Tender For Designing, Providing, Fixing, Testing And Commissioning Of Online Water Quality Analyzer, Vacuum Operated Automatic Switchover, Dry-Media Scrubber, Automatic Shut Off Valve And All Other Works Contingent Thereto At Various Stations With 90
Tender Overview
Project Description
Tender for Designing, Providing, Fixing, Testing And Commissioning Of Online Water Quality Analyzer, Vacuum Operated Automatic Switchover, Dry-Media Scrubber, Automatic Shut Off Valve And All Other Works Contingent Thereto At Various Stations With 900 Kg Cylinders For Urban Areas Under Phed No.2 Bhiwani With Three Months Trial Run, One Year Defect Liability Period And Comprehensive Maintenance Period Of Five Years -[Dnit No.-178150] Rs. 898.40 Lacs
BOQ
| Sl. No. | Item Description |
| 1 | Designing, providing, fixing, testing and commissioning of CHLORINE GAS DRY SCRUBBER FOR 900 KG CHLORINE GAS CYLINDER as per technical specifications issued by Head Office, PHED, Haryana Memo No.-23070-23142 dated 28-02-2024. |
| 2 | Designing, providing, fixing, testing and commissioning of AUTO-SHUT OFF VALVE as per technical specifications issued by Head Office, PHED, Haryana Memo No. -23070-23142 dated 28-02-2024 |
| 3 | Designing, providing, fixing, testing and commissioning of ONLINE COLORIMETRIC WATER QUALITY ANALYZER FOR RESIDUAL CHLORINE AND TURBIDITY including RTU-Cum-Gateway with Cellular (GSM, GPRS,4G/L TE,5G, NB-IoT), LoRa or other RF technology for remote data transfer as per technical specifications issued by Head Office, PHED, Haryana Memo No. -23070-23142 dated 28-02-2024. |
| 4 | Designing, providing, fixing, testing and commissioning of VACUUM-OPERATED AUTOMATIC SWITCHOVER SYSTEM WITH ALTERNATE CHLORINATOR as per technical specifications issued by Head Office, PHED, Haryana Memo No.- 23070-23142 dated 28-02-2024 |
| 5 | NS Item -`Designing, Supply and erection of PETROL GENSET set of 10 KVA capacity with noise controlled devices acoustic of suitable rating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50cycles 415 plus (-)1% volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with diesel engine complete with suitable size incoming cable from generator to change over/AMF panel, making 2nd incoming cable connection from transformer, outgoing cable connection from changeover/ standard panel, making second incoming cable connection from transformer, outgoing cable connection from changeover / STD panel to incomer of motor starter panel, fenced enclosure with platformfor Petrol Genset complete as per following detailed scope and specifications and directions of Engineer-in-charge. The rating should be at 1500 RPM.a) Petrol Engineb) Alternatorc) Battery 24 V.d) Base Plate.e) suitable sq mm suitable core copper cable upto 40 meters.f) Tools, standard panelg) Metering set 415 VAC-1 set (Amp. meter, Volt Meter, ASS,VSS, Phase Indicator, control fuse, frequency meter, CT`s)h) Metering set 60/5A/110V (Amp. Meter, Volt Meter)i) Overload protection for DC-1 No.j) Battery Charger 24V DCk)Copper bus bar of suitable sizel) KWH meter 96 sqmm sizem) Starting fuse button and key switch (on/off)n) Indicating lamps for low lubricated oil pressure, highcoolant temperature, set running, load on, Dc control andother required accessories complete in all respects to thesatisfaction of Engineer-in-charge` |
| 6 | Comprehensive maintenance of complete system under this DNIT in all respect including replacement of any part and consumables including reagents of original make, SIM data cost, network and cloud storage etc for 1st year |
| 7 | Comprehensive maintenance of complete system under this DNIT in all respect including replacement of any part and consumables including reagents of original make, SIM data cost, network and cloud storage etc for 2nd year |
| 8 | Comprehensive maintenance of complete system under this DNIT in all respect including replacement of any part and consumables including reagents of original make, SIM data cost, network and cloud storage etc for 3rd year |
| 9 | Comprehensive maintenance of complete system under this DNIT in all respect including replacement of any part and consumables including reagents of original make, SIM data cost, network and cloud storage etc for 4th year |
| 10 | Comprehensive maintenance of complete system under this DNIT in all respect including replacement of any part and consumables including reagents of original make, SIM data cost, network and cloud storage etc for 5th year Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender