Tender For Construction Of Faecal Sludge Treatment Plant (Fstp) Of Capacity 15 Kld At Chakradharpur Nagar Parishad And Operation And Maintenance Of Fstp For 5 Years At West Singhbhum Jharkhand
Tender Value
6.80 Crore
Estimated cost
Bid Submission
22 Oct 2026
14 days left
EMD
6.80 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
West Singhbhum → Jharkhand
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Faecal Sludge Treatment Plant (Fstp) Of Capacity 15 Kld At Chakradharpur Nagar Parishad And Operation And Maintenance Of Fstp For 5 Years At West Singhbhum Jharkhand
BOQ
| Sl. No. | Item Description |
| 1 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A)and disposal of excavated earth as obtained to a distance upto 50m, including all lifts, levelling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design , building specification and direction of E/I |
| 2 | Filling in foundation trenches & plinth in layers not exceeding 150mm thick, well watered, rammed, fully compacted & fine dressed with earth obtained from excavation of foundation within a lead of 50m & lift of 1.50m all complete as per buiding specification and direction of E/I |
| 3 | Excavation in Soil using Hydraulic Excavator and Tippers with Disposal upto 1000 metres.Excavation for road work in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom andside slopes, in accordance with requirements of lines, grades and cross sections, and tranporting to the embankment location within all lifts and lead upto 1000 m |
| 4 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 5 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 6 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mmto 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge |
| 7 | Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete |
| 8 | Providing PCC in nominal mix of 1:2:4 in foundation with approved quality of stone chips with 20mm to 6mm size graded and clean coarse sand of FM of 2.5 to 3 including screening , shuttering, mixing cement concrete & placing in position , striking, vibrating, curing, taxes & royalty all complete as per building specification & direction of Engineer in charge |
| 9 | Providing PCC in nominal mix of 1:3:6 in foundation with approved quality of stone chips with 20mm to 6mm size graded and clean coarse sand of FM of 2.5 to 3 including screening , shuttering, mixing cement concrete & placing in position , striking, vibrating, curing, taxes & royalty all complete as per building specification & direction of Engineer in charge |
| 10 | Providing and laying in position cement concete of soecified grade excluding the cost of centering and shuttering - All work up tp plinth level 1:4:8 (1 cement :4 coarse sand (Zone -III) :8 graded stone aggregrate 40 mm normial size) |
| 11 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). |
| 12 | All works above plinth level upto floor V level |
| 13 | Providing Tor steel reinforcement of 8mm. dia rods as per approved design and drawing -do- -do- TMT Fe 500 (Only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL) |
| 14 | Providing Tor steel reinforcement of 10mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL)) |
| 15 | Providing Tor steel reinforcement of 12mm.16mm,20mm and 25mm Dia. bars as per approved design and drawing -do- TMT Fe 500 (Only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL) |
| 16 | Supplying, fitting and fixing M.S. grill gate with M.S. grills made of 20x6mm M.S. flats or 16mm square bars fitted on 25x25x6mm M.S Angle frame including cost of fabrication , providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/l. |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete |
| 18 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for Shelves (Cast in situ) |
| 21 | lintels, beams, plinth beams. girders. bressumers and cantilevers. |
| 22 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 23 | Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete |
| 24 | providing designation 75 B brickwork in C M ('1 :6 ) in foundation and Plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing. taxes and royalty all complete as per building specification and direction of E/l. |
| 25 | Providing designation 75A brickwork in CM (1:3) in superstructure with approved quality of clean coarse sand of FM 2 to 2,5 including providing 10mm thick mortar joints , cost of screening, materials, scaffolding, raking out joints to 15mm depth curing, taxes and royalty all complete as building specification and direction of E/I |
| 26 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 27 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 28 | Providing at all heights, levels and locations Aluminium profile industrial troughed sheet of Alloy 31500/31000/40800, conforming toIS 1254, IS 737, IS 2676. The sheet shall be fixed using self drilling/ self tapping SS screws of size 5.5x65 mm with EPDM seal completeupto required pitch in horizontal, vertical or curved surfaces i/c cutting to size and shape where required as per specifications, detail drawings and direction of Engineer-in-Charge. The rate shall be inclusive of all screws, seal, ridge, labour, scaffolding, machinery for fixing and approved sealent where required etc. but excluding the cost of purlins, rafters and trusses. 0.71 mm thick, the profile detail width 1044/920 mm, cover width 1000/875 mm. |
| 29 | Providing 1.5mm cement punning including curing carriage of water with all leads and lifts as per building specification and direction of E/I. |
| 30 | Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of FM 1.5 with 5% cico or any other approved water proofing compound including screening, curing, with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 31 | Providing 19mm thick water proof cement plaster (1:3) with clean coarse sand of FM 1.5 with 5% cico or any other approved water proofing compound including screening, curing, with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 32 | Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or sand paper , applying putty wherever required, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/I |
| 33 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 34 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 35 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 SQM) over and including priming coat of exterior primer applied @ 2.20kg/10 SQM |
| 36 | Providing at all heights, levels and locations Aluminium profile industrial troughed sheet of Alloy 31500/31000/40800, conforming to IS 1254, IS 737, IS 2676. The sheet shall be fixed using self drilling/ self tapping SS screws of size 5.5x65 mm with EPDM seal completeupto required pitch in horizontal, vertical or curved surfaces i/c cutting to size and shape where required as per specifications, detail drawings and direction of Engineer-in-Charge. The rate shall be inclusive of all screws, seal, ridge, labour, scaffolding, machinery for fixing and approved sealent where required etc. but excluding the cost of purlins, rafters and trusses. 0.71 mm thick, the profile detail width 1044/920 mm, cover width 1000/875 mm. |
| 37 | Providing and stacking Canna dwarf of height 25 to 30 cm., 2 to 3 suckers in earthen pots of size 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge. |
| 38 | Providing and Stacking of Lemon grass of ht. 30 cm with multi branches in Poly bag of size 20cm. as per direction of the officer-in-charge. |
| 39 | Providing designation 75 A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. |
| 40 | Providing 50mm thick cement concrete flooring (1:2:4) with 20mm-6mm size graded stone chips finished with floating coat of neat cement in panels including cost of curing, finishing the surface smooth, taxes & royalty with all complete as per building specification and direction of E/I |
| 41 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement plaster (!:3) and jointed with grey cement slurry flush pointed with white cement including rubbing, polishing and cost of curing, taxes and royalty all complete as per building specification and direction of E/I |
| 42 | Providing and laying vitrified floor tiles in different size(thickness specified by manufacturer) with water absorption less than 0-8% and conforming to IS 15622/ISO 13006 of approved make in colors & shade laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) , jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc complete ( size of tiles 600 X600mm) |
| 43 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble.Area of slab over 0.50 sqm |
| 44 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade |
| 45 | Providing at all heights, levels and locations Aluminium profile industrial troughed sheet of Alloy 31500/31000/40800, conforming to IS 1254, IS 737, IS 2676. The sheet shall be fixed using self drilling/ self tapping SS screws of size 5.5x65 mm with EPDM seal complete upto required pitch in horizontal, vertical or curved surfaces i/c cutting to size and shape where required as per specifications, detail drawings and direction of Engineer-in-Charge. The rate shall be inclusive of all screws, seal, ridge, labour, scaffolding, machinery for fixing and approved sealent where required etc. but excluding the cost of purlins, rafters and trusses. 0.71 mm thick, the profile detail width 1044/920 mm, cover width 1000/875 mm. |
| 46 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 47 | Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of FM 1.5 with 5% cico or any other approved water proofing compound including screening, curing, with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 48 | Providing 19 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 49 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 50 | Providing two coat of oil bound distemper of approved shade and make over a primer coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding, washing floors and taxes all complete as per building specification and direction of E/I. |
| 51 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l. |
| 52 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 53 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment |
| 54 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 55 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) |
| 56 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners,all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6mm for diagonal braces and central cross piece. |
| 57 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 58 | Water proofrng for Old and New Roof Slab :- Providing and laying water prooflng treatment on roof slab by applying two Component, factory a designed ready to use, acrylic modified flexible material applied with brush, roller or spray waterproofi ng coating as per manufacturer specification-With following steps :-(a)surface preparation :-Provrding and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika lndia Pvt.Ltd./ MYK Schomberg / Dr Fixit/Fosroc or equrivallent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with '150mm X '150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent Before chamfering a prime coat shall be given with theslurry of acrylic polymer Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete.(c) :2nd Coat:- To apply the 2nd coat of two component acrylic modified,ready to-use, flexible cementitious material right angle to the '1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kg/ Sqmt/coat. For the purpose of measurement the entire treated surface will be measured.\\" Alter three days of drying the 2nd coal , the rain water outles to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification lo be done as per satisfation of E/c. The Watqrproofing Brand:*Sika Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2Kl MYK Aqraiin TG Product Performance - Chemical Base Part A.Acrylic copol;,mer, Part 13 Specially graded cementitious powder -Density 1.6 kg/l (mixed density) at +270C Tensile Strength -2 N/mm2 after 28 Days (with Fibre cloth) (According to ASTM D 2370)Pullout Bond Strenth-2 n/mm2 (concrete failure) (According to ISO.4624) Slant-Shear Bond Strength -4 N/mm2 (According to FIP 5.15) Elongation at Break -35% without Fibre Cloth and 20% wilh Fibre Cloth (According to ASTM D 2370)D Protection of treated with pcc :- The treated surface shourd be covered with 25mm/50mm PCC of M-20 grade(1:1.5:3) with proper slope ( 1:120) towards the rain outlets in alternatepanels of 2 mtx2mt keeping 6 mm gap between the panel joint. integral water proofing admixture conforming to lS 2645 @ of 100 ml perbag of of cement to be addedin the screed concrete (paid separately for thts ltems all corners shall be charfered with 150mm X 150 mm fillet. The rain water outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of Sika lndia Pvt.Ltd / IVIYK Schomberg / Dr FixiUFosroc .For the purpose of measurement the entire treated surface will be measured.\\"(e)Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand - Sika lndia Pvt Ltd / MYK Schomberg / Dr Fixit/Fosroc |
| 59 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 60 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 61 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete .150MM PIPE |
| 62 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge100 mm nominal size dia |
| 63 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. |
| 64 | Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed material to work site, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401for grading - III materia |
| 65 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechnical plant carriage of mixed material by tipper to site , for all leads & lifts, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. |
| 66 | Providing and laying bituminous macadam with highercapacity hot mix plant using crushed aggregates ofspecified grading premixed with bituminous binder,transported to site, laid over a previously preparedsurface with paver finisher to the required grade, leveland alignment and rolled as per clauses 501.6 and 501.7to achieve the desired compaction.for grading I (40mm nominal size |
| 67 | Providing and laying bituminous concrete with highercapacity batch type hot mix plant using crushedaggregates of specified grading, premixed withbituminous binder @5.4 percent of mix and filler,transporting the hot mix to work site, laying with ahydrostatic paver finisher with sensor control to therequired grade, level and alignment , rolling with smoothwheeled, vibratory and tandem rollers to achieve thedesired compaction as per MORT&H specificationclause no. 507 complete in all respects. |
| 68 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern Near Office and operator's room |
| 69 | Cast-in-Situ Cement Concrete M20 Kerb (Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-15 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409) |
| 70 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 71 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 72 | Extra for depth for manholes :Size 90x80 cm With common burnt clay F.P.S. (non modular)bricks of class designation 7.5 |
| 73 | Providing & fixing of CI manhole cover of size 600mm dia ID(5116877-83531042841) |
| 74 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 75 | Providing and laying of coarse aggregate size as below after washing & sieving to make it free from fines & dust.Stone Aggregate (Single size) : 40 mm nominal size |
| 76 | Providing and laying of coarse aggregate size as below after washing & sieving to make it free from fines & dust.Stone Aggregate (Single size) : 12.5 mm nominal size |
| 77 | Providing and laying of coarse aggregate size as below after washing & sieving to make it free from fines & dust.Stone Aggregate (Single size) : 06 mm nominal size |
| 78 | Coarse sand (zone III) |
| 79 | Coarse sand (zone III) (at 70% openings) |
| 80 | Hollow Blocks (200mm X 200mm X 100mm) |
| 81 | Supply at site well decayed farm yard manure (supply at site of work well decayed farm yard manure from any available source , approved by engineer in charge including cleaning and stacking) |
| 82 | Spreading of sludge farm yard manure or/and good earth in required thickness (cost of sludge, farm yard manure or/and good earth to be paid for seperately) |
| 83 | Turfing lawns with fine grassing including ploughing, dressing (Turfing lawns with fine grassing including ploughing, dressing, including breaking of clods, removal of rubbish, dressing and supplying of doobs grass roots at 10cm apart including supplying and spreading of fam yard manure at rate 0f 0.6 cum per 100sqm) |
| 84 | Maintenance of lawns with fine grassing for one year |
| 85 | Planting flowering plants and shrubs in central verge |
| 86 | Maintenance of flowering plants and shrubs in central verge for 1 year |
| 87 | Planting of trees and their maintenance for one year (planting of trees by the road side (avenue trees) in 0.60m dia holes, 1m deep dug in ground, mixing the soil with decayed farm yard/sludge manure, planting the saplings, backfilling the trench , watering , fixing the tree guard and maintaining the plants for one year) |
| 88 | Carraige of materials |
| 89 | Sand (10km) |
| 90 | Local sand (3 km) |
| 91 | chips (22km) |
| 92 | Bricks |
| 93 | metal (22km) |
| 94 | PLUMBING WORK |
| 95 | Supplying and fitting vitreous white glazed earthen ware wash hand basin of parry or Hindusthan or any other I.S.S. approved make supported on CI or R.S. brackets 32mm C.I brass waste, 15mm dia CI body brass spindle stop cock of approved quality of weight not less than 350 grams, 32mm PVC waste pipe 750mm long with brass coupling at one end and making plumber joints etc, all complete as per specification and direction of E/I |
| 96 | Supplying, fitting and fixing 40mm high vitreous white glazed earthen E.W.C with 'P' trap of parry hindusthan or any other approved I.S.S make including supplying and fixing 15 litres CI mosquito proof low down flushing cistern of approved make with complete fittings with C.I handle and R.S or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grams 15mm P.V.C alkathene pipe 45cm long with brass coupling at both ends and white/black plastic solid state seal and lead of commander/cuckoo or other I.S.S make with hinges or screws etc painting pipe and cistern etc with 2 coats of approved paint over a coat of red oxide priming , all complete as per specification and direction of E/I. with 'P' trap, 12.5 lit low level C.I cistern |
| 97 | Supplying, fitting and fixing flat back or angular, lipped front vitreous white glazed earthern ware urinal of Hindusthan \\"Parry\\" or any other approved I.S.S make with litre capacity C.I automatic flushing cistern of reliance for any other I.S.S approved make with all fittings, with CI or RS brackets, standard size GI flush pipe with fitting clamps , 15mm CI body brass spindle stop cock of approved quality weight not less than 400 grams, 15mm PVC/alkathene pipe 450mm long with brass coupling at both ends and doing plumber joints including painting of exposed part with two coats of approved paint over a priming coat of red oxide , cutting wall & floor , making good the same etc as per specification and direction of E/I. Flat back or standing corner (600mm X350mm) |
| 98 | Providing and fixing male ended 15mm dia brass bib cock ofapproved quality (Wt. not less than 350gms.) with extra socket all complete as per specification and direction of E/I. |
| 99 | (b)Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror. |
| 100 | Providing & fixing PVC waste pipe for sink including PVC waste fitting Complete |
| 101 | Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the wall same including testing of joints complete as per the direction of engineer inchargeConcealed work including cutting chases and making good the wall etc.15 mm nominal outer dia pipes |
| 102 | Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. (a) From 0.00 M to 50.00 M below G.L. |
| 103 | Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. (b) From 51.0 M to125.00 M |
| 104 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia |
| 105 | Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \\"V\\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge |
| 106 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia |
| 107 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp |
| 108 | Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump.Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages2 HP |
| 109 | Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes , all complete job as per direction of E/I. |
| 110 | Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I. |
| 111 | Supply fitting and fixing lowering 40 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I. |
| 112 | DT : Basic rates for 125/115mm dia drilled Tube-well for drilling in all kinds of soil and rock for installation of hand pump with DTH rig Machine all complete including supplying all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant, for making 125/115 mm dia boring etc. and cost of transporting rig machine and other vehicle up to site of work as per specification and direction of E/I.. (Basic Rates)Drilling upto 30 mtr. Depth below G.L. in Rural Area |
| 113 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 300 mm dia. R.C.C. pipe |
| 114 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :With 20x20 mm square bar |
| 115 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 75mm |
| 116 | 110mm nominal dia |
| 117 | Single tee without door 110x110x110 |
| 118 | 110 mm dia U-PVC equal Tee (class III, 6kg/sqcm) confirming to IS:7834 (Tee fixing to settler outlet) |
| 119 | SITC GI Sheet .8 mm thick |
| 120 | SITC Alu U beadings |
| 121 | SITC EPDM Rubber (Above 60 G/M ) |
| 122 | SITC GI Fasteners |
| 123 | SITC Door/Polycarbonate sheet door with Alu frame 1 1/2\\" GI Sq pipe of 1.4mm thick |
| 124 | SITC Polycarbonate sheet of 6mm thick Double sided UV coated Transparent sheet |
| 125 | Supply of UPVC piping of following sizes for FSTP installation'Size: 50 mm dia wt. not less than 1.0 kg |
| 126 | Supply of UPVC piping of following sizes for FSTP installation'Size: 40 mm dia wt. not less than 700 gms |
| 127 | Supply of UPVC piping of following sizes for FSTP installation'Size: 100 mm dia wt. not less than 1.80 kg |
| 128 | Providing, fixing, testing and commissioning of Filtration system with Multigrade Sand Filter in FRP construction and comprising of fine and coarse sand, pebbles and gravels as supporting media along with distribution system and all other accessories required to complete the system. |
| 129 | Supply of UPVC piping of following sizes for FSTP installation'Size: 150 mm |
| 130 | Supply of UPVC piping of following sizes for FSTP installation'Size: 100 mm |
| 131 | Supply of UPVC piping of following sizes for FSTP installation'Size: 50 mm |
| 132 | Supply of UPVC piping of following sizes for FSTP installation'Size: 40 mm |
| 133 | BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile RubberSeal & O- Ring PN 16 pressure rating for chilled water/hot eatercirculation as specified'Size: 25 mm |
| 134 | BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile RubberSeal & O- Ring PN 16 pressure rating for chilled water/hot eatercirculation as specified'Size: 40 mm |
| 135 | BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile RubberSeal & O- Ring PN 16 pressure rating for chilled water/hot eatercirculation as specified'Size: 50 mm |
| 136 | BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile RubberSeal & O- Ring PN 16 pressure rating for chilled water/hot eatercirculation as specified'Size: 100 mm |
| 137 | Providing, fixing, testing and commissioning of all fitting.'ELBOW 50MM |
| 138 | Providing, fixing, testing and commissioning of all fitting.'ELBOW 100MM |
| 139 | Providing, fixing, testing and commissioning of all fitting.'ELBOW 150MM |
| 140 | Providing, fixing, testing and commissioning of all fitting.'TEE 50MM |
| 141 | Providing, fixing, testing and commissioning of all fitting.'TEE 100MM |
| 142 | Providing, fixing, testing and commissioning of all fitting.'TEE 150 MM |
| 143 | Providing, fixing, testing and commissioning of all fitting.'SOCKET 50MM |
| 144 | Providing, fixing, testing and commissioning of all fitting.'SOCKET 100MM |
| 145 | Providing, fixing, testing and commissioning of all fitting.'SOCKET 150MM |
| 146 | Providing, fixing, testing and commissioning of Screening constructed from Steel of suitable size for screening out the larger particles from the faecal sludge.Size: 600 mm x 800 mm |
| 147 | Providing, fixing, testing and commissioning of cutter type submersible Pumps for feeding Sludge to Stabilization reactor to Sludge drying bed. The pumps shall be complete with motor and required accessories.Flow: 1.875 m3/hr.@8-10 m head., Power rating 2 HP |
| 148 | Providing, fixing, testing and commissioning of Filter Feed Pumps (Submersible type) in the storage tank. The pumps shall be complete with motor and required accessories.Flow: 1.875 m3/hr.@25-30 m head. Make: WILO/Kirloskar, KOSM -1.540 M |
| 149 | Providing, fixing, testing and commissioning of treated water transfer Pumps. The pumps shall be complete with motor and required accessories.Flow: 1.875 m3/hr.@10-20 m head. Make: WILO/Kirloskar, KDS GMC-123/Eqv. Power rating: 2 HP |
| 150 | Y - STRAINER of Ductile CI Body flanged ends with stainless steel50 mm |
| 151 | Providing, fixing, testing and commissioning of GRA-Filtration system with Activated carbon Filter in FRP construction and comprising of activated carbon and coarse sand, pebbles and gravels as supporting media along with distribution system and all other accessories required to complete the system.Dia- 400 mmHOS: 1625 mm |
| 152 | Providing, fixing, testing and commissioning of Chlorine Dosing with dosing pump and tank. Make: Impel |
| 153 | Providing, fabricating and erecting MS ladder of 450mm wide made of 65 x 65 x 6mm angle iron and 20mm MS bars for walkway to top of the room including cutting, hoistng, fixing in position and applying a priming coat of approved steel primer complete in all respect as per specifications and the direction of the Engineer. |
| 154 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 155 | 160mm nominal dia (CH1 outlet & CH2 inlet) |
| 156 | 160 mm dia U-PVC equal Tee (class III, 6kg/sqcm) confirming to IS:7834 (tee fixing at CH1 outlet & CH2 inlet) |
| 157 | 160mm nominal dia (CH3 inlet pipe) |
| 158 | 160 mm dia U-PVC equal Tee (class III, 6kg/sqcm) confirming to IS:7834 (tee fixing at CH3 pipe) |
| 159 | 160mm nominal dia (CH3 outlet pipe) |
| 160 | 160 mm dia U-PVC double/ single socketed 90° bend (class III, 6kg/sqcm) confirming to IS:7834 ( elbow at vent pipe , perforated pipe) |
| 161 | 160 mm dia U-PVC equal Tee (class III, 6kg/sqcm) confirming to IS:7834 (tee fixing at CH3 outlet pipe) |
| 162 | 110mm nominal dia(vent pipe) |
| 163 | Slotted cowl (terminal guard) 100 mm dia |
| 164 | Slotted cowl (terminal guard) 160 mm dia |
| 165 | Unbranded Plain ended pipe Unplasticized Pvc Pipes For Potable Water Supplies-Is 4985, Length 3 Meter ID ( 5116877-75057965346) |
| 166 | Unbranded PN 16 Commercial UPVC Fittings, Size 1/2\\" - 14\\" TEE (ID 5116877-28301669646) |
| 167 | Unbranded PN 16 Commercial UPVC Fittings, Size 1/2\\" - 14\\"ELBOW.ID (5116877-5114595915) |
| 168 | Single Pipe Clamps SARALR (MS-65)ID ( 5116877-54564818304) |
| 169 | Providing and laying Cinders as a Filter Material In AF as per the instruction given by the site engineer in charge. |
| 170 | Electrical |
| 171 | Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box etc as required. |
| 172 | S/F Piano type switch socket:- Supplying and fixing of following piano type switch /socket on the existing switch box cover including connections etc as required Electronic step fan regulator,deluxe |
| 173 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps one way switch |
| 174 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2x2.5 sq mm + 1x2.5 sq mm earth wire |
| 175 | S/F 'C' series, MCB:- Supplying and fixing following, 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required.40 amps,SPN |
| 176 | G.I. Earth pipe electrode with salt/charcoal: earthing with GI earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal and salt as required. |
| 177 | Ceiling fan 1200mm |
| 178 | S.I.T.C of following rating surface mounted LED Tube Lighting Fitting Suitable for 230V 50 Hz, Single Phase Supply etc. complete as required. (Make:- Havells/Philips/Crompton/Wipro.)20/22 W LED Tube Light |
| 179 | SITC of following rating recess / surface mounted LED round / square shape down light luminarie with pressure die cast housing for single phase supply voltage Luminarie shall be confirm to IS: 10322 part -5 / section -2 or IEC :62722 withh all neccesary accessories as required. (Make:- Havells/Philips/Crompton/Wipro.)12W LED Round Down Light (Recess / Surface ) |
| 180 | Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box etc as required.Group c |
| 181 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps one way switch |
| 182 | Providing, fabricating and erecting MS ladder of 450mm wide made of 65 x 65 x 6mm angle iron and 20mm MS bars for walkway to top of the room including cutting, hoistng, fixing in position and applying a priming coat of approved steel primer complete in all respect as per specifications and the direction of the Engineer.HT. 3.5 MTR |
| 183 | P & F 1.6 mm thick M.S. Recessed fan box, hexagonal/ round of size 100 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . |
| 184 | P & F 18 SWG Sheet steel boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) on surface or in recessed as required. Size: 150 x 75 x 60 mm |
| 185 | Providing, fixing, testing and commissioning of MCC panel and Electrical Accessories for all the feeders of FSTP and associated work to complete the system |
| 186 | 3 Core X 1.5 sq. mm |
| 187 | 3 Core x 2.5 sq. mm |
| 188 | 300 mm Width x 50 mm , 1.6 mm thickness |
| 189 | 100 mm width x 40 mm, 1.6 mm thickness |
| 190 | Supply of 7.0 Mtr High Octagonal pole ( Hot Dip Galvanized) BOP-7030 with top dia 70mm and bottom dia 130mm and made of 2mm thick base plate of size 200mmX200mmX12mm ( LXBXT) and with suitable size of foundation bolts and complete as required |
| 191 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.Above 6.5 metre and upto 8 metre |
| 192 | SITC of following ratings LED Flood lighting luminaire with pressure dia cast housing and toughned glass cover IP 66 protection) in existing pole / pipe for supply voltage 100 ,270v AC , 5o HZ luminaire shall be confirm to IS 10322 part 5/ section 3e and shall be complete with all necessary accessories as required 45W LED STREET LIGHT |
| 193 | G.I. Earth pipe electrode with salt/charcoal: earthing with GI earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal and salt as required. |
| 194 | Silent type, Diesel Generator Set of Capacity 10 KVA three phase with with AFM |
| 195 | Fire exitinguisher set of 3 (Including transportation, excluding taxes) |
| 196 | Cesspool vehicle of Truck Mounted Suction Machine (Gully Emptier), Capacity: 3500 Ltr Suction Hose Length-15mtr minimum. |
| 197 | Electro-Magnetic Flow Meter |
| 198 | SITC 9\\" (230mm) Metal Exhaust fan |
| 199 | SITC 12\\" (300mm) Exhaust fan |
| 200 | SITC 100W Solar PV modules with mounting structure , Automatic Temperature And Humidity Controlling System with all internal Electrical wiring materials |
| 201 | SITC Solar Offgrid Power Plant with accessories 7.5 KVA Offgrid Inverter -3 ph -1 no 150 AH Solar battery - 8 nos 545W Solar Pv module-14nos Mounting structure - 1set |
| 202 | Engineering, Supply Installation, Testing & Commissioning of 21.8kW Solar On Grid System power plant SOLAR MODULE 545Wp Solar MonoPERC, 144 cells module SOLAR ON GRID INVERTER Enviro GTi 24 KT - NG DC DISTRIBUTION BOX DCDB 4 In 4 Out with Fuse AC DISTRIBUTION BOX 1X63A IN/OUT CABLE SOLAR MODULE TO INVERTER 1C, 4 sqmm Solar DC cable- (Black & Red) INVERTER TO ACDB 4 C X 25 Sq mm, Aluminium Conductor, XLPE Insulated, armoured ACDB TO LT PANEL 3.5 C X25 Sq mm Al conductor, XLPE insulated, Armoured Cables EARTHING SYSTEM FOR STRCUTRE, INVERTER, ACDB GI Strip 25x5 mm for Module Mounting Structure 1C X 50sqmm, Copper Cable EARTHING PIT- Copper Bonded Earth Rods - 3 Mtr + 25 Kg bag Back Fill Compound LIGHTNING ARRESTOR Conventional Lightning Protection System 1C X 70sqmm, Copper Cable GI Strip 25x5 mm MODULE MOUNTING STRUCTURE Mono Rail type shed structure CONDUIT/ CABLE TRAY HDPE Conduit 40 mm (DC Cable interconnections) NormalPerforated type Cable trays -with Cover 1.2 Pre Galvanised MODULE CLEANING ARRANGMENT Cleaning arrangement accessories & 1 hp mini water pump single phase with water pressure boostinG Net Metering (If Applicable) |
| 203 | 1000 Mm X 600 Mm X 750 Mm Unbranded Computer Table consists of Computer table with key board drawer and table top ID (5116877-26677851254) |
| 204 | Revolving Chair with Only Revolving without tilting mechanism (5116877-34440031805) |
| 205 | Nilkamal Plastic Moulded Chair With Arms Without Cushion Single Piece Plastic Moulded ID ( 5116877-99333142954) |
| 206 | office seating collection Almirah Steel shelving cabinets ID(5116877-86269445252) |
| 207 | Providing operation & maintenance of truck/sucking machine i.e., that includes regular repairs and maintenance, operations, human resource cost and other activities. |
| 208 | Annual Cost (Year-1) |
| 209 | Year-2 Cost |
| 210 | Year-3 Cost |
| 211 | Year-4 Cost |
| 212 | Year-5 Cos |
| 213 | GST @ 18% |
| 214 | Labour cess @1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysOct 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender