Housing Urban and Rular Development Government Departments Closing in 15 days TDR #57878655

Tender For Providing Internal And External Electrification, Ups, Laminar Flow And Split Ac Arrangements To The Additional Building For Ot With Post Operative Ward (Second And Third Floor) In Government Hospital At Cheranmahadevi In Tirunelveli Distri

Issued by Government Departments · Tirunelveli, Tamil Nadu
Tender Value
43.90 Lakhs
Estimated cost
Bid Submission
21 Oct 2026
15 days left
EMD
32000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tirunelveli → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Providing Internal And External Electrification, Ups, Laminar Flow And Split Ac Arrangements To The Additional Building For Ot With Post Operative Ward (Second And Third Floor) In Government Hospital At Cheranmahadevi In Tirunelveli District.

BOQ

Name of Work:- Providing Internal and External Electrification, UPS, Laminar Flow and Split AC arrangements to the Additional Building for OT with Post Operative ward (Second and Third floor) in Government Hospital at Cheranmahadevi in Tirunelveli District.
Sl. No. Item Description
1Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End
2Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End
3Supply and fixing of WT bulk head fitting with guard suitable with 7W / 9W LED bulb
4Supply and fixing of 300mm (12\\") sweep (light duty) AC exhaust fan complete without provision of hole in the wall
5Supply and fixing of louvers shutters arrangements for 300mm (12\\") sweep (light duty) AC exhaust fan
6Supply and fixing of 18W LED square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.
7Supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.
8Supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (Higher End) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting
9Supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed FRLS copper leads with MS clamps and with painting.
10supply and fixing of 1200mm (48\\") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 600mm down rod with fan clamp with side plates and cross arm of size 450mm (18\\")
11Supply and fixing of 3 nos.6A two module 3 pin socket , 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
12Supply and fixing of 3nos.6A two module socket , 1 no. 6/16A two module socket , 3 nos. 6A one module switch, 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
13Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
14Supply and fixing of Automatic Electrical Water Heater with copper container, with Glass Wool / Puf Insulation with MS powder coated shell suitable for 25 Litres capacity 230V / 1000W (Higher End) with ISI suitable for 230V 50c/s AC supply on suitable MS clamps with 3 core flex wire, but without plumbing work
15Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug in flush with wall with earth connection (For AC Plug)
16Supply and fixing of 32A 10KA DP MCB in sheet enclosure in flush with wall and making good of the concealed portion with earth connection. (The MCB and metal enclosure should be Higher End)
17Supply and fixing of 32A 10KA FP MCB in sheet enclosure in flush with wall and making good of the concealed portion with earth connection. (The MCB and metal enclosure should be Higher End)
18Supply and fixing of 63A 10KA FP MCB in sheet enclosure in flush with wall and making good of the concealed portion with earth connection. (The MCB and metal enclosure should be Higher End)
19Supply and fixing of 63A 10KA FP MCB in weather proof IP65/IK09 class II Door and Cabinet Type (Legrand)enclosure wall with earth connection. (The MCB and metal enclosure should be of legrand /Eq.
20Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door(metal) with 1 no. 32A DP MCB as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End
21Supply and fixing of 4 way 7 segment triple pole neutral MCB distribution board in sheet steel enclosure double door type, with metal door with IP 42 protection with 40A 4 pole MCB as incoming and 3Nos 40A DP RCCB as sub incomer and 12 Nos. 6 A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. (Higher End)
22Supply and fixing of 4 way 7 segment triple pole neutral MCB distribution board in sheet steel enclosure double door type with metal door with IP 42 protection with 63A 4 pole MCB as incoming and 3Nos 63A DP RCCB as sub incomer and 12 Nos. 6 A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. (Higher End)
23Supply and fixing of 4 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB as incoming and 2 nos. 32A 3P MCB , 6 nos. 6A to 32A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection only. Higher End
24Supply and fixing of 8 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 100A 4P MCB switch as Incoming and 4 Nos 63A TP MCB and 4 nos 32 TP MCB as outgoing in flush with wall with earth connection only. Higher End
25Supply and fixing of 8 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 100A 4P MCB switch as Incoming and 5 Nos 63A TP MCB and 3 nos 32A TP MCB as outgoing in flush with wall with earth connection only. Higher End
26Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire and making good of the concealed portion with suitable colour
27Supply and run of 2 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with contiinuous earth wire connection of 6 sq.mm copper wire and making good of the concealed portion with suitable colour
28Supply and run of 4 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 6 sq.mm copper wire and making good of the concealed portion with suitable colour
29Supply and Run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed portion.
30Supply and Run of 4 of 25 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 16 sq.mm copper wire and making good of the concealed portion.
31Supply and fixing of 3 KVA Single Phase In & Single Phase out Online UPS of Microcontroller based High frequency and Double Conversion Online Technology with inbuilt Isolation transformer system, LCD/LED Display with sultable SMF battery to provide minimum 1hour backup along with Powder coated MS Rack and interlink cables with following specifications:
321. Output Voltage 208V/220V/230V/240V AC 2. Voltage THD (Linear Load): ≤2% 3. Voltage THD (Non-Linear Load): ≤4% 4. Current THD: <10% 5. Overload : >110%, 30s turn to Bypass mode; >150% instant turn to Bypass mode SR 6. Short Circuit protection 5 cycles turn off inverter, no transfer to Bypass, provide Alarm (AC mode): 5cycles turn off Inverter, provide Alarm (Battery mode), Input fuse blown or breaker action
337. Waveform: Pure sinewave 8. Transfer time: (AC mode to Battery mode Zero) (Inverter to bypass - <4ms) 9. Efficiency: 85% to 92% 10. Noise Level: less than 50dBA @ 1meter (with fan speed control) 11. Warranty Two years on Electronics & one year on battery.The Make Should be approved by department officials before used on work.
34Supply installation and commissioning of 2200 Cfm 5.5 TR Nominal capacity factory assembled double skin ceiling mounded AHU with 50mm-45kg/cum PUF Insulated detachable panels extruded thermal break aluminium profiles filled with PUF,panel external skin preplasticized sheet, panel internal skin with 0.6mm galvanized sheet, AMCA tested DIDW backward/forward curved centrifugal fan with EFF1 rating motor drive arrangement with taper motor lock pulleys with 0.6 mm for fan and out of heavy duty vibration Isolators rubberized mounts,
35prefilters with 3ply HDPE 50mm thick filters having an efficiency of 90% 10 mic, 6row /12FPI deep DX copper cooling coll with copper header and aluminium fins,Gl mist arrestor condensate Insulated coil trough with SS-304 20G with closed 9mm cell elastomeric foam, guard for inspection door out let damper of aerofoil blades &PVC gears and flexible fire retardant canvass complete with galvanized hard ware. (Carrier/Blue Star/Daikin). The make should be approved by the departmental officials before used on work.
36Supply. Installation, commissioning of testing Laminar and Flow arrangements with HEPA Filters, Frames, etc. 8 ft X 6 ft for OT Ceiling Suspended provides ultra clean sterile CLASS 100 clean air and designed as per CLASS 5 OF ISO 14644- standards with air plenum at Aluminium powder coated 1mm thick casing with Aluminium pleat HEPA filters & 0.3 micron 99.97% efficiency and SS 304 perforated grill with 13 mm thickness XLP Insulation with Modular Housing. Frame: Aluminium, Flange type, Filter Media: Micro glass fibre, Sealant Plolyurethane with Air flow as per standards suitable for 5.5 TR.
37Design, supply, commissioning of 2200 Cfm 5.5 TR Nominal capacity DX Air-cooled Condensing outdoor unit fixed with energy efficient R410A Refrigerant scroll compressor along with grooved copper tube/aluminium fins air cooled condensor coil with anticorrosion coatings, liquid, accumulator, low noise alumimium propelle condenser fan with Fan motor etc all suitably assembled neatly in heavy duty GSS sheet metal cabinet and duly powdercoated as per standard specifications. The unit to include built in safety controls like TIP/LP switch power quality protector, in built thermal / temperature protection .The Make Should be approved by department officials before used on work.
38Supply, fabrication and fixing of MS channel for mounting the Airconditioning Indoor Unit.
39Supply, fabrication and fixing of MS channel for mounting the Airconditioning Outdoor Unit.
40Supply and filling of R410A Refrigerant Gas
41Supply and fixing of ducting made up of 22g aluminium sheet with complete angle supports angle flanges tees and bends where ever necessary etc
42Supply and providing Acoustic for initial portion of Ducting with 12mm thick fiber glass rigid board covered with Tissue Paper and Aluminium Perforated Sheet.
43Supply and fixing of extruded Aluminium powder Coated, supply and return Air Grilles/ Diffusers with volume control dampers.
44Supply and fixing of flexible Canvas connection
45Supply and fixing of Duct Mouth Dampers
46Supply and fixing of 50 mm thick Anti Vibrating Rubber Pads
47Supply and providing thermal insulation of 9 mm thick vidoflex with Aluminium Foil.
48Supply and fixing of Refrigirant piping out of hard drawn copper refrigirant pipe set of 22.20 mm size
49Supply and fixing of Refrigirant piping out of hard drawn copper refrigirant pipe set of 12.70 mm size
50Supply and providing of pipeline nitrile rubber insulation for refrigerant and drain pipe lines
51Supply and providing of 1.5sqmm copper flexible cable
52Supply and providing of 0.5sqmm 4 core flexible signal cable
53Supply and fixing of 1\\" PVC water drain pipe line
54Supply and fixing of microvee filter 600x600mm size fine microvee mesh filter with efficiency of 5 micron levél for return air.
55Supply, fabrication and fixing of Fresh air Louver made of extruded aluminium with bird screen provided with Intake louvers.
56Supply and run of 3 core 2.5 sqmm flexible copper cable for inter conecting Indoor to Outdoor unit
57Supply and fixing of 63A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with Earth connection only.
58Supply and fixing of 65 mm dia. (2 -1/2\\") GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 48W LED street light fitting with LED (Higher end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED street light fitting and SMC box with PVC unsheathed FRLS copper leads from SMC box to fitting and with painting of suitable colour .
59Supply, erection, testing and commissioning of dust and vermin proof automatic ON/OFF three phase street light control panel made up of 16 SWG CRGA sheet enclosure of suitable size with powder coating, lock & Key atrrangements and accomodating the following with necessary internal wiring as per CEA regulations:
60(a) 24 hours programmable timer switch with shortest switching time 15mins - 1No.(b) 63A FP MCB (Higher End) - 1No.(c) 63A FP Contactor (Higher End) - 1No.(d) 6A SP MCB (Higher End) - 1No.(e) 6A SP 2way Auto/Manual change over switch (L&T/Siemens/Legrand) - 1No.(f) 4way terminal block -1No.
61Supply and lixing of brass cable gland for 4 x 16 sq.mm. PVC armoured LTUG cable with earth connection.
62Supply and Laying of 4 x 16 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good
63Supply and clamping of 4 x 16 sq.mm. PVC aluminium LTUG armoured cable on post or on wall with MS clamps.
64Supply and clamping of 4 x 16 sq.mm PVC aluminium LTUG armoured cable in suitable dia Class B G.I pipe on post or on wall with MS Clamps.
65Supply and installation of air termination rod of 2mtr length of material AlMgSi of diametre 16/10 mm crimped on both the ends (Tappered Type). The rod shall be mounted with stainless steel clamp and fixing accessories. It should satiesfies IEC 62561-1 & 2 and it should Withstand Minimum wind velocity of 150m/s.
66Supply and clamping of 8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used as down conductor system with necessary Conductor Holder,glue, connectors, joints and expansion plece etc as per IEC 62561-2 recommendation and site condition
67Supply and run of Rust resistant non corossive 10 mm dia Copper Bonded Steel round conductor used for Earth termination inside the concrete and soil with necessary masonary and excavation work.
68Supply and Installation of Battery operated LCD type Lag stuing counter LCD screen shows the number of lightning strikes, hour and date of ightning events Buttons enable TIME/DATE setting and log viewing. Replaceable battery. working hle minimum five years, Complies with IEC/EN 62561-6.
69Supply and insallation Cabinet Type Class 1 and 2 Combined Model SPD in 4P enclosure box to arrest surges and overvoltages in the power linedue to lighning switching action etc. they must be installed in the incoming MCC panel / DB of the respective buling in parallel to the power circuit by using 4 of 6 Sqmm Cu(84/0.3). Model: PSV4-12.5/400TT (3 phase power network)
70Supply of Maintenance Free Copper bonded Earth rod of 3000mm length having the dia of 17.2 mm with copper coating thickness of 254 microns. The rod has been tested for Dimension, Marking, Tensile Strength, Salt mist, coating thickness, Electrical resistivity test before and after corrosion test as per IEC 62561-2.
71Supply erection, testing and commissioning of 2.0 TR (6000 K.cal/Hr) ABS Plastic Split type Inverter Air conditioner conforming to IS 1391 (Part-2) 1992 with Amdt No. 1 to 2 fitted with inverter compressor operating on non CFC refrigerant suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with 5 star rating as per BEE specification and capable of performing the functions1) Cooling 2) Dehumidifying 3) Air circulating 4) Filtering
72The installation work for the above split type AC units inculdes the following1. Mounting/ Fitting Indoor and Outdoor units at the respective locations. 2. Laying refrigerant pipeline of required length connecting both units after drilling hole/holes in the wall, if required. Thickness of copper tubing shall not be less than 0.8mm
733.Insulating the suction pipe with expanded polyethelene foam 8mm tubing 4. Laying 25mm dia flexible PVC drain pipe to throw out the condensate water being formed with in the indoor unit. 5. Leakage testing the entire system. 6. Charging refrigerant gas in the unit. 7.Suitable electric wiring to be provided with 2.5 sqmm PVC insulated copper wire between indoor units upto 6 mtrs length and up to switch with in 3 meters of the location of indoor unit. The Make Should be approved by department officials before used on work.
74Supply and Installation of 5 KVA Electronic Automatic Voltage Stabilizer (V- GUARD / equ make) with Input Voltage range of 150Volt - 285Volt and Output Voltage range 200Volts to 230 Volts with High and Low Voltage cut off and 3 minutes time delay relay with demonstration.
75Supply and laying of 5/8” and 3/8” copper pipe (Extra beyond 3 metres supplied with AC unit)
76Supply and errection of 1.5 Ton (4500 K.cal/hr) ABS Plastic Split type Inverter Air conditioner conforming to IS 1391 (Part-2) 1992 with Amdt No. 1 to 2 fitted with inverter compressor operating on refrigerant of non CFC suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with 5 star rating as per BEE specification and capable of performing the functions
771) Cooling 2) Dehumidifying 3) Air circulating4) FilteringThe installation work for the above split type AC units inculdes the following1. Mounting/Fitting Indoor and Outdoor units at the respective locations. 2. Laying refrigerant pipeline of required length connecting both units after drilling hole/holes in the wall, if required. Thickness of copper tubing shall not be less than 0.8mm
783.Insulating the suction pipe with expanded polyethelene foam 8mm tubing 4. Laying 25mm dia flexible PVC drain pipe to throw out the condensate water being formed with in the indoor unit. 5. Leakage testing the entire system. 6. Charging refrigerant gas in the unit. 7.Suitable electric wiring to be provided with 2.5 sqmm PVC insulated copper wire between indoor units upto 6 mtrs length and up to switch with in 3 meters of the location of indoor unit. The make should be approved by the department officials before used on work.
79Supply and Installation of 4 KVA Electronic Automatic Voltage Stabilizer (V-Guard/Eq) with Input Voltage range of 150Volt - 285Volt and Output Voltage range 200Volts to 230 Volts with High and Low Voltage cut off and 3 minutes time delay relay with demonstration.
80Supply and fixing of batten holder (bakelite) with 9W LED lamp.
81Supply and fixing of 375mm (15\\") sweep (light duty) AC exhaust fan complete without provision of holes in the wall.
82Supply and fixing of louvers shutters arrangements for 375mm (15\\") sweep light duty AC Exhaust fan
83Supply and run of 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in existing concealed PVC rigid pipe with connections.
84Supply and fixing of MS stand for fixing outdoor unit.
85Earthing as per PWD standard with an earth electrode of 2 metre Class 'B' GI pipe of dia not less than 32mm complete with necessary masonry work
86GST Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57878655
AUTHORITY Government Departments
TENDER VALUE 43.90 Lakhs
LAST DATE 21-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Providing Internal And External Electrification, Ups, Laminar Flow And Split Ac Arrangements To The Additional Building For Ot With Post Operative Ward (Second And Third Floor) In Government Hospital At Cheranmahadevi In Tirunelveli District.
Basic Detail
Tender No 4(1) SE/2026-27 dated 29.09.2026
Bidding Type Tender
Location
City Tirunelveli
State Tamil Nadu
Key Dates
Publish Date 06 Oct 2026
Submission Date 21 Oct 2026
Open Date 22 Oct 2026
Finance
Tender Value 43.90 Lakhs
Tender Fee Ref. Documents
EMD 32000
Exemption Not Available
Document List
BOQ_854070.xls
e7b5cc29-0042-4489-9d5e-4df8fcd79dbf.html
tenderdoccheran.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 06, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Oct 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Oct 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_854070.xls

html

e7b5cc29-0042-4489-9d5e-4df8fcd79dbf.html

pdf

tenderdoccheran.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders