Tender For Comprehensive Maint, Repair, Replacement Of Internal Wiring, Electrical Fittings & Fixtures, Dbs & Mcbs, Fans And Allied Works In C, D, E & F Area At Naval Base Kochi Under Ge (Nw) Kochi
Tender Overview
Project Description
Tender for Comprehensive Maint, Repair, Replacement Of Internal Wiring, Electrical Fittings & Fixtures, Dbs & Mcbs, Fans And Allied Works In C, D, E & F Area At Naval Base Kochi Under Ge (Nw) Kochi
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-Oct-2026 | Corrigendum | BOQ | 03-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down Copper/ aluminium point wiring (light, fan, socket, bell, power point) complete fitting such as switches, ceiling roses, pendants, regulators, sockets, light fitting any type, building security light removing materials to store for keeping in safe custdoy for taking credit to match with existing suface all as specified and directed. |
| 2 | Material and labour for point wiring for one light with 1.5 sqmm PVC insulated (FRLSH) sheathed copper conductor multistranded 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FRLSH) insulated sheathed copper cable multistrand conductor 1100 volts grade for continuity conductor including connected to common earth dolly drawn through and including rigid PVC Conduit 20 mm dia medium grade ISI marked Concealed of suitable size with all accessories and sunken box of 1.6 mm thick and 60 mm Depth pressed steel box factory made for mounting of switch, socket and fan regulator with modular frames covers including chase cutting and making good to the disturbed surface and matching to the existing finishes specifications complete all as specified and as directed. |
| 3 | All as per item No.2 here in before but for one 5 pin 5 Amp socket outlet point on independent board complete all as specified and directed. |
| 4 | All as per item No.2 here in before but for one 5 pin 5 Amp socket outlet point on same board complete all as specified and directed. |
| 5 | All as per item No. 2 here in before but for one bell point controlled by one 5 Amp bell push on independent board complete all as specified and directed. |
| 6 | All as per item No. 2 here in before but for One light point controlled by two 2- way switches, with cables 1.5 sqmm size complete all as specified and directed. |
| 7 | All as per item No.2 here in before but using with 2.5 Sqmm copper conductor multistranded (FRLSH) PVC insulated, sheathed cable and including 2.5 Sqmm copper conductor cable multistranded (FRLSH) PVC insulated and sheathed cable as earth continity wire and connecting to common earth dolly for one 6 pin 15 Amp socket outlet point on independent board complete all as specified and directed. |
| 8 | Supply and fix Modular Bell push 6A, 1module, complete all as specified.Make: Legrand Cat Part No. 5734 13 or equivalent to Schneider/ L&T |
| 9 | Supply and fix Modular fan Regulator, electronic rotary, stepped type 100 Watt, 240 Volt 50 Hz hum free 2 module complete all as specified.Make: Legrand Cat Part No. 5734 63 or equivalent to Schneider/ L&T |
| 10 | Supply and fix Modular Switch 6 Amps 240 Volts one way switch complete all as specified. Make: Legrand Cat Part No. 5734 00 or equivalent to Schneider/ L&T |
| 11 | Supply and fix Modular Socket 6 Amps AC 240 Volts 3/5 pin combined 2 module type complete all as specified.Make: Legrand Cat Part No. 5734 24 or equivalent to Schneider/ L&T |
| 12 | Supply and fix Modular Switch 16 amps AC 240 volts one way complete all as specified.Make : Legrand Cat Part No. 5734 10 or equivalent to Schneider/ L&T |
| 13 | Supply and fix Modular Socket 6A/16 Amps- 3/5 pin combined AC 240 Volts 2 module complete all as specified. Make: Legrand Cat Part No. 5734 71 or equivalent to Schneider/ L&T |
| 14 | Supply and fix switch piano 5 Amp flush type single pole one way including removing old switch complete all as specified and as directed. |
| 15 | Supply and fix switch piano 15 Amp flush type single pole one way including removing old switch complete all as specified and as directed. |
| 16 | Supply and fix in replacement, socket outlet 5 Amps, 5 pin, 2 in 1 complete all as specified and directed. |
| 17 | Supply and fix socket outlet multipurpose 6 and 16 Amps, 5 pin, 2 in 1 including removing old socket complete all as specified and directed. |
| 18 | Supply and fix fan regulator electronic step type 100 W, 250 Volts including removing old socket complete all as specified and as directed. |
| 19 | Supply and fixceiling rose surface bakelite 65 x 50 mm, 3 terminals including removing old ceiling rose complete all as specified and as directed. |
| 20 | Supply and fix lamp holder, PVC/ poly carbonate type with back plate suitable for batten fittings including removing old lamp holder complete all as specified and directed. |
| 21 | Supply and fix electric bell, AC 230 Volt single pole including removing old call bell complete all as specified and as directed. Make : Legrand Cat Part No. 5734 43 or equivalent to Schneider/ L&T |
| 22 | Supply and fix Modular Switch 6 Amps 240 Volts two way switch complete all as specified. Make: Legrand Cat Part No. 5734 00 or equivalent to Schneider/ L&T |
| 23 | S&F in replacement sunken box with Modular white cover plate 2 module with removing old type sunken boxes /wooden board and match with existing surfaces, complete all as specified.Make : Anchor Cat Part No. 212372 module or equivalent to Schneider/ L&T |
| 24 | Supply and fix in replacement sunken box with Modular white cover plate 3 module with removing old type sunken boxes /wooden board and match with existing surfaces , complete all as specified.Make: Anchor Cat Part No. 21306 3 module or equivalent to Schneider/ L&T |
| 25 | Material and Labour in replacement concealed sub main wiring with 2 runs of 4 Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLSH, ISI marked cable drawn through ISI Marked, medium grade, non metallic, PVC conduits and all accessories, with 1 run of 4 Sq mm PVC insulated unsheathed multistranded single core copper conductor FRLSH, and making good disturbed surfaces, applying distemper / Emulsions matching to the existing colour / quality of walls/floors/ceiling etc including taking down old unserviceable light fitting all as specified.Note:- Three run of cable and one run of PVC conduits shall be measured as one unit. |
| 26 | All as per item No. 25 here-in-before but 2 runs of 6 sq mm single core FRLSH copper conductor and 1 run of 6 sqmm conductor for earthing . Note:- Three run of cable and one run of PVC conduits shall be measured as one unit. |
| 27 | All as per item No. 25 here-in-before but 4 runs of 10 sq mm single core FRLSH copper conductor and 1 run of 10 sqmm conductor for earthing . Note:- Five run of cable and one run of PVC conduits shall be measured as one unit. |
| 28 | All as per item No.25 here-in-before but 4 runs of 16 sq mm single core FRLSH copper conductor and 1 run of 16 sqmm conductor for earthing . Note:- Five run of cable and one run of PVC conduits shall be measured as one unit. |
| 29 | Supply and fix in replacement SPN enclosure with two pin and earth plug and socket complete with one SP MCB, 20 Amps having breaking capacity 10 kA, including taking down old unserviceable eath plug including taking down old unserviceable rusted DB complete all as specified.Make L& T Cat Part No.DBMPS220SD or equivalent to Schneider/ L&T |
| 30 | Supply and fix in replacement TP enclosure with two pin and earth plug and socket complete with one TP MCB, 20 Amps having breaking capacity 10 kA, including taking down old unserviceable eath plug including taking down old unserviceable rusted DB complete all as specified.Make L& T Cat Part No.DBMPS320SD or equivalent to Schneider/ L&T |
| 31 | Supply and fix in replacement SPN Steel sheet made out of CRCA 1.2 mm thick, powder coated double door distribution board 4 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing MCBs and the second for protection of MCBs fitted with colour bus bar of capacity 200 Amps, neutral link, earth bar and din rail. suitable for use on 240V, 50Hz supply, partly immersed in wall and making good distrubbed surfaces with matching colour, including taking down old unserviceable light fitting complete all as specified.Make: Legrand Cat Part No. 5076 00 or equivallent to Schneider/ L &T |
| 32 | All as per item No.31 here-in-before but for SPN DB 8 way including taking down old unserviceable rusted DB complete all as specified and directed.Make :Legrand Cat Part No. 5076 01 or equivallent to Schneider/ L &T |
| 33 | All as per item No.31 here-in-before but for for SPN DB 12 way way including taking down old unserviceable rusted DB complete all as specified and directed.Make: Legrand Cat Part No. 5076 02 or equivallent to Schneider/ L &T |
| 34 | Supply and fix in replacement Factory made three phase and neutral Sheet Steel made out of CRCA 1.2 mm thick, powder coated double door TPN distribution board 4 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing MCBs and the second for protection of MCBs fitted with colour bus bar of capacity 200 Amps, neutral link, earth bar and din rail suitable for use on 415V, 50Hz supply, TPN DB, IP-43 protection, partly immersed in wall, and without MCB's including making good distrubbed surfaces with matching colour, including taking down old unserviceable rusted DB complete all as specified and directed by Engineer-in-Charge. Make Legrand Cat Part No. 5076 70 or equivallent to Schneider/ L &T |
| 35 | All as per item No.34 here-in-before but DB 6 way way including taking down old unserviceable rusted DB complete all as specified and directed. Make :Legrand Cat Part No. 5076 71 or equivallent to Schneider/ L &T |
| 36 | Supply and fix in replacement Factory made three phase and neutral Sheet Steel made out of CRCA 1.2 mm thick, powder coated double door vertical distribution board 4 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing MCBs and the second for protection of MCBs fitted with colour bus bar of capacity 200 Amps, neutral link, earth bar and din rail suitable for use on 415V, 50Hz supply, VTPN DB, IP-43 protection, partly immersed in wall, with MCCB 125 Amps 4 pole and without MCB's including making good distrubbed surfaces with matching colour, complete including taking down old unserviceable rusted DB all as specified and directed by Engineer-in-Charge. . Make: Legrand Cat Part No. 5077 20 or equivallent to Schneider/ L&T |
| 37 | All as per item No.36 here-in-before but VTPN DB 6 way including taking down old unserviceable rusted DB complete all as specified and directed.Make: Legrand Cat Part No. 5077 21 or equivallent to Schneider/ L &T |
| 38 | Supply and fix in replacement MCB SP 6-32 Amps current carrying capacity 'C' curve miniature circuit breaker (MCB) 240V, 10KA in the MCB DB complete with connection testing and commissioning including taking down old unserviceable light fitting complete all as specified and as directed. Make: Legrand Cat Part No. 4085 87 to 4085 95 or equivallent to Schneider/ L &T |
| 39 | Supply and fix in replacement MCB SPN 20-32 Amps current carrying capacity 'C' curve miniature circuit breaker (MCB) 240V, 10KA in the MCB DB complete with connection testing and commissioning including taking down old unserviceable light fitting complete all as specified and as directed. Make: Legrand Cat Part No. 4086 15 to 4086 17 or equivallent to Schneider/ L &T |
| 40 | Supply and fix in replacement MCB SPN 40-63 Amps current carrying capacity 'C' curve miniature circuit breaker (MCB) 240V, 10KA in the MCB DB complete with connection testing and commissioning including taking down old unserviceable light fitting complete all as specified and as directed. Make :Legrand Cat Part No. 4086 18 to 4086 20 or equivallent to Schneider/ L &T |
| 41 | Supply and fix iin replacement MCB TP 25-63 Amps current carrying capacity 'C' curve miniature circuit breaker (MCB) 415V, 10KA in the MCB DB complete with connection testing and commissioning including taking down old unserviceable light fitting complete all as specified and as directed. Make: Legrand Cat Part No. 4086 57 to 4086 61 or equivallent to Schneider/ L &T |
