Tender For Augmentation Of Existing Switchgear And Providing Dg Set Supply Switchgear In Old Hostel Block In Post Graduate Govt. College For Girls, Sector 42, Chandigarh.
Tender Value
26.94 Lakhs
Estimated cost
Bid Submission
14 Oct 2026
7 days left
EMD
53900
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Augmentation Of Existing Switchgear And Providing Dg Set Supply Switchgear In Old Hostel Block In Post Graduate Govt. College For Girls, Sector 42, Chandigarh.
BOQ
| Sl. No. | Item Description |
| 1 | DSR item No.1.17 Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 2 | 3 x 4 sq.mm |
| 3 | 5 x 6 sq.mm |
| 4 | DSR 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 5 | DSR item No.2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 6 | 100 A,30KA,FPMCCB |
| 7 | 250 A,36KA,FPMCCB |
| 8 | 400 A,50KA,FPMCCB |
| 9 | DSR 2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 10 | 6 way, Double door |
| 11 | DSR Item No. 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without (MCB/RCCB/Isolator) |
| 12 | 4 way (4 + 12), Double door |
| 13 | DSR Item No.2.5 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required). |
| 14 | 8 way (4 + 24), Double door |
| 15 | 12 way (4 + 36), Double door |
| 16 | DSR 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 17 | Single pole |
| 18 | Double pole |
| 19 | Triple Pole |
| 20 | Triple pole and neutral |
| 21 | DSR item No.4.1 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastner etc as required. |
| 22 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 23 | DSR item No.4.2 Supplying and installation following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required. |
| 24 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 25 | DSR item No.4.3 Supplying and installation following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastner etc as required. |
| 26 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 27 | DSR 5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 28 | DSR item No.5.12 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 29 | DSR 11.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 30 | 4 X 10 Sq mm (25 mm) |
| 31 | 3 ½ x 95 Sq mm ( 45 mm) |
| 32 | 3 ½ x 185 Sq mm ( 57 mm) |
| 33 | DSR item No.15.15 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 34 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 35 | DSR item No.15.16 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 36 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 37 | Supply and erection of sheet metal bus-bar chamber on existing surface with required No. of bus-bar strips of suitable length and cross-sectional area, made of copper strips of suitable length and cross-sectional area enclosure made of M.S. sheet 1.6mm thick with detachable cover fitted with dust excluding gasket and secured with sufficient No. of cadmium plated iron screws and of given overall dimensions and to be fixed with G.I. bolts and nuts/Rag bolts and nuts etc., complete with all accessories including connections with suitable size tin coated copper thimbles, bonding to the existing earth and painting etc. as desired by the Engineer-in-charge. |
| 38 | Sheet metal bus-bar chamber suitable for 300 Amp. 2’ long 415 Volts capacity with 4 copper strip Bus-bars each of length 600 mm & cross-sectional area (31.75 x 6.35mm) enclosure having overall dimensions (680mm x 500mm x 200mm) nominal. |
| 39 | Supply and laying of XLPE insulated PVC sheathed Aluminum conductor armoured cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid in existing Trench/Ducts/Cable Tray/ RCC/ HUME/ METAL/ DWC pipe / on surface with the help of MS clamps of suitable size/ as required at site to the entire satisfaction of Engineer-in-Charge. The job includes labour charges of laying the cable and making connections with suitable size aluminum lugs/thimbles etc. The cable shall be of Polycab / Havells / R.R. Kabel/ KEI/ Finolex make only. |
| 40 | 185 sq.mm 3.5 core (In pipe) |
| 41 | 95 sq.mm 3.5 core (On surface) |
| 42 | 10 sq.mm 4 core (On surface) |
| 43 | Making of Haudi of following size for drawing of underground cable etc constructed with bricks wall 9” thick and plastered 12 mm thick from the inner side with Cement Plaster of mix: 1:4 (1 cement: 4 fine sand). The RCC cover moulded in an angle frame of size 35mm x 35mm x 5mm should be provided above the Haudi which should rest on 40mm x 40mm x 5mm angle iron frame fixed on the upper portion of the Haudi. The cover should be provided with lifting arrangement. The rate includes all labour and material to complete the job to the entire satisfaction of Engineer-in-Charge. |
| 44 | Size 2’ x 2’ x 2’ deep |
| 45 | Supply and erection of sheet metal cubical pedestal of suitable dimensions made from 50 mm X 50 mm X 6 mm thick M.S angle iron frame, covered with 1.6 mm thick M.S. sheet duly welded on five sides and front side hinged complete with locking arrangement with 4 Nos. switchgear supporting members each of M.S. flat 50 mm X 6 mm thick of suitable length duly welded. The cubical pedestal shall have 4 Nos. legs of 50 mm X 50 mm X 6 mm each 60 cm long M.S. angle iron each long including painting, bonding to the existing earth etc. the same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15cm high form ground level and 45 mm thick. The cubical pedestal shall be 15 cm from the top of cement concrete platform. |
| 46 | Cubical size 1200 mm X 900 mm X 350 mm |
| 47 | Fabrication, supplying, installation, testing and commissioning of Indoor type cubicle type fully enclosed compartmentalized electric panel of suitable size (300mm-900mm) deep as required as site suitable for three phase 50 Hz 415 volt AC supply system made out of 1.6 mm thick CRCA sheet duly strong thread with suitable size of MS channel members and base weather proof dust and vermin proof, ventilated with louvers at sides removable gland plates at the bottom, earthing studs at both ends duly painted with powder coated finish of approved shade and two coats of anticorrosion paint including providing and fixing of four strip main and auxiliary aluminium bus bars of rating min 300 amp., multifunction meter, LT phase indicator lamp for each incomer/ outgoing, MCB distribution board metering unit and having space for accommodating various MCCB’s, MCB SP, MCB TPN, Change over switch etc as per site requirement. The manufacturer/ fabricator of LT panel should posse’s type test certificate/ reports w.r.t. construction/ manufacturing of LT panel confirming to IS: 8623/93 with breaking capacity 50KA (minimum) & Degree of protection IP42 (minimum) from CPRI /ERDA approved Lab. |
| 48 | Fabrication, supplying, installation, testing and commissioning of Indoor type cubicle type fully enclosed compartmentalized electric panel of suitable size (300mm-900mm) deep as required as site suitable for three phase 50 Hz 415 volt AC supply system made out of 1.6 mm thick CRCA sheet duly strong thread with suitable size of MS channel members and base weather proof dust and vermin proof, ventilated with louvers at sides removable gland plates at the bottom, earthing studs at both ends duly painted with powder coated finish of approved shade and two coats of anticorrosion paint including providing and fixing of four strip main and auxiliary aluminium bus bars of rating min 600 amp., multifunction meter, LT phase indicator lamp for each incomer/ outgoing, MCB distribution board metering unit and having space for accommodating various MCCB’s, MCB SP, MCB TPN, Change over switch etc as per site requirement. The manufacturer/ fabricator of LT panel should posse’s type test certificate/ reports w.r.t. construction/ manufacturing of LT panel confirming to IS: 8623/93 with breaking capacity 50KA (minimum) & Degree of protection IP42 (minimum) from CPRI /ERDA approved Lab. |
| 49 | Labour charges for horizontal boring by mechanical means (hydraulic excavator)/ manual means 1 Meter below the ground level for laying of DWC Pipe including cost of 2 nos. Pit digging and refilling, disposal earth to be leveled and neatly dressed complete in all respects to entire satisfaction of the Engineer in Charge of the work. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysOct 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender