Tender For Provn Of Approach Path And Chain Link Fencing To Tropo Tower, Provn Of Parking Shed In Indrayani, Addn/ Altn To Garbage Bins And Approach Path, Provn Of Galvalume Sheet Roof With Steel Shed And Covered With Chain Link Fencing Around The Af
Tender Overview
Project Description
Tender for Provn Of Approach Path And Chain Link Fencing To Tropo Tower, Provn Of Parking Shed In Indrayani, Addn/ Altn To Garbage Bins And Approach Path, Provn Of Galvalume Sheet Roof With Steel Shed And Covered With Chain Link Fencing Around The Afcel Tower, Improvement To Internal, External And Steel Surface Painting To Drill Shed (P-110) At Af Stn Lonavla (8487/E8)
BOQ
| Sl. No. | Item Description |
| 1 | Site clearance to construction of fencing around the considered area including removing obstacles like trees/plants , vegetation, rocks, ensuring a safe and accessible work complete all as specified |
| 2 | Excavation in trenches, n exc 1.50 mtr wide and n exc 1.50 mtr in depth, for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 Sqm on plan and n exc 1.50 mtr in depth and getting out in Soft loose soil complete all as specified. |
| 3 | Returning filling in soft/loose soil, including spreading, leveling, watering and well ramming in layers n.exc 25 cm complete all as specified. |
| 4 | Removing excavated material / soil exc 250 m but n. exc 500 m and depositing where as directed. |
| 5 | M&L for cement concrete type D-2 1:4:8 using 40 mm graded stone aggregate in filling foundation , sub base of floor and mass concrete complete all as specifed and directed. . |
| 6 | Material and labour for cement concrete type C2 1:3:6 (20mm graded stone aggregate) foundation filling of mass concrete fixing of angle iron posts ,coping etc complete all as specified and as directed |
| 7 | M&L Plain Cement Concrete Type B2 1:2:4(using 20 mm graded granite stone aggregate) in coping etc complete all as specified and directed. |
| 8 | Excavating post holes or similar holes, each not exceeding 0.50 Cu. M, getting out in Hard/ Dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 100m & making good surface complete all as specified and directed. |
| 9 | S&F Plates (plain or chequered ) channels , square cut or notched (ordinary and counter sunk) forming holes, without any attachement,conforming to Fe 410W Gde E-250 etc complete all as specified and directed. |
| 10 | S&F wind ties for roof including securing bolts including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 etc complete all as specified and directed. |
| 11 | Dismantling plain or corrugated steel sheeting, any gauge, and thickness including Nainital pattern and roof covering, complete all as specified. |
| 12 | S&F for Pre- Painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.60mm thick of any colour any profile as per required, having tensile strength of 550Mpa Coating Mass (GSM): AZ-150 (150 g/m²) Compliance Standards: ASTM A792, AS1397, IS 15961, or JIS G3321 as in roof covering/ cladding to wall, fixed with self tapping screws, at any height of the bld ,including all necessary scoffolding etc complete all as specified and as directed by Engineer-in-charge. |
| 13 | S&F for Pre- Painted galvatume aluminium zinc coating GI based plain steel sheet 0.60mm thick of any colour any profile as per required, having tensile strength of 550Mpa Coating Mass (GSM): AZ150 (150 g/m²) Compliance Standards: ASTM A792, AS1397, IS 15961, or JIS G3321 as in roof covering/ cladding to wall, fixed with self tapping screws, up to 10m height of the bld ,including all necessary scoffolding etc complete all as specified and as directed by Engineer-in-charge. |
| 14 | S&F tublar trusses (framed) , posts,purlins, rafter ,distance pieces, etc. including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS 1161-11979 Gde St -240 complete all as specified. |
| 15 | Dismantling structural steel work including doors, gates but excluding framed truss etc. |
| 16 | Dismantling of wrought iron or mild steel work of any description not other wise provided for complete all as specified. |
| 17 | S&F mild steel (framed) work as in ,posts, struts,purlins, crane gantries, rails (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.connecting plates of conforming to Fe 410-W Gde-E-250 Quality A complete all as specified. |
| 18 | S&F Mild steel screw bolts dia of neck 5 to 10mm (machine made) with hexagonal or squareheads at one end andscrewed the ther, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but not exc 10cm long long complete all as specified. |
| 19 | Demolition of concrete (un re-inforced) of any description and in any position not other wise specially provided for complete all as specified and as directed. |
| 20 | Demolition of brick work or stone boulder masonry,built in cement mortar or cement lime mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specifed and directed. |
| 21 | Material and labour for brick work with Sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in Cm (1:6) all as specified. |
| 22 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water etc. |
| 23 | Material and labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4, finished even and smooth without using extra cement, complete all as specified. |
| 24 | M&L for preparation of new external surface of walls, applying two coats of exterior grade weather resistant anti fungal paint , over a coat of primer complete all as specified and as directed. |
| 25 | M&L for complete removal of external surface of wall applying two coats of exterior grade weather resistant, antifungal acrylic paint over one coat of acrylic primer on walls, chajjas complete all as specified and as directed. |
| 26 | S&Fpoly vinyl chloride(PVC) coated coloured chain link fencing of mesh aparture 75mmx75mm diagonal shape and 4mm outer dia( Inner dia 2.40mm to 2.50mm GI+1.60mmPVC coating) and weight n.exc 4 kg per sqm , and mesh, made up, including link line wire, in fencing including straining and fixing to wood, concrete or steel posts and or to straining bolts, including securing with and provision of gavanised iron tying wire gavanised iron staples or steel pins etc all as directed by Engr-in-Charge. |
| 27 | M&L for Preparation of new steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of Epoxy (anticorrosive paint ) a coat epoxy primer including scrapping by mechanical abrasion using a power tool (like an angle grinder or rotary tool) fitted with a wire wheel/grinding mechin including all necessary scoffolding etc and up to 10m ht of the bldg complete all as specified and as directed by Engineer-in-charge. |
| 28 | Surface excavation n exc 30 Cm deep and averaging 15 Cm deep and getting out in hard dense soil complete all as specified. |
| 29 | M&L for hardcore of broken stone or boulders of gauge not exc. 63 mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 30 | M&L for 75 mm thick plain cement concrete 1:4:8 mix,type D2 (using 40 mm graded stone aggregates) as in subbase to floor complete all as specified and as directed. |
| 31 | M& L for sand cusion filling under floors including watering and consolidation complete all as specified and directed. |
| 32 | M& L for 80mm thick rubber moulded glossy finish concrete interlocking paver block any shape and size conforming to IS 15658-2006 ,M-40 grade laid over sand cushioning after consolidation set and level with grey cement and pigment , etc complete all as specified and as directed Note: sand cushion will be measured separetely. |
| 33 | M&L for chequered cement concrete with glossy finish tiles with grey cement and pigments 300mmx300mm x 22-25mm thick set and jointed in neat cement slurry in floors over and including 20mm screed bed in CM (1:6) complete all as specified and as directed. |
| 34 | M&L for provding plain cement concrete 1:2:4 type B-1 using 20mm graded aggregates as in coping, apex stones,bed blocks for fixing of angle iron posts and similar works etc including weathering, slightly rounded or chamfered angles and throating, including form work complete all as specified as directed . |
| 35 | Raking out joints/ pointing of cement or cement lime mortar to random rubble or poly gonal rubble uncoursed or brought up to courses complete all as specified |
| 36 | M&L for Raised pointing in CM 1:4 to random or polygonal rubble un coursed or up to course complete all as specified . |
| 37 | M&L for Preparation of old steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of Epoxy (anticorrosive paint) a coat epoxy primer including scrapping by mechanical abrasion using a power tool (like an angle grinder or rotary tool) fitted with a wire wheel/grinding mechin ,including all necessary scoffolding etc and up to 10m ht of the bldg complete all as specified and as directed by Engineer-in-charge. |
| 38 | M&L for preparation of old painted galvalume roof steel surface to wash thoroughly with an alkaline detergent or specialized metal cleaner to remove dirt, grease, and soluble zinc salts ,Scrub with a stiff nylon or non-metallic scouring pad and rinse with clean water until a water break-free surface is achieved (water spreads evenly without beading).Apply a specialized oil based zinc-phosphate primer or exterior acrylic metal primer, designed specifically for galvanized substrates and applying two coats of a high-performance exterior acrylic, polyurethane, or Epoxy-ester top coat compatible of approved shade/colour by Engineer-in-charge. Note: Use brush, roller, or airless spray according to product specifications, allowing adequate recoating intervals (usually 4 to 16 hours depending on ambient temperature and humidityand including all necessary scoffolding etc up to 10m ht of the bld complete all as specified and as directed by Engineer-in-charge. |
| 39 | Material and labour for complete removal of existing treatment of old decorated wall surface applying two coat of plastic emulsion paint over two coats of white cement based wall care putty smooth finish etc of approved make & shade up to 10m height of the bld ,including all necessary scoffolding etc and up to 10m ht of the bldg complete all as specified and as directed by Engineer-in-charge. |
| 40 | Complete removal of existing treatment of external wall surfaces including removing fungus ,algae dirt, oil, grease and loose particles by wire brush,cleaning, washing with water jet Machine,and applying with Dr fixit crack filler by proper grooving , and apply two coats of Dr fixit (one coat rain coat water proofing+one coat rain coat classic top coat) of approved shade by Engineer-in-charge over a coat of primer .The drying time of two coats will be 6 to 8 hrs ,including all necessary scoffolding etc and up to 10m ht of the bldg complete all as specified and as directed by Engineer-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender