Tender For Electrification Alongwith Networking, Pa System, Fire Alarm System And Associated Works Of Block-120 At Inrp Site, Tarapur.
Tender Value
3.26 Crore
Estimated cost
Bid Submission
21 Oct 2026
3 days left
EMD
6.52 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Palghar → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Electrification Alongwith Networking, Pa System, Fire Alarm System And Associated Works Of Block-120 At Inrp Site, Tarapur.
BOQ
| Sl. No. | Item Description |
| 1 | Supply of following configuration 415V, 3-phase, 4 wire, double door,with R Y B Phase indication and mcb position indication through glass front, IP-54, Prewired with HFFR/ FRLS copper wires, horizontal type, metallic Double Door, Phase Segregated three pole and neutral MCB Distribution Board fabricated out of 2 mm thick ,powder coated with RAL7035 shade , pre-galvanised G.I. sheet steel, suitable for surface mounting/ installation in existing enclosure complete with appropriate rating of tinned copper bus bar/ Cu wire, neutral bus bar, earth bar, din bar,brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes , neoprene gasket, etc as per drawing, specifications & generally as per relevant IS & as per instructions of Engineer-in-charge. |
| 2 | Supply of 8 way MCB DB having 1 no. main incomer of 32A TPN MCB, Isc=10kA, Type C with 3 nos. of 25A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 24 nos. outgoing of 6A SPN MCB suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 3 | Supply of 6 way MCB DB having 1 no. main incomer of 32A TPN MCB, Isc=10kA, Type C with 3 nos. of 25A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 18 nos. outgoing of 6A SPN MCB suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 4 | Supply of 4 way MCB DB having 1 no. main incomer of 32A TPN MCB, Isc=10kA, Type C with 3 nos. of 25A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 12 nos. outgoing of 16A SPN MCB suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 5 | Supply of 4 way MCB DB having 1 no. main incomer of 32A TPN MCB, Isc=10kA, Type C with 3 nos. of 16A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 12 nos. outgoing of 6A SPN MCB suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 6 | Installation, Testing and Commissioning of following configuration 415V, 3-phase, 4 wire, double door,with R Y B Phase indication and mcb position indication through glass front, IP-54, Prewired with HFFR/ FRLS copper wires, horizontal type, metallic Double Door, Phase Segregated three pole and neutral MCB Distribution Board fabricated out of 2 mm thick ,powder coated with RAL7035 shade , pre-galvanised G.I. sheet steel, suitable for surface mounting/ installation in existing enclosure complete with appropriate rating of tinned copper bus bar/ Cu wire, neutral bus bar, earth bar, din bar,brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes , neoprene gasket, etc as per drawing, specifications & generally as per relevant IS & as per instructions of Engineer-in-charge. |
| 7 | Installation, Testing and Commissioning of 8 way MCB DB having 1 no. main incomer of 32A TPN MCB, Isc=10kA, Type C with 3 nos. of 25A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 24 nos. outgoing of 6A SPN MCB suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 8 | Installation, Testing and Commissioning of 6 way MCB DB having 1 no. main incomer of 32A TPN MCB, Isc=10kA, Type C with 3 nos. of 25A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 18 nos. outgoing of 6A SPN MCB suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 9 | Installation, Testing and Commissioning of 4 way MCB DB having 1 no. main incomer of 32A TPN MCB, Isc=10kA, Type C with 3 nos. of 25A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 12 nos. outgoing of 16A SPN MCB suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 10 | Installation, Testing and Commissioning of 4 way MCB DB having 1 no. main incomer of 32A TPN MCB, Isc=10kA, Type C with 3 nos. of 16A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 12 nos. outgoing of 6A SPN MCB suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 11 | Supply of following configuration 240V, 1-phase, 2 wire, double door,with Phase indication and mcb position indication through glass front, IP-54, Prewired with HFFR/ FRLS copper wires, horizontal type, metallic Double Door, MCB Distribution Board fabricated out of 2 mm thick ,powder coated with RAL7035 shade , pre-galvanised G.I. sheet steel, suitable for surface mounting/ installation in existing enclosure complete with appropriate rating of tinned copper bus bar/ Cu wire, neutral bus bar, earth bar, din bar,brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes , neoprene gasket, check nuts etc as required as as per drawing, specifications & generally as per relevant IS & as per instructions of Engineer-in-charge. |
| 12 | Supply of MCB DB with Incomer of 32A, Isc=10kA, Type C, DP MCB and 8 nos. of 16A, Isc=10kA, Type C, DP Outgoing MCB feeder as per SLD and technical specification. |
| 13 | Supply of MCB DB with Incomer of 16A, Isc=10kA, Type C, DP MCB and 8 nos. of 10A, Isc=10kA, Type C, DP Outgoing MCB feeder as per SLD and technical specification. |
| 14 | Installation, Testing and Commissioning of following configuration 240V, 1-phase, 2 wire, double door,with Phase indication and mcb position indication through glass front, IP-54, Prewired with HFFR/ FRLS copper wires, horizontal type, metallic Double Door, MCB Distribution Board fabricated out of 2 mm thick ,powder coated with RAL7035 shade , pre-galvanised G.I. sheet steel, suitable for surface mounting/ installation in existing enclosure complete with appropriate rating of tinned copper bus bar/ Cu wire, neutral bus bar, earth bar, din bar,brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes , neoprene gasket, check nuts etc as required as as per drawing, specifications & generally as per relevant IS & as per instructions of Engineer-in-charge. |
| 15 | Installation, Testing and Commissioning of MCB DB with Incomer of 32A, Isc=10kA, Type C, DP MCB and 8 nos. of 16A, Isc=10kA, Type C, DP Outgoing MCB feeder as per SLD and technical specification. |
| 16 | Installation, Testing and Commissioning of MCB DB with Incomer of 16A, Isc=10kA, Type C, DP MCB and 8 nos. of 10A, Isc=10kA, Type C, DP Outgoing MCB feeder as per SLD and technical specification. |
| 17 | Supply of following LED light fittings complete with light fitting accessories, including supply and fixing SS accessories, PVC conduit bushes, Cu cable lugs, 3 inch pvc terminal box as per tender specification. |
| 18 | Supply of LED 4ft Batten, surface mounted fixture having system lumen output of 4400 lumens, minimum 110 lm/w system efficacy. The luminaire should have a CCT of 6500K and CRI>80, THD<10%, PF>0.95, L70B50 shall be 50000 hours , complete with light fitting SS accessories, flexible GI metallic conduit sleeves, Cu lugs, 3 inch pvc terminal box . The luminaire housing should have made of Polycarbonate with poly carbonate material which gives diffused light. The total power consumption should not exceed 40W (including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications. |
| 19 | Supply of light fitting, LED Recessed 2ft x 2ft type with a nominal system lumen output of 4200 lumens and a minimum system efficacy of 120 lm/W. The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF >0.95, L70B50 shall be 50000 hours, complete with light fitting SS accessories, flexible GI metallic conduit sleeves, Cu lugs, 3 inch pvc terminal box.The luminaire housing should have made of powder coated metallic CRCA with high efficiency optic diffuser.The total power consumption should not exceed 35W (including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications. |
| 20 | Supply of LED Square shape Recessed downlighter with a nominal system lumen output of 1500lm and a minimum system efficacy of 100lm/W. The luminaire should have a CCT of 6500K and CRI> 80. The luminaire shall meet IP20 rating with THD<10%, PF>0.90. The luminaire housing should made of white powder coated die-cast aluminium housing with high effeciency diffuser. The total power consumption should not exceed 15W (including BIS Compliant integrated driver). The luminaire shall be supplied with light fitting SS accessories, flexible GI metallic conduit sleeves, Cu lugs, 3 inch pvc terminal box. |
| 21 | Supply of LED Circular Recessed downlighter with a nominal system lumen output of 1800lm and a minimum system efficacy of 100lm/W. The luminaire should have a CCT of 6500K and CRI> 80. The luminaire shall meet IP20 rating with THD<10%, PF>0.9. The luminaire housing should made of white powder coated die-cast aluminium with high effeciency polycarbonate diffuser. The total power consumption should not exceed 18W (including BIS Compliant integrated driver).The luminaire shall be supplied with light fitting SS accessories, flexible GI metallic conduit sleeves, Cu lugs, 3 inch pvc terminal box. |
| 22 | Supply of LED Circular Recessed downlighter with a nominal system lumen output of 2400lm and a minimum system efficacy of 100lm/W. The luminaire should have a CCT of 5700K and CRI> 80. The luminaire shall meet IP20 rating with THD<10%, PF>0.90. The luminaire housing should made of white powder coated die-cast aluminium housing with high effeciency diffuser. The total power consumption should not exceed 24W(including BIS Compliant integrated driver). The luminaire shall be supplied with light fitting SS accessories, flexible GI metallic conduit sleeves, Cu lugs, 3 inch pvc terminal box. |
| 23 | Supply of LED street light fitting of not more than 35W having System Efficacy >120lm/W, system output >=4200 Lumens, THD<10%, Power Factor >=0.95, CRI >70, CCT 5700K, SDCM<5, IP66 protected pressure die cast aluminium housing having PC diffuser with IK08.The luminaire shall be supplied with pipe of suitable dia for mounting of the same. Luminaire shall sustain 325V/440V stress voltage protection for 8Hrs, HV cutoff: 325V/440V. Driver shall have 4KV Surge protection. Submission of LM80-08 for LED source & LM79-08 for Luminaire from NABL Accredited Lab mandatory. BIS certified. |
| 24 | Supply of LED 4ft Batten (approx dim. 75mm x 95mm x 1219mm) with a nominal system lumen output of 2500 lumens and a minimum system efficacy of 125 lm/W.The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD ≤ 10% and PF > 0.95. The luminaire housing should made of Extruded Aluminium with extruded PC diffuser. The total power consumption should not exceed 20W (including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications. The luminaire shall be supplied with light fitting SS accessories, flexible GI metallic conduit sleeves, Cu lugs, 3 inch pvc terminal box. |
| 25 | Supply of LED Bulkhead fitting (for exit lights & lift shaft) with a nominal system lumen output of 700 lumens and a minimum system efficacy of 105 lm/W. The luminaire should have a colour temperature of 6500K, CRI>80 and SDCM<5. The luminaire shall meet IP65 rating and IK08 rating with THD<20% and PF>0.9. The luminaire housing should made of Pressure Die Cast Aluminium with high quality PC diffuser. The power consumption should not exceed 6.5W (including driver). The driver shall have 2.5KV Surge protection. Submission of LM80-08 for LED source & LM79-08 for Luminaire from NABL Accredited Lab mandatory. BIS certified.The luminaire shall be supplied with light fitting SS accessories, flexible GI metallic conduit sleeves, Cu lugs, 3 inch pvc terminal box. |
| 26 | Installation, Testing and Commissioning of following LED light fittings complete with light fitting accessories, including supply and fixing SS accessories, PVC conduit bushes, Cu cable lugs as per tender specifiction. |
| 27 | Installation , Testing and commissioning of LED 4ft Batten, surface mounted fixture having system lumen output of 4400 lumens, minimum 110 lm/w system efficacy. The luminaire should have a CCT of 6500K and CRI>80, THD<10%, PF>0.95, L70B50 shall be 50000 hours , complete with light fitting SS accessories, flexible GI metallic conduit sleeves, Cu lugs, 3 inch pvc terminal box, . The luminaire housing should have made of Polycarbonate with poly carbonate material which gives diffused light. The total power consumption should not exceed 40W (including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications. |
| 28 | Installation, Testing and Commissioning of light fitting, LED Recessed 2ft x 2ft type with a nominal system lumen output of 4200 lumens and a minimum system efficacy of 120 lm/W. The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF >0.95, L70B50 shall be 50000 hours, complete with light fitting SS accessories, flexible GI metallic conduit sleeves, Cu lugs, 3 inch pvc terminal box.The luminaire housing should have made of powder coated metallic CRCA with high efficiency optic diffuser.The total power consumption should not exceed 35W (including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications. |
| 29 | Installation, Testing and Commissioning of LED Square shape Recessed downlighter with a nominal system lumen output of 1500lm and a minimum system efficacy of 100lm/W. The luminaire should have a CCT of 6500K and CRI> 80. The luminaire shall meet IP20 rating with THD<10%, PF>0.90. The luminaire housing should made of white powder coated die-cast aluminium housing with high effeciency diffuser. The total power consumption should not exceed 15W (including BIS Compliant integrated driver). The luminaire shall be installed with light fitting SS accessories, flexible GI metallic conduit sleeves, Cu lugs, 3 inch pvc terminal box. |
| 30 | Installation, Testing and Commissioning of LED Circular Recessed downlighter with a nominal system lumen output of 1800lm and a minimum system efficacy of 100lm/W. The luminaire should have a CCT of 6500K and CRI> 80. The luminaire shall meet IP20 rating with THD<10%, PF>0.9. The luminaire housing should made of white powder coated die-cast aluminium with high effeciency polycarbonate diffuser. The total power consumption should not exceed 18W (including BIS Compliant integrated driver).The luminaire shall be installed with light fitting SS accessories, flexible GI metallic conduit sleeves, Cu lugs, 3 inch pvc terminal box. |
| 31 | Installation, Testing and Commissioning of LED Circular Recessed downlighter with a nominal system lumen output of 2400lm and a minimum system efficacy of 100lm/W. The luminaire should have a CCT of 5700K and CRI> 80. The luminaire shall meet IP20 rating with THD<10%, PF>0.90. The luminaire housing should made of white powder coated die-cast aluminium housing with high effeciency diffuser. The total power consumption should not exceed 24W(including BIS Compliant integrated driver). The luminaire shall be installed with light fitting SS accessories, flexible GI metallic conduit sleeves, Cu lugs, 3 inch pvc terminal box. |
| 32 | Installation, Testing and Commissioning of LED street light fitting of not more than 35W having System Efficacy >120lm/W, system output >=4200 Lumens, THD<10%, Power Factor >=0.95, CRI >70, CCT 5700K, SDCM<5, IP66 protected pressure die cast aluminium housing having PC diffuser with IK08.The luminaire shall be supplied with pipe of suitable dia for mounting of the same. Luminaire shall sustain 325V/440V stress voltage protection for 8Hrs, HV cutoff: 325V/440V. Driver shall have 4KV Surge protection. Submission of LM80-08 for LED source & LM79-08 for Luminaire from NABL Accredited Lab mandatory. BIS certified. |
| 33 | Installation, Testing and Commissioning of of LED 4ft Batten (approx dim. 75mm x 95mm x 1219mm) with a nominal system lumen output of 2500 lumens and a minimum system efficacy of 125 lm/W.The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD ≤ 10% and PF > 0.95. The luminaire housing should made of Extruded Aluminium with extruded PC diffuser. The total power consumption should not exceed 20W (including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications. The luminaire shall be installed with light fitting SS accessories, flexible GI metallic conduit sleeves, Cu lugs, 3 inch pvc terminal box. |
| 34 | Installation, Testing and Commissioning of of LED Bulkhead fitting (for exit lights & lift shaft) with a nominal system lumen output of 700 lumens and a minimum system efficacy of 105 lm/W. The luminaire should have a colour temperature of 6500K, CRI>80 and SDCM<5. The luminaire shall meet IP65 rating and IK08 rating with THD<20% and PF>0.9. The luminaire housing should made of Pressure Die Cast Aluminium with high quality PC diffuser. The power consumption should not exceed 6.5W (including driver). The driver shall have 2.5KV Surge protection. Submission of LM80-08 for LED source & LM79-08 for Luminaire from NABL Accredited Lab mandatory. BIS certified.The luminaire shall be installed with light fitting SS accessories, flexible GI metallic conduit sleeves, Cu lugs, 3 inch pvc terminal box. |
| 35 | Supply of the following modular switches and plug sockets in the existing recess mounted GI box as per technical specification. |
| 36 | Supply of 2 nos. of 6A/16A (compatible with both 6A and 16A), Single phase Modular type socket with 16A switch for each socket and heavy duty Polycarbonate face plate, 2nos. of plug tops and suitable mounting arrangements as per technical specification. |
| 37 | Supply of 1 nos. of 6A/16A (compatible with both 6A and 16A), Single phase Modular type socket with 16A switch for each socket and heavy duty Polycarbonate face plate, 1nos. Of plug top and suitable mounting arrangements as per technical specification. |
| 38 | Installation, Testing and Commissioning of the following modular switches and plug sockets in the existing recess mounted GI box as per technical specification. |
| 39 | Installation, Testing and Commissioning of 1 nos. of 6A & 1nos. of 16A , Single phase Modular type socket with 1 nos. of 6A & 1 nos. of 16A switch for each socket and heavy duty Polycarbonate face plate, 2nos. Of plug tops and suitable mounting arrangements as per technical specification. |
| 40 | Installation, Testing and Commissioning of 1 nos. of 6A/16A (compatible with both 6A and 16A), Single phase Modular type socket with 16A switch for each socket and heavy duty Polycarbonate face plate, 1nos. Of plug top and suitable mounting arrangements as per technical specification. |
| 41 | Supply of the following Modular switches in the existing recess mounted GI box as per Technical specifications. |
| 42 | Supply of 2 nos. of 6A, Single Pole, Modular Switch with heavy duty polycarbonate face plate and suitable mounting arrangements as per technical specification. |
| 43 | Supply of 4 nos. of 6A, Single Pole, Modular Switch with heavy duty polycarbonate face plate and suitable mounting arrangements as per technical specification. |
| 44 | Supply of 1 nos. of 6A, Single Pole, Modular Switch with heavy duty polycarbonate face plate and suitable mounting arrangements as per technical specification. |
| 45 | Supply of the following Surface mounted switches with pre-galvanized powder coated GI Box, all accessories and mounting arrangement as per Technical specifications. |
| 46 | Installation, Testing and Commissioning of 2 nos. of 6A, Single Pole, Modular Switch with heavy duty polycarbonate face plate and suitable mounting arrangements as per technical specification. |
| 47 | Installation, Testing and Commissioning of 4 nos. of 6A, Single Pole, Modular Switch with heavy duty polycarbonate face plate and suitable mounting arrangements as per technical specification. |
| 48 | Installation, Testing and Commissioning of 1 nos. of 6A, Single Pole, Modular Switch with heavy duty polycarbonate face plate and suitable mounting arrangements as per technical specification. |
| 49 | Supply of switch box set consisting of 2nos. of 6A, Single Pole, Modular switch with polycarbonate box, heavy duty polycarbonate face plate suitable for surface mounting provided with mounting arrangements as per Technical specification. |
| 50 | Installation, Testing and Commissioning of switch box set consistingof 2nos. of 6A, Single Pole, Modular switch with polycarbonate box, heavy duty polycarbonate face plate suitable for surface mounting provided with mounting arrangements as per Technical specification. |
| 51 | Supply of switch box set consisting of 4nos. of 6A, Single Pole, Modular switch with polycarbonate box, heavy duty polycarbonate face plate suitable for surface mounting provided with mounting arrangements as per Technical specification. |
| 52 | Installation, Testing and Commissioning of switch box set consisting of 4nos. of 6A, Single Pole, Modular switch with polycarbonate box, heavy duty polycarbonate face plate suitable for surface mounting provided with mounting arrangements as per Technical specification. |
| 53 | Supply of 1nos. of 6A & 1nos. of 16A ,single phase Modular socket with polycarbonate/GI box as required, 1nos. of 6A & 1nos. 16A switch for each socket and heavy duty polycarbonate face plate, 2nos. of plug tops, suitable for surface mounting, provided with mounting arrangement as per technical specification. |
| 54 | Installation, Testing and Commissioning of 1nos. of 6A & 1nos. of 16A ,single phase Modular socket with polycarbonate/GI box as required, 1nos. of 6A & 1nos. 16A switch for each socket and heavy duty polycarbonate face plate, 2nos. of plug tops, suitable for surface mounting, provided with mounting arrangement as per technical specification. |
| 55 | Supply of 1 nos. of 6A Single phase Modular Decorative Type Weatherproof Socket with polycarbonate box , Switch and heavy duty polycarbonate Face Plate, plug tops and suitable mounting arrangements as per technical specification. |
| 56 | Installation, Testing and Commissioning of 1 nos. of 6A Single phase Modular Decorative Type Weatherproof Socket with polycarbonate box , Switch and heavy duty polycarbonate Face Plate, plug tops and suitable mounting arrangements as per technical specification. |
| 57 | Supply and embedment of heavy duty hot dipped GI conduit pipe as per IS 9537 along with all accessories such as inspection bends, junction box, socket, check nut, fish wire etc. including making threads, bends, removing burrs, connection of accessories, drawing of fish wire, beam and wall, cutting & Laying in brick wall, etc. as required under the instruction of Engineer-in-incharge. Surfacr mounted Junction box of suitable size as required suit at site shall be provided. |
| 58 | Supply of 25mm GI conduit |
| 59 | Fixing by surface conduiting of 16SWG heavy duty Class-B Galvanised steel (G.I.) ERW conduit pipe of following sizes along with all accessories such as inspection bends, junction box, socket, check nut, etc. including making threads, removing burrs, connection of accessories, cleating with heavy duty GI saddles or suit to site clamps on RCC wall, column, steel structural, etc. as required under the instruction of Engineer-in-incharge. Surface type junction box shall be provided. |
| 60 | Installation of 25mm GI conduit |
| 61 | Supply and laying of 14SWG tinned solid copper conductor throughout along the conduit including fixing with ties, brazing etc as required. |
| 62 | Supply |
| 63 | Installation |
| 64 | Supply of following size flexible Galvanized steel PVC coated conduit pipe including cleating with heavy duty GI saddles or suit to site clamps on RCC wall, column, steel structure, etc. as required under the instruction of Engineer-in-charge and as per tender specification. |
| 65 | Supply of flexible Galvanized steel PVC coated conduit pipe of size 26 MM |
| 66 | Supply of flexible Galvanized steel PVC coated conduit pipe of size 50 MM |
| 67 | Installation of following size flexible Galvanized steel PVC coated conduit pipe including cleating with heavy duty GI saddles or suit to site clamps on RCC wall, column, steel structure, etc. as required under the instruction of Engineer-in-charge and as per tender specification. |
| 68 | Installation of flexible Galvanized steel PVC coated conduit pipe of size 26 MM |
| 69 | Installation of flexible Galvanized steel PVC coated conduit pipe of size 50 MM |
| 70 | Supply and Installation of 38mmx16mmx1.2mm PVC Casing capping with all fixtures and accesseries (Bends, joints, saddles, screws. etc. ) |
| 71 | Supply |
| 72 | Installation |
| 73 | Supply and Installation of 25mmx16mmx1.2mm PVC Casing capping with all fixtures and accesseries (Bends, joints, saddles, screws. etc. ) |
| 74 | Supply |
| 75 | Installation |
| 76 | Supply and Installation of 50mmx50mmx1.5mm PVC Casing capping with all fixtures and accesseries (Bends, joints, saddles, screws. etc. ) |
| 77 | Supply |
| 78 | Installation |
| 79 | Supply of Single Core HFFR wires (Copper) of size mentioned below in voltage grade 1100V as per the IS 17048: 2018 (latest edition) and as per conductor class 2 of IS: 8130/1984 as per technical specification |
| 80 | Supply of Single Core HFFR wires (Copper) of size 1.5 Sq.mm |
| 81 | Supply of Single Core HFFR wires (Copper) of size 2.5 Sq.mm |
| 82 | Installation/drawing through concealed/ surface conduit and wiring and termination at both ends of Single Core HFFR wires (Copper) of size mentioned below in voltage grade 1100V as per the IS 17048: 2018 as per conductor class 2 of IS:8130/1984 as per technical specification. |
| 83 | Installation/drawing of Single Core HFFR wires (Copper) of size 1.5 Sq.mm |
| 84 | Installation/drawing of Single Core HFFR wires (Copper) of size 2.5 Sq.mm |
| 85 | Supply and surface/concealed laying including making chasing on wall of 10 sq. mm stranded tinned coper conductor, connection with earth pad at one end and DBs/ sockets/ motor at other end including clamping/ cleating on surface/ floor/ ceiling/ wall/ tray, making chase, repairing the same, connection through brazing/ bolting etc. as per instructions by Engineer-In-Charge. |
| 86 | Supply of 10 sq. mm stranded tinned coper conductor |
| 87 | Installation of 10 sq. mm stranded tinned coper conductor |
| 88 | Supply and surface/concealed laying of 2 x 10 sq. mm Cu PVC insulated earthing conductor in 25mm HDPE pipe including clamping/ cleating on surface/ floor/ ceiling/ wall/ tray, making chase, repairing the same, connection through brazing/ bolting etc. as per instructions by Engineer-In-Charge. |
| 89 | Supply |
| 90 | Installation |
| 91 | Supply of 25mm HDPE pipe as per tender specifications. |
| 92 | Supply and installation of tinned Cu Lugs and Brass bolt suitable to following sizes of earthing conductors as per attached technical specification |
| 93 | 10 Sq.mm stranded tinned copper conductor |
| 94 | Supply and installation of M10 brass bolt, 3/4\\" long suitable for 10mm threaded hole for making connection to earth pad. |
| 95 | Supply of Busbar Insulator of size M8 x 40mm, MOC: Epoxy as per tender specification. |
| 96 | Installation of Busbar Insulator of size M8 x 40mm for fixing of downcomer conductor from lightening arrestor as per tender specification. |
| 97 | Supply and Installation of 25 mm X 3 mm thick copper strip including connection/ terminating with nut, bolt, spring, washer etc. as required. |
| 98 | Supply of 25 mm X 3 mm thick copper strip |
| 99 | Installation & Testing of 25 mm X 3 mm thick copper strip |
| 100 | Supply and Installation of GI C- clamp of size 25x3mm, length 200mm having suitable size of hole for fixing of Cu strip. |
| 101 | Supply and fixing vertical air termination made up of 20mm dia, 1mtr long copper rod attached to 145mm dia Copper sphere having drilled and tapped holes for fixing 5nos. Of 390mm long spikes and square copper base plate of 150mm length and 10mm thickness as per technical specification and approved drawing. |
| 102 | Supply of vertical air termination |
| 103 | Installation of vertical air termination |
| 104 | Supply and Installation of 1.2 mm thick pre-galvanized GI sheet cover plates including marking, cutting (as per site requirement) and fixing on top of JB openings in wall and slab bottom/ ceiling at approx height of 5mtrs as per tender specifications. |
| 105 | Supply of Single phase heavy duty exhaust fan of sweep 300mm with FRP duct suitable for domestic application as per Tender specification. |
| 106 | Installation, Testing and commissioning of Single phase heavy duty exhaust fan of sweep 300mm with FRP duct suitable for domestic application. |
| 107 | Supply, Installation, Testing and Commissioning of new energy efficient High Grade ABS Basic Hand Dryers, wall mounted, 1800Watt or above, Touch free Infra-red Sensor activation, AC220-240V, 50/60Hz and as per tender technical specifications. |
| 108 | Supply and Installation of 400mm sweep wall mounting fan suitable to operate at single phase 230V AC supply having minimum 3 levels of speed control. The supply and installation of fan shall be completed with all the accessories and spares as required. |
| 109 | Supply |
| 110 | Installation, Testing and Commissioning |
| 111 | Black painted Extruded aluminium housing single sided 8W LED signage exit light, Red LEDs mounted inside the housing, Laser engraved Signage matter on Single/Double Acrylic sheet fixed on one side along with Ni-Cd Battery back up to 2hrs (charged up to 8 - 10 Hrs), mounting strings provided for pendant mounting, operating voltage 150-280V AC and ingress protection- IP42. |
| 112 | Supply |
| 113 | Installation, Testing and Commissioning |
| 114 | Supply of 52-port (48x1 Gbps RJ-45 Copper port, 4x1/10 Gbps SFP port) smart web-managed layer-2 network switch with mounting accessories |
| 115 | Installation, testing, commissioning of 52-port (48x1 Gbps RJ-45 Copper port, 4x1/10 Gbps SFP port) smart web-managed layer-2 network switch with mounting accessories |
| 116 | Supply of 28-port (24x1 Gbps RJ-45 Copper port, 4x1/10 Gbps SFP port) smart web-managed layer-2 network switch with mounting accessories |
| 117 | Installation, testing, commissioning of of 28-port (24x1 Gbps RJ-45 Copper port, 4x1/10 Gbps SFP port) smart web-managed layer-2 network switch with mounting accessories |
| 118 | Supply of Industrial grade 10-port (8x1 Gbps RJ-45 Copper port, 2x1/10 Gbps SFP port) POE+ layer-2 ethernet network switch along with power supply arrangement and mounting accessories |
| 119 | Installation, testing, commissioning of Industrial grade 10-port (8x1 Gbps RJ-45 Copper port, 2x1/10 Gbps SFP port) POE+ layer-2 ethernet network switch along with power supply arrangement and mounting accessories |
| 120 | SITC of 1Gbps Single Mode (SFP) 1000BASE-LX LC transreciever Module compatible with supplied ethernet switches. |
| 121 | SITC of Fully Loaded drawout type, LC type 24-port Fiber Distribution (LIU)System of 1U size suitable for mounting in 19\\" rack. |
| 122 | SITC of 24-Port CAT6 Patch panel of 1U size suitable for 19\\" rack fully loaded with all wiring support accessories inclduing RJ45 connectors. |
| 123 | SITC of 4-modular PVC box including cover plate, face plate with 2 nos. of RJ11(4 Pin) connector with shutter telephone socket and 2 nos of RJ45 socket (UTP/STP) with shutter and connector |
| 124 | Supply of 9U wall mount network rack of 19\\" size side openable with minimum 2 cooling fans(90 cfm), 5 socket PDU, 2 cable manager and fully loaded with all accessories |
| 125 | Installation, testing, commissioning of 9U wall mount network rack of 19\\" size side openable with minimum 2 cooling fans(90 cfm), 5 socket PDU, 2 cable manager and fully loaded with all accessories |
| 126 | Supply of 9U outdoor IP66 network rack of 19\\" size fully loaded with all accessories |
| 127 | Installation, testing, commissioning of 9U outdoor IP66 network rack of 19\\" size fully loaded with all accessories |
| 128 | Supply of 32U Floor standing rack fully loaded with all accessories |
| 129 | Installation, testing, commissioning of 32U Floor standing rack fully loaded with all accessories |
| 130 | Supply of 23AWG CAT6 Armoured UTP cable LSZH type |
| 131 | Laying of 23AWG CAT6 Armoured UTP cable LSZH type |
| 132 | Supply of 23AWG CAT6 unarmoured UTP cable LSZH type |
| 133 | laying of 23AWG CAT6 unarmoured UTP cable LSZH type |
| 134 | Supply of 2 pair, 0.5 mm dia., copper conductor, unarmoured telephone cable as per attached specifications. |
| 135 | Laying of 2 pair, 0.5 mm dia., copper conductor, unarmoured telephone cable as per attached specifications. |
| 136 | Supply and Installation of CAT6 Patch cords, 1 Mtr |
| 137 | Supply and installation of CAT6 Patch cords, 2 Mtr |
| 138 | Supply and installation of LC-LC SM Duplex Fiber Patchcords 2 meter length. |
| 139 | Supply and installation of LC-LC SM Duplex Fiber Patchcords 5 meter length. |
| 140 | Supply and installation of LC-LC SM Duplex Fiber Patchcords 15 meter length. |
| 141 | Supply of 24-core Armoured Single Mode (9/125 um) Multi-tube loosely buffered Fiber optic cable |
| 142 | Laying of 24-core Armoured Single Mode (9/125 um) Multi-tube loosely buffered Fiber optic cable through HDPE pipe. |
| 143 | Supply of HDPE pipe 40 mm along with all accessories like bends, couplers etc, fitting, cutting and jointing etc. |
| 144 | Laying of HDPE pipe 40 mm along with all accessories like bends, couplers etc, fitting, cutting and jointing etc. |
| 145 | Fiber optic splicing and termination of connections |
| 146 | SITC of 32-Channel NVR with 1080p resolution support and H.265 or better decoding with minimum 20 TB storage capacity and Supply of Central Video management software for integrated view of NVRs |
| 147 | SITC of 10TB surveillance grade HDD storage disk for CCTV |
| 148 | SITC of Indoor IP based 2 MP vandal resistant(IK10) Dome IR camera(POE) along with mounting accessories and junction box |
| 149 | SITC of Outdoor IP based 4 MP Motorised Focused Zoom(MFZ) varifocal IR Bullet camera(POE) along with mounting accessories and outdoor weatherproof junction box |
| 150 | SITC of Outdoor IP based 2 MP WDR IR PTZ(Pan-tilt-Zoom) POE camera (25x or better optical zoom) with mounting accessories and outdoor weatherproof junction box |
| 151 | Supply laying of 32 mm flexible Galvanised steel PVC coated conduit with all fixtures |
| 152 | SITC of 55\\" professional display for CCTV surveillance |
| 153 | SITC of small form factor/mini PC 16GB RAM/512GB SSD for CCTV surveillance with supply of HDMI/DP connector and 15 meter optical HDMI cable compatible with 55\\" professional display |
| 154 | Supply, installation, commissioning of 4K 75\\" LEDDisplay |
| 155 | Supply, installation, commissioning of Full HDCodec with minimum 1+8 multi site capability Audio Video Conferencing System |
| 156 | Supply, installation, commissioning of 4x opticalzoom PTZ camera for above Video conferencingsystem |
| 157 | Supply, installation, commissioning of Wired tabletop microphone(mic) with echo cancellation withmute button and LED as status indicator compatiblewith above codec |
| 158 | Supply, installation, commissioning of Mixer for 8mic inputs and 2 mic output(8x2) compatible withabove codec |
| 159 | Supply, installation, commissioning of 5.1 channelsurround speaker system(220W minimum)compatible with above codec |
| 160 | Supply, installation, commissioning of portableconsole for conferencing(14 inch, 8 GB RAM, 512GBSSD or better) |
| 161 | Supply, installation, commissioning of 4K HDMI 1x4Splitter |
| 162 | Supply, installation, commissioning of Fiber opticHDMI cable 20 meter length |
| 163 | supply, installation, commissioning of 4x4 USBswitcher with 2 set of 10 meter USB cable |
| 164 | Supply, installation, commissioning of Cordlesstelephone |
| 165 | Supply, installation of (Approx. 1.25 meter(L) x 1meter(W) x 2 mm(thick)) printed display board forconference room |
| 166 | Supply installation of Wall mount and Desktop type Analog Telephone Instruments with alphabet and Numerical Caller ID facility |
| 167 | Supply of 24-core armoured cable OFC Splicing jointing kit for cable |
| 168 | Installation of 24-core armoured cable OFC Splicing jointing kit for cable along with OTDR reports |
| 169 | Excavation in all type of soils of width as specified in the technicals specification at approx. depth of 1000mm below ground level, sand bedding, laying of bricks on side and top,backfilling ,dewatering, consolidation, shoring, disposal of excess earth, Item includes supply of sand and class- 1 bricks |
| 170 | Supply, Installation and Commissioning, Warranty, Training & Guarantee of Fire Alarm System (FAS). Single loop with CPU based Intelligent, Addressable, Modular, and Networkable Fire Alarm panel with Display, along with loop & power cables routing & termination provisions. It should be compatible with existing fire alarm panels for networking and repeatation of zone alarms at central location. GUI and Panel programming, development and runtime software with perpetual licenses to be provided. |
| 171 | Supply, Installation, testing and commissioning of Intelligent multi-sensor (Smoke & Heat) detector with built-in Isolators, bases & suitable mounting arrangement. |
| 172 | Supply,Installation, testing and commissioning of Addressable break glass Manual Call Point units with bases and two spare glass elements. |
| 173 | Supply, installation, commissioning of Sounder cum strobe with base. |
| 174 | Supply of 1 pair (2-core) x 1.5mm2, stranded copper conductor, twisted , FRLS and Zero Halogen, armoured, overall screened, sheathed, 1100 Volts grade loop cable. |
| 175 | Laying of 1 pair (2-core) x 1.5mm2, stranded copper conductor, twisted , FRLS and Zero Halogen, armoured, overall screened, sheathed, 1100 Volts grade loop cable. |
| 176 | Supply, installation, testing, commissioning of Key access management system (Minimum 48 Nos. of key) with RFID card access and inbuilt control unit for RFID card enrolment of as per technical specifications. |
| 177 | Supply, installation, commissioning of Modular Conference Table(Approx. 1250(L) mm x 600(w)mm) with melamine top and steel supports as per tender specifications. |
| 178 | Supply, installation, commissioning of Modular Carpet Flooring providing Acoustic properties as per tender specifications. |
| 179 | Supply, installation, commissioning of Melamine top storage cabinet(300 mm(Depth) x 1200 mm(Height)) with shelves as per tender specification. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysOct 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender