Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #57882812

Tender For Provision Of Sprinkling System For Adm Block Area, Provn Of Street Light With Pole From Watch Tower No. 01 To Watch Tower No. 03, Provn Of Flood Light In Badminton Court And Provn Of Deficient Ceilling Fan, Exhaust Fan And Geyser At Icgs V

Issued by Statutory Bodies & Commissions/Committees · Jamnagar, Gujarat
Tender Value
22 Lakhs
Estimated cost
Bid Submission
27 Oct 2026
19 days left
EMD
44000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jamnagar → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provision Of Sprinkling System For Adm Block Area, Provn Of Street Light With Pole From Watch Tower No. 01 To Watch Tower No. 03, Provn Of Flood Light In Badminton Court And Provn Of Deficient Ceilling Fan, Exhaust Fan And Geyser At Icgs Vadinar

BOQ

Name of Work:- PROVISION OF SPRINKLING SYSTEM FOR ADM BLOCK AREA, PROVN OF STREET LIGHT WITH POLE FROM WATCH TOWER NO. 01 TO WATCH TOWER NO. 03, PROVN OF FLOOD LIGHT IN BADMINTON COURT AND PROVN OF DEFICIENT CEILLING FAN, EXHAUST FAN AND GEYSER AT ICGS VADINAR
Sl. No. Item Description
1Schedule 'A'
2Supply, laying and testing for CPVC pipes of size 50 mm dia (outer dia) SDR-11 including plain CPVC SDR including all fittings such as bends elbows, tees, short pieces, connectors, check nuts, diminishing pieces, caps and plugs, unions, etc fixed complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post and including making good, complete all as specified and as directed.
3Supply, laying and testing for CPVC pipes of size 32 mm dia (outer dia) SDR-11 including plain CPVC SDR including all fittings such as bends elbows, tees, short pieces, connectors, check nuts, diminishing pieces, caps and plugs, unions, etc fixed complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post and including making good complete all as specified and as directed.
4Supply, laying and testing for CPVC pipes of size 25 mm dia (outer dia) SDR-11 including plain CPVC SDR including all fittings such as bends elbows, tees, short pieces, connectors, check nuts, diminishing pieces, caps and plugs, unions, etc fixed complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post and including making good complete all as specified and as directed.
5Supply, laying and testing for CPVC pipes of size 20 mm dia (outer dia) SDR-11 including plain CPVC SDR including all fittings such as bends elbows, tees, short pieces, connectors, check nuts, diminishing pieces, caps and plugs, unions, etc fixed complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post and including making good complete all as specified and as directed.
6Supply, laying and testing for CPVC pipes of size 62.5 mm dia (inner dia) Schedule 80 including plain CPVC including Schedule 80 fittings such as bends elbows, tees, short pieces, connectors, check nuts, diminishing pieces, caps and plugs, unions, etc fixed complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post and including making good all as specified and as directed.
7S & F for Ball Valve Long Handle of size 50 mm dia and connected at both ends for CPVC pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc. and including any addition / alteration required for fixing, including valve chamber of size 300 X 300 X 300 mm including necessary earth work in any type of soil, necessary excavation earth work all plastered surfaces of valve chambers and making good complete all as specified and as directed.
8S & F for Ball Valve Long Handle of size 32 mm dia and connected at both ends for CPVC pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc. and including any addition / alteration required for fixing, including valve chamber of size 300 X 300 X 300 mm including necessary earth work in any type of soil, necessary excavation earth work all plastered surfaces of valve chambers and making good complete all as specified and as directed.
9M&L for cutting existing road/hard standing not exc 45 x 45 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil complete all as specified and directed.
10S & F for GI steel tubing light grade 80 mm dia for laying in ground and road crossing along the pole in coping etc for cable protection including necessary fittings, clamps for supports, etc and all as specified and directed.
11Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth for laying of pipes and getting out Soft/ Loose soil complete all as specified and directed.
12Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth for laying of cable /pipes, foundation, fixing poles, stays, etc and getting out Hard/ dense soil complete all as specified and directed.
13Excavation in trenches not exc 1.5 m wide and exc 1.5m in depth for laying of cable /pipes, foundation, fixing poles, stays, etc and getting out Hard/ dense soil complete all as specified and directed.
14Returning , filling in including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick with excavated an type soil complete all as specified and directed by Engineer-in-Charge.
15Removing excavated material (surplus soil) to a distance not exceeding 50 mtrs and depositing where directed at a level not exc 1.5 m above the starting point all as specified and directed by Engineer-in-Charge.
16M & L for dry sand cushioning for under ground cable in trenches 8 cm before laying and 15 cm after laying of cable and sand should be 18 cm after consolidation complete all as specified and directed by Engineer-in-Charge.
17Supply and laying for un-reinforced precast concrete cable cover LV, Type 1 flat, size 250 x 150 x 40mm complete all as specified and as directed.
18S&F Galvanised steel tubing with all fittings light grade 40 mm bore, fixed on walls/ pole/ in floor, etc, fixed with & including duly painted MS clamps made out of MS FI 40 x 6 mm & necessary nuts, bolts, washers,complete all as specified and as directed.
19Material & labour for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation of street light poles complete all as specified and as directed.
20Material & labour for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundation of street light poles complete all as specified and as directed.
21M&L for PCC 1:3:6 type C-1 using 20mm graded stone aggregate in copping complete all as specified and as directed.
22Supply and erect steel tubular swaged poles complete with MS base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP- 31 (8.5 metres long) conforming to IS-2713 including applying two coats of uminium paint over a coat of red oxide zinc chrome primer over the exposed surface and applying two coats of black bitumenous paint over the embeded portion of pole, erecting in truly vertical position including excavation in any strata and earth work complete all as specified and as directed.
23Supply, Installation , testing and commissioning of LED type street light fitting suitable for 70 watt capacity LED lamp ,IP 66 pressure die cast housing with epoxy powder coated aluminium housing drak graphite gray colour finish Enclosure complete with control driver ,fixed on street light pole connecting with 1.5 sqmm 3 core copper cable from street light connector to junction box with suitable size lugs/thimble complete all as specified and as directed.
24Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed by Engineer-in-Charge.
25Supply and fixing thermoplastic cable junction box for street lights of size 205 x 255 x 112mm including bus bar/terminal for cable connection with IP-66 protection,complete all as specified and directed by Engineer-in-Charge. Make : Hensel Cat No.DK 2525 G or its equivalent specified in Legrand/sintex
26Supply & Fixing for Wiring with 2.5 Sqmm, 3 Core, PVC insulated and FRLS PVC Round sheathed, copper conductor (flexible) industrial cable, 1100 Volts, conforming to IS-694, connecting light fittings/ terminals with copper lugs, complete all as specified and directed by Engineer-in-Charge.
27M&L for cutting existing road/hard standing not exc 45 x 45 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil complete all as specified and directed.
28M & L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion and including excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep, with a 10 mm thick CI cover, hinged to CI frame on ground level, GI watering pipe, funnel, etc and testing complete all as specified and as directed.
29Supply & fix for LED flood light fitting 150 Watt with LED lamps and driver and made of pressure die-cast aluminium housing IP66 road way luminaries (wider beam angle not less than 120 degree, optics with convex lens/pinet lens) with UV stablized polycarbonate cover or heat resistant toughen glass cover and high power LEDs as light source with LED fittings system Lumen not less than 100 lumen per watt and electronic driver with efficiency 85% with inbuilt protection against lighting, over voltage, short circuit and surge/spike protection upto 10 KV ensuring longer life (THD<10%, PF shall be > 0.95, colour temperature 5700±300K), life expectancy of LEDs minimum 50,000 burning hrs, warranty of complete luminaries fitting shall not less than three years. The fitting shall be tested in NABL accredited LAB and LM 79 & LM 80 test certificate shall be submitted by the original manufacturer, including connection complete all as specified.Make:Havells Cat Part:Havells LHEPARU7PN7J150 or equivalent specified in Philips/Crompton
30M&L point wiring with 2.5 sqmm (nominal Area), PVC insulated multistranded , single core , unsheathed , copper conductor cables with colour code as per IS specifications drawn through PVC Conduit of 25mm dia with all fittings and accessories of PVC Conduit (like Tee, bend,junctions clips,screws etc) complete fixed to walls/ceiling etc. with including 2.5 sqmm (nominal area) PVC insulated , unsheathed, stranded , single core, copper cable green in colour as in earth continuity wire connecting to common earth point complete all as specified.
31S&F Modular switch 1 way, 16 Amps, 1 module complete all as specified and as directed by Engineer-in-Charge.
32Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and frequency 50 Hz, including a down road of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan with smart remot control complete all as specified and as directed.
33Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated above rated complete with all accessories such as safety valve, thermostate, NRV, with Anchor fastners of suitable size and including Flexible hot/cold connection Pipe -02 Nos, complete all as specified and as directed.
34Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louverscomplete all as specified and as directed.
35Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57882812
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 22 Lakhs
LAST DATE 27-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provision Of Sprinkling System For Adm Block Area, Provn Of Street Light With Pole From Watch Tower No. 01 To Watch Tower No. 03, Provn Of Flood Light In Badminton Court And Provn Of Deficient Ceilling Fan, Exhaust Fan And Geyser At Icgs Vadinar
Basic Detail
Tender No 8233A/E8
Bidding Type Tender
Location
City Jamnagar
State Gujarat
Key Dates
Publish Date 06 Oct 2026
Submission Date 27 Oct 2026
Open Date 30 Oct 2026
Finance
Tender Value 22 Lakhs
Tender Fee 500
EMD 44000
Exemption Available
Document List
79618103-24d3-4073-a5b0-65c53719e85b.html
8233AT.pdf
BOQ_888410.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Oct 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

79618103-24d3-4073-a5b0-65c53719e85b.html

pdf

8233AT.pdf

xls

BOQ_888410.xls

pdf

Tendernotice_1.pdf

Disclaimer