Tender For Provn Of Hard Standing With Interlocking Tiles For Veh Parking Near Mt Garage Of Bldg No P-391 And P-392 Of 91 Inf Bde C And Provn Of 12 X 1.5 Ton Ac For Various Wards At Bldg No P-290 Of Mh At Pms Under Ge (Army) Trivandrum
Tender Overview
Project Description
Tender for Provn Of Hard Standing With Interlocking Tiles For Veh Parking Near Mt Garage Of Bldg No P-391 And P-392 Of 91 Inf Bde C And Provn Of 12 X 1.5 Ton Ac For Various Wards At Bldg No P-290 Of Mh At Pms Under Ge (Army) Trivandrum
BOQ
| Sl. No. | Item Description |
| 1 | Excavating over areas n exc 1.5 m in depth and getting out in hard/ dense soil complete all as specified and directed |
| 2 | M&L for hard core of gauge n. exc 63 mm, deposited, spread and levelled in layers n exc 10cm thick, broken stone or boulder, watered and rammed to a true surface complete all as specified and directed |
| 3 | M&L for 100 mm thick PCC 1:3:6 type C2 (using 40 mm graded crushed stone aggregate) as in sub base including all necessary form work completed all as specified and directed. |
| 4 | M&L for Sand filling/cushioning under floors or in foundations including well ramming, watering and consolidation. |
| 5 | M&L for machine pressed precast concrete interlocking coloured paver block any shape and size conforming to IS 15658-2006 of 80mm thickness, M-40 Grade with grey cement and pigment complete all as specified and directed. |
| 6 | M&L for providing cement concrete 1:2:4, Type B1, using 20 mm graded stone aggregate as in parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs or mud stops rounded or chamfered edges including necessary formwork complete all as specified and directed. |
| 7 | M&L for 100 mm thick PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in sub base including all necessary form work finishing exposed edges fair or rounding of chamfering completed all as specified and directed. |
| 8 | M&L for coloured & polished chequered cement concrete tiles 20cmx20cmx25mm/ 30cmx30cmx 25mm thick set, jointed and pointed in neat cement slurry as in floors including 20mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 9 | Removing excavated material to a distance exceeding 50m and not exceeding 250m and depositing where directed at a level not exceeding 1.5m above from the starting point complete all as specified and directed. |
| 10 | Excavating in trenches in hard/ dense soil, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out complete all as specified and directed. |
| 11 | M&L for PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in surfaces channels, drains including all necessary form work completed all as specified and directed |
| 12 | M&L for pre-cast cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in CM 1:6 complete all as specified and directed. |
| 13 | M&L for rendering 15 mm thick cement plaster on fair faces of brick work/ concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and directed. |
| 14 | M&L extra forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, metered/stopped ends etc complete all as specified and directed. |
| 15 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm using soil obtained from excavation complete all as specified and directed. |
| 16 | Removing excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 17 | S&F Mild Steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks' drilling holes; including all necessary drilling, bolting or riveting, and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed |
| 18 | M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide Zinc Chrome primer complete all as specified. |
| 19 | M & L for Point wiring complete with all specified with 1100 Volts grade 4.00 sqmm single core PVC insulated FRLSH unsheathed cable 1100 volts grade multistranded copper conductor single core conforming to IS-694 1990 with ISI marked (for phase, neutral and earth) in and including PVC casing and capping with ISI mark of minimum 20/25 mm size and all casing and capping accessories and including factory made branded make embossed galvanised steel pressed terminal boxes along with suitable size modular cover plates with frames for fixing modular switches and sockets , fan regulators etc of suitable sizes modules and the earth wire connected to common earth dolly complete all as specified and directed for one 3 pin modular switch socket outlet 16 Amps on independent board. |
| 20 | S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed |
| 21 | S&F Voltage Stabilizer for automatic operation, single phase naturally air cooled, copper wounded as per IS 8448-1989 with digital display, wall mounted, indoor type and designed for input variation between 170Volt to 270Volt with output voltage stabilized at 230Volt with accuracy of + 2.5Volt and of capacity 5KVA complete all as specified and directed |
| 22 | Supply and install hi wall split units indoor/outdoor 1.5 TR complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity as shown, electric driven single phase, 230V, 50 Hz, AC including necessary fixing arrangement complete as relevant IS (Indoor unit at suitable place and height inside the room and outdoor unit at suitable place out side the room on plinth height/on wall or roof as suitable and as directed) including wall mounting (with fixing suitable size of bolts for outdoor unit, insulated piping etc complete all as specified and directed . Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender