Power Boards / Undertakings / PSU Closing in 12 days TDR #57881642

Tender for procurement of pressure & temperature gauges for ggsstp, ropar.

Issued by Boards / Undertakings / PSU · Rupnagar, Punjab
Tender Value
Ref. Documents
Estimated cost
Bid Submission
28 Oct 2026
12 days left
EMD
10800
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Rupnagar → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

procurement of pressure & temperature gauges for ggsstp, ropar. , gauges , direct mounting bottom entry temperature gauges range 0-120co, direct mounting bottom entry, connection size :1/2 npt(m), dial size 150mm, bulb dia. 8mm, bulb length 200mm, other spec. as per annexure-i. , direct mounting bottom entry temperature gauges range 0-200 deg, direct mounted, bottom entry, connection size: 1/2 npt (m), dial size 150mm, bulb length 300mm, stem dia 10 mm. other spec. as per annexure-i. , direct mounting bottom entry temperature gauges range 0-120co, direct mounting bottom entry, connection size :1/2 npt(m),dial size 100mm, bulb dia. 8mm, bulb length 150mm, other spec. as per annexure-i. , direct mounting bottom entry temperature gauges range 0-120co,direct mounting bottom entry, connection size :1/2 npt (m),dial size 100mm,bulb dia. 10mm, bulb length 150mm, other spec. as per annexure-i. , direct mounted back entry temperature gauges without capillary range 0-100co, vertical mounting back entry with hunting absorber spring and male adaptor of 1/2 npt(m) to fit into process, l-shape, dial 150mm, bulb dia 10mm, bulb length 300mm. other specifications as per annexure -iii , direct mounted back entry temperature gauges without capillary range 0-120co, direct mounting back entry connection size: 1/2 npt (m), dial size 100mm, bulb length 200mm adjustable, bulb dia 6mm. other spec. as per ann-iii. , direct mounted back entry temperature gauges without capillary range 0-150co, direct mounting back entry, connection size: 1/2 npt (m), dial size 100mm, bulb length 425 mm adjustable, bulb dia 8 mm. other spec. as per annexure- iii. (for fo tank-iv) , direct mounted back entry temperature gauges without capillary range 0-150co, direct mounting back entry, connection size: 1/2 npt (m), dial size 100mm, bulb length 825mm adjustable, bulb dia 8 mm. other spec. as per annexure-iii (for fo tank-iii) , direct mounted back entry temperature gauges without capillary range 0-150co, direct mounting back entry connection size: 1/2 npt (m), dial size 100mm, bulb length 140mm adjustable, bulb dia 6mm. other spec. as per ann-iii. , panel mounted back entry temperature gauges: range 0-200co, gauge back entry for panel mounting with clamp fitting. connection size :1/2 npt(m), dial size 150mm, bulb length 200mm, capillary length 5 meters, bulbdia/stem dia 8mm, other specification as per ann-ii. , panel mounted back entry temperature gauges: range 0-200co, back entry for panel mounting with clamp fitting. conn. size :1/2 npt(m), dial size100mm, bulb length 200mm, capillary length 8 meters, stem dia 8mm, other specs as per annex-ii. , panel mounted back entry temperature gauges: temperature gauge back entry for panel mounting with clamp fitting. connection size :1/2 npt(m), range 0-120co, dial size 100mm, bulb length 200mm, capillary length 5 meters, bulbdia/stem dia 8mm, other specification as per annex-ii. , panel mounted back entry temperature gauges: range 0-120co, back entry for panel mounting with clamp fitting. connection size :1/2 npt(m), dial size 150mm, bulb length 200mm, capillary length 8 meters, bulbdia/stem dia 8mm, other specification as annex-ii , panel mounted back entry temperature gauges: range 0-200co, back entry for panel mounting with clamp fitting connection size: 1/2 npt (m), dial size 150mm, bulb length 200mm, capillary length 12 meters. bulb dia/ stem dia 8mm. other spec as per annex-ii , panel mounted back entry temperature gauges: range 0-120 deg, panel mounted, back entry, dial size=100mm, connection size :1/2 npt(m), bulb dia. and bulb length:- as per annexure vii, capillary length=7 mtr, other spec. as per annexure-ii , panel mounted back entry temperature gauges: range 0-200co, back entry for panel mounting with clamp fitting without thermo well. connection size :1/2 npt(m), dial size 100 mm, capillary length 5 meters, bulb length &bulbdia/stem dia. as per annexure iv, other specification as per annex-ii. , pressure gauges: dial size 150 mm, connection ½bsp(m), direct bottom entry. 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii range 0 to 60 kg/cm2 , pressure gauges: dial size 150 mm, connection ½bsp(m), direct bottom entry. 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii range 0 to 40 kg/cm2 , dial size 150 mm, connection ½npt(m), direct bottom entry, 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii. range 0 to 10 kg/cm2 , dial size 150 mm, connection ½npt(m), direct bottom entry, 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii range 0 to 16 kg/cm2 , dial size 100 mm, connection ½bsp(m), direct bottom entry, 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii. range 0 to 6 kg/cm2 , dial size 100 mm, connection ½bsp(m), direct bottom entry, 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii. range 0 to 10 kg/cm2 , dial size 100 mm, connection ½bsp(m), direct bottom entry, 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii. range 0 to 16 kg/cm2 , dial size 150 mm, panel mounting with back entry, with connection ½npt (m), 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii. range 0 to 16 kg/cm2 , dial size 150 mm, panel mounting with back entry, with connection ½npt (m), 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii. range 0 to 25 kg/cm2 , dial size 150 mm, panel mounting with back entry, with connection ½npt (m), 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii. range 0 to 40 kg/cm2 , sealed diaphragm, dial size 150 mm, direct bottom entry, connection ½npt(m) , 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with eachgauge. other spec. as per annexure-x range 0 to 25 kg/cm2 , dial size 50mm, connection ¼bsp(m), back entry, 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-xi. range 0 to 250 kg /cm2 , dial size 40mm, connection 1/8npt(m), direct bottom entry, 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-xvi. range 0-2 kg/cm2 , dial size 100mm, panel mounting, connection 1/4”bsp(m), 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per ann- xvii. range 0 to 250 kg /cm2 , dial size 63 mm, connection ¼ npt(m), bottom entry , 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annex- xvii. range 0 to 140 kg /cm2

BOQ

Name of Work:- Procurement of Pressure & Temperature Gauges for GGSSTP, Ropar.
Sl. No. Item Description
1Gauges
2Direct Mounting Bottom Entry Temperature Gauges Range 0-120Co, Direct Mounting Bottom Entry, Connection Size :1/2\\" NPT(M), Dial Size 150mm, Bulb Dia. 8mm, Bulb Length 200mm, Other spec. as per Annexure-I.
3Direct Mounting Bottom Entry Temperature Gauges Range 0-200 deg, Direct mounted, Bottom Entry, Connection Size: 1/2\\" NPT (M), Dial Size 150mm, Bulb Length 300mm, Stem Dia 10 mm. Other spec. as per Annexure-I.
4Direct Mounting Bottom Entry Temperature Gauges Range 0-120Co, Direct Mounting Bottom Entry, Connection Size :1/2\\" NPT(M),Dial Size 100mm, Bulb Dia. 8mm, Bulb Length 150mm, Other spec. as per Annexure-I.
5Direct Mounting Bottom Entry Temperature Gauges Range 0-120Co,Direct Mounting Bottom Entry, Connection Size :1/2\\" NPT (M),Dial Size 100mm,Bulb Dia. 10mm, Bulb Length 150mm, Other spec. as per Annexure-I.
6Direct Mounted Back Entry Temperature Gauges without Capillary Range 0-100Co, Vertical Mounting Back Entry with hunting absorber spring and Male Adaptor of 1/2\\" NPT(M) to fit into process, L-Shape, Dial 150mm, Bulb dia 10mm, Bulb length 300mm. Other Specifications as per Annexure -III
7Direct Mounted Back Entry Temperature Gauges without Capillary Range 0-120Co, Direct Mounting back Entry Connection Size: 1/2\\" NPT (M), Dial Size 100mm, Bulb Length 200mm adjustable, Bulb Dia 6mm. Other spec. as per Ann-III.
8Direct Mounted Back Entry Temperature Gauges without Capillary Range 0-150Co, Direct Mounting back Entry, Connection Size: 1/2\\" NPT (M), Dial Size 100mm, Bulb Length 425 mm adjustable, Bulb Dia 8 mm. Other spec. as per Annexure- III. (For FO tank-IV)
9Direct Mounted Back Entry Temperature Gauges without Capillary Range 0-150Co, Direct Mounting back Entry, Connection Size: 1/2\\" NPT (M), Dial Size 100mm, Bulb Length 825mm adjustable, Bulb Dia 8 mm. Other spec. as per Annexure-III (For FO tank-III)
10Direct Mounted Back Entry Temperature Gauges without Capillary Range 0-150Co, Direct Mounting back Entry Connection Size: 1/2\\" NPT (M), Dial Size 100mm, Bulb Length 140mm adjustable, Bulb Dia 6mm. Other spec. as per Ann-III.
11Panel Mounted Back Entry Temperature Gauges: Range 0-200Co, Gauge Back Entry for Panel Mounting with clamp fitting. Connection Size :1/2\\" NPT(M), Dial Size 150mm, Bulb Length 200mm, Capillary Length 5 meters, BulbDia/Stem Dia 8mm, Other specification as per Ann-II.
12Panel Mounted Back Entry Temperature Gauges: Range 0-200Co, Back Entry for Panel Mounting with clamp fitting. Conn. Size :1/2\\" NPT(M), Dial Size100mm, Bulb Length 200mm, Capillary Length 8 meters, Stem Dia 8mm, Other specs as per Annex-II.
13Panel Mounted Back Entry Temperature Gauges: Temperature Gauge Back Entry for Panel Mounting with clamp fitting. Connection Size :1/2\\" NPT(M), Range 0-120Co, Dial Size 100mm, Bulb Length 200mm, Capillary Length 5 meters, BulbDia/Stem Dia 8mm, Other specification as per Annex-II.
14Panel Mounted Back Entry Temperature Gauges: Range 0-120Co, Back Entry for Panel Mounting with clamp fitting. Connection Size :1/2\\" NPT(M), Dial Size 150mm, Bulb Length 200mm, Capillary Length 8 meters, BulbDia/Stem Dia 8mm, Other specification as Annex-II
15Panel Mounted Back Entry Temperature Gauges: Range 0-200Co, Back entry for Panel Mounting with clamp fitting Connection Size: 1/2\\" NPT (M), Dial Size 150mm, Bulb Length 200mm, Capillary Length 12 meters. Bulb Dia/ Stem Dia 8mm. Other spec as per Annex-II
16Panel Mounted Back Entry Temperature Gauges: Range 0-120 Deg, Panel mounted, Back entry, Dial Size=100mm, Connection Size :1/2\\" NPT(M), Bulb Dia. and Bulb Length:- as per Annexure VII, Capillary Length=7 Mtr, Other spec. as per Annexure-II
17Panel Mounted Back Entry Temperature Gauges: Range 0-200Co, Back Entry for Panel Mounting with clamp fitting without thermo well. Connection Size :1/2\\" NPT(M), Dial Size 100 mm, Capillary Length 5 meters, Bulb Length &BulbDia/Stem Dia. as per Annexure IV, Other specification as per Annex-II.
18Pressure Gauges: Dial Size 150 mm, Connection ½\\"BSP(M), Direct Bottom Entry. 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Annexure-VIII Range 0 to 60 Kg/Cm2
19Pressure Gauges: Dial Size 150 mm, Connection ½\\"BSP(M), Direct Bottom Entry. 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Annexure-VIII Range 0 to 40 Kg/Cm2
20Dial Size 150 mm, Connection ½\\"NPT(M), Direct Bottom Entry, 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Annexure-VIII. Range 0 to 10 Kg/Cm2
21Dial Size 150 mm, Connection ½\\"NPT(M), Direct Bottom Entry, 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Annexure-VIII Range 0 to 16 Kg/Cm2
22Dial Size 100 mm, Connection ½\\"BSP(M), Direct Bottom Entry, 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Annexure-VIII. Range 0 to 6 Kg/Cm2
23Dial Size 100 mm, Connection ½\\"BSP(M), Direct Bottom Entry, 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Annexure-VIII. Range 0 to 10 Kg/Cm2
24Dial Size 100 mm, Connection ½\\"BSP(M), Direct Bottom Entry, 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Annexure-VIII. Range 0 to 16 Kg/Cm2
25Dial Size 150 mm, Panel Mounting with back Entry, with Connection ½\\"NPT (M), 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Annexure-VIII. Range 0 to 16 Kg/Cm2
26Dial Size 150 mm, Panel Mounting with back Entry, with Connection ½\\"NPT (M), 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Annexure-VIII. Range 0 to 25 Kg/Cm2
27Dial Size 150 mm, Panel Mounting with back Entry, with Connection ½\\"NPT (M), 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Annexure-VIII. Range 0 to 40 Kg/Cm2
28Sealed diaphragm, Dial size 150 mm, Direct Bottom Entry, Connection ½\\"NPT(M) , 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with eachgauge. Other spec. as per Annexure-X Range 0 to 25 Kg/Cm2
29Dial Size 50mm, Connection ¼\\"\\"BSP(M), Back Entry, 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Annexure-XI. Range 0 to 250 Kg /Cm2
30Dial Size 40mm, Connection 1/8\\"NPT(M), Direct Bottom Entry, 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Annexure-XVI. Range 0-2 Kg/cm2
31Dial size 100mm, panel mounting, Connection 1/4”BSP(M), 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Ann- XVII. Range 0 to 250 Kg /Cm2
32Dial Size 63 mm, Connection ¼ \\"NPT(M), Bottom entry , 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Annex- XVII. Range 0 to 140 Kg /Cm2 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57881642
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 28-10-2026
Authority
Authority Name Punjab State Power Corporation Limited
Work Description procurement of pressure & temperature gauges for ggsstp, ropar. , gauges , direct mounting bottom entry temperature gauges range 0-120co, direct mounting bottom entry, connection size :1/2 npt(m), dial size 150mm, bulb dia. 8mm, bulb length 200mm, other spec. as per annexure-i. , direct mounting bottom entry temperature gauges range 0-200 deg, direct mounted, bottom entry, connection size: 1/2 npt (m), dial size 150mm, bulb length 300mm, stem dia 10 mm. other spec. as per annexure-i. , direct mounting bottom entry temperature gauges range 0-120co, direct mounting bottom entry, connection size :1/2 npt(m),dial size 100mm, bulb dia. 8mm, bulb length 150mm, other spec. as per annexure-i. , direct mounting bottom entry temperature gauges range 0-120co,direct mounting bottom entry, connection size :1/2 npt (m),dial size 100mm,bulb dia. 10mm, bulb length 150mm, other spec. as per annexure-i. , direct mounted back entry temperature gauges without capillary range 0-100co, vertical mounting back entry with hunting absorber spring and male adaptor of 1/2 npt(m) to fit into process, l-shape, dial 150mm, bulb dia 10mm, bulb length 300mm. other specifications as per annexure -iii , direct mounted back entry temperature gauges without capillary range 0-120co, direct mounting back entry connection size: 1/2 npt (m), dial size 100mm, bulb length 200mm adjustable, bulb dia 6mm. other spec. as per ann-iii. , direct mounted back entry temperature gauges without capillary range 0-150co, direct mounting back entry, connection size: 1/2 npt (m), dial size 100mm, bulb length 425 mm adjustable, bulb dia 8 mm. other spec. as per annexure- iii. (for fo tank-iv) , direct mounted back entry temperature gauges without capillary range 0-150co, direct mounting back entry, connection size: 1/2 npt (m), dial size 100mm, bulb length 825mm adjustable, bulb dia 8 mm. other spec. as per annexure-iii (for fo tank-iii) , direct mounted back entry temperature gauges without capillary range 0-150co, direct mounting back entry connection size: 1/2 npt (m), dial size 100mm, bulb length 140mm adjustable, bulb dia 6mm. other spec. as per ann-iii. , panel mounted back entry temperature gauges: range 0-200co, gauge back entry for panel mounting with clamp fitting. connection size :1/2 npt(m), dial size 150mm, bulb length 200mm, capillary length 5 meters, bulbdia/stem dia 8mm, other specification as per ann-ii. , panel mounted back entry temperature gauges: range 0-200co, back entry for panel mounting with clamp fitting. conn. size :1/2 npt(m), dial size100mm, bulb length 200mm, capillary length 8 meters, stem dia 8mm, other specs as per annex-ii. , panel mounted back entry temperature gauges: temperature gauge back entry for panel mounting with clamp fitting. connection size :1/2 npt(m), range 0-120co, dial size 100mm, bulb length 200mm, capillary length 5 meters, bulbdia/stem dia 8mm, other specification as per annex-ii. , panel mounted back entry temperature gauges: range 0-120co, back entry for panel mounting with clamp fitting. connection size :1/2 npt(m), dial size 150mm, bulb length 200mm, capillary length 8 meters, bulbdia/stem dia 8mm, other specification as annex-ii , panel mounted back entry temperature gauges: range 0-200co, back entry for panel mounting with clamp fitting connection size: 1/2 npt (m), dial size 150mm, bulb length 200mm, capillary length 12 meters. bulb dia/ stem dia 8mm. other spec as per annex-ii , panel mounted back entry temperature gauges: range 0-120 deg, panel mounted, back entry, dial size=100mm, connection size :1/2 npt(m), bulb dia. and bulb length:- as per annexure vii, capillary length=7 mtr, other spec. as per annexure-ii , panel mounted back entry temperature gauges: range 0-200co, back entry for panel mounting with clamp fitting without thermo well. connection size :1/2 npt(m), dial size 100 mm, capillary length 5 meters, bulb length &bulbdia/stem dia. as per annexure iv, other specification as per annex-ii. , pressure gauges: dial size 150 mm, connection ½bsp(m), direct bottom entry. 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii range 0 to 60 kg/cm2 , pressure gauges: dial size 150 mm, connection ½bsp(m), direct bottom entry. 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii range 0 to 40 kg/cm2 , dial size 150 mm, connection ½npt(m), direct bottom entry, 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii. range 0 to 10 kg/cm2 , dial size 150 mm, connection ½npt(m), direct bottom entry, 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii range 0 to 16 kg/cm2 , dial size 100 mm, connection ½bsp(m), direct bottom entry, 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii. range 0 to 6 kg/cm2 , dial size 100 mm, connection ½bsp(m), direct bottom entry, 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii. range 0 to 10 kg/cm2 , dial size 100 mm, connection ½bsp(m), direct bottom entry, 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii. range 0 to 16 kg/cm2 , dial size 150 mm, panel mounting with back entry, with connection ½npt (m), 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii. range 0 to 16 kg/cm2 , dial size 150 mm, panel mounting with back entry, with connection ½npt (m), 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii. range 0 to 25 kg/cm2 , dial size 150 mm, panel mounting with back entry, with connection ½npt (m), 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii. range 0 to 40 kg/cm2 , sealed diaphragm, dial size 150 mm, direct bottom entry, connection ½npt(m) , 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with eachgauge. other spec. as per annexure-x range 0 to 25 kg/cm2 , dial size 50mm, connection ¼bsp(m), back entry, 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-xi. range 0 to 250 kg /cm2 , dial size 40mm, connection 1/8npt(m), direct bottom entry, 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-xvi. range 0-2 kg/cm2 , dial size 100mm, panel mounting, connection 1/4”bsp(m), 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per ann- xvii. range 0 to 250 kg /cm2 , dial size 63 mm, connection ¼ npt(m), bottom entry , 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annex- xvii. range 0 to 140 kg /cm2
Basic Detail
Tender No 7872 /P-2/EMP- 13416 Dated 01.10.26
Bidding Type Tender
Location
City Rupnagar
State Punjab
Key Dates
Publish Date 06 Oct 2026
Submission Date 28 Oct 2026
Open Date 30 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 10800
Exemption Available
Document List
56ca24db-e196-4ef3-8690-3b1b215bfb03.html
BOQ_360431.xls
mainenquiryfi.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Oct 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

56ca24db-e196-4ef3-8690-3b1b215bfb03.html

xls

BOQ_360431.xls

pdf

mainenquiryfi.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender