Defence Statutory Bodies & Commissions/Committees Closing in 9 days TDR #57879027

Tender For Provn Of Temp Controlled Enivormental Condn For Sps Rooms And Flame Proof Ac Petroleum, Oils & Lubs Rooms At Certain Unit At Army Area Banar

Issued by Statutory Bodies & Commissions/Committees · Jodhpur, Rajasthan
Tender Value
32 Lakhs
Estimated cost
Bid Submission
26 Oct 2026
9 days left
EMD
64000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jodhpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Temp Controlled Enivormental Condn For Sps Rooms And Flame Proof Ac Petroleum, Oils & Lubs Rooms At Certain Unit At Army Area Banar

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 15-Oct-2026 CorrigendumNo.01 BOQ 26-Oct-2026

BOQ

Name of Work:- PROVN OF TEMP CONTROLLED ENIVORMENTAL CONDN FOR SPS ROOMS AND FLAME PROOF AC PETROLEUM, OILS & LUBS ROOMS AT CERTAIN UNIT AT ARMY AREA BANAR
Sl. No. Item Description
1Supply, installation, testing and commissioning of Flameproof / Weatherproof Split Type Air Conditioner, 1.5 Ton capacity, suitable for hazardous area application, complete with hermetically sealed compressor of Emerson make or equivalent, operating on 230 Volts, Single Phase, 50 Hz AC supply, using refrigerant gas as required.The complete AC unit shall be duly certified by CIMFR, PESO and BIS (certification for complete unit and not for individual components), Indoor and outdoor casing made of MS fabricated weatherproof / flameproof enclosure, cooling coil of aluminium, complete with all standard accessories including 5 metre copper tubing pair, 5 metre interconnecting cable and Flame proof AC Box mounting arrangements, testing, commissioning and handing over in satisfactory working condition. complete all as specified and directed by Engr-in-charge.
2Supply install and testing hi wall mounted inverter technology split type air conditioning units indoor/outdoor complete with cordless remote remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 1.5 TR and copper tubing with insulation upto 5 metres ,including provision of drain pipe upto 3 mtr, plug top 15 Amps and 3 core PVC insulated copper cable of size 2.5 Sqmm multi stranded upto 5 metre complete all as specified and directed by Engr-in-charge.
3S & F sheet metal enclosure with single pole & neutral enclosure with 2 pin and earth plug and socket complete with one single pole MCB 240 volt, 20Amp complete all as specified and directed by Engr-in-charge.
4S & F Flameproof Distribution box VTPN 4 way Double door with 150 Amps rated Busbar including MCCB TPN 100A 18 KA 'C\\" Curve - 01 Nos & MCB SP 32 A 10 KA 'C\\" Curve- 08 Nos, including necessary incoming and outgoing connection with suitable size of copper lug etc complete all as specified and directed by Engr-in-charge.
5Material and labour for sub main wiring with two single core FRLS PVC insulated unsheathed copper stranded conductor of size 4.0 Sqmm and one run of size 4.0 Sqmm for continious earthing connected to common earth dolly complete drawing in and including suitable size of In Steel conduit with all fittings like tie,bend ,end cap,GI flexible etc and accessories fixed with GI clamp (clamp to clamp distance not exceed 1.2 mtr) clamp properly fixing on wal/ ceiling /trusses/beam complete all as specified and directed by Engr-in-charge. Note:- Three runs of FRLS conductor 4.0 sqmm along with Steel conduit will be measured as one unit
6Material and labour for XLPE cable incl Laying and testing in trenches or fixing or passing through pipe 1100 volts grade heavy duty Insulated multi stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and over PVC sheathed incl taking out old unservicable cable of 25 sqmm 4 core sizes. complete all as specified and directed by Engr-in-charge. Note:- Excavation , cable cover, sand and earth work, Pipe will be paid saperately.
7Material and labour for XLPE cable incl Laying and testing in trenches or fixing or passing through pipe 1100 volts grade heavy duty Insulated multi stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and over PVC sheathed incl taking out old unservicable cable of 70 sqmm 3.5 core sizes. complete all as specified and directed by Engr-in-charge. Note:- Excavation , cable cover, sand and earth work, Pipe will be paid saperately.
8Excavation in trenches / post holes in hard/dense soil not exceeding 1.5 mtr wide and not exceeding 1.5 meter in depth for taking out and laying pipe lines not exceeding 10 Sqm on plan and getting out, excavated earth, forming bottom surfaces to required level complete all as specified and directed by Engr-in-Charge.
9Returning, filling in, including spreading, watering and well ramming in layers not exc 25cm in soft/loose soil. complete all as specified and directed by Engr-in-charge.
10Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting point. complete all as specified and directed by Engr-in-charge.
11Supply and spreading /bedding sand cushoning for cable protection /cover in trenches 08 cm before laying of cable and 15 cm deep over the cable complete all as specified and directed by Engr-in-charge. Note :- Only punned thickness will be measured for payment purpose.
12Supply and laying un reinforced precast concrete cable cove class LV type 1 flat size 250 mmx 150mmx40mm complete all as specified and directed by Engr-in-charge.
13Material and labour for 50 mm dia galvanized iron tubing light grade for cable protection pole ,plinth protection, road crossing, trenches, footpath etc, complete all as specified and directed by Engr-in-charge. including clamps, nut bolt and washers.
14Supply and fixing MCB SP 20 Amps 230 Volt 10K A'C' curve complete all as specified and directed by Engr-in-charge.
15Supply and installation, testing and commissioning LT feeder pillar box suitable for 415 Volts 3 Phase 4 Wire, 50 Hz AC Supply System confirming to IS: 8623/93, outdoor type floor mounting along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm thick having Aluminium bus bar of rating 200 A, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The feeder pillar box shall be front and rear opening and having inner & outer shells. All the covers shall be provided with suitable locking arrangements, mounted on angle iron stand fixed at 75 cm height from the ground level made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6, and comprising of the following controls gears complete all as specified and directed by Engr-in-charge. (Note: i) The size of Feeder pillar box should not be less than 1000x1000x400mm, (ii) Drawing of LT Panel shall be submitted by manufacturer will be approved by Engr in charge before placing order. INCOMING:- MCCB 4P 125 Amp 25 KA thermal adjustable type , OUTGOING :- MCCB 100 A 4 pole 25 KA -01 Nos , MCCB 4P 63 Amp 16 KA thermal adjustable type -02 Nos, MCB SPN 32 A-02 Nos, Digital type volt meter & Amp Meter, LED type Indicating Lamp (03 Nos)
16Supply and fixing the LT Cable route indicator made by Jodhpur stone well finished and marking of letter \\"DANGER LT Cable MES\\", size 100mmx100mm, 75cm long, 15cm grouted with 1:3:6 PCC foundation below the ground level and 60cm of marker will be elevated on ground. letters of \\"DANGER LT Cable MES\\" will be painted with post office red colour and with black colour background complete all as specified and directed by Engr-in-charge.
17M&L for earthing complete with galvanised steel earth plate electrode 600 x 600x 6mm burried directly in ground (earth Each pit not less than 2.25 mrt deep below ground level) with top edged of the plate not less than 1.5 mtr below normal ground level, connected to galavanised iron earth lead by means of bolt, nut, check nut and washer of galavanised iron wire 4 mm dia as earthing lead as shown ni Electrical Plate No 3 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in earth pit in PCC 1:3:6 type C1 using 20mm stone aggreate, funnel, 20 mm dia GI medium grade water pipe, 15mm dia Gl light grade earth lead proteclion pipe, to the extent of 7.5m as earthing lead by means of Cl frame and cover, wire, copper lugs, wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15 cm including excavation of hard /dense soil and earth work pit cover Including disposal of surplus soil at a distance not exceeding 50m, complete testing on completion all complete as shown in electrical plate No 3 of SSR Part | 2009 complete all as specified and directed by Engr-in-charge.
18M & L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below normal ground level, connected to galavanised iron earth lead by means of bolt, nut, check nut and washer of galavanised iron strip 32x6mm as earthing lead as shown in Electrical Plate No 3 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in earth pit in PCC 1:3:6 type C1 using 20mm stone aggreate, funnel, 20mm dia GI medium grade water pipe, 40 mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs, wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15 cm including excavation of hard /dense soil and earth work pit cover including disposal of surplus soil to a distance not excessding 50m, complete testing on completion all complete as shown in electrical plate No 3 of SSR Part I 2009 complete all as specified and directed by Engr-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57879027
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 32 Lakhs
LAST DATE 26-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Temp Controlled Enivormental Condn For Sps Rooms And Flame Proof Ac Petroleum, Oils & Lubs Rooms At Certain Unit At Army Area Banar
Basic Detail
Tender No CWE (A) JODH/BNR- OF 2026-27(82627/67/E8)
Bidding Type Tender
Location
City Jodhpur
State Rajasthan
Key Dates
Publish Date 15 Oct 2026
Submission Date 26 Oct 2026
Open Date 01 Jan 0001
Finance
Tender Value 32 Lakhs
Tender Fee 500
EMD 64000
Exemption Available
Document List
35bba6cc-b3b5-4641-95e5-5ff0197b26c1.html
BOQ_888482.xls
TENDER67.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 26, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 9 days
Oct 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

35bba6cc-b3b5-4641-95e5-5ff0197b26c1.html

xls

BOQ_888482.xls

pdf

TENDER67.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender