Tender For special Repair To Bldg No Eb-14 (Ration Fresh Store / Documentation Cell) Of Demo Bn, anganwadi center Under Ge anganwadi center Mhow
Tender Value
43.70 Lakhs
Estimated cost
Bid Submission
28 Oct 2026
1 days left
EMD
87400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Indore → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair To Bldg No Eb-14 (Ration Fresh Store / Documentation Cell) Of Demo Bn, anganwadi center Under Ge anganwadi center Mhow
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of plain or corrugated steel sheeting any gauge, thickness, including nainital or similar pattern roof coverings. |
| 2 | S&F Pre-painted galvalume aluminium zinc coating GI based profile steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa, hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) as in roof covering/ cladding to wall,including flashings , ridges, valley etc fixed with self tapping screws as specified and directed |
| 3 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa, hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) as in roof covering/ cladding to wall, fixed with self tapping screws as specified and directed. |
| 4 | Dismantling of timber scantling as fillets, rails, posts, rafters, purlins, any section & any description complete all as specified and as directed. |
| 5 | M&L for MS framed structure roof trusses (framed), trussed, purlins, crane gantries and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats of Grade Fe 410 -W (Gde- E-160 ) quality- A etc. complete all as specified and directed. |
| 6 | Demolition of un-reinforced Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specifed and directed. |
| 7 | Demolition of cement concrete (reinforced) as in roof, floors (other than ground floor) beams, staircase, landing, chajjas and similar suspended work complete all as specifed and directed. |
| 8 | Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) and rubbish of the premises complete all as specified and directed. |
| 9 | M & L for Vitrified Ceramic tiles 600x1200x8to10 mm thick (square/ rectangular) polished, in floors etc.including 15mm thick cement mortar screed bed 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 10 | M&L for Non-skid coloured ceramic joint free tiles 7 to 8mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.36sqm in floors, skirting, Dados etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tile complete all as specified and as directed. |
| 11 | S&F Glazed ceramic tiles in vertical surface 450 x 350x 7 mm thick ,including 10 mm thick screed bed set and jointed in neat cement slurry and pointed in white or ocloured cement complete all as specified and as directed. Note : Rate includes for cutting for offsets etc) complete all as specified and as directed. |
| 12 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and directed |
| 13 | M & L 20 - 25 mm thick machine cut Kota stone slab in flooring or treads of steps over and including 20mm thick screed bed in cement mortar 1:6, laid and jointed with grey cement slurry mixed with pigment to match with shade of slab including rubbing complete all as specified and as directed. Note:- The size of Kota stone slab shall not less than 550 mm x 550 mm cut size, except the location where the balance portion remain less than size as specified above. |
| 14 | Description same as per item No 13.00 above but as in skirting or vertical surfaces including 10 mm thick rendering in cement mortar 1:4, complete all as specified and as directed. |
| 15 | M&L for granite slabs 20mm thick machine cut bedded laid over cement screed 15mm thick in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of slab incl grinding moulding rounding chamfering and polishing complete all as specifed and directed. |
| 16 | M&L for Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed. |
| 17 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillet complete all as specifed and directed. |
| 18 | Providing and fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum ) False ceiling tiles of size 595 x 595 mm of approved texture, design and patterns having moisture contents less than 2% humidity resistance of 99% NRCO.50 to .75 as pe IS8225:1987, Noncombustible as per BS 476 (Part 4)-1970 and light reflectance of 85% (Minimum) to be laid in true horizontal level suspended on interlocking metal T Grid of hot dipped galvanized iron section of 0.33 mm thick ( galvanised @ 120 gms per sqm including both sides ) comprising of main T runners of size 15 x 32 mm of length 3000mm, cross -T of size 15 x 32 mm of length 600mm to form grid module of size 600 x 600mm, suspened from ceiling using galvaized mild steel items ( galvanizing @ 80 grams per sqm) i..e 50mm long, 8mm outer diameter M-6 dash fastener 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25 x 2mm galvanised iron permieter wall angle of size 24 x 24 x 0.40mm of length 3000mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450 mm ceneter to centre and 50mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions. |
| 19 | Surface dressing n.exc 30 cm deep in soft/loose soil all as specified and directed. |
| 20 | M&L for morum filling/redbajri filling under floors or in foundations including watering &consoldation laid in layers n.exc 15 cm thick spread levelled and well rammed all as directed by Engr-in-Charge |
| 21 | M&L for 75mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in plinth protection finishing the surface even and smooth without using extra cement. |
| 22 | M&L for 100 mm thick cement concrete type D-2, 1:4:8 (40mm graded agg) as in Sub-base to floor finishes. |
| 23 | Material and Labour Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-40 grade conforiming to IS 15658:2006 with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specifed and directed. |
| 24 | M&L for Pre Cast Cement Concrete 1:2:4 type B1 (using 20 mm graded aggregate) as in Kitchen platform and Cover slab for manholes etc set in cement mortar 1:4 including use and waste necessary form work reinforcement shall be measured and paid separately all as specefied & directed. |
| 25 | M&L for mild steel TMT bars 10mm dia and over, cut to length bent to shap required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed not less than 0.9 mm dia or securing with clips complete all as specifed and directed. |
| 26 | Description all as per ser item No. 25.00 herein before but 5mm dia and over upto and incl 10 mm dia in spacers, stirrups and binders complete all as specifed and directed. |
| 27 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. |
| 28 | M & L for brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 29 | M&L for brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1: 4 complete all as specified and directed. |
| 30 | Taking down cement plaster on wall of any description incl racking out joints for key, scrubbing with water etc. complete all as specified and directed. |
| 31 | M & L for rendering 15mm thick in cement mortar 1:4 on concrete or brick wall surfaces, finished even and smooth without using extra cement, mixed with WPC @ at 3% by weight of cement (WPC measured and paid separately) complete all as specified and directed. |
| 32 | Supply only integral water proofing compound. |
| 33 | M & L for rendering 10mm thick in cement mortar 1:6 on Brick wall surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 34 | M&L for 15 mm thick cement plaster in cement mortar 1:6 on brick or concrete surface etc. on wall finished even and smooth without using extra cement, all as specified . |
| 35 | M&L for PCC type D2 1:4:8 (using 40mm graded stone aggregate) as in foundations, filling and mass Concrete complete all as specified and directed. |
| 36 | Taking down chowkats with shutters (without taking off shutters from the frame exc 1.5 Sqm and n.exc 4 Sqm each complete all as specifed and directed. |
| 37 | Description all as per ser item No. 36.00 above in before but area n exc 1.5 Sqm complete all as specifed and directed. |
| 38 | S&F Pressed steel frames 125x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete all as specifed and directed. |
| 39 | S&F pressed steel door frames of size 105 x 60mm, made of 1.25mm thick sheet, for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified as directed. |
| 40 | S&F IInd class hardwood panelled shutters of 40mm thick (any number of panels) with panels of timber flat on both sides (feathered edged or of veneered particle board medium density, wood particle board with commercial face veneers, complete all as specified and as directed. |
| 41 | S&F 30mm thick locally fabricated 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.20 (a) fitted to chowkhats complete all as specified and as directed. |
| 42 | S&F of Harrison rails (Curtain rails) of anodised aluminium alloy chromium with fixing brackets stops, rollers etc complete all as specified and as directed. |
| 43 | Material and labour Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed withn wooden beading or with nuts and bolts to existing steel windows/wooden windows complete all as specifed and directed. |
| 44 | S & F UPVC sliding glazed windows with three track shutter sliding (two shutters glazed and one shutter wire mesh) shall be following specification complete all as specified and as directed.(i) Windows frame of cross section 101mm x 44mm x 1.5mm thick.(ii) Three way track for sliding shutters of cross section 91.8mm x 31.75mm x1.1mm thick.(iii) Sliding shutter frame of cross section 40 x 18 x 1mm thick.(iv) 4 mm thick tinted glass superior quality.(v) IDPE Rubber guasket for fixing of glass.(vi) Locking cleats per shutter -01 Nos.(vii) Sliding rollers per shutter - 02 Nos.including satety steel grill(viii) Aluminium wire cloth 0.30mm nominal dia of wire and average width of aperture 1.56mm for shutters 01 Nos. |
| 45 | S&F 300mm length, aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy. |
| 46 | S&F 250 mm length, aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy. |
| 47 | S&F 100 mm size of Butt hinges, medium weight cold rolled mild steel complete door etc |
| 48 | S&F aluminium anodised barrel tower bolts of extruded section with 200 mm long bolt, all as specified . |
| 49 | S&F Extruded aluminium alloy handles fabricated type anodised 150mm size complete all as directed and specifiedand as directed. |
| 50 | S&F Extruded aluminium alloy handles fabricated type anodised 100mm size complete all as directed and specified and as directed. |
| 51 | M&L for floor door stopper of brass body and tongue, anodised, with hard drawn steel spring, 140mm long, fixed in floor complete all as specified & as directed. |
| 52 | M & L for preparation of newly untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 53 | Material and labour Preparation new or old painted wooden surfaces of any description over 10 cms width or girth not otherwise described and applying one coat of synthetic enamel paint . |
| 54 | M&L for preparation of old plastered surfaces and applying two coat Acrylic emulsion distemper with roller over applying minimum 1mm thick white wall care putty over prepared surface to achieve the surface even and smooth for painting complete all as specified and directed (Note:-Contractor shall furnish gaurantee of four year against service rendered) (Note:- primer and emulsion paint shall be carred out through air less spray machine (Mechanical means) |
| 55 | Material and Labour for applying Two coats of 100% Premium exterior acrylic emulsion paint over applyng 1 mm thick white wall care putty latex based having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of equired shade (Company Depot Tinted) with silicon additives @ 1.43 liter/10 sqmover and including priming coat of exterior primer applied @ 0.90 litre/10sqm Note- (i) contractor shall furnished guarantee four years againts service rendered) (ii) primer and emulsion tobe carred out through air less spray machine (mechanical means) |
| 56 | Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site. |
| 57 | Taking down ceiling fan/ exhaust fan/ wall fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M complete all as specified and as directed. |
| 58 | Taking down regulator , sealing cable ends and removing regulator to store |
| 59 | Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. |
| 60 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed. |
| 61 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :- |
| 62 | (a) One light point controlled by one, one way switch 5 Amps |
| 63 | (b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator |
| 64 | (c) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 65 | (d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board. |
| 66 | Description all as per item No 61.00 here in before but using 2.5 sq mm single core copper conductor cable of multistranded FRLS PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor FRLS PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 67 | S & F for Modular Switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified. |
| 68 | S & F for Modular Switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified. |
| 69 | S & F for Modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 70 | S & F for Modular Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 71 | S & F for modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed. |
| 72 | S & F for Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified |
| 73 | S & F for sheet metal enclosure MCB DB TPN 4 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 74 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit |
| 75 | S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25/35 watts with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed. |
| 76 | S & F for LED luminaire 600 mm x 600 mm square LED panel 35/36 watts, 220 volts, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling, including connecting up with driver three core flexible copper conductor cases of suitable size complete all as directed. |
| 77 | S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 78 | S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 79 | S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 80 | S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 81 | S & F for ceiling fan, 230 Volts, 50Hz, 1200 mm sweep with down rod, canopy, blades, BLDC motor etc and service value of the fan shall be greater than 6.1 as per BIS with necessary accessories and electrical connections from ceiling rose to fan terminal including writing the MES Number with synthetic enamel paint complete all as specified and as directed. |
| 82 | S & F for PVC non-metallic rigid conduit ISI marked heavy duty white/ Ivory colour and its accessories heavy duty ISI marked of size 40 mm dia for LAN, telephone and TV connections including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed. Please Enable Macros to View BoQ information |
| 83 | S & F for PVC non-metallic rigid conduit ISI marked heavy duty white/ Ivory colour and its accessories heavy duty ISI marked of size 40 mm dia for LAN, telephone and TV connections including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayOct 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender