Tender For Addition Alteration Of Roof Treatment At Bldg No E-9, E-21, P-32, P-41, P-51, P-52, P-64 & T 12A Under Ge (East) Ferozepur Cantt
Tender Value
39.13 Lakhs
Estimated cost
Bid Submission
26 Oct 2026
19 days left
EMD
78260
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Firozepur → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Addition Alteration Of Roof Treatment At Bldg No E-9, E-21, P-32, P-41, P-51, P-52, P-64 & T 12A Under Ge (East) Ferozepur Cantt
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of brick tiles single layer laid on roof jointed & pointed in cement mortar complete all as specified & directed. |
| 2 | Demolition/taking out mud from the roofs, any thickness, including plastering and leaping etc including removing rubbish upto 500 mtr from the site complete all as specified & directed. |
| 3 | Taking down of roof plasterr inciuding APP membrane on roof surface jointed & pointed in cement mortar complete all as specified & directed.. |
| 4 | M&L for rendering 10 mm thick in CM (1:4) mixed with integral water proofing compound as per mfg instr over the padding concrete while still the concrete is still green, complete all as specified & directed (For roof treatment)Note:- WPC will be measured & paid seperately. |
| 5 | M&L for water proofing treatment to roof surface including parapet wall comprising with the following course of treatment/ specifications form bottom to top:-(a) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg per sqm over a coat of bitumen primer @ 0.30 ltr per sqm including preparation of roof surfaces complete all as specified and as directed. (b) One layer of APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by torced application complete all as specified. Polymeric membrane shall be taken to a height of 60 cm (minimum) and then inserted inside the groove of parapet walls and shall be finished by a membrane flashing.Note: (i) Laying of APP based membranes shall be done by torch on method or as per manufacturer's instructions.(ii) A minimum overlap shall be 75mm length wise and 100 mm width wise of polymeric membranes respectively and sealed all overlaps and joints as manufacturer's instructions. (iii) The whole works shall be executed by the authorised company applicator. |
| 6 | M&L for two coat of aluminium paint over APP membrane complete all as specified & directed. |
| 7 | M & L for Cement concrete tiles 25cm x 25cm x 22mm thick, machine pressed; set and jointed in neat cement slurry over 15 mm thick screed in cement mortar (1:4) and pointed in neat cement mixed with pigment to match the shade of tiles,complete all as specified & directed. |
| 8 | M&L for Cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in roof padding complete all as specified & directed. |
| 9 | Demolition of brick work or stone/ boulder masonary built in cement mortor including all quoins, arches, pillars etc complete all as specifid & directed. |
| 10 | M&L brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius built in c:m 1:6 all complete all as specified & directed. |
| 11 | All as per srl item No 10 here-in-before but using old bricks retrieved from dismantling under ser item 09 here-in-before including cleaning and removal of mortar from old bricks etc complete all as specifid & directed. |
| 12 | Taking down cement plaster on brick walls of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as specified & directed. |
| 13 | M&L for Rendering 15mm thick in cement mortar (1:4) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified & directed. |
| 14 | M&L for applying new surface two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm the surface even and smooth complete all as specified and directed at height upto 12 mtr incuding necessary scaffolding over new surfaces. |
| 15 | Material and labour for applying bond coat of epoxy bonding agent & cement mortor in 1:1 ratio for bonding old and new concrete on damaged surfaces applying ready mix polymer modified mortar upto 60mm thickness (Chajjas fins, border,slab, beams etc) :-(i) Including application of rust remover on exposed reinforcement and subsequent application of anticorrosive coating. Also, pressure grouting with epoxy injection after application of polymer modified mortar.(ii) Use of electrical mixer to get the homogeneous dough on bond coat surfaces. (iii) To achieve required thickness repeat this step after 24 hrs as required.(iv) Keep the surfaces moist using water forg for 5 to 7 days etc complete all as specified and as directed.(v) Rate shall be inclusive of all necessary scaffolding for building height up to 24 meters complete all as directed by Engineer-in-Charge.Make of Chemicals : - Epoxy bonding agent, Rust remover, Anti corrosive coating, Polymer modified mortar, Epoxy grout shall be of Berger, Krishna, Dr Fixit, MC Bauchemie and M/s Cemistik, Sika or Equivalent as approved by GE. Contd...15.01/- |
| 16 | Notes : (i) Complete treatment to be executed by approved applicator (Applicator to be approved by GE). (ii) The Contractor and manufacture of polymer modified mortar shall give the warranty before commencement and also for the strengths achieved in the post completion of work.(iii) The chemicals to be used in the work shall be certified by the manufacturer with whom the MOU been entered into.(iv) Hard drawn steel wire fabric will be measured and paid seperately |
| 17 | M&L for Preparation of newly plastered surfaces of walls etc., and applying three coats of white wash complete all as specified & directed. |
| 18 | Demolition of un reinforced cement concrete of any description and in any position not otherwise specially provided for complete all as specified & directed. |
| 19 | M&L for Cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in roof kerbs or mud stops, bed blocks, back filling in chowkhats, benching etc including necessary form work complete all as specified & directed. |
| 20 | Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified & directed. |
| 21 | M&L for Cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in floor topping ,for tank stage, 40mm thick, surfaces finished even and fair without using extra cement complete all as specified & directed. |
| 22 | Supply only integral water proofing compound complete all specified & as specified and as directed. |
| 23 | Taking up or down existing steel water tubing, 15mm bore alongwith connections fixed/laid in any situation, complete all as specified & directed. |
| 24 | All as per item No 22 here-in-before but 20 mm bore tubing complete all as specified & directed.. |
| 25 | M&L for GI steel water tubing, 15mm bore medium grade galvanized with all fittings and fixed to walls and celling or laid in floor, complete all as specified & directed. |
| 26 | All as per item No 24 here-in-before but 20 mm bore tubing complete all as specified & directed. |
| 27 | Fixing only, after cleaning old steel water tubing, 15 mm bore and connections in new or old position using new fittings complete all as specified & directed. (pipes obtained from item 22 to be reused). |
| 28 | All as per item No 26 here-in-before but 20 mm bore (pipes obtained from item 23 to be reused), complete all as specified & directed. |
| 29 | S&F in repair gunmetal gate valve of 20 mm dia with iron wheel head screwed both ends for iron pipe complete all as specified & directed. |
| 30 | S&F in repair gunmetal gate valve of 15 mm dia with iron wheel head screwed both ends for iron pipe complete all as specified & directed. |
| 31 | S&F in repair 500 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe all as specified in SSR Part-I complete all as specified & directed. |
| 32 | S&F in repair 1000 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe all as specified in SSR Part-I complete all as specified & directed. |
| 33 | Disconnecting existing tanks 500 ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position incl cleaning and removing all scale and dirt, from mouths of circulating pipes, etc complete all as specified & directed. |
| 34 | Disconnecting existing tanks 1000 ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position incl cleaning and removing all scale and dirt, from mouths of circulating pipes, etc. complete all as specified & directed. |
| 35 | Taking down eaves gutters and rain water pipes( any size or pattern),including all fittings heads shoes bends swan-necks etc all as specified and directed |
| 36 | S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified & directed. |
| 37 | All as per item No-35 but except pipe complete all as specified & directed. |
| 38 | S&F 110 mm dia PVC (SWR) bends any radius complete all as specified & directed. |
| 39 | Supply and fixing hard drawn steel wire fabric not exc 4 kg/sqm cut to lengths, wire mesh to be fixed and firmly anchored to the concrete surface by means of 'L' shaped mild steel shear key welded with existing reinforcement including cost of material, labour, tools and plants incl welding/L-clip/tying with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysNov 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 26 daysTender Documents