| 42 | Supply and fix in replacement MCB TPN 16-32 amps current carrying capacity 'C' curve miniature circuit breaker (MCB) 415V, 10KA in the MCB DB complete with connection testing and commissioning including taking down old unserviceable light fitting complete all as specified and as directed. Make: Legrand Cat Part No. 4086 77 to 4086 80 or equivallent to Schneider/ L &T |
| 43 | Supply and fix in replacement MCB TPN 40-100 Amps current carrying capacity 'C' curve miniature circuit breaker (MCB) 415V, 10KA in the MCB DB complete with connection testing and commissioning complete all as specified and as directed. Make: Legrand Cat Part No. 4086 81 to 4086 83 or equivallent to Schneider/ L &T |
| 44 | Supply and fix in replacement SS enclosure suitable for housing of MCCB 100-200 amp complete all as specified and directed.Make : L&T Cat part No. CM91003OOOO or Schneider or Legrand |
| 45 | Supply and fix in replacement MCCB FP 63 Amps thermal magnatic 25 kA including taking down old unserviceable light fitting complete all as specified and directed. Make: L&T Cat part No. CM91712OOJOOG or equivallent to Schneider of Legrand |
| 46 | Supply and fix in replacement MCCB FP 100 Amps thermal magnatic 25 kA including taking down old unserviceable light fitting complete all as specified and directed.Make: L&T Cat part No. CM90642OOLO or equivallent to Schneider/ Legrand |
| 47 | Supply and fixF in replacement MCCB FP 160 Amps adjustable type thermal magnatic 36 kA including taking down old unserviceable light fitting complete all as specified and directed. Make: L&T Cat part No. CM90642OONO or equivallent to Schneider/ Legrand |
| 48 | Supply and fix in replacement MCCB FP 200 Amps adjustable type thermal magnatic 36 kA including taking down old unserviceable light fitting complete all as specified and directed. Make: L&T Cat part No. CM90642OOPO or equivallent to Schneider/ Legrand |
| 49 | Supply and fix in replacement MCCB FP 400 Amps adjustable type, thermal magnatic 36 kA including taking down old unserviceable light fitting complete all as specified and directed. Make: L&T Cat part No. CM94106OOS1OG or equivallent to Schneider/ Legrand |
| 50 | Supply and fix in replacement ceiling light driver 5/ 7/ 10 Watt with all accessories and connection to the electric circuit including taking down old unserviceable light fitting complete all as specified. Make : Philips or equivallent to Crompton / Havells |
| 51 | Supply and fix in replacement ceiling light driver 12/ 15/ 20 Watt with all accessories and connection to the electric circuit including taking down old unserviceable light fitting complete all as specified. Make : Philips or equivallent to Crompton / Havells |
| 52 | Supply and fix in replacement LED glass T8 tube 20 watt, 220 volt ,50 Hz, LED tube rod, double side connection,inbuilt driver including taking down old unserviceable light fitting complete all as specified. Make:Havells Cat ref CRYSTALT81213SSTL20WLED865SGLASS Or Equivallent to Philips or Crompton |
| 53 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including taking down old unserviceable light fitting complete all as specified and directed. Make : Philips Cat Part No. BN100C LED20S-6500 PSU L120 GR S4 or equivalent to Crompton/ Havells |
| 54 | Supply and fix in replacement bed side Lamp 3 watt , min 120 lum/watt, 50 hz,230 volts,3000k with all accessories and connection to the electric circuit including taking down old unserviceable light fitting complete all as specified.Make : Philips Cat Part no - 48042 or equivalent to Crompton/ Havells |
| 55 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size including taking down old unserviceable light fitting complete all as specified. Make: Philips Cat part no - RC780X LED12S-6500 PSU W5L56 OD WH or equivalent to Crompton/ Havells |
| 56 | Supply and fixing LED Wall light fitting fancy type with high out put diffuser 2 feet, 12 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size including taking down old unserviceable light fitting complete all as specified. Make: Philips Cat part no - RC780X LED12S-6500 PSU W5L56 OD WH or equivalent to Crompton/ Havells |
| 57 | Supply and fix in replacement 6 Watt dimmable cob light recess mounted Ceiling light , min 120 lumne/watt, round, 50 Hz, 230 Volts with all accessories and connection to the electric circuit including taking down old unserviceable light fitting complete all as specified. Make: Philips Cat part no -RS262B LED6S/865 PSU MB WH or equivalent to Crompton/ Havells |
| 58 | Supply and fix in replacement 15 Watt dimmable cob light recess mounted Ceiling light , min 120 lumne/watt, round, 50 Hz, 230 Volts with all accessories and connection to the electric circuit including taking down old unserviceable light fitting complete all as specified. Make: Philips Cat part no - RS262B LED15S/865 PSU MB WH or equivalent to Crompton/ Havells |
| 59 | Supply and fix in replacement 15 Watt Spot light , min 120 lumne/watt, round, 50 Hz, 230 Volts with all accessories and connection to the electric circuit including taking down old unserviceable light fitting complete all as specified. Make: Philips Cat part no - SM296C LED15S-6500 PSU WH or equivalent to Crompton/ Havells |
| 60 | Supply and fix in replacement LED ‘T’ type retrofit fitting 14 Watt, 6500-7500K, Min 120 Lumen/Watt maximum output 1400 lumen to be used polycarbonate material including taking down old unserviceable light fitting complete all as specified and as directed. Make : Philips Cat Part No. TLL-14W-6500K-B22 or equivallent to make specified in PS. |
| 61 | Supply and fix in replacement 6 Watt recessed round down lighter with high luminous LED for indoor application,230 volts ,50 Hzs ,min 120 lm /watt with all accessories and connection to the electric circuit including taking down old unserviceable light fitting complete all as specified. Make: Philips Cat part no -DN495 LED6S-6500 PSU WH or equivalent to Crompton/ Havells |
| 62 | Supply and fix in replacement 12 Watt recessed round down lighter with high luminous LED for indoor application,230 volts ,50 Hzs ,min 120 lm /watt with all accessories and connection to the electric circuit including taking down old unserviceable light fitting complete all as specified. Make: Philips Cat part no -DN496 LED12S-6500 PSU WH or equivalent to Crompton/ Havells |
| 63 | Supply and fix in replacement 15 Watt recessed round down lighter with high luminous LED for indoor appliCation,230 volts ,50 Hzs ,min 120 lm /watt with all accessories and connection to the electric circuit including taking down old unserviceable light fitting complete all as specified. Make: Philips Cat part no -DN496 LED15S-6500 PSU WH or equivalent to Crompton/ Havells |
| 64 | Supply and fix in replacement 18 Watt recess mounted Ceiling light in Dome series , min 120 lumne/watt, round, 50 Hz, 230 Volts with all accessories and connection to the electric circuit including taking down old unserviceable light fitting complete all as specified. Make: Philips Cat part no - SM296C LED20S-6500 PSU WH or equivalent to Crompton/ Havells |
| 65 | Supply and fixing LED luminaire 300 mm x 300 mm, 20 watt, min 120 lum/watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size including taking down old unserviceable light fitting complete. all as specified and directed. Make: Philips Cat Part no - RC360B LED25S-4000 L30W30 PSU OD or equivalent to Crompton/ Havells |
| 66 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, min 120 lum/watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size including taking down old unserviceable light fitting complete all as specified and directed. Make: Philips Cat Part no - RC370B LED36S-6500 G6 L60W60 PSU OD V3 or equivalent to Crompton/ Havells |
| 67 | Supply and fixing LED luminaire 1200 mm x 300 mm, 36 watt, min 120 lum/watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size including taking down old unserviceable light fitting complete all as specified and directed. Make: Philips Cat Part no - RC380B LED36S-6500 G5 L12W3 PSU OD or equivalent to Crompton/ Havells |
| 68 | Supply and fix in replacement Suspened LED lighting solution with 52 mm width and 75 mm height 25 watt ,min 120 lum/watt, 230V,50 Hz, including connected accessories including provision of flexible copper wire from ceiling rose to light fitting terminal including taking down old unserviceable light fitting complete all as specified and directed. Make : Philips Cat part no -SP170P LED25S-6500 PSU W5L113 OD WHor equivalent to Crompton/ Havells |
| 69 | Supply and fix in replacement LED building security light 60 watts , min 120 Lm/w, 50 Hz,220 volts having IP-65 protection, pressure die cast aluminium housing, high luminious efficiancy and high power including taking down old unserviceable light fitting complete all as specified.Make: Philips Cat Part no - BRP331 LED54 CW R5N PC PSU S1 V1 or equivalent to Crompton/ Havells |
| 70 | Supply and fix in replacement LED Flood Light 100 Watt, min 120 lum/watt, 50 Hz,220 volts having IP-66 protection, pressure die cast aluminium housing, high luminious efficiancy and high power including taking down old unserviceable light fitting complete all as specified.Make : Philips Cat Part no - BVP282 LED120 CW FG SY5WB 100W V1 or equivalent to Crompton/ Havells |
| 71 | Supply and fix in replacement LED Flood Light 210 Watt, min 120 lum/watt, 50 Hz,220 volts having IP-66 protection, pressure die cast aluminium housing, high luminious efficiancy and high power including taking down old unserviceable light fitting complete all as specified.Make : Philips Cat Part no - BVP283 LED240 CW FG SY5WB 200W SPD V1 or equivalent to Crompton/ Havells |
| 72 | Supply and fix in replacement High Bay light 200 Watt, min 120 lum/watt, 50 Hz,220 volts having IP-66 protection, pressure die cast aluminium housing, high luminious efficiancy and high power including taking down old unserviceable light fitting complete all as specified.Make : Philips Cat Part no -BY616P LED200S 5700 NB PSU GRor equivalent to Crompton/ Havells |
| 73 | Supply and fix in replacement of integral LED Aviation obstruction light 10W comprising of aluminium housing with polycarbonate enclosure including taking down old unserviceable light fitting complete all as specified.Make : Bajaj Cat Part no - RC780X LED12S-6500 PSU W5L56 OD WH or equivalent to |
| 74 | Supply and fix Flame proof/ Weather proof LED tube light fitting (4 feet) suitable for 1 X 15 watt with glass & connector sutable for LED tube light with all accessories prewired, product in Al. die cast alloy LM6 construction of Gas Gr. IIA, IIB certified by CIMFR dhanbad &CCOE(PESO) Nagpur along with ISI marking including testing complete all as specified and directed including taking down of existing fitting. Make : Crompton part No EXTN2LT8-16/20 or Shyam switch gear/Sudhir |
| 75 | Supply and fix FLP rotary switch single pole 16 Amps and fixing arrangement including taking down of existing FLP swtich complete all as specified and directed by Eng-In-Charage.Make- Cat No: Sudhir switch Gear RI/OA/1010-2A or equivalent of Shyam |
| 76 | Supply and lay in repair PVC sheathed , multi stranded copper conductor , 3 core , flexible cable , 1100 V grade, 2.5 sqmm, Ac connecting complete all as directed. |
| 77 | Supply and laying LT control cable ,copper conductor armoured 2XWY/2XFY,PVC inner sheeted armoured (galvanised wire for cable) of size 4 core 4 sqmm, 1100 volt grade as per IS -7068 (part -I) 1988 complete all as specified and directed. Make :- Havells /RR Kabel/Finolex. |
| 78 | Supply and lay in replacement flexible metal conduit 40 mm dia complete all as specified and directed. |
| 79 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminiumconductor,served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 6mm suspension wire, one twin core cable flat or circular complete all as specified. |
| 80 | Supply and laying in replacement XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 6 sq.mm 2 core including taking down old unserviceable cable complete all as specified. |
| 81 | Supply and laying in replacement XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 35 sq.mm 3.5core including taking down old unserviceable cable complete all as specified. |
| 82 | Supply and laying in replacement XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 50 sq.mm 3.5 core including taking down old unserviceable cable complete all as specified. |
| 83 | Supply and laying in replacement XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 120 sq.mm 3.5 core including taking down old unserviceable cable complete all as specified. |
| 84 | Supply and fix in replacement of rolling shutter motor single phase operated, rated voltage - 220/230V,50/60Hz ,370-565W of output torque -412Nm, output speed -4.8 R/m-6.0/R/m including taking down old and deposite to AGE E/M (NW) Store yard complete all as specified. |
| 85 | Supply and laying in replacement of rolling shutter door control ETC button station, 3 way crane ,roller door control ETC button station .2N/O1N/C contact fitted, Double insulated up arrow, stop down arrow legends suitable for 600 Kg,single phase rolling shutter motor including taking down old one and deposite to AGE E/M (NW) Store yard complete all as specified and directed. |
| 86 | Taking down unserviceable ceiling fan of 1200 / 1400 mm sweep, cutting out the existing burnt out fan motor winding, cleaning the motor slots, rewinding the motor with insulated copper winding wire of existing gauge, baking / heating up the motor to achieve the proper insulation resistance and refixing testing complete including marking MES No complete all as specified. |
| 87 | All as per item Ser No. 86 above but here in before for exhaust fan of 450/300/250 mm sweep complete all as specified. |
| 88 | All as per item Ser No. 86 above but here in before for wall mounted fan of 400 /450 mm sweep complete all as specified. |
| 89 | All as per item Ser No. 86 above but here in before for pedestal fan 600 /400 mm sweep complete all as specified. |
| 90 | Supply and fix in replacement capacitor for ceiling fans,230 volts, 2.5 MFD including necessary soldering including taking down old unserviceable capacitor complete all as specified and as directed. Make Havells Cat Part No. QHPCWC5002X5 or Keltron. |
| 91 | Supply and fix in replacement in replacement capacitor for any type of exhaust fan/ pedestial fan/ air circulator fan 230 volts AC including necessary soldering of capacity 4 MFD including taking down old unserviceable capacitor complete all as specified and directed. Make Havells Cat Part No. QHPCWC5004X0 or Keltron. |
| 92 | Supply and fix in replacement ball bearing 6201 suitable for ceiling fans including taking down the old one all as specified and directed. |
| 93 | Supply and fix in replacemen ball bearing 6202 suitable for ceiling fans including taking down the old one all as specified and directed. |
| 94 | Supply and fix in replacement PVC body exhaust fan motor suitable for 250/300 mm of size of any make as per site requirement including taking down old unserviceable burntout motor complete all as specified and as directed. |
| 95 | Supply and fix in replacement down rod, suitably threaded and holed, made out of 15 mm dia GI tube heavy grade, duly painted, 2' long, suitable for ceiling fan any type, any make, any size including taking down old unserviceable rusted DB complete all as specified and directed. |
| 96 | All as per item Ser No. 95 above but here in before for 3' long |
| 97 | Supply and fix in replacement a set of Nickel plated mild steel clamps, Nuts, Bolts, Washers and split pin rubber reel insulator, fan canopy with tightening screw/check nut, made out of PVC, suitable for ceiling fans any type, any make, any size including taking down old unserviceable all above complete all as specified and directed. |
| 98 | Material and Labour for replacement of hanging hook for ceiling fan, made out of mild steel round bar not less than 15 mm thick, fixed to ceiling with suitable MS base plate, nuts, bolts, and washers. The assembly shall be securely anchored to the structural member to safely bear the load of the fan. The work includes fabrication, drilling, fixing in position, and painting of all exposed metal surfaces with one coat of red oxide primer and two coats of synthetic enamel paint, including taking down old unserviceable rusted hook complete all as specified and directed. |
| 99 | Supply and fixing replacement copper conductor multistranded cable flexible 03 core PVC insulated of size 40/0.076 at site/MES store yard complete including taking down the old one all as specified and directed. |
| 100 | Material and Labour for checking of ceiling fans stability (like fan hooks,nuts, bolts, hanging rod ,canopy ,washer etc and exhaust fan stability ,loose connection in distribution boards,MCBs in NSRY Area at Naval base complete all as specified and directed. Note: - 1. The contractor should prepaired a register and enter office name with signature of offce incharge and submited to engineer in charge office. |
| 101 | Supply and fix in replacement rigid non metalic PVC conduit 25 mm dia, medium grade, ISI marked including junction boxes, tee, bends, elbows, reducers bell mouth tube ends,fixing accessories such as couplers, lock Nuts, saddle pipe hook etc complete including taking out old one complete all as specified and directed. |
| 102 | Material and Labour for checking of faulty / jumped energy meter (three phase /single phase) with fixing of new energy meter in series and after one week submmitted meter reading report of both energy meter in engr in charge office including taking out old one complete all as specified and directed. |
| 103 | Material and Labour in replacement Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized iron wire 4 mm dia as earth up to 7.5 m distance and connected by means of bolts, nuts, checknuts and washers of galvanised iron or steel all shown in electric plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including provision of necessary excavation and earth work in any type of soil, PCC pit , RCC cover 50 mm thick, reinforced with 8 mm dia TMT bars both ways @ 10 CM c/c , 20 mm bore medium grade watering pipe, water funnel, 15 mm bore GI medium grade protection pipe, common salt, charcoal dust, returning, filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc including testing on completion completeall as specified.Note :- (i) The unit rate includes for protection pipe and earth lead upto 7.50 Mtr. (ii) Earth lead beyond 7.50 Mtr length shall be measured and paid separately. |
| 104 | Material and Labour in replacement aluminium strip 25 x 3.15 mm with porcelain insulators,saddles and fixing screws etc for roof conductor and down conductor above ground all as specified and directed. |
| 105 | Material and Labour in replacement of eathing chamber made out FRP of breaking capacity of 5 ton with necessory pcc work required with smooth surface duly coloured after repair work and cover of the size of the earth pit comple all as specified and directed. |
| 106 | Material and Labour for Checking of earthing resistence and E-N voltage with caliberated earth tester meter and multimeter including repair of earth pits by filling salt and charcoal as reqd for earthing of lightening arrestor of building /workshop/hanger /OTM etc at Naval Base Kochi complete with maintaining the earth testing record in a register with signature of user. |
| 107 | NOTE FOR ALL ITEMS :-1.Contractor should display the display board of the contract details i.e CA No,Name of work, Name of the firm,Name of the contractor with contact No,Name of the supervisor with contact No,Name of the Elecrician/plumber with contact No,Name of the JE E/M with contact No,Name of the Engr-in-Charge with contact No,Dt of commencement of CA and Dt of completion of CA complete all as directed by the Engr-in-Charge.2.Contractor shall be deployed supervisor at MES complaint cell 24X7 on all working days including sundays and Holidays to issue and print the online complaints in the MES online portal and register the same in CA online complaint register and register emergency offline complaints in CA offline complaint register then complete all as directed by the Engr-in-Charge.3.All day to day complaints for item No 8-30, 38-84, 91-99 &105 should be completed on the same day of the complaint received.Penality @ Rs 300 per complaint wil be charged for non compliance of compalints.4. Rate for all above notes are deemed inclusive in the item rate quoted. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender