complete as required.
22Laying of HDPE pipe (PE- 80, PN-6) of size up to 110 mm (OD) in suitable depth by trencheless horizontal directional drilling (HDD) method by deploying HDD machines with necessary arrangements complete as required as per the site requirements.(Excluding the cost of HDPE Pipe)
23Supply of cast iron isolating Transformer housing box, water tight round type, metal container of outside size 330 mm dia, height 450 mm made of 10 mm thick cast iron moulding all round, except the top surface, which is 15 mm thick , cast iron moulding suitable to receive a light fitting base plate/ cover plate on the top and underground for housing transformer, power cable and having one/two/ three nos holes as per site requirement on the periphery centre, 75 mm above bottom surface suitable to receive of 50 mm and 15mm dia GI/DWC HDPE/HDPE pipe as required. The box should have two SS earth bolts of M10x40 mm tapped inside near the hole (4\\" away from the hole centre) and having drain hole at the bottom suitably tapped to receive 15mm dia GI pipe and having clear opening of 220 mm at the top surface and 06 Nos. M10 tapped hole having centre to centre distance of 260mm to receive fittings/base plate and bolts, etc complete as required.
24Installation of transformer housing boxes with a base concrete of 1:3:6 of size 630x630x100mm thick all round concrete of 1:2:4, 150mm thick top sloped with 1:2:4 cement including providing and fixing 300mm long 15mm dia \\"B\\" class GI pipe with check nut for drainage of water including excavation of soil and refilling, adjustment of CI boxes etc. complete as required.
25Installation, testing and commissioning of medium intensity LED type taxiway edge light fitting on the existing transformer housing box including installation of isolating transformer, crimping/jointing of plug & receptacles, laying of secondary leads, connections, earthing etc. complete as required and includes supply of all materials excluding fixture, secondary lead, isolating transformer and plug & receptacles.
26Kerfs cutting with machine in taxiway/runway of PQC/bituminous surface of suitable depth and width for 1 or 2 nos secondary lead along with earth cables and laying of secondary lead and earth cable by wrapping tape i/c refilling the same by suitable sealing material etc. complete as required and as per instruction of EIC.
27Installation, testing and commissioning of inset type runway/ taxiway edge light by core cutting in the runway/taxiway/apron pavement, fixing the shallow base with dobefil and hardener, installation of isolating transformer, crimping/jointing of plug & receptacles, laying of secondary leads, connections, earthing etc. complete as required and includes supply of all materials excluding fixture, secondary lead, isolating transformer and plug & receptacles.
28Laying one number 5 KV grade Airfield lighting cable of size single core 6 / 16 Sqmm, 2x4 Sqmm secondary & control cable in the existing RCC/ HUME/ STONEWARE/ METAL/ HDPE/DWC pipe as required.
29Laying of one number 5 KV grade Airfield lighting cable of size single core 6/16 Sqmm and 2x4 Sqmm secondary lead & control cable in the existing masonry duct as required.
30Excavation of the trench in the hard rock not exceeding 1.5 metres in width, and lift upto 1.5 meters, including getting out the excavated soil and disposal of excavated soil as directed with in a lead of 50 mtrs.
31Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement etc. with charcoal/ coke and salt as required.
32Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
33Providing and fixing 6 SWG dia G.I. wire on surface or in recess or in HDPE/metal pipe for loop earthing along with cable as required.
34Upgradation and integration of existing Electro System make Airifeld lighting control and monitoring system (ALCMS) for newly added taxi-C lighting facilities including taxiway edge lights, guard lights, Signages etc complete with all required upgradation/enhancement of software and hardware for the units installed in ATC and CCR hall meeting ICAO/FAA.
35Supply of following size 1.1 kv grade, XLPE insulated and PVC sheathed, FRLS at outer sheath, Aluminium conductor armoured power cable conforming to IS: 7098(Part-1) 1988 with up to date amendments etc. complete as required.
364 Cx25 Sqmm
373.5C x 150 Sq.mm
38Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3.5 Core x 150 Sq.mm size cable in the existing RCC/ HUME/ STONEWARE/ METAL/ HDPE/DWC pipe as required.
39Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size up to 35 sq. mm in the existing RCC/ HUME/ METAL/HDPE/DWC pipe as required.
40Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Upto 50 sq. mm size in the existing masonry open duct as required.
41Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.(i).4C X 25 sq. mm
42Supplying and making end termination with suitable size 4 pole terminal block and aluminium lugs for 4C X 25 sq. mm PVC insulated and PVC sheathed / XLPE, Armoured, aluminium conductor cable of 1.1 KV grade as required.
43Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 x 150 Sqmm, PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade complete as required.
44Supplying and making straight through joint with heat shrinkable kit including copper ferrules and other jointing materials for size upto 6/16 sqmm, of PVC insulated and PVC sheathed copper conductor cable of 5 KV grade as required.
45Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for size of 3.5 x 150 Sqmm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
46Supply of hot dip galvanized 5 meter long octagonal pole, having 130mm bottom, 70mm top, 3mm section thickness, with base plate of size 200 mm x 200 mm x 12 mm, 4 nos of M16 X 600mm J-hook etc. without any electrical accessories etc complete as required.
47Supply, Installation, testing and commissioning of 25 watt LED type out door lighting luminaire with die cast aluminium housing, suitable for install on pole having arm dia 45-50 mm, having uniform lighting distribution with minimum luminare efficiency of 110 lumen per watt including driver and other accessories, IP66 ingress protection with five year warrenty from OEM and as per technical specifications including wiring with 3x1.5 Sqmm PVC cable etc. complete as required.
48Erection of G.I. octagonal pole, 5 Mtr. height in Reinforcement cement concrete (RCC) 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) foundation of size 450mm x 450x mm and depth of 1100 mm (900mm below the ground and 200m above the ground) with suitable length j hooks , nut etc as per attached drawing in technical specifications, etc complete as required.
49Dismantling of existing octagonal GI pole height upto 6m with the help of hydra/crane from operation area i/c shifting of poles to AAI store/other location in Airport to as per instruction of enginner in-charge.
50Painting of foundation of light poles (5 Mtr) with 2 coats/layers of white cement including cleaning the surface etc complete as required.
51Numbering of GLF fittings with letters in yellow on black back ground as per inscription approved of Engineer in charge as required.
52Providing, laying and fixing 150mm dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
53Providing, laying and fixing 300mm dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
54Providing and fixing of 50 mm dia G.I. pipes B class conforming to IS 1239 complete with G.I. fittings & accessories including trenching and refilling etc. complete as required.
55Providing and fixing of 15 mm dia G.I. pipes B class conforming to IS 1239 complete with G.I. fittings & accessories including trenching and refilling etc. complete as required.
56Supplying and fixing of MS cover plate suitable for CI Housing Box etc complete as required.
57Supply & fixing of 25mm GI flexible pipe on the secondary cable etc complete as required.
58Design, Fabrication, Supply, installation, testing and commissioning of vermin proof, dust proof, front operated, cubicle type, floor mounted, double door, outdoor LT panel made out of 2 mm thick CRCA sheet duly rust inhibited, powder coated paint, fully compartmentalized complete with double hinged front door with lockable arrangement etc. including necessary iron channel stand, control wiring, with mechanical interlocking, etc. and having following accessories.INCOMER2 Nos. 200A 4P MCCB (Ics=Icu=25KA) with rotary operating mechanism including terminal extension.Each Incomer shall have one set of the following items:Digital Multifunction Meter, suitable for measure Volatge, Current, Energy, frequency, power factor etc.with CT ratio programmable and auto ranging along with suitable range CTs.1 Set of Indication Lamps, LED type, R,Y,B and MCCB 'ON', 'OFF' and Trip lamps with protection MCBs.BUS COUPLER1 Nos. 200A 4P MCCB (Ics=Icu=25 KA) with rotary operating mechanism including terminal extension.Bus coupler shall have indication 'ON', and 'OFF' lamps with protection MCBs.BUS BAR1 Set of 250A TPN Busbars of aluminium alloy.OUTGOING04 Nos. 63 A TPN MCCB (Ics=Icu=25 KA) with thermal magnetic release.02 Nos. 32 A TPN MCCB (Ics=Icu=25 KA) with thermal magnetic release.6 Nos.LED type 'ON' Indication Lamp at each outgoing.
59Supply of 1100 V Flexible, 10 core 2.5 Sqmm Cable with bright annealed bare copper conductor, FR PVC Insulated & PVC Sheathed round Wires as per IS-694 up to date ammended. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57886838
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 1.02 Crore
LAST DATE 27-10-2026
Authority
Authority Name Airports Authority Of India
Work Description Tender for Construction Of Link Taxi Track For Proposed New Fto At Kishangarh Airport. Sh-Electrical Work.
Basic Detail
Tender No AAI/KSG/ENGG(E)/NIT-05/2026-27
Bidding Type Tender
Location
City Ajmer
State Rajasthan
Key Dates
Publish Date 06 Oct 2026
Submission Date 27 Oct 2026
Open Date 28 Oct 2026
Finance
Tender Value 1.02 Crore
Tender Fee 1180
EMD 2.05 Lakhs
Exemption Not Available
Document List
81810ed4-dcd1-4848-9439-586a002edb14.html
BOQ_342163.xls
TenderDcuments.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Oct 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

81810ed4-dcd1-4848-9439-586a002edb14.html

xls

BOQ_342163.xls

pdf

TenderDcuments.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender