Defence Statutory Bodies & Commissions/Committees Closing in 5 days TDR #57879075

Tender For Repair To Roof Treatment, Chajja/Mumty, Plastering And Connected Work In The Minor Units In The Aor Of Age B/R Iii At Chandimandir Mil Stn

Issued by Statutory Bodies & Commissions/Committees · Panchkula, Haryana
Tender Value
49 Lakhs
Estimated cost
Bid Submission
02 Nov 2026
5 days left
EMD
98000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Panchkula → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair To Roof Treatment, Chajja/Mumty, Plastering And Connected Work In The Minor Units In The Aor Of Age B/R Iii At Chandimandir Mil Stn

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 17-Oct-2026 Revised BoQ BOQ 26-Oct-2026
2 17-Oct-2026 Revised Page Other 26-Oct-2026
3 26-Oct-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-Nov-2026
4 17-Oct-2026 Revised BoQ BOQ 02-Nov-2026
5 17-Oct-2026 Revised Page Other 02-Nov-2026

BOQ

Name of Work:- REPAIR TO ROOF TREATMENT, CHAJJA/MUMTY, PLASTERING AND CONNECTED WORK IN THE MINOR UNITS IN THE AOR OF AGE B/R III AT CHANDIMANDIR MIL STN
Sl. No. Item Description
1Taking down cement or cement lime plaster on brick or stone walls etc including raking out joints, hacking for key scrubbing down with water etc complete.
2Repair to RCC sunshades, chajjas, balconies, columns, bands, beams and similar RCC work at any position / height by dismantling loose / disintegrated portion including necessary scafolding and safety arrangements and fixing of reinforcement (cut to length, bent to shape required, including cranking, bending spirally including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips)/ chicken wire mesh wherever required and dubbing out with cement concrete 1:1.5:3, 15mm to 50mm thick, using 6 to 12mm graded stone aggregate to make up and finished the required shape including provision of necessary scaffolding and formwork up to four storey bldg if required and finished with 5mm thick rendering in cement mortar 1:4 finished even and fair without using extra cement complete all as specified and directed. (NOTE : Supply only reinforcement and GI wire netting will be measured and paid separately under respective items)
3Cutting down small trees / bushes from wall/roof/chajja of building including digging out the roots from brick work or any other structure portion of building including applying root killer chemical as per manufacturer instructions and making good the disturbed portion to match the existing surface complete all as specified and directed
415mm thick plaster on fair faces of brick work or concrete surfaces, finished even and smooth in cement mortar 1:4 without using extra cement including water proofing compound and necessary scaffolding, safety arrangements of plaster upto and including 4 Storey Bldg complete all as specified & directed. Note: - WPC shall be measured and paid separately.
515mm thick plaster rendering in Cement and Sand mortar 1:6 on fair faces of brick wall or on concrete surfaces finished even and smooth without using extra cement and providing necessary scaffolding , safety precautions and other requisite arrangements all as per site requirement complete all as specified & directed.
6Supply only liquid water proofing compound (ISI Marked) complete all as specified & directed.
710mm thick rendering in Cement and Sand mortar 1:3 on concrete surfaces up to 15 Metre height as in chajja/mumty at any position including necessary scafolding work, finished even and fair smooth without using extra cement, complete all as specified and directed.
85mm thick rendering in Cement and Sand mortar 1:3 concrete surfaces as in ceiling finished even and smooth without using extra cement complete all as specified and directed
9preparation of new plastered surface and apply three coats of white wash on ceiling surfaces complete all as specified and directed
10Dismantling of brickwork or stone/boulder masonry built in lime mortar including all quoins, aches, pillars, etc, but excliding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
11Brick work with sub class ‘B’ bricks of old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed.
12All as per serial item No 11 herein before but except bricks (using old serviceable bricks obtained from here-in-above) complete all as specified and directed.
13Preparation of new surfaces of any description of wall, facia, ceiling, RCC etc and applying two coats of oil bound destemper over one coat of interior wall primer including wall care putty (average thickness 1.5 to 2.5mm as required for desired smoothness and leveling of surfaces in two or more layers) and sand papering for making the surfaces even and smooth complete all as specified and directed.
14Applying three coats of white wash on new plastered surfaces including preparation of new surfaces complete all as specified and directed
15Preparation of new plastered surfaces of walls and applying two coats of cement base paint (any colour) including all necessary scaffolding and safety arrangements, complete all as specified and directed.
16Preparation of old surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces, complete all as specified and directed.
17Applying one coat of cement base paint (approved collour) including preparationof old surface of wall and walls and cenessary scaffolding, safety arrangments upto 04 storey hight, complete all as specified and directed.
18Applying one coat of oil bound distamper including preparationof old surface of wall and necessary scaffolding, safety arrangments upto 04 storey hight, complete all as specified and directed.
19One coat of white wash on old wall surfaces including preparation of surfaces, complete all as specified and directed.
20One coat of white washing on old ceiling surfaces including preparation of surfaces, complete all as specified and directed.
21Preparation of old decorated ceiling surfaces and applying one coat of oil bound distemper complete all as specified and directed.
22Preparation of old wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
23Applying one coat of synthetic enamel paint on steel and iron surfaces over 10 cm width or girth including preparation of old surfaces complete all as specified & directed.
24Applyin one coat of synthetic enamel paint of any shade /colour over old painted /unpainted stone/concrete /paver tiles/chequered tiles/kerb stones surfaces of any description not otherwise described over 10cm width or girth including preparation of old surfaces, complete all as specified and directed.
25Hollow PVC wall lining, with necessary screws and drilling, PVC panel 0.5mm thick each flap and both flap connected with ribs and overall thickness not less than 5mm design printed in 300 to 450mm wide pannels, fixed as in repair complete all as specified and as directed
26PVC sheet fillet 35mm wide, 5mm thick for wall paneling inclusive of fixing in to wall to make PVC frame as per specification and drawing ,fixed as in repair complete all as specified.
27Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviveable tiles to store and rubbish off the premises complete all as specified and directed
28Glazed ceramic coloured tiles in vertical surfaces of size 300 x 450 x 7mm set and jointed in neat cement slurry over and including 10mm thick rendering in CM 1:4 for receiving the tiles complete all as specified.
29Non skid, first quality ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area or each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
30Coloured vitrified ceramic tiles 8-10mm thick (square / rectangular) polished, area of each tiles exc 0.18 sqm but n.exc 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over a 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed
31All as per serial item No 30 herein before but in skirting including ncessary cutting as directed etc over and including 10mm thick rendering in cement mortar 1:4, complete all as specified.
32Vitrified ceramic tiles 10mm thick (square / rectangular) polished, light shade, area of each tiles exc 0.42 sqm but n.exc 1.00 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed
33All as per serial item No 32 herein before but in skirting including ncessary cutting as directed etc over and including 10mm thick rendering in cement mortar 1:4, complete all as specified.
34Demolition of stone slabs and tiles of any description or tickness in floors, aprons laid, bedded and pointed in any mortar complete all as specified and directed
35Coloured non skid porcelain tiles exterior grade 300x300x9-10mm thick heavy duty (Endura from Johnson or equivalent) as in floor, set and jointed in neat slurry and pointed in coloured cement to match the colour of tiles over and including screed bed or bedding layer of 15mm thick in cement mortar 1:6, complete all as specified and directed
36Kota Stone Slab flooring, minimum size 550 x 550mm, 18 to 20mm thick, best quality over and including cement screed bed 20mm thick in cement mortar 1:4, laid and jointed with grey cement slurry and pointed with grey cement mixed with pigment to match the shade of the slab, inclduing rubbing and mirror polishing complete all as specified and directed.
37Granite stone slabs, 16 to 18mm thick, width and length as per site requirement, best quality machine cut and polished to be fixed in floors,cooking platform, tread, riser of steps and vertical surfaces etc and jointed with gray cement slurry and pointed in white cement mixed with marble dust (1:2) with admixture of pigment to match the shade of slab, rubbing, cutting / rounding of outer edges and corners where directed with and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
38Factory made rubber moulded machine pressed coloured chequered cement concrete tiles 250mm x 250mm x 22-25mm thick (with grey cement and pigments), set, jointed and pointed in neat cement slurry with grey cement with pigment to match the colour of tiles, glossy finish, laid over and including 20mm thick screed bed in cement mortar 1:4, complete all as specified and directed.
39Concrete interlocking paver block, with grey cement and no pigment, glossy finish design as approved, any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade, and including laid over 25mm thick sand cushioning free from debris, vegetation etc complete all as specified and directed
40Demolition of mud phuska as in roof of any thickness incl plastering and leeping etc (whether full thickness removed or only a part thereof) complete all as specified & directed.
41Dismantling of existing brick tiles or terracing tiles single layer on roof grouted in cement mortar, demolition of mud phuska of any thickness including removal of rubbish from site complete all as specified & directed.
42PCC 1:3:6 type C-2 (20 mm graded stone aggs) as in roof padding, roof kerbs rounded or chamfered on edges, complete all as specified and directed.
4320mm thick rendering in Cement and Sand mortar 1:4 over roof slab and sunken portion finished even and fair mixed with water proofing compound, including dimantling of the existing roof slab / suken portion complete all as specified. (NOTE : WPC will be measrued and paid separately)
44Supply only Liquid water proofing compound (ISI Marked) complete all as specified & directed.
453mm thick Atactic polypropylene polymer (APP) based polymeric membrane minimum weighing 3kg/sqm and reinforced with polyester non woven fabric (weight not less than 150 gms/sqm) laid over a coat of oil bound bitumen primer @0.40L/Sqm by same membrane manufacturer of density 0.87 to 0.89 kg/L at 25° C temperature and viscosity 70 to 160 CPS. The membrane shall be laid using butane torch and sealing all joints etc having 75mm side lap joint and 100m end lap joint after preparing the surface as per standard practice and as per manufacturer instructions and finished complete all as specified & directed.
46PCC tiles 200x200x25mm thick with including 20mm thick cement mortar 1:4 jointed grouted and pointed complete mixed with crude oil 5% by weight of cement complete all as specified and directed.
47Demolition of plain cement concrete (unreinforced) of any description and in any position complete all as specified and directed.
48100mm thick plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in sub base complete all as specified & directed.
4915 mm dia medium grade GI tubing with all fittings to walls and ceilings or laid under floors, including taking down old tubing complete all as specified and directed.
5020 mm dia medium grade GI tubing with all fittings to walls and ceilings or laid under floors, including taking down old tubing complete all as specified and directed.
5125 mm dia medium grade GI tubing with all fittings to walls and ceilings or laid under floors, including taking down old tubing pipe complete all as specified and directed.
52Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar (1:3) for concealed pipe etc and making good, cutting not exceeding 10cm girth complete all as specified & directed by Engineer-in-charge.
53500 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) triple layered, screwable lid, hoisted and fixed in position, including tank nipple, float valve, ball valve 20mm PTMT, including dismantling of existing water tanks and removing from site all as specified in SSR Part-I and all as directed by Engineer-in-charge.
541000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) triple layered, screwable lid, hoisted and fixed in position, including tank nipple, float valve, ball valve 20mm PTMT, including dismantling of existing water tanks and removing from site all as specified in SSR Part-I and all as directed by Engineer-in-charge.
55Vitreous china squatting pan \\"orissa\\" pattern, size 580 x 440 mm white, with integral foot rest including 'P' or 'S' trap (excluding flushing cistern and flush pipe) and making good to the floor fixed as in repair complete all as specified & directed by Engineer-in-charge.
56PVC valve less syphonic action type flushing cistern low level white with PVC in let ball valve, float and handle, 10 ltrs capacity and connection to pipes, set with concrete and making good to floor, fixed in repair complete all as specified & directed.
57Vitreous China Wash down water closet pan (pedestal pattern), white (excluding, fixing bolts, flushing cistern and flush pipe) including connection to trap complete set with cement fixed as in repair complete all as specified and directed.
58Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, fixed as in repair complete all as specified and directed.
59Vitreous china wash hand basin, white, flat back size 550 x 400 mm, excluding taps, waste chain, plug and porcelain stopper but including brackets, cutting for and pinning in ends of bracket or erecting stand, fixed as in repair complete all as specified and directed.
60Vitreous China half stall urinal, fixed against wall in cement mortar (1:2), securing urinal with and including 60mm long brass screws, pointing around urinal back in cement, including CP waste coupling, 32mm PVC waste pipe, fixed in repairs,complete all as specified and directed.
61PVC (SWR) rain water pipe, 110mm bore of pressure rating 6kg/cm2 single socketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mm including nuts bolts etc, fixed as in repair complete all as specified and directed.
62110 mm bore PVC (SWR) bends of any radius with access door, complete all as specified and directed.
63PVC (SWR) pipe 75mm bore of pressure rating 6kg/cm2 single socketed in any length with rubber ring joints, laid in trenches or in flors, fixed as in repircomplete all as specified and directed.
6475 mm bore PVC (SWR) bends of any radius with access door, complete all as specified and directed.
65PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75mm bore complete all as specified.
66Door closer (aluminium extruded section) hydraulically regulated designation No 3, universal type, suitable for door shutters of 701mm to 850mm in width and of weight between 36 to 60 Kg, fixed as in repair complete all as specified and directed.
67Door closer (Brass chromium plate) hydraulically regulated designation No 3, universal type, suitable for door shutters of 701mm to 850mm in width and of weight between 36 to 60 Kg, fixed as in repair complete all as specified and directed.
68Double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty fixed as in repairs, complete all as specified and directed.
69Floor door stopper of aluminum alloy body and tongue, anodized with hard drawn steel spring, fixed in floor (140mm size), complete all as specified and directed.
70D' type 200mm powder coated aluminium powder coated handles for aluminium doors complete all as specified and directed.
71Butt hinges 100mm size, of extruded aluminum alloy with galvanised mild steel hinge pin, anodised, type C-21, complete all as specified and directed.
72Bib taps brass, with wall flange, chromium plated, cast copper alloy, screwed down for iron pipe or for brass ferrule, suitable for 15mm bore pipe, fixed in repair complete all as specified and directed.
7315mm bore pillar tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe, fixed as in repair, complete all as specified and directed.
74Brass CP mixer for mixing hot and cold water screwed down for iron pipe and fixed with 450mm long copper pipes incl all cecessary fitting suitable for 15mm bore pipe, fixed as in repair complete all as specified and directed.
75200mm aluminum anodized barrel tower bolts of extruded section, complete all as specified.
76150mm aluminum anodized barrel tower bolts of extruded section, complete all as specified.
77Aluminium handles, cast type anodized of size 150 mm, ISI marked, complete all as specified.
78Harrison rails mild steel chromium plated of 25mm dia fancy type, with fixing brackets, stops, rollers etc in aproved design and colour, fixed as in repair complete all as specified.
79Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tack or galvanised wire staples, fixed as in repair complete all as specified and directed.
80Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions, complete all as specified and directed.
81Brass chromium plated, tubular towel rail 20 mm dia. ‘D’ type, 60 cm long between flanges including brackets, fixed as in repair complete all as specified and directed.
82Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, complete all as specified and directed.
83Chromium plated, fancy type shower rose with swivel joints 125mm dia with arm and fixing to steel pipe 15mm bore, complete all as specified and directed
8412mm thick toughned glass glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes with necessary screws/ beading, rubber packing, L Patch bottom and top, self closing patch etc complete all as specified and directed.
85Heavy duty stainless steel door handle 300mm long for toughned glass door pull/ push handle chrome finish complete all as specified and directed.
86Taking down chowkhats or frame n.exc 1.5 Sqm with shutter (without taking off shutters from the frame) and removal from site complete all as specified & directed.
87Taking down chowkats or frame exc. 1.5 Sqm and n exc 4 Square metre with shutters, without taking off shutters from the frame, complete all as specified and directed.
88Taking down shutter of any description exc 1 Sqm but n.exc 2 Sqm complete all as specified and directed.
89Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification complete all as specified and directed.
902nd class hardwood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified & directed.
91Factory made solid PVC moulded door shutter, with wood free EPS core 28 to 30mm thick (stiles), with 2, 4 or 6 raised panel design with 2mm thick moulded PVC sheet on the front face and 2mm plain colour PVC sheet on back face, supplying and fixing in frame at site complete all as specified and directed.
9230 mm thick flush shutters, teak wood face, designer pattern with decorative choice lamination on both side of the door fixed with adhesive, solid core construction, with block board core, commercial type on both sides all as specified and directed by Engineer-in-charge.
9330mm thick (batten thickness) second class hard wood, glazed and gauged Skeleton shutter, open rebated and prepared to receive glass, gauge etc (without sash bars), divided into squares, with plain chamfered or rounded, mitred and rebated sash bars, edges of farming plain, chamfered or rounded with cut mitred beads for securing glass etc, supplied and fitted to chowkhats complete all as specified & directed. (Note:- The dimension of the various components or part of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I)
94Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) With Semi preforated 12mm thick micro rectangular edged GRG false ceiling tiles, false ceiling tiles of size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2% humidity resistance of 99% NRCO .05 to 0.75 as per IS 8225:1987, Non-combustible as per BS 476 (part4)- 1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides ) comprising of main- T runners of size 15 x32 mm of length 3000mm, cross-T of size 15 x 32 mm of length 1200mm and secondary intermediate Cross-T of size 15 x 32mm of length 600mm to form grid module of size 600 x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diaMetre M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm, complete all as specified and directed.
95Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets/ACP etc of any thickness, including cover fillets complete all as specified & directed by Engineer-in-charge.
96Factory made steel window box type with side hung shutters including box type hinges and one shop coat of red oxide primer, 125mm steel handle-02 Nos mild steel ISI marked tower bolt 125mm size (minimum 2 for each shutter) complete with glazing bars, dovetailed or welded fixed with and including MS flat of suitable size for fixing grills and guards bars etc as in repairs, complete all as specified.
97Factory made steel window box type with side hung shutters including box type hinges and one shop coat of red oxide primer, 125mm steel handle-02 Nos mild steel ISI marked tower bolt 125mm size (minimum 2 for each shutter) complete without glazing bars, dovetailed or welded fixed as in repairs, complete all as specified.
98Factory made fixed type steel Ventilator with glazing bar including dismantling & removal from site complete all as specified and directed.
99Framed work such as grill guard bars etc welded to steel frame MS round/square bar conforming to Fe 290 Gde-E 165 complete all as specified and directed.
100Hacking out old broken glass (any thickness, size, quality or description) from wooden, metal frames including punching or drilling out glazing pins/spring clips etc complete all as specified and directed.
1014mm thick sheet glass ordinary quality any size and in any type of frame and glazing with oil putty (or beading) in square n.exc 0.5 Sqm in each panes complete all as specified and directed.
102Preparation of new steel surfaces and applying two coats of synthetic enamel paint of any tint complete all as specified and directed.
103Preparation of old steel surfaces and applying two coats of synthetic enamel paint of any tint complete all as specified and directed.
104Demolition of reinforced cement (reinforcement cut as required facilitate demolition) concrete in roofs, floors, beams, staircases, landing, chajjas and similar suspended work including separating of steel from RCC, complete all as specified and directed.
105Plain cement concrete 1:3:6 type B-1 using 20mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified & directed.
106Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified.
1073mm thick aluminium composite panel sheet (ACP) of wall , parapets and ceiling including necessary frame work of iron / steel for ACP sheet, scaffoldig upto 4 storey building on paraet/ Projetion/ chajjas, colour as approved by Engr-in-Charge, fixed as in repair all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57879075
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 49 Lakhs
LAST DATE 02-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair To Roof Treatment, Chajja/Mumty, Plastering And Connected Work In The Minor Units In The Aor Of Age B/R Iii At Chandimandir Mil Stn
Basic Detail
Tender No GE/CHM-94/2026-2027
Bidding Type Tender
Location
City Panchkula
State Haryana
Key Dates
Publish Date 26 Oct 2026
Submission Date 02 Nov 2026
Open Date 04 Nov 2026
Finance
Tender Value 49 Lakhs
Tender Fee 500
EMD 98000
Exemption Available
Document List
67fc0445-0d46-47d9-bf03-67058911110d.html
BOQ_888537.xls
Tendernotice_1.pdf
Tenderpages94.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 26, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 26, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 26, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 02, 2026
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 5 days
Nov 02, 2026
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 5 days
Nov 02, 2026
18:00 IST

Corrigendum-5 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 5 days
Nov 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Nov 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

67fc0445-0d46-47d9-bf03-67058911110d.html

xls

BOQ_888537.xls

pdf

Tendernotice_1.pdf

pdf

Tenderpages94.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender