Drinking Water Supply and Sanitation Government Departments Closing in 31 days TDR #57886831

Tender For Estimate For Structural Rehabilitation Measures, Basic Facilities Improvement And Hydro Mechanical Works At Mirzapur Dam, Distt. S.A.S. Nagar, Punjab Under Drip Project.

Issued by Government Departments · S.a.s Nagar, Punjab
Tender Value
63.07 Lakhs
Estimated cost
Bid Submission
10 Nov 2026
31 days left
EMD
1.26 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
S.a.s Nagar → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Estimate For Structural Rehabilitation Measures, Basic Facilities Improvement And Hydro Mechanical Works At Mirzapur Dam, Distt. S.A.S. Nagar, Punjab Under Drip Project.

BOQ

Name of Work:- Estimate for Structural Rehabilitation Measures, Basic Facilities Improvement and Hydro Mechanical Works at MIRZAPUR DAM, Distt. S.A.S. Nagar, Punjab under DRIP Project.
Sl. No. Item Description
1Dismantling cement conglomerate floors 25mm to 50mm thick including concrete base.
2Earth work in excavation in foundations trenchesetc. in all kinds of soil where Pick-Jumper work isnot involved and not exceeding 2.0 metres depthincluding dressing of bottom and sides oftrenches, stacking the excavated soil clear fromthe edge of excavation and subsequent fillingaround masonry in 15 cm, layers with compactionincluding disposal of all surplus soil as directedwithin lead of 30 metres.
3Cement concrete 1:4:8 with stone ballast 40mm gauge. mixing by mechanical means using concrete mixer volumetric type
4First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth.
5First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.
6Extra for work done in additional storey upto 4metre above the top of structural roof of lowerstorey for Brick Work/ Concrete Block/ ClayBlock.
7First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth.
8First class 225mm thick honey-comb burnt brick work laid in cement sand mortar 1:4
9First class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level.
10115mm thick brick wall in cement sand mortar 1:4 without reinforcement in superstructure
11Extra for bitumen painting @0.69 kg per sqm
12Damp proof course 4cm thick of cement concrete 1:2:4 with water proofing compound as per manufactures guidelines
13Centring and shuttering for sides and soffits of beam, beams launchings girders bressummers, lintels.
14Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
15Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundationand plinth.
16Cold twisted deformed (Ribbed/Tor Steel Bar) Bars Fe 500 grade as per IS 1786-2008 for R.C.C. works, where not including in the complete rate of R.C.C. including bending and placing in position complete in all respect.
1712.5 mm thick cement plaster 1:4.
1820mm thick cement plaster 1:4 in two coat work.
19Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish
20Distempering with Acrylic washable oil bound distemper (of approved manufacture) two coats over one priming coat to give an even shade
21Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
22Finishing walls with acrylic smooth exterior paint of required shade with two coats applied @ 1.67 litre/10sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 sqm
23Water proofing treatment of Roof Slab with High performance cementitious two component product, consisting of a powder component and an acrylic polymer using two coats ( Dr Fixit Roofseal flex - Packaging Size: 12 .5 kg (7.5 kg powder + 5 kg polymer) / equivalent water proofing Solution ). The slurry thus formed by mixing the two, is to be applied on new roofs to forms a seamless, highly elastic, non-toxic waterproofing layer on the roof with a life expectancy of 7 years. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge.
24Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another laver of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg/sqm top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing etc.
25Laying of Dry Brick Ballast 40 mm gauge for flooring
26M-12) Bricks First Class (Clay/Fly Ash) (at kiln site):-Brick bats from well burnt or burnt bricks
27Base course of floor consisting of 100 mm thick cement concrete 1:8:16 with stone aggregate 40 mm gauge and 100 mm fine sand filling using mechanical mixer for mixing of material.
28Providing and laying vitrified floor tiles 600x600mm size premium quality, manufactured using Soluble Salt Technology, with water absorption less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 fine sand ) for new flooring laid with cement based high polymer modified quick set tile adhesive (water based) of approved make IS 15477 marked using 5 Kg adhesive per sqm of tile area in average 3mm thickness over existing base etc., complete
29Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 200 x 300 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete
30Supply & Fixing of pressed steel frames (Chowkats) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section(standard design latest) including iron lugs (hold fasts) iron hinges, confirming to P.W.D. specifications including bolts for fixing stops, lock- notch provision for receiving tower bolts, Hydraulic spring and finished with one priming coat of approved quality, fixed in position, including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete. Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter
31Hollock wood doors shutter windows shutter including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position. Panelled, glazed or glazed and panelled (Double leaf), 40mm thick.
32Wire gauge Hollock wood door shutter without springs housed in chowkhat. 35 mm Thick
33Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete. I.S.I Designation No. II (size of door 701mm to 850mm).
34Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect Aluminium khunti with 6 pegs
35Providing and fixing 6” stainless steel handles ISI marked on door & window frames complete in all respect as directions of Engineer – in Charge
36Providing and fixing 6” stainless steel bolts ISI marked on door & window frames complete in all respect as directions of Engineer – in Charge
37Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. (a) With special quality paint.
38Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete.
39Painting two coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
40Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
41Bottom Khurra on ground 1.2m x 0.6m consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5mm thick cement plaster 1:3.
42Embedding 100mm dia CI rain water non pressure ISI mark pipe in cement mortar during masonry work.
43Providing and fixing cast iron shoe for rain water pipe on wooden plugs fixed on wall face including filling the joints with spun yarn and cement mortar 1:2.
44RECESSED PVC CONDUIT PIPE WIRINGSYSTEM WITH MODULAR SWITCHES:Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVCconduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes(1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators(two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/universal Socket (shuttered), 6/10Amp. Switches,16/20Amp. switches with indicator etc. and coveredwith Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\"deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (withfinishing the surface):- Wiring fan point with sheet metal fan box (shape hexagonal & sheet thickness not less than 1.60 mm) in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade with step type electronic fan regulator 100 watts.
45RECESSED PVC CONDUIT PIPE WIRINGSYSTEM WITH MODULAR SWITCHES:Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVCconduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes(1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators(two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/universal Socket (shuttered), 6/10Amp. Switches,16/20Amp. switches with indicator etc. and coveredwith Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\"deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other pettymaterial etc., including the cost of above material, cutting and filling up of chases (withfinishing the surface):- Wiring light point in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade
46RECESSED PVC CONDUIT PIPE WIRINGSYSTEM WITH MODULAR SWITCHES:Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVCconduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes(1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators(two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/universal Socket (shuttered), 6/10Amp. Switches,16/20Amp. switches with indicator etc. and coveredwith Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\"deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other pettymaterial etc., including the cost of above material, cutting and filling up of chases (withfinishing the surface):- Wiring 3 pin 6 Amp. wall socket (Shuttered) point in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100 volts grade
47RECESSED PVC CONDUIT PIPE WIRINGSYSTEM WITH MODULAR SWITCHES:Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVCconduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes(1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/universal Socket (shuttered), 6/10Amp. Switches,16/20Amp. switches with indicator etc. and coveredwith Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\"deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other pettymaterial etc., including the cost of above material, cutting and filling up of chases (withfinishing the surface):- Wiring 3 pin 16/20 amp. power plug control (shuttered) and switch
48Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 2.5sq.mm (Un-sheathed)
49Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 leftbare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 4sq.mm (Un-sheathed).
50XLPE INSULATED UN-ARMOURED CABLES (LOOSE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- Overall size 10sq.mm (4Core) Un-armoured (Loose)
51Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1/2mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- Double Walled Corrugated HDPE Pipe 120/ 103.5mm (Outer/ Inner dia.)
52Cement Concrete 1:3:6 around pipe for protection. With stone ballast and mixing by mixing by mechanical means using concrete mixer volumetric type
53Providing and fixing in position Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) size 62x37x67 cm with P trap or S trap of approved make (to the approval of the Engineer-in-charge) and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge
54Providing and fixing jet spray with 2'-6\\" long PVC pipe. With C.P. Brass nut
55Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect
56Providing and fixing in position toilet paper holders of approved make (to the approval of Engineer-in-charge ) fixed in to wall with C.P brass screws complete in all respect. C.P. brass toilet paper holder
57Providing and fixing in position Acrylic towel Rails size 20mm dia 600mm long of approved make (to the approval of Engineer-in-charge) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.
58Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. Size 450mmx300mm
59Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 110mm o/d single socket SWR UPVC pipe lines laid complete.
60Providing and fixing in position SWR UPVC soil waste vent or antisyphonage pipes as per IS -13592 of approved make including cutting, jointing, wastage. 75mm o/d SWR UPVC pipe lines laid complete.
61Providing and fixing in position SWR UPVC soil waste vent or antisyphonage pipes as per IS -13592 of approved make including cutting, jointing, wastage. 160mm o/d SWR UPVC pipe lines laid complete.
62CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-inCharge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. SDR 11 CPVC pipes & fittings 20mm o/d.
63CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-inCharge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. CPVC SDR 11 Pipe & fitting 25mm o/d.
64Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. 25mm i/d G.I. Union.
65Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect.
66Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-in-charge )with various fixtures complete in all respect. C.P. Brass extension piece, 25mm long to 50mm long
67Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect.
68Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. C.P. brass Bib cock long nose/ long body foam flow without flange
69Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect.
70Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P.brass 15mm Angle valve without flange.
71Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 600 mm with C.P. Brass nutt.
72Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick, grade-304 (18/8) with waste coupling complete in all respect (Rectangular Sink with Deluxe Border Single Bowl Overall Size 555 mm x 475mm x 200 mm).
73Providing and fixing Centrifugally cast ironFloor traps conforming to I.S.I. Specification (IS:3989) of approved make (to the approval of Engineer-in-charge) of the self cleaningdesign with C.P. brass hinged grating with frame with or without vent arm and including cement concrete 1:2:4 under and around thefloor trap where required upto floor level complete in all respects including cutting andmaking good the walls and floors,etc. minimum depth of water should be 150mmwith a minimum seal 50mm. 100mm x 75mm i/d 300 mm long
74Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber. 150mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm
75Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. Size 450mm x 450mm inside with RCC 455mm x 455mm cover and frame light duty double seal
76Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Tripple Layer Tanks
77Providing and fixing in position automatic brass Ball Cock in tanks. Brass Ball Cock with rod and Plastic Ball , 25mm i/d
78Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) Size 600mmx450mm
79Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulatedcopper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuitidentifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&Ndistribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles andbonding to existing earth etc:-Supply and erection of sheet metal SP&N Double Door Distribution Board 16 way each
80Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contactindication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-Supply and erection of MCB Double Pole 40amp. (10kA, Curve-C) for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts
81Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contactindication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-Supply and erection of MCB Single Pole 6-32amp. (10kA, Curve-C) for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts.
82Supply and erection of Ceiling Rose (Flush Piano type) switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.,
83Supply and erection of Bakelite Batten Holder (Large size) switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.,
84Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect b) Glazing area above 0.09 sqm, 4mm thick or 10.78 Kg/ sqm.
85Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect (C) G.I. tank nipple 25mm i/d ,
86Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position.
87Supply of Ceiling Fan 1200 mm
88Erection of ceiling/cabin/exhaust fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) Cable 0.75 sqmm Complete. For Celing Fan
89Supply of Exhaust Fan
90Erection of ceiling/cabin/exhaust fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) Cable 0.75 sqmm Complete. Erection of Exhaust fan with louver shutter on the wall/ window grill
91Supply of LED bulb 12 watt.
92Erection of light fixtures on wall /ceiling having connection with PVC insulated PVC sheathed two single core copper conductor (FR) Cable 0.75 sqmm Complete. Erection of 1x20/28/36/40W Box Type (LED/ Fluorescent) light fixture
93Corrugated G.I. Sheet roofing 0.80 mm thick fixed with galvanized iron J or L hooks 10mm dia, G.I. Limpot and bitumen washers complete excluding the cost of purling rafters and trusses
94Dismantling brick work tile, masonry or tile lining
95In Lime
96In cement
97Scraping
98White wash and colour wash
99Cement plaster
100Removing doors and windows together with thedismantling of walls
101Doors of area 3 sqm and below.
102Windows of area 3 sqm and below
103Clerestory windows of area 3 sqm and below
104DISMANTLING WIRING POINTS & FITTINGS:Dismantling old wiring points including necessary repairs to wall etc:-
105Fan, light or call bell point
106Wall socket, power plug point
107Removal of existing Tube fitting etc.
108Removal of existing Ceiling fans/ Exhaust fans
109Boring with casing pipe for tube well in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested, equipment as required such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect (a) Boring with 150mm id Housing Pipe. Upto 150 m depth BGL.
110Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818-2010, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer incharge. (a) 100 mm nominal size dia.
111Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge . (a) 100 mm nominal size dia.
112Providing, Laying, fixing & jointing of ISI Marked H.D.P.E. Pipes as per ISI - 4984-1995 casting along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. H.D.P.E pipe of 10 Kg. PE-80, 40 mm o/d..
113Supply & erection of electrically driven water lubricated submersible pumping set should strictly confirm to ISI:8034-1976 with latest amendments, directly coupled with Submersible electric motor capable to delivering 12000 Litres of water per hour against a head of 280 ft
114Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 4.0sq.mm (56/0.3mm), 3Core
115Supply and fixing of bail plug of MS Pipe complete with inverted U-hook attached to the bottom plug complete in all respect. 100mm nominal diameter (weight 14.5 kg per metre) 5.40 mm thickness
116Supply and fixing of well cap having thread to fix on housing pipe complete in all respect. 100mm internal diameter
117Providing and fixing of STARTER, MAIN SWITCH/MCCB 32 AMP along with wiring etc. in cubical pillar box type panel board complete in all respects.
118Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect
119Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. Water Cooler Full Steel Body 40/80 ltr Capacity without Stablizer
120Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect
121Dismantling metalling or dry brick ballast
122Construction of granular sub-base by providing material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MORD technical specifications
123Construction of granular sub-base by providing material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MORD technical specifications
124Providing and laying surface dressing in singlecoat using crushed stone aggregates of specifiedsize on a layer of bituminous binder VG-10 @ 1kgper sqm laid on prepared surface after cleaningthe road surface and rolling with 8-10 tonnesmooth wheeled steel roller complete as pertechnical clause 509 of MORT&H specifications
125Providing and applying tack coat with penetration grade bitumen VG-10 using bitumen pressure distributor at the rate of 0.40 kg per sqm on the prepared bituminous surface/granular surface treated with prime coat after cleaning the surface complete as per technical specifications
126Providing, laying and compaction of open - graded premix surfacing of 20 mm thickness consisting ofcrushed stone aggregates of specified gradingpremixed in a Continuous type hot mix plant withbituminous binder VG-10 @ 1.46kg per sqm, laidwith Paver Finisher Mechanical and rolling with asmooth wheeled roller 8-10 tonne capacity,finished to required level and grades complete asper technical clause 510 of MORT&H specification
127Providing and laying of premix sand seal coat premixed in Continuous type hot mix plant using specified fine aggregates and penetration grade bitumen VG-10 @ 0.68kg per sqm, laid to the specified levels, grade and cross fall complete as per technical clause 511 of MORT&H specification
128Place Identification sign board 900x600mm rectangular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012 fixed over 4mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on two square hollow steel section post 60x60x3.2mm conforming to IS 4923 firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications. Using high intensity Microprismatic grade retro reflective Sheeting Type XI as per ASTM D 4956 09 and as per IRC 67 2012 for retro reflective sheeting & a certified copy of test reports from anindependent test laboratory conforming to clause6.7 of IRC 67-2012.
129Definition Plate 600x200mm rectangular as per as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012. specifications. Fixed over 3mm thick Aluminium Composite Material (ACM) sheeting having aluminium skin thickness of 0.25 to 0.3 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame welded with vertical post of sign board complete as per clause 801 of MORT&H specifications. Supplier shall provide awarranty as per clause 6.9 of IRC 67-2012 for retroreflective sheeting & a certified copy of test reportsfrom an independent test laboratory conforming toclause 6.7 of IRC 67-2012 Using high intensity Microprismatic grade retro reflective Sheeting Type XI as per ASTM D 4956 09 and as per IRC 67 2012.
130Supply and Installation of 10 Kw Hybrid Grid tied Solar Power Plant with Batteries at Dam Site Complete in all respect as per Instructions of Engineer- in -Charge.
1311.8 meter high G.I. Barbed wire fencing 2.4m angle iron Post 50x50x6mm placed at every 3m centre to centre 0.6m below ground level, every 15th cost, end Post, Corner post suitably strutted and provided with 12 horizontal lines and to diagonals interwoven with horizontal wires fixed with GI staples, turn buckles etc. including foundation concrete 1:2:4 of size 0.30x0.30x0.75m for each post complete as per technical clause 808 of MORT&H Specifications.
132GI PIPE POLES: Supply and erection of G.I. pipe ‘A’quality of suitable length and dia. confirming to IS:1239 (Part-I) 1979,including fixing up to a given depth below G/L, the hole of excavation about 30cm dia. and given depth to be filled in up to 15cm below G/L with 1:2:4 cement concrete including painting of pole with two coats of approved aluminium paint as required:- (ii) G.I. Pipe Pole 6.1 metre Long, Dia. 80mm, Planting Depth 120cm with Pit Depth 135cm
133SINGLE ARM BRACKETS FOR GI PIPEPOLE:(i) Supply and erection of G.I. Pipe 40mm dia. (A-class) Single arm bracket of suitable length give a total overhang at a tentative angle of 100/105º, the bracket should be fixed on the top of the GI pipe pole having top outer dia. 80mm/100mm with GI reducer of suitable size with two coats of an approved aluminium paint complete in all respect as approved by the Engineer-in-charge at site:-(a) Single Arm Bracket 1 metre Long with G.I. Pipe Reducer 80mm x 40mm
134100 Watt LED Flood Light of Philips make
135PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III &HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-(ii) Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface)
136For cleats, Nuts & Bolts
137XLPE INSULATED UN-ARMOURED CABLES (LOOSE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-(i) Overall size 6sq.mm (2Core) Un-armoured (Loose)
138XLPE INSULATED UN-ARMOURED CABLES (LOOSE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- (xxxvii) Overall size 16sq.mm (4Core) Un-armored (Loose) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57886831
AUTHORITY Government Departments
TENDER VALUE 63.07 Lakhs
LAST DATE 10-11-2026
Authority
Authority Name Water Resources Department
Work Description Tender for Estimate For Structural Rehabilitation Measures, Basic Facilities Improvement And Hydro Mechanical Works At Mirzapur Dam, Distt. S.A.S. Nagar, Punjab Under Drip Project.
Basic Detail
Tender No 5
Bidding Type Tender
Location
City S.a.s Nagar
State Punjab
Key Dates
Publish Date 06 Oct 2026
Submission Date 10 Nov 2026
Open Date 10 Nov 2026
Finance
Tender Value 63.07 Lakhs
Tender Fee 1000
EMD 1.26 Lakhs
Exemption Available
Document List
0b170670-9336-4334-9977-4edd99bc564f.html
BOQ_360519.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 31 days
Nov 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 31 days

Tender Documents

Download All (ZIP) ↓
html

0b170670-9336-4334-9977-4edd99bc564f.html

xls

BOQ_360519.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders