Tender For Augmentation Of Receiving Station Kunzer From 2X10 Mva To 3X10 Mva Under Ut Capex
Tender Overview
Project Description
Tender for Augmentation Of Receiving Station Kunzer From 2X10 Mva To 3X10 Mva Under Ut Capex
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 29-Oct-2026 | Extension-I | Date | 07-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply, Installation, Testing and Commissioning of |
| 2 | Installation, testing and successful commissioning of 10 MVA Power Transformer including loading at ECSD Pampore, handling, Carriage upto site/ Unloading /Dragging /Assembling at site including insurance during transit (Complete Job) to Receiving Station ( Power Transformer to be provided by the Department) |
| 3 | Supply, Carriage upto site (including Loading/Unloading),Installation,Testing & Commissioning of 33 kV VCB (36 kV, 1250A, 26.2 kA, Outdoor Type of reputed make as per approved drawings/standards |
| 4 | Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 33 kV Isolator with Earthing Blade (36KV,800A,Outdoor,3 poles,25 KA) of reputed make as per approved drawings/standards |
| 5 | Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 33 kV Isolator without Earthing Blade (36KV,800A,Outdoor,3 poles,25 KA) of reputed make as per approved drawings/standards |
| 6 | Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 33 KV Current Transformer (33 KV, 1Φ, 2 Ratio 3 Core, Outdoor Type ; 300-150/5-5A) of reputed make including supply and fixing of suitable CT Clamps as per approved drawings/standards |
| 7 | Supply, Carriage upto site (including Loading/Unloading),Testing of 11kV/ 110 V, Three phase epoxy resin cast Voltage Transformer with rated burden 15VA per phase and accuracy class 0.5 (reputed make) |
| 8 | Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 33 kV Lightening Arrestors (33 kV, 10kA, Station class, ZnO, Polymer) gap less (1 No. per Φ) of reputed make as per approved drawings/standards |
| 9 | Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 33 kV C&R Panel along with O/C, E/F,REF and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port |
| 10 | Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 33 kV 10 kN Post Insulator Polymer 36kV,235kV Impulse, creepage distance 1224m of reputed make as per approved drawings/standards |
| 11 | Supply, Carriage upto site (including Loading/Unloading),Testing and Erection of Steel Tubular Pole, 11 Mtr. Long Pole(ST-410 SP-56) with planting depth of 1/6 th of the height of the pole, (11 mtr. Long ) as per approved drawings/standards |
| 12 | Supply & Laying of Cement bottoming for 11 Mtr ST Pole in 1:2:4 mix as per Standards 0.66 cum / pole including the Loading/Carriage/Unloading of required material. |
| 13 | Providing & Fixing of Pole Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip.25x3mmas per approved drawings/standards |
| 14 | Providing & Painting of 11 Mtr ST Poles with one coat of Red Oxide and two coats of aluminium paint as per approved drawings/standards |
| 15 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of G.I Pipe of Dia 150mm, 5.9 mm Thick 3 m long with G.I Base Plate 8 mm Thick as per approved drawings/standards |
| 16 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of GI Channel/Angle/Flat of sizes including clamps as per approved drawings/standards |
| 17 | Supply,Testing,Loading,Carriage,Unloading and fixing of Galvanised Nuts & Bolts of sizes |
| 18 | Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS( Polycab, Havells, KIE, Anchor or any other reputed make) as per approved drawings/standards |
| 19 | Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 6 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS( Polycab, Havells, KIE, Anchor or any other reputed make) as per approved drawings/standards |
| 20 | Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 4 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS( Polycab, Havells, KIE, Anchor or any other reputed make) as per approved drawings/standards |
| 21 | Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 2 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS( Polycab, Havells, KIE, Anchor or any other reputed make) as per approved drawings/standards |
| 22 | Supply & Fixing of Lugs, Ferrules etc. |
| 23 | Supply, Carriage upto site (including Loading/Unloading),Testing and fixing of 200 mm² ACSR Conductor( Panther) as per approved drawings/standards |
| 24 | Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fitting as per approved drawings/standards |
| 25 | Supply, Carriage upto site (including Loading/Unloading) Testing & fixing of Earth wire 7/4.00 mm sq. as per approved drawings/standards |
| 26 | Supply, Carriage upto site (including Loading/Unloading) Testing & fixing of GI flat for earthing (50x6) mm as per approved drawings/standards |
| 27 | Supply, Carriage upto site (including Loading/Unloading) Testing & fixing of T Clamps as per approved drawings/standards |
| 28 | Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 11 KV Outgoing SCADA Compatible VCB Panel Board (12 kV, 1250A, 25 kA-3 Sec, Indoor) with Numerical O/C, E/F relays confirming to IEC61850, Master Trip Relay, Mimic Diagram, Digital Voltmeter with VSS, Digital Ammeter with ASS, PF Meter, Annunciation Windows with annunciation relays(6-Windows), 3-phase Tri-vector meter -5 Amps DLMS Compliant with RS-485 port ,Double Ratio; Three Core(0.5,5P10,PS) Epoxy Casted CT with CTR :400-200/5-5A,TNC Switch, LR switch, Indication Lamps & other equipments as per approved Technical Specifications, of reputed make including Fixing of Earthing & Feeder Name Plate with Name of feeder written on it by using high intensity reflective Tape. (Reputed Make) |
| 29 | Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 11 KV Incomer SCADA Compatible VCB Panel Board (12 kV, 1250A, 25 kA-3 Sec, Indoor) with Numerical O/C, E/F relays confirming to IEC61850, Master Trip Relay, Mimic Diagram, Digital Voltmeter with VSS, Digital Ammeter with ASS, PF Meter, Annunciation Windows with annunciation relays(6-Windows), 3-phase Tri-vector meter -5 Amps DLMS Compliant with RS-485 port ,Double Ratio; Three Core(0.5,5P10,PS) Epoxy Casted CT with CTR :600-300/5-5A,Epoxy Casted PT with PTR :11KV/110 V, TNC Switch, LR switch, Indication Lamps & other equipments as per approved Technical Specifications, of reputed make including Fixing of Earthing & Feeder Name Plate with Name of feeder written on it by using high intensity reflective Tape. (Reputed Make) |
| 30 | Supply, installation, testing and commissioning of 11 kV Bus Coupler Panel with Adaptor Panel, complete with suitable VCB, numerical protection relay, CTs, operating mechanism, interlocking arrangement, metering and indication, control wiring, busbar extensions, supports, insulators, flexible/solid bus links, shrouding and necessary interconnections for matching with existing 11 kV switchgear, including all accessories, hardware, earthing, testing and commissioning, complete in all respects. |
| 31 | Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 11kV, Gapless Surge Arrestor,9 KV ,10 KA ,LA with Polymer housing, Stn. Type as per approved drawings/standards |
| 32 | Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 11 kV 630 mm² Single Core XLPE Cable armoured, FRLS (Havells/KEI/Polycab or any other reputed make ) as per approved drawings/standards |
| 33 | Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 11kV Indoor Heat Shrinkable Cable Termination Kits suitable for 630 mm² Single Core XLPE Cable (3M/Vitchem or any other reputed brand) as per approved drawings/standards |
| 34 | Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 11kV Outdoor Heat Shrinkable Cable Termination Kits suitable for 630 mm² Single Core XLPE Cable (3M/Vitchem or any other reputed brand) as per approved drawings/standards |
| 35 | Supply, Carriage upto site (including Loading/Unloading),Testing & laying of HDPE Pipe Outer Dia 160 mm Inner Dia 148 mm for 11kV XLPE Cable from Power Transformer to Control Room including excavation as per approved drawings/standards |
| 36 | Supply & Laying of Reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 20 mm nominal size for Transformer Bed foundation (3mx2.5mx1.5m) including Excavation of existing Earth,centering shuttering works, 15mm plastering (1:6),Curing, TMT Bars,Back Filling of Existing earth as per the requirement,Speading of Extra Soil in available space as per the directions of Engineer Incharge & Loading/Carriage/Unloading of required material (The job should be executed strictly as per approved KPDCL Drawings) |
| 37 | Supply & Laying of Reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 20 mm nominal size for Equipment Foundation and Gantry Foundation including Excavation of existing Earth,centering shuttering works, 15mm plastering (1:6),Curing, TMT Bars,Back Filling of Existing earth as per the requirement,Speading of Extra Soil in available space as per the directions of Engineer Incharge & Loading/Carriage/Unloading of required material (The job should be executed strictly as per approved KPDCL Drawings) |
| 38 | Supply, Carriage upto site (including Loading/Unloading), Fabrication, Installation & Testing of Earthing Mat (GI Flat 50mm x8 mm) as per approved drawings/standards (Joints should be welded properly and painting of joints to be carried out by using Red Oxide and Deeco Paint. The job includes the excavation of existing earth to the depth as per the KPDCL standards in vogue and back filling of good earth upto ground level after fixing the earth mat including spreading of extra soil in available space as per the directions of Incharge Engineer |
| 39 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of Earthing Electrode ( 3m long 40mm dia GI pipe) including their jointing to earthing mat through GI Strip (50x6)mm by welding/bolting and painting of joints with Red Oxide and Deeco Paint as per approved drawings/standards |
| 40 | Supply & Laying of Yard concrete in 1:2:4 mix (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 20 mm nominal size ) including excavation of earth as per the requirement, centering shuttering,Spreading of extra soil in available space as per the directions of Incharge Engineer & Loading/Carriage/Unloading of required material. |
| 41 | Supply, Laying & Spreading of Yard Metal by way of stone aggregate 20 mm nominal size including the Loading/Carriage/Unloading of required material. |
| 42 | Providing & Construction of 750 m Cable Trench by laying of Reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 20 mm nominal size including Excavation of existing Earth,Centring shuttering works, Angle Iron and TMT Bars as per the KPDCL standards, 15mm plastering (1:6), fabrication,Back Filling of Existing earth as per the requirement,Speading of Extra Soil in available space as per the directions of Engineer Incharge,Fixing of 8 mm thick chequered plates & Loading/Carriage/Unloading of required material as per the drawings/standards |
| 43 | Extension of existing Control Room building by dismantling the existing side wall and reconstruction of the extended portion, including foundation, RCC works, masonry, roof slab, plastering, flooring, doors/windows and other allied civil works, complete in all respects as per approved drawings and specifications |
| 44 | Construction and erection of structural steel truss over an area of 1.5 times the existing plinth area, including fabrication, fixing, welding/bolting, necessary supports and bracing, colour-coated profiled roofing sheets, ridge, flashing, gutters and all allied works, complete in all respects as per approved drawings and specifications. |
| 45 | Supply, Carriage upto site (including Loading/Unloading) & Fixing of Rubber Mat 1mx2m 19mm thick as per approved drawings/standards |
| 46 | Supply , installation and testing of Fire Fighting Equipment (3 No. Fire Buckets of 9 ltrs,having round bottom with handle, painted white from inside and post office red colour from outside , bottom is painted black. Filled with sand. |
| 47 | Supply, and Carriage upto site (including Loading/Unloading) of 33kV level Rubber Gloves as per relevant IS/standards |
| 48 | Supply, and Carriage upto site (including Loading/Unloading) of 11kV level Rubber Gloves as per relevant IS/standards |
| 49 | Supply, and Carriage upto site (including Loading/Unloading) of Safety Shoes (Ankle Boot) as per relevant IS/standards |
| 50 | Supply, and Carriage upto site (including Loading/Unloading) of Earthing Discharge rod 5 mtr long with 25 sq mm cable 12 mtr as per relevant IS/standards |
| 51 | Supply, Testing and Carriage upto site (including Loading/Unloading) of Aluminium Ladder 2x20' long, 3 mm thick extendable with rope and pully arrangement as per relevant IS/standards |
| 52 | Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of CCTV Complete(LED 32\\" with 06 No.AHD Cameras) of reputed make. |
| 53 | Supply, Testing and Carriage upto site (including Loading/Unloading) of HV Detectors all voltages along with attached fiber rod as per relevant IS/standards |
| 54 | Dismantling of existing outdated 11 kV VCB Panels, including careful removal, handling, loading, transportation/carriage up to Divisional Stores, unloading and stacking at Divisional Stores, complete in all respects as directed by the Engineer-in-Charge |
| 55 | Spares/Contengencies/T&P Items |
| 56 | Hiring of Vehicle (Scorpio/Bolero/Innova/Tavera or equivalent) to be used by the Engineer Incharge for supervision of the project including Fuel/Toll Tax/ Driver/ any other maintenace charges of the vehicle. The max. Kms to be driven per day is 120 Km. In case the vehicle is utilized less than 120 km on any given day, the payment shall be subject to deduction on account of actual fuel savings. Such deduction shall be worked out proportionately based on the approved mileage (km per litre) of the vehicle and the prevailing fuel rate. |
| 57 | Supply, Carriage upto site (including Loading/Unloading),Testing of 20 A Auxiallary Switch suitable for 11KV VCB reputed make |
| 58 | Supply, Carriage upto site (including Loading/Unloading),Testing of Limit Switch suitable for 11KV VCB reputed make Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 7 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender