Housing Urban and Rular Development Government Departments Closing in 18 days TDR #57883175

Tender For Execution Of Basic Works Proposed Under Parishistha A Of Conservation And Development Plan For The Punyashlok Ahilyadevi Holkar Memorial Site At Choundi Village Tal.Jamkhed Dist.Ahilyanagar (Construction Of River Bank Ghat, Internal Roads,

Issued by Government Departments · Ahmednagar, Maharashtra
Tender Value
126.37 Crore
Estimated cost
Bid Submission
26 Oct 2026
18 days left
EMD
63.19 Lakhs
Bank guarantee accepted
Document Fee
3540
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ahmednagar → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Execution Of Basic Works Proposed Under Parishistha A Of Conservation And Development Plan For The Punyashlok Ahilyadevi Holkar Memorial Site At Choundi Village Tal.Jamkhed Dist.Ahilyanagar (Construction Of River Bank Ghat, Internal Roads, Compound Wall, Enternace Gates, Exibition Block, Green Room, Helipad, Toilets Block & Electricals Work Etc.) And Providing Electrical Installation For Punyashlok Ahilyadevi Holkar Memorial At Chondi, Tal. Jamkhed, Dist. Ahilyanagar[ Part-A To H]

BOQ

Name of Work:- EXECUTION OF BASIC WORKS PROPOSED UNDER PARISHISTHA A OF CONSERVATION AND DEVELOPMENT PLAN FOR THE PUNYASHLOK AHILYADEVI HOLKAR MEMORIAL SITE AT CHOUNDI VILLAGE TAL.JAMKHED DIST.AHILYANAGAR (CONSTRUCTION OF RIVER BANK GHAT, INTERNAL ROADS, COMPOUND WALL, ENTERNACE GATES, EXIBITION BLOCK, GREEN ROOM, HELIPAD, TOILETS BLOCK & ELECTRICALS WORK ETC.) AND Providing Electrical Installation for Punyashlok Ahilyadevi Holkar Memorial at Chondi, Tal. Jamkhed, Dist. Ahilyanagar[ PART-A To H]
Sl. No. Item Description
1Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means
2Providing and laying cast in situ / Ready Mix Cement Concrete M-25 for single rim bored pile of 450 mm dia. each of load capacity as per design and of specified diameter of pile and bulb as directed, sunk to the required depth through all strata except rock,excluding provision of reinforcement including placing with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) by tremie arrangement compaction of concrete including chipping and dressing etc. complete. (Excluding steel reinforcement)
3Empty boring for 425 to 500 mm dia. bored R.C.C. cast in situ piles including withdrawal of shell, removal of earth to a distance of 50 metres etc. complete. Spec :(As directed by Engineer in Charge)
4Chipping and dressing of the R.C.C. piles upto 0.60 meterincluding cleaning reinforcement and removal of dismantled materials upto a distance of 50 meter beyond the building area etc. for providing pile caps. Spec :(As directed by Engineer in Charge
5Providing bentonite slurry process for various diameter of piles vide Item Nos 1 (i to xxiv) above. Spec : (As directed by Engineer in Charge)
6Chiseling through pile shells in hard strata like boulders, soft and hard rocks Upto and inclusive of 550 mm diameter including removing and stacking the loose materials etc. complete and disposing of the unserviceable materials outside complete.
7Providing placing and Driving in position 6 millimeter mild steel liner for R.C.C. Piles upto required depth with 12mm thick mild steel cutting edge of 0.50m length at bottom including fabricating cutting the mild steel sheet to required diameter and shape ,welding the joints and driving with the help of required machineries including all materials labours and lifts etc. complete as directed by the Engineer in charge. Upto 3.00 meter deep liner
8Providing placing and Driving in position 6 millimeter mild steel liner for R.C.C. Piles upto required depth with 12mm thick mild steel cutting edge of 0.50m length at bottom including fabricating cutting the mild steel sheet to required diameter and shape ,welding the joints and driving with the help of required machineries including all materials labours and lifts etc. complete as directed by the Engineer in charge. Spec :(As directed by Engineer in Charge From 3.00 to 9.50 meter deep liner
9Carrying out load test for 1.5 times the proposed safe working load on the pile in driven position upto 400 mm diameter including construction of test cap, use of accessories and instruments including providing graphs as per I.S. code or Std.Specifications and dismantling the test cap after testing and cleaning the site complete.
10Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap metal for R.C.C. pile caps as per detailed designs and drawings, including bailing out water manually, centering, formwork, laying/ pumping, compacting, finishing and curing etc. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.with Crushed sand VSI Grade/V.S.I. quality Artificial Sand, complete. (Excluding steel reinforcement)
11Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) ( GROUND FLOOR )
12( GROUND FLOOR )
13Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete.
14Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete.
15Conveyance of material/debris at a distance of 10 Km as directed by the Engineer-In-Charge. ( GROUND FLOOR )
16Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) ( GROUND FLOOR )
17( FIRST FLOOR )
18( TERRACE FLOOR )
19( SECOND FLOOR )
20( THIRD FLOOR )
21( TERRACE FLOOR )
22Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) ( GROUND FLOOR )
23( FIRST FLOOR )
24( TERRACE FLOOR )
25( SECOND FLOOR )
26( THIRD FLOOR )
27( TERRACE FLOOR )
28Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)( GROUND FLOOR )
29( FIRST FLOOR )
30M-25 for R.C.C. Chajjawith Crushed Sand V.S.I. Grade
31Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) ( GROUND FLOOR )
32( FIRST FLOOR )
33Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) ( GROUND FLOOR )
34( FIRST FLOOR )
35( TERRACE FLOOR )
36( TERRACE FLOOR )
37( SECOND FLOOR )
38( THIRD FLOOR )
39( TERRACE FLOOR )
40Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) ( GROUND FLOOR )
41( FIRST FLOOR )
42( TERRACE FLOOR )
43( TERRACE FLOOR )
44Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. ( GROUND FLOOR )
45( FIRST FLOOR )
46( TERRACE FLOOR )
47( TERRACE FLOOR )
48( SECOND FLOOR )
49( THIRD FLOOR )
50( THIRD FLOOR )
51Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per One Square Metre of surface area covering ten years guarantee on bond paper.
52Providing preconstructional antitermite treatment as per I.S. 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 C.M. diametre about 30 -60 cm deep at 15 cm c/c as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper. ( GROUND FLOOR )
53Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. ( GROUND FLOOR )
54( FIRST FLOOR )
55Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. ( GROUND FLOOR )
56( FIRST FLOOR )
57Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. ( TERRACE FLOOR )
58( TERRACE FLOOR )
59( TERRACE FLOOR )
60( TERRACE FLOOR )
61Providing and applying a base coat comprising of 1KilogramPolydee-MC and 1Kilogramfresh cement after wetting the surface followed by drying the surface for 2 days, apply primer coat of TP-40 and after drying, applying Polydee-11 two component (mixing ratio 2 A : 1 B) ) Antibacterial food grade coating inside drinking water tank in two coats with time interval of minimum 8 hrs. covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete. ( GROUND FLOOR )
62(TERRACE FLOOR )
63(TERRACE FLOOR )
64Providing 38 cm thick Composite masonary with 23 centimeter thick ashlar fine tooled /close punched/chisel dressed masonary of approved source and quality of trap/granite/quartzite/gneiss stones of size (0.45m (L) x 0.30m (H) and minimum thickness of 0.23m) in cement mortar 1: 6 in superstructure including striking joints watering and scaffolding complete for facing and 15 centimeter thick Autoclaved Areated Concrete Blocks of Ecolite or equivalent make of size (600x150x150)mm in masonry in extra fine jointing mortar of fixoblock of UltraTech or equivalent for backing including 2mm sunk pointing nessesary through stone and proper interlocking as shown in drawing, in superstructure including striking joints, raking out joints, watering including all lead and lifts etc Complete. Specification: As Directed by Engineer In Charge. ( GROUND FLOOR )
65( FIRST FLOOR )
66(TERRACE FLOOR )
67( SECOND FLOOR )
68( THIRD FLOOR )
69( TERRACE FLOOR )
70Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) ( GROUND FLOOR )
71( FIRST FLOOR )
72Providing and laying damp proof course 50 mm thick in M20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork etc. complete. ( GROUND FLOOR )
73( FIRST FLOOR )
74Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. ( GROUND FLOOR )( With Artifitial Sand usded. )
75( FIRST FLOOR )( With Artifitial Sand usded. )
76(TERRACE FLOOR )( With Artifitial Sand usded. )
77( SECOND FLOOR )( With Artifitial Sand usded. )
78Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete. ( GROUND FLOOR )
79( TERRACE FLOOR )
80( TERRACE FLOOR )
81Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. ( GROUND FLOOR )( With Artifitial Sand usded. )
82( FIRST FLOOR )( With Artifitial Sand usded. )
83( TERRACE FLOOR )( With Artifitial Sand usded. )
84( TERRACE FLOOR )( With Artifitial Sand usded. )
85Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. ( GROUND FLOOR )
86( FIRST FLOOR )
87( TERRACE FLOOR )
88( SECOND FLOOR )
89( THIRD FLOOR )
90Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. ( GROUND FLOOR )
91( FIRST FLOOR )
92( TERRACE FLOOR )
93( SECOND FLOOR )
94Providing and applying plaster with plaster of paris in 6mm thickness to previously plaster surface in all position including preparing the surface scaffolding etc. complete. ( GROUND FLOOR )
95( FIRST FLOOR )
96( TERRACE FLOOR )
97( SECOND FLOOR )
98Teakwood in kadipat ceiling, wall cladding, flooring: Providing and fixing Ist quality (Superior Quality) Teakwood in kadipat ceiling, wall cladding, flooring or any other wooden members etc. including removing damage/decayed wood members, fixing stainless steel screws, cutting, sawing, making groove, making rounding on edges if required, making proper wood jonery, scaffolding if necessary all iron work and applying one coat of primer or as directed by Enginner Incharge etc. complete. For wood size = 4 ^ prime prime *1.5^ prime prime to 8 \\"*1.5\\" ( GROUND FLOOR )
99( FIRST FLOOR )
100Providing and applying Royale Luxury Emulsion of approved make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. wall primer with brush by adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dry for 6 to 8 hoursAfter applying acrylic wall putty with appropriate prpportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45% or 65 to 70 % by roller. (With prior approval of S.E.) ( GROUND FLOOR )
101( FIRST FLOOR )
102( TERRACE FLOOR )
103( SECOND FLOOR )
104Providing and applying colour-wash of approved colour and shade in one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc. complete. ( GROUND FLOOR )
105( FIRST FLOOR )
106( TERRACE FLOOR )
107Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item One Number 15 to 18 prior approval of Superintending Engineer will be necessary ( GROUND FLOOR )
108( FIRST FLOOR )
109( TERRACE FLOOR )
110Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. ( GROUND FLOOR )
111( FIRST FLOOR )
112Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. ( GROUND FLOOR )
113( GROUND FLOOR )
114( FIRST FLOOR )
115( TERRACE FLOOR )
116Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete.
117Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. ( GROUND FLOOR )
118( FIRST FLOOR )
119Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. ( GROUND FLOOR )
120( FIRST FLOOR )
121Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete. ( GROUND FLOOR )
122( FIRST FLOOR )
123Providing and fixing UPVC window system (wallnut Colour) high-quality uPVC profiles with outer frame and outward sash, both in wallnut colour for a clean, modern aesthetic. The system is designed to enhanced durability and security with reinforced profiles and various locking and handle options.Outer Frame: The CMT (casement) outer frame measures 60 mm x 56 mm.A 36.4 mm x 60 mm hurricane bar is included for additional wind resistance.Reinforced with steel inserts for extra structural strength.Casement Sash: outward sash is sized at 60 mm × 75 רות ideal for outward-opening configurations. Reinforced with steel inserts for superior strength.Mullion: T-Mullion with dimensions of 60 mm × 74 mm ensures secure division of window panels including guard bar of 12mm dia 150c/c round solid bar with powder coating to ensure long-term structural stability.Locking Mechanism: The window system offers multi-point locking options for maximum security. Glass 5mm thikness clear glass with edge polish.Handles: White handles are keyless for simpler operation. ( GROUND FLOOR )
124( FIRST FLOOR )
125( TERRACE FLOOR )
126Providing and fixing ventilator wallnut colour high-quality uPVC profiles with outer frame and outward sash, both in wallnut color for a clean, modern aesthetic that complements architectural styles The system is designed to enhanced durability and security with reinforced profiles and various locking and handle options.Outer Dimensions: Casement Outer dimensions of 60MM x56MM, Reinforced with steel inserts specifically designed offering additional strength and support for the overall structure.Mullion: T Mullion features dimensions of 60MM x 74MM rigid frame including guard bar of 12mm dia 150c/c round solid bar with powder coating enhanced reinforcement for the mullion section. ( GROUND FLOOR )
127( FIRST FLOOR )
128Providing and fixing Country cut teak wood double or single leaf second class fully panelled door shutter with 35mm thick style and rail with 25 mm thick panels with openable fan light as per detailed drawings. Excluding the door frame 60mm x 100mm stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats. (Excluding the door frame) ( GROUND FLOOR )
129( FIRST FLOOR )
130( TERRACE FLOOR )
131Providing and Fixing 30 MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and, size 19 x 19 mm for styles and 15 x15 mm for the top and bottom rails, M.S frame shall have a coat of metel primer of approved make and manufacture. M.S frame shall be covered with heat mouled PVC 'C' channel made from 5 mm (+/0.25) thick prelaminated sheet of density 600 Kilogram/cbm ,of size 30mm thickness 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side forming stiles ; and 5 mm thick ,95 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered in 45 on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 mm (+/0.25) thick PVC strip of 20 mm width is to be stuck on the bottom side of the ' c ' channel prelaminated paneling of 5 mm (+/0.25) thick PVC sheet to be fitted inside the M.S. frame welded/ sealed to the styles and rails with 5 mm (+/0.25) x 30 mm PVC sheet beading on either side and joined together with solvent cement adhesive etc ,10 mm thickness (5 mm (+/0.25) x 2 nos ) 20 mm wide cross PVC sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos M.S.powder coated but hinges of size 100 mm x 25MM x 2mm using 32 mm long steel screws drilled suitable to pass through both the walls of the M.S tube. Other hardwares ( GROUND FLOOR )
132( FIRST FLOOR )
133Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. ( GROUND FLOOR )
134( FIRST FLOOR )
135( TERRACE FLOOR )
136Providing and preparing kitchen otta up to 75 cm width,made up from 30 mm thick and 75 cm high vertical support for kadppa at 1 m. c/c of 25 mm thick both side polished kadappa middle shelf and bottom of 20 mm thick one side polished kadappa with facia patti of 20 x 50 mm kadappa including all material labour cutting fixing with cement mortar and araldite curing polished and cleaning etc. complete. ( GROUND FLOOR )
137( FIRST FLOOR )
138Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. ( GROUND FLOOR )
139( FIRST FLOOR )
140( TERRACE FLOOR )
141Providing ad applying Heritage Flakes Plaster to imitate traditional stonework of size 450mmX300mm or plane in elevation with break joint and 3mm thick joints with top matte coat including ceramic flakes, Special glue required, cleaning, scaffolding, etc, complete. ( GROUND FLOOR )
142( FIRST FLOOR )
143( TERRACE FLOOR )
144Atrium roof - Fabrication of the Structure for Atrium Sky Light. Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates, etcetera . as per detailed design and drawing or as directed by Engineer-incharge including cutting, fabricating, hoisting, erecting and fixing in position, making riveted / bolted / welded connections and one coat of anticorrosive paint and over it two coats of oil painting, etcetera . complete. (Bd-C-8/278) Providing and Fixing 13.52millimetre clear laminated tempered glass made of two layers 6millimetre tempered glass of brand Saint Gobain or equivalent, permanently bonded together with 1.52millimetre transparent PVB interlayer under a controlled, highly pressurized and industrial heating process. (6+1.52+6 toughened laminate glass) with Anodised Aluminium backing strip and Pressure tape with weather silicone sealant for the skylight including transportation, lifting and hoisting in postion complete, as per the design or as directed by the site engineer. Providing and Fixing 11.52millimetre clear laminated tempered glass made of two layers 6millimetre tempered glass of brand Saint Gobain or equivalent, permanently bonded together with 1.52millimetre transparent PVB interlayer under a controlled, highly pressurized and industrial heating process. (4+1.52+4 toughened laminate glass) with Anodised Aluminium backing strip and Pressure tape with weather silicone sealant for the skylight including transportation, lifting and hoisting in postion complete as per the design. or as directed by the site engineer. Providing and Fixing Galvanised Weld Mesh 50x50 of 4.5 millimetre MS wire conforming to IS 4948:2002, welded in ISA30303 frames. Fixed under the ventilation gap below the Sky light as per the design or as directed by the site engineer. Design and Supervision Fees Design of the Special Structural Steel Structure conforming to IS 800 and / 801 code and providing fabrication drawings, boq and supervision. ( TERRACE FLOOR )
145CORE CUTTING Carried out core cutting work as per instruction given by department and structural consultant ( bar locator test carried out prior to core and location got finalized by structural consultant ) 50 MM ( GROUND FLOOR )
146CORE CUTTING Carried out core cutting work as per instruction given by department and structural consultant ( bar locator test carried out prior to core and location got finalized by structural consultant ) 75 MM ( GROUND FLOOR )
147CORE CUTTING Carried out core cutting work as per instruction given by department and structural consultant ( bar locator test carried out prior to core and location got finalized by structural consultant ) 100 MM ( GROUND FLOOR )
148CORE CUTTING Carried out core cutting work as per instruction given by department and structural consultant ( bar locator test carried out prior to core and location got finalized by structural consultant ) 125 MM ( GROUND FLOOR )
149CORE CUTTING Carried out core cutting work as per instruction given by department and structural consultant ( bar locator test carried out prior to core and location got finalized by structural consultant ) 150 MM ( GROUND FLOOR )
150CORE CUTTING Carried out core cutting work as per instruction given by department and structural consultant ( bar locator test carried out prior to core and location got finalized by structural consultant ) 200 MM ( GROUND FLOOR ) Please Enable Macros to View BoQ information
151CORE CUTTING Carried out core cutting work as per instruction given by department and structural consultant ( bar locator test carried out prior to core and location got finalized by structural consultant ) 200 MM ( GROUND FLOOR ) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57883175
AUTHORITY Government Departments
TENDER VALUE 126.37 Crore
LAST DATE 26-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Execution Of Basic Works Proposed Under Parishistha A Of Conservation And Development Plan For The Punyashlok Ahilyadevi Holkar Memorial Site At Choundi Village Tal.Jamkhed Dist.Ahilyanagar (Construction Of River Bank Ghat, Internal Roads, Compound Wall, Enternace Gates, Exibition Block, Green Room, Helipad, Toilets Block & Electricals Work Etc.) And Providing Electrical Installation For Punyashlok Ahilyadevi Holkar Memorial At Chondi, Tal. Jamkhed, Dist. Ahilyanagar[ Part-A To H]
Basic Detail
Tender No E Tender Notice No.09 for 2026-27 B2
Bidding Type Tender
Location
City Ahmednagar
State Maharashtra
Key Dates
Publish Date 06 Oct 2026
Submission Date 26 Oct 2026
Open Date 27 Oct 2026
Finance
Tender Value 126.37 Crore
Tender Fee 3540
EMD 63.19 Lakhs
Exemption Not Available
Document List
aa1a6966-08fb-4f81-8ad4-9ab3874341f2.html
BOQ_2295494.xls
Drawing1.pdf
Drawing10.pdf
Drawing2.pdf
Drawing3.pdf
Drawing4.pdf
Drawing5.pdf
Drawing6.pdf
Drawing7.pdf
Drawing8.pdf
Drawing9.pdf
NIT.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Oct 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

aa1a6966-08fb-4f81-8ad4-9ab3874341f2.html

xls

BOQ_2295494.xls

pdf

Drawing1.pdf

pdf

Drawing10.pdf

pdf

Drawing2.pdf

pdf

Drawing3.pdf

pdf

Drawing4.pdf

pdf

Drawing5.pdf

pdf

Drawing6.pdf

pdf

Drawing7.pdf

pdf

Drawing8.pdf

pdf

Drawing9.pdf

pdf

NIT.pdf