Tender For Repair And Maintenance Of Ht Lines, Ug Cables, Transformer And Allied Works Of Various Units At Kargil , Kaksar, Hinskut, Budkharbu, Apati, Chanigund And Hardas Under Ge Kargil
Tender Overview
Project Description
Tender for Repair And Maintenance Of Ht Lines, Ug Cables, Transformer And Allied Works Of Various Units At Kargil , Kaksar, Hinskut, Budkharbu, Apati, Chanigund And Hardas Under Ge Kargil
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 14-Oct-2026 | BOQ | BOQ | 26-Oct-2026 |
| 2 | 26-Oct-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 02-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | S&F in replacement of lightening arrester for outdoor use, non liner resister type, horn gap and choking coil, maximum working pressure 11000 Volts, discharge capacity 65 kilo amp complete all as specified and directed by the Engr-in-Charge. |
| 2 | Straining and re-stretching of existing over head aluminium conductor steel reinforced (ACSR) of any size on HT poles with mechanical tool ,including binding and jointing the conductor with and including 14 SWG binding wire and jumpers connections with PG clamps complete all as specified and directed by Engr-in-Charge. |
| 3 | Straining and re-stretching of existing over head aluminium conductor steel reinforced (ACSR) of any size on LT poles with mechanical tool, including binding and jointing the conductor with and including 14 SWG binding wire and jumpers connections with PG clamps complete all as specified and directed by Engr-in-Charge. |
| 4 | Dismantling of ACSR conductor any type any size. |
| 5 | S&F in ACSR conductor of (weasel) 6/1/2.59 for HT line (11 KV), straching properly on insulators and binding with aluminium binding wires, jumpers including fixing on insulators on each poles in span and tightening with permissible sag in between span etc complete all as specified and as directed by Engineer-in-charge. |
| 6 | S&F ACSR conductor or service feeder distribution span of (Rabbit) 6/1/3.35 for LT line (440 Volts), straching properly on insulators and binding with aluminium binding wires, jumpers including fixing on insulators on each poles in span and tightening with permissible sag in between span etc complete all as specified and as directed by Engineer-in-charge. |
| 7 | Dismantling cross-arms of M.S. channel or angle sections etc. complete all as specified and directed. |
| 8 | M& L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint,complete all as specified and directed by Engr-in-Charge. |
| 9 | Supply and fix as in repairs ON LOAD change over switch with sheet metal enclosure 415V , 4 pole of capacity 100 Amps including connecting up incoming/ outgoing cables with suitable lugs and testing complete all as specified and directed by the Engr-in-Charge. |
| 10 | Supply and fix as in repairs ON LOAD change over switch with sheet metal enclosure 415V , 4 pole of capacity 200 Amps including connecting up incoming/ outgoing cables with suitable lugs and testing complete all as specified and directed by the Engr-in-Charge. |
| 11 | Supply and fix as in repairs ON LOAD change over switch with sheet metal enclosure 415V , 4 pole of capacity 320 Amps including connecting up incoming/ outgoing cables with suitable lugs and testing complete all as specified and directed by the Engr-in-Charge. |
| 12 | Supply and fix MCCB 250 Amps, 415 volts,Thermal Magnetic released based 4 pole 415 Volts, 36 KA breaking capacity complete all as specified and directed by the Engr-in-Charge. |
| 13 | Supply and fix MCCB 200 Amps, 415 volts,Thermal Magnetic released based 4 pole 415 Volts, 36 KA breaking capacity complete all as specified and directed by the Engr-in-Charge. |
| 14 | Supply and fix MCCB 160 Amps, 415 volts,Thermal Magnetic released based 4 pole 415 Volts, 36 KA breaking capacity complete all as specified and directed by the Engr-in-Charge. |
| 15 | Supply and fix MCCB 125 Amps, 415 volts,Thermal Magnetic released based 4 pole 415 Volts, 25 KA breaking capacity complete all as specified and directed by the Engr-in-Charge. |
| 16 | Supply and fix MCCB 100 Amps, 415 volts,Thermal Magnetic released based 4 pole 415 Volts, 16 KA breaking capacity complete all as specified and directed by the Engr-in-Charge. |
| 17 | Dismantling and taking out the old stay assembly complete incl demolition of plain cement concrete all as specified and directed by the Engr-in-Charge. Note : (i) Unit rate of this item includes the loose/disconnect the all accessories which are connected to stay assy includng necessary excavation as directed. |
| 18 | S&F Stay assembly complete with GI stay rod 20 mm dia 1800 mm long, MS plate 230x2306 mm, stay bow, loop insulator, PCC 1:3:6, connecting bracket of suitable MS flat and nut bolt washers etc complete all as specified in electrical plate No 1 of SSR Part-1 all as directed by Engineer-in-Charge. |
| 19 | Dismantling of air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for replacement repair/ replacement of broken/worn out components and insulators etc. or carrying to MES store. |
| 20 | S&F Switch air break gang operated triple pole mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current rating upto 400 Amps 11000 volts all as specified and directed by the Engr-in-Charge. |
| 21 | S & F in replacement LT bush assembly brass complete with double check nuts, washers and oil seal including all accessories with bushing insulators for transformer capacity 63/100 KVA complete. |
| 22 | S & F in replacement LT bush assembly brass complete with double check nuts, washers and oil seal including all accessories with bushing insulators for transformer capacity 160/200 KVA complete. |
| 23 | S & F in replacement LT bush assembly brass complete with double check nuts, washers and oil seal including all accessories with bushing insulators for transformer capacity 500 KVA complete . |
| 24 | S & F in replacement HT bush assembly brass complete with double check nuts, washers and oil seal including all accessories with bushing insulators for transformer capacity 63/100 KVA complete. |
| 25 | S & F in replacement HT bush assembly brass complete with double check nuts, washers and oil seal including all accessories with bushing insulators for transformer capacity 160/200 KVA complete. Please Enable Macros to View BoQ information |
| 26 | S & F in replacement HT bush assembly brass complete with double check nuts, washers and oil seal including all accessories with bushing insulators for transformer capacity 160/200 KVA complete. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender