Tender for procurement of pressure & temperature gauges for ggsstp, ropar.
Tender Overview
Project Description
procurement of pressure & temperature gauges for ggsstp, ropar. , gauges , direct mounting bottom entry temperature gauges range 0-120co, direct mounting bottom entry, connection size :1/2 npt(m), dial size 150mm, bulb dia. 8mm, bulb length 200mm, other spec. as per annexure-i. , direct mounting bottom entry temperature gauges range 0-200 deg, direct mounted, bottom entry, connection size: 1/2 npt (m), dial size 150mm, bulb length 300mm, stem dia 10 mm. other spec. as per annexure-i. , direct mounting bottom entry temperature gauges range 0-120co, direct mounting bottom entry, connection size :1/2 npt(m),dial size 100mm, bulb dia. 8mm, bulb length 150mm, other spec. as per annexure-i. , direct mounting bottom entry temperature gauges range 0-120co,direct mounting bottom entry, connection size :1/2 npt (m),dial size 100mm,bulb dia. 10mm, bulb length 150mm, other spec. as per annexure-i. , direct mounted back entry temperature gauges without capillary range 0-100co, vertical mounting back entry with hunting absorber spring and male adaptor of 1/2 npt(m) to fit into process, l-shape, dial 150mm, bulb dia 10mm, bulb length 300mm. other specifications as per annexure -iii , direct mounted back entry temperature gauges without capillary range 0-120co, direct mounting back entry connection size: 1/2 npt (m), dial size 100mm, bulb length 200mm adjustable, bulb dia 6mm. other spec. as per ann-iii. , direct mounted back entry temperature gauges without capillary range 0-150co, direct mounting back entry, connection size: 1/2 npt (m), dial size 100mm, bulb length 425 mm adjustable, bulb dia 8 mm. other spec. as per annexure- iii. (for fo tank-iv) , direct mounted back entry temperature gauges without capillary range 0-150co, direct mounting back entry, connection size: 1/2 npt (m), dial size 100mm, bulb length 825mm adjustable, bulb dia 8 mm. other spec. as per annexure-iii (for fo tank-iii) , direct mounted back entry temperature gauges without capillary range 0-150co, direct mounting back entry connection size: 1/2 npt (m), dial size 100mm, bulb length 140mm adjustable, bulb dia 6mm. other spec. as per ann-iii. , panel mounted back entry temperature gauges: range 0-200co, gauge back entry for panel mounting with clamp fitting. connection size :1/2 npt(m), dial size 150mm, bulb length 200mm, capillary length 5 meters, bulbdia/stem dia 8mm, other specification as per ann-ii. , panel mounted back entry temperature gauges: range 0-200co, back entry for panel mounting with clamp fitting. conn. size :1/2 npt(m), dial size100mm, bulb length 200mm, capillary length 8 meters, stem dia 8mm, other specs as per annex-ii. , panel mounted back entry temperature gauges: temperature gauge back entry for panel mounting with clamp fitting. connection size :1/2 npt(m), range 0-120co, dial size 100mm, bulb length 200mm, capillary length 5 meters, bulbdia/stem dia 8mm, other specification as per annex-ii. , panel mounted back entry temperature gauges: range 0-120co, back entry for panel mounting with clamp fitting. connection size :1/2 npt(m), dial size 150mm, bulb length 200mm, capillary length 8 meters, bulbdia/stem dia 8mm, other specification as annex-ii , panel mounted back entry temperature gauges: range 0-200co, back entry for panel mounting with clamp fitting connection size: 1/2 npt (m), dial size 150mm, bulb length 200mm, capillary length 12 meters. bulb dia/ stem dia 8mm. other spec as per annex-ii , panel mounted back entry temperature gauges: range 0-120 deg, panel mounted, back entry, dial size=100mm, connection size :1/2 npt(m), bulb dia. and bulb length:- as per annexure vii, capillary length=7 mtr, other spec. as per annexure-ii , panel mounted back entry temperature gauges: range 0-200co, back entry for panel mounting with clamp fitting without thermo well. connection size :1/2 npt(m), dial size 100 mm, capillary length 5 meters, bulb length &bulbdia/stem dia. as per annexure iv, other specification as per annex-ii. , pressure gauges: dial size 150 mm, connection ½bsp(m), direct bottom entry. 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii range 0 to 60 kg/cm2 , pressure gauges: dial size 150 mm, connection ½bsp(m), direct bottom entry. 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii range 0 to 40 kg/cm2 , dial size 150 mm, connection ½npt(m), direct bottom entry, 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii. range 0 to 10 kg/cm2 , dial size 150 mm, connection ½npt(m), direct bottom entry, 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii range 0 to 16 kg/cm2 , dial size 100 mm, connection ½bsp(m), direct bottom entry, 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii. range 0 to 6 kg/cm2 , dial size 100 mm, connection ½bsp(m), direct bottom entry, 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii. range 0 to 10 kg/cm2 , dial size 100 mm, connection ½bsp(m), direct bottom entry, 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii. range 0 to 16 kg/cm2 , dial size 150 mm, panel mounting with back entry, with connection ½npt (m), 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii. range 0 to 16 kg/cm2 , dial size 150 mm, panel mounting with back entry, with connection ½npt (m), 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii. range 0 to 25 kg/cm2 , dial size 150 mm, panel mounting with back entry, with connection ½npt (m), 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-viii. range 0 to 40 kg/cm2 , sealed diaphragm, dial size 150 mm, direct bottom entry, connection ½npt(m) , 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with eachgauge. other spec. as per annexure-x range 0 to 25 kg/cm2 , dial size 50mm, connection ¼bsp(m), back entry, 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-xi. range 0 to 250 kg /cm2 , dial size 40mm, connection 1/8npt(m), direct bottom entry, 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annexure-xvi. range 0-2 kg/cm2 , dial size 100mm, panel mounting, connection 1/4”bsp(m), 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per ann- xvii. range 0 to 250 kg /cm2 , dial size 63 mm, connection ¼ npt(m), bottom entry , 1 no. isolating needle valve (fxm) (material–ss316) suitable for specified range and process connection to be provided with each gauge. other spec. as per annex- xvii. range 0 to 140 kg /cm2
BOQ
| Sl. No. | Item Description |
| 1 | Gauges |
| 2 | Direct Mounting Bottom Entry Temperature Gauges Range 0-120Co, Direct Mounting Bottom Entry, Connection Size :1/2\\" NPT(M), Dial Size 150mm, Bulb Dia. 8mm, Bulb Length 200mm, Other spec. as per Annexure-I. |
| 3 | Direct Mounting Bottom Entry Temperature Gauges Range 0-200 deg, Direct mounted, Bottom Entry, Connection Size: 1/2\\" NPT (M), Dial Size 150mm, Bulb Length 300mm, Stem Dia 10 mm. Other spec. as per Annexure-I. |
| 4 | Direct Mounting Bottom Entry Temperature Gauges Range 0-120Co, Direct Mounting Bottom Entry, Connection Size :1/2\\" NPT(M),Dial Size 100mm, Bulb Dia. 8mm, Bulb Length 150mm, Other spec. as per Annexure-I. |
| 5 | Direct Mounting Bottom Entry Temperature Gauges Range 0-120Co,Direct Mounting Bottom Entry, Connection Size :1/2\\" NPT (M),Dial Size 100mm,Bulb Dia. 10mm, Bulb Length 150mm, Other spec. as per Annexure-I. |
| 6 | Direct Mounted Back Entry Temperature Gauges without Capillary Range 0-100Co, Vertical Mounting Back Entry with hunting absorber spring and Male Adaptor of 1/2\\" NPT(M) to fit into process, L-Shape, Dial 150mm, Bulb dia 10mm, Bulb length 300mm. Other Specifications as per Annexure -III |
| 7 | Direct Mounted Back Entry Temperature Gauges without Capillary Range 0-120Co, Direct Mounting back Entry Connection Size: 1/2\\" NPT (M), Dial Size 100mm, Bulb Length 200mm adjustable, Bulb Dia 6mm. Other spec. as per Ann-III. |
| 8 | Direct Mounted Back Entry Temperature Gauges without Capillary Range 0-150Co, Direct Mounting back Entry, Connection Size: 1/2\\" NPT (M), Dial Size 100mm, Bulb Length 425 mm adjustable, Bulb Dia 8 mm. Other spec. as per Annexure- III. (For FO tank-IV) |
| 9 | Direct Mounted Back Entry Temperature Gauges without Capillary Range 0-150Co, Direct Mounting back Entry, Connection Size: 1/2\\" NPT (M), Dial Size 100mm, Bulb Length 825mm adjustable, Bulb Dia 8 mm. Other spec. as per Annexure-III (For FO tank-III) |
| 10 | Direct Mounted Back Entry Temperature Gauges without Capillary Range 0-150Co, Direct Mounting back Entry Connection Size: 1/2\\" NPT (M), Dial Size 100mm, Bulb Length 140mm adjustable, Bulb Dia 6mm. Other spec. as per Ann-III. |
| 11 | Panel Mounted Back Entry Temperature Gauges: Range 0-200Co, Gauge Back Entry for Panel Mounting with clamp fitting. Connection Size :1/2\\" NPT(M), Dial Size 150mm, Bulb Length 200mm, Capillary Length 5 meters, BulbDia/Stem Dia 8mm, Other specification as per Ann-II. |
| 12 | Panel Mounted Back Entry Temperature Gauges: Range 0-200Co, Back Entry for Panel Mounting with clamp fitting. Conn. Size :1/2\\" NPT(M), Dial Size100mm, Bulb Length 200mm, Capillary Length 8 meters, Stem Dia 8mm, Other specs as per Annex-II. |
| 13 | Panel Mounted Back Entry Temperature Gauges: Temperature Gauge Back Entry for Panel Mounting with clamp fitting. Connection Size :1/2\\" NPT(M), Range 0-120Co, Dial Size 100mm, Bulb Length 200mm, Capillary Length 5 meters, BulbDia/Stem Dia 8mm, Other specification as per Annex-II. |
| 14 | Panel Mounted Back Entry Temperature Gauges: Range 0-120Co, Back Entry for Panel Mounting with clamp fitting. Connection Size :1/2\\" NPT(M), Dial Size 150mm, Bulb Length 200mm, Capillary Length 8 meters, BulbDia/Stem Dia 8mm, Other specification as Annex-II |
| 15 | Panel Mounted Back Entry Temperature Gauges: Range 0-200Co, Back entry for Panel Mounting with clamp fitting Connection Size: 1/2\\" NPT (M), Dial Size 150mm, Bulb Length 200mm, Capillary Length 12 meters. Bulb Dia/ Stem Dia 8mm. Other spec as per Annex-II |
| 16 | Panel Mounted Back Entry Temperature Gauges: Range 0-120 Deg, Panel mounted, Back entry, Dial Size=100mm, Connection Size :1/2\\" NPT(M), Bulb Dia. and Bulb Length:- as per Annexure VII, Capillary Length=7 Mtr, Other spec. as per Annexure-II |
| 17 | Panel Mounted Back Entry Temperature Gauges: Range 0-200Co, Back Entry for Panel Mounting with clamp fitting without thermo well. Connection Size :1/2\\" NPT(M), Dial Size 100 mm, Capillary Length 5 meters, Bulb Length &BulbDia/Stem Dia. as per Annexure IV, Other specification as per Annex-II. |
| 18 | Pressure Gauges: Dial Size 150 mm, Connection ½\\"BSP(M), Direct Bottom Entry. 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Annexure-VIII Range 0 to 60 Kg/Cm2 |
| 19 | Pressure Gauges: Dial Size 150 mm, Connection ½\\"BSP(M), Direct Bottom Entry. 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Annexure-VIII Range 0 to 40 Kg/Cm2 |
| 20 | Dial Size 150 mm, Connection ½\\"NPT(M), Direct Bottom Entry, 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Annexure-VIII. Range 0 to 10 Kg/Cm2 |
| 21 | Dial Size 150 mm, Connection ½\\"NPT(M), Direct Bottom Entry, 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Annexure-VIII Range 0 to 16 Kg/Cm2 |
| 22 | Dial Size 100 mm, Connection ½\\"BSP(M), Direct Bottom Entry, 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Annexure-VIII. Range 0 to 6 Kg/Cm2 |
| 23 | Dial Size 100 mm, Connection ½\\"BSP(M), Direct Bottom Entry, 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Annexure-VIII. Range 0 to 10 Kg/Cm2 |
| 24 | Dial Size 100 mm, Connection ½\\"BSP(M), Direct Bottom Entry, 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Annexure-VIII. Range 0 to 16 Kg/Cm2 |
| 25 | Dial Size 150 mm, Panel Mounting with back Entry, with Connection ½\\"NPT (M), 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Annexure-VIII. Range 0 to 16 Kg/Cm2 |
| 26 | Dial Size 150 mm, Panel Mounting with back Entry, with Connection ½\\"NPT (M), 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Annexure-VIII. Range 0 to 25 Kg/Cm2 |
| 27 | Dial Size 150 mm, Panel Mounting with back Entry, with Connection ½\\"NPT (M), 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Annexure-VIII. Range 0 to 40 Kg/Cm2 |
| 28 | Sealed diaphragm, Dial size 150 mm, Direct Bottom Entry, Connection ½\\"NPT(M) , 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with eachgauge. Other spec. as per Annexure-X Range 0 to 25 Kg/Cm2 |
| 29 | Dial Size 50mm, Connection ¼\\"\\"BSP(M), Back Entry, 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Annexure-XI. Range 0 to 250 Kg /Cm2 |
| 30 | Dial Size 40mm, Connection 1/8\\"NPT(M), Direct Bottom Entry, 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Annexure-XVI. Range 0-2 Kg/cm2 |
| 31 | Dial size 100mm, panel mounting, Connection 1/4”BSP(M), 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Ann- XVII. Range 0 to 250 Kg /Cm2 |
| 32 | Dial Size 63 mm, Connection ¼ \\"NPT(M), Bottom entry , 1 no. isolating Needle valve (FxM) (material–SS316) suitable for specified range and process connection to be provided with each gauge. Other spec. as per Annex- XVII. Range 0 to 140 Kg /Cm2 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender