Tender For Provision Of Certain Miscellaneous E/M Minor Works At Af Station Amritsar Under Age (I) Af Amritsar
Tender Overview
Project Description
Tender For Provision Of Certain Miscellaneous E/M Minor Works At Af Station Amritsar Under Age (I) Af Amritsar- 1 M&L Flame Proof, Zone I & Ii , Gas Group Ii A/ Ii B, Weather Proof Point Wiring For One Light Or Fan Point Controlled By One Switch Using Approved Colour Coding As Per Is With Halogen Free Flame Retardant (Hffr) Smoke Free Non Toxic Non Corrosive Pvc Insulated Unsheated Flexible Copper Conductor Cable 1.5 Sq Mm (Nominal Area) Single Core 1100 Volts Grade In And Including 20 Mm Dia (Erw) Stove Enamelled Conduit Heavy Duty Isi Marked Duly Welded, Flame Proof Weather Proof Junction Box , Tee, Bends, Inspection Bends Etc All As Required Including Hffr Unsheated Flexible Copper Conductor Cable 1.5 Sq Mm (Nominal Area) Single Core 1100 Volts Grade As Earth Continuity Conductor Complete All As Specified And Directednote:- Including New Enamelled (Erw) Conduit Chasing And With New Sunken Boxes And Making Good Of Surfaces 2 M&L Flame Proof, Zone I & Ii , Gas Group Ii A/ Ii B, Flameproof/Weatherproof Rotary On/Off Switch 10/16A Along With Complete All As Specified And Directed. 3 S&F Of Flame Proof Exaust Fan Heavy Duty (300Mm Sweep), 230V, 1440 Rpm, 1120Cfm Wall Mounted/Window Mounted Metal Body Type And Including With All Fixing Arrangement Fixed To Wall With Suitable Size Opening And Mounting Ring And Louvre Complete With All Accessories Pre-Wired And Including Connection, Complete All As Specified & Directed. 4 S& F Of Ceiling Rose With Plug-In Connection - 4 Pin White - Fire Resistant Complete All As Specified And Directed 5 Cutting Opening, Through Brick Walls For Door, Window, Exhaust Fan Openings And Other Openings And Making Good The Surfaces Complete All As Specified And Dirceted 6 Supply And Fixing Flameproof Tube Light Fixture Cmri Certified Led Flameproof Batten Suitable For Single Tube, Of 16 Or 20 Watts, Used For Gas / Vapor Group Of Iia And Iib & Zone 1 & 2. The Flameproof Led Light Fitting With An Ingress Protection Of Ip65 Complete As Specified And Direcetd. 7 Material And Labour Of Point Wiring Concealed Type With Pvc Insulated (Sheathed) Cable 1.5 Sqmm (Nominal Area) Multy Stranded Frls Copper Conductor 1100 Volts Grade And Continous Earth Wire Pvc Insulated 1.5 Sqmm Copper Conductor To Common Earth In And Including New Pvc Complete All As Specified And Directed By Engineer-In-Charge For The Following 8 One Light Point Or One Fan Point Controlled By One Switch With Cables 1.5 Sq. Mm Size 9 Material And Labour Of Point Wiring Concealed Type With Pvc Insulated (Sheathed) Cable 2.5 Sqmm (Nominal Area) Multy Stranded Frls Copper Conductor 1100 Volts Grade And Continous Earth Wire Pvc Insulated 2.5 Sqmm Copper Conductor To Comman Earth In And Including New Pvc Complete All As Specified And Directed By Engineer-In-Charge For The Following 10 One Light Point Or One Fan Point Controlled By One Switch With Cables 2.5 Sq. Mm Size → 11 Supply And Fixing Of Ceiling Rose, Surface Bakelite, 65 X 50 Mm, 3 Terminals Complete All As Specified And Directed. 12 M&L Of Modular Switch 1 Way 16A,1 Module Complete All As Specified And Directed. 13 Supply And Fix Of Metal Flush Box 3 Module Complete All As Specified And Directed. 14 Supply And Fix Of White Cover Plate With Frame, 3 Module Complete All As Specified And Directed. 15 Supply & Fixing Of Socket 6A/16A - 2/3 Pin Combined 2 Module All As Specified And Directed 16 M&L Of Modular Switch 1 Way 6A,1 Module Complete All As Specified And Directed. 17 Supply And Fix Of Metal Flush Box 1/2 Module,Complete All As Specified And Directed. 18 Supply And Fix Of White Cover Plate With Frame, 1 Module Complete All As Specified And Directed. 19 Material And Labour Of Xlpe Insulated, Armoured Heavy Duty Electric Cable With Aluminium Conductor, 1100 Volts Grade, Cross-Sectional Area 16 Sqmm, 4 Core As Specified And Directed 20 Supply And Fixing 240V, 10 Ka C Curve Miniature Circuit Breaker (Mcb) Of Single Poles And Current Carrying Capacity 5 To 32 Amp, In The Mcb Db Complete With Connection Testing And Commissioning Complete All As Specified And Directed 21 Cutting Chases, Pinning In. Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc., And Making Good, Cutting Exc 10 Cm But Not Exc 20 Cm Girth All As Specified And Directed 22 Supply & Fixing Of Single Pole And Neutral Enclosure With A Two Pin And Earth Plug And Socket Complete With One Single Pole Mcb All As Specified And Directed 23 Supply & Fixing Of Wall Fan Heavy Duty (300Mm Sweep), 230V, 1400 Rpm, Wall Mounted Metal Body Type (100% Copper Wound And Minimum 2 Year Guarantee) And Including With All Fixing Arrangement Fixed To Wall Complete With All Accessories Pre-Wired And Including Connection, Complete All As Specified & Directed. 24 Supply & Fixing Of Exaust Fan Heavy Duty (300Mm Sweep), 230V, 1440 Rpm, Wall Mounted/Window Mounted Metal Body Type And Including With All Fixing Arrangement Fixed To Wall With Suitable Size Opening And Mounting Ring And Louvre Complete With All Accessories Pre-Wired And Including Connection, Complete All As Specified & Directed. 25 Supply & Fixing Of Exaust Fan Heavy Duty (450Mm Sweep), 230V, 1440 Rpm, Wall Mounted/Window Mounted Metal Body Type And Including With All Fixing Arrangement Fixed To Wall With Suitable Size Opening And Mounting Ring And Louvre Complete With All Accessories Pre-Wired And Including Connection, Complete All As Specified & Directed. 26 S&F High Density Poly- Ethylene Pipes 50 Mm Bore (Hdpe) Of Pressure Rating 6 Kgf/Cm2 Laid In Trenches Complete All As Specified And Directed 27 Supply And Fixing Aluminium Lugs/Ferrule Suitable For Lt Ug Cable,1100V For The 16 Sqmm Cable As Specified And Directed 28 M&L For Xlpe Insulated, Armoured Heavy Duty Electric Cable With Aluminium Conductor, 1100 Volts Grade, Cross-Sectional Area 16 Sq. Mm 4 Core As Specified And Directed 29 Pure Copper Lightning Arrester With 5 Spikes, 9.2Mm Diameter, 980Mm Length, 85Mm Base Plate For Building And Home With Necessary Foundation Of Cement Concrete As Specified And Directed 30 Material And Labour Of Copper Strip 20 X 3.15Mm With Saddles And Fixing Screws Etc. For Roof Conductors And Down Conductors Above Ground As Specified And Directed 31 Material And Labour Of Brazing Of Copper Srip 20X3.15Mm With Saddles And Fixing Screws Etc. For Roof Conductors And Down Conductors Above Ground As Specified And Directed. 32 Material & Labor For Earthing Complete With Copper Plate Buried Directly In Ground (Earth Pit Not Less Than 2.25 Metres Deep Below Groundlevel) With Top Edge Of The Plate Not LessThan 1.5 Metres Below Normal Ground Level, Connected Using Copper Plate 60×60Cm ×3.15Mm Thick Electrode And 20×3Mm Copper Strip As Earthing Leadby Means Of Bolts, Nuts, Check Nuts And Washers Of Brass All As Shown In Electrical Plate No. 3 Connected To Earthing Test Point All As Specified Or Indicated Including Testing On Completion As Specified And Directed 33 Demolition Of Cement Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided For, As Specified And Directed 34 Excavating In Trenches Soft Soil, N Exc 1.5 M Wide And N Exc 1.5 M In Depth; For Foundation,Etc. N Exc 10 Sq M On Plan And N Exc 1.5 M In Depth And Getting Out, As Specified And Directed 35 Removing Excavated Material N Exc. 50M And Depositing Where Directed At A Level N Exc. 1.5 M Complete All As Directed By Engr-In-Charge 36 M&L Of Sand Filling Under Floors Or In Foundations Including Watering And Consolidation, As Specified And Directed 37 Material Supply Only Locally Available , Sub Class B Bricks (Old Size) Laid Flat And Dry In Trenches Over The Cable For Protection Prependicular To The Direction Of Cable Adjacent To Each Other Complete All As Specified And Directed. 38 Material And Labour For Cement Concrete Type C- 2, 1:3:6 (40Mm Graded Aggregate) 150Mm Thick All As Specified And Directed 39 Material And Labour For Cement Concrete Type B- 2, 1:2:4 (40Mm Graded Aggregate) 150Mm Thick All As Specified And Directed 40 Supply And Install High Wall Split Units Indoor/Outdoor Complete With Cordless Remote Control Unit And With In Built Air Ioniser And Plasma Filter For Better Indoor Air Quality With Minimum 5 Star Rating And Eer 3.2.Of Capacity 1.5 Tr Complete All As Specified And Directed 41 S&F For Sub Main Wiring Two Run Single Core 4 Sqmm(Nominal Area) Multi-Strand Copper Conductor Fr Pvc Insulated Cable Drawn In And Including Non Metalic Pvc Regid Conduit Medium Grade Of Suitable Size With All Standerd Fittings, Concealed Including One Run Of Continous Pvc Insulated Stranded Copper Conductor Fr Cable 2.5 Sqmm For Earth Continuty, Including Taking Out And Removal Of Old Sub Main Wiring, Complete All As Specified And Directed.Note:- (I) Two Run Of 4Sqmm Main Cable + One Run Of 2.5 Sqmm Cable For Earth Continuty And Pvc Conduit Shall Be Measured As One Unit/One Running Meter Complete All As Specified And Directed. 42 Supply And Fix Of Sheet Metal Encloser Single Pole And Neutral , With Two Pin And Earth Plug And Socket Complete With One Single Pole Mcb 20 Amp Complete All As Specified And Directed
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 15-Oct-2026 | CORRIGENDUM NO 1 | Date | 02-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | M&L flame proof, Zone I & II , Gas Group II A/ II B, weather proof point wiring for one light or fan point controlled by one switch using approved colour coding as per IS with Halogen Free Flame Retardant (HFFR) smoke free non toxic non corrosive PVC insulated unsheated flexible copper conductor cable 1.5 sq mm (nominal area) single core 1100 volts grade in and including 20 mm dia (ERW) stove enamelled conduit heavy duty ISI marked duly welded, flame proof weather proof junction box , tee, bends, inspection bends etc all as required including HFFR unsheated flexible copper conductor cable 1.5 Sq mm (nominal area) single core 1100 volts grade as earth continuity conductor complete all as specified and directedNote:- including new Enamelled (ERW) conduit chasing and with new sunken boxes and making good of surfaces |
| 2 | M&L flame proof, Zone I & II , Gas Group II A/ II B, Flameproof/Weatherproof Rotary On/Off Switch 10/16A along with complete all as specified and directed. |
| 3 | S&F of flame proof Exaust fan Heavy duty (300mm sweep), 230V, 1440 RPM, 1120CFM wall mounted/window mounted metal body type and including with all fixing arrangement fixed to wall with suitable size opening and mounting ring and louvre complete with all accessories pre-wired and including connection, complete all as specified & directed. |
| 4 | S& F of Ceiling rose with plug-in connection - 4 pin white - fire resistant complete all as specified and directed |
| 5 | Cutting opening, through brick walls for door, window, exhaust fan openings and other openings and making good the surfaces complete all as specified and dirceted |
| 6 | Supply and Fixing Flameproof Tube light fixture CMRI certified LED flameproof batten suitable for single tube, of 16 or 20 watts, used for Gas / Vapor group of IIA and IIB & Zone 1 & 2. The flameproof LED Light fitting with an ingress protection of IP65 complete as specified and direcetd. |
| 7 | Material and labour of point wiring concealed type with PVC insulated (sheathed) cable 1.5 Sqmm (Nominal area) multy stranded FRLS Copper conductor 1100 volts grade and continous earth wire PVC insulated 1.5 sqmm copper conductor to common earth in and including new PVC complete all as specified and directed by Engineer-in-charge for the following |
| 8 | One light point or one fan point controlled by one switch with cables 1.5 sq. mm size |
| 9 | Material and labour of point wiring concealed type with PVC insulated (sheathed) cable 2.5 Sqmm (Nominal area) multy stranded FRLS Copper conductor 1100 volts grade and continous earth wire PVC insulated 2.5 sqmm copper conductor to comman earth in and including new PVC complete all as specified and directed by Engineer-in-charge for the following |
| 10 | One light point or one fan point controlled by one switch with cables 2.5 sq. mm size → |
| 11 | Supply and fixing of ceiling rose, surface bakelite, 65 X 50 mm, 3 terminals complete all as specified and directed. |
| 12 | M&L of Modular switch 1 way 16A,1 module complete all as specified and directed. |
| 13 | Supply and Fix of Metal flush box 3 module complete all as specified and directed. |
| 14 | Supply and Fix of White cover plate with frame, 3 module complete all as specified and directed. |
| 15 | Supply & Fixing of Socket 6A/16A - 2/3 pin combined 2 module all as specified and directed |
| 16 | M&L of Modular switch 1 way 6A,1 module complete all as specified and directed. |
| 17 | Supply and Fix of Metal flush box 1/2 module,complete all as specified and directed. |
| 18 | Supply and Fix of White cover plate with frame, 1 module complete all as specified and directed. |
| 19 | Material and labour of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm, 4 Core as specified and directed |
| 20 | Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed |
| 21 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10 cm but not exc 20 cm girth all as specified and directed |
| 22 | Supply & Fixing of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB all as specified and directed |
| 23 | Supply & Fixing of Wall fan Heavy duty (300mm sweep), 230V, 1400 RPM, wall mounted metal body type (100% copper wound and minimum 2 year Guarantee) and including with all fixing arrangement fixed to wall complete with all accessories pre-wired and including connection, complete all as specified & directed. |
| 24 | Supply & Fixing of Exaust fan Heavy duty (300mm sweep), 230V, 1440 RPM, wall mounted/window mounted metal body type and including with all fixing arrangement fixed to wall with suitable size opening and mounting ring and louvre complete with all accessories pre-wired and including connection, complete all as specified & directed. |
| 25 | Supply & Fixing of Exaust fan Heavy duty (450mm sweep), 230V, 1440 RPM, wall mounted/window mounted metal body type and including with all fixing arrangement fixed to wall with suitable size opening and mounting ring and louvre complete with all accessories pre-wired and including connection, complete all as specified & directed. |
| 26 | S&F High density poly- ethylene pipes 50 mm bore (HDPE) of pressure rating 6 kgf/cm2 laid in trenches complete all as specified and directed |
| 27 | Supply and fixing Aluminium lugs/ferrule suitable for LT UG Cable,1100V for the 16 sqmm cable as specified and directed |
| 28 | M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 4 core as specified and directed |
| 29 | Pure Copper Lightning Arrester with 5 Spikes, 9.2mm Diameter, 980mm Length, 85mm Base Plate for Building and Home with necessary foundation of cement concrete as specified and directed |
| 30 | Material and labour of Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground as specified and directed |
| 31 | Material and labour of brazing of copper srip 20x3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground as specified and directed. |
| 32 | Material & Labor for Earthing complete with copper plate buried directly in ground (earth pit not less than 2.25 metres deep below groundlevel) with top edge of the plate not less'than 1.5 metres below normal ground level, connected using copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing leadby means of bolts, nuts, check nuts and washers of brass all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion as specified and directed |
| 33 | Demolition of Cement concrete of any description and in any position not otherwise specifically provided for, as specified and directed |
| 34 | Excavating in trenches soft soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation,etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out, as specified and directed |
| 35 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m complete all as directed by Engr-in-Charge |
| 36 | M&L of Sand filling under floors or in foundations including watering and consolidation, as specified and directed |
| 37 | Material supply only locally available , sub class 'B' bricks (old size) laid flat and dry in trenches over the cable for protection prependicular to the direction of cable adjacent to each other complete all as specified and directed. |
| 38 | Material and labour for Cement concrete type C- 2, 1:3:6 (40mm graded aggregate) 150mm thick all as specified and directed |
| 39 | Material and labour for Cement concrete type B- 2, 1:2:4 (40mm graded aggregate) 150mm thick all as specified and directed |
| 40 | Supply and install high wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR complete all as specified and directed |
| 41 | S&F for sub main wiring two run single core 4 Sqmm(nominal area) multi-strand copper conductor FR PVC insulated cable drawn in and including non metalic PVC regid conduit medium grade of suitable size with all standerd fittings, concealed including one run of continous PVC insulated stranded copper conductor FR cable 2.5 sqmm for earth continuty, including taking out and removal of old sub main wiring, complete all as specified and directed.Note:- (i) Two run of 4sqmm main cable + one run of 2.5 sqmm cable for earth continuty and PVC conduit shall be measured as one unit/one running meter complete all as specified and directed. |
| 42 | Supply and fix of sheet metal encloser single pole and neutral , with two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed |
| 43 | S&F of Air Conditioning Changeover Timer, Automatic AC on/Off Timer, AC Cyclic Timer Switch, Microprocessor based with delay 2-4 hours (16 Amp) complete all as specified and directed. |
| 44 | Supply and fix Voltage stabilizer for automatic operation, copper wound, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed. |
| 45 | Note: The Total amount shall subject to adjustment of credit for old Materials as per Schedule of Credit. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 16 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender