Health and Family Welfare Government Departments Closing in 6 days TDR #57876871

Tender For Supply & Installation Of Walk In Cold Room

Issued by Government Departments · Thiruvananthapuram, Kerala
Tender Value
25.11 Lakhs
Estimated cost
Bid Submission
12 Oct 2026
6 days left
EMD
25200
Bank guarantee accepted
Document Fee
4484
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvananthapuram → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Supply & Installation Of Walk In Cold Room , Ppgi Puf Filled Panels As Per Spec No 3, 17 , Plain Cement Concrete Concrete Flooring 1:2:4 At Floor Stand (1 Cement: 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size) , Flooring Of Walkincold Room As Per Spec No. 5 , Door With Hinges And Emergency Safety Lock Size 900Mmx2000Mm As Per Spec No 4 , Emergency Alarm With Standard Length Of Cable As Per Spec No 4 , Two 5Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Copper Pipes For Refrigeration Unit Additional Requirement , Drain Pipe Additional Requirement , Cables For Refrigeration Unit Additional Requirement , Control Panel With Switches And Alarm As Per Spec , Vapour Proof Lamp 2Nos With Cables And Switches As Per Spec No 14 , External Light With Cables And Switches As Per Spec No 14 , Digital Data Recorder With Temperature Alarm And Sms Alert Facility For Temperature Alarm As Per Spec No 12, 13 , Ss 304 Grade 14 Gauge Shelves 6X3 Feet As Per Spec No 22 , Ss 304 Grade 14 Gauge Shelves 5X3 Feet As Per Spec No 22 , Ss 304 Grade 14 Gauge Shelves 4X3 Feet As Per Spec No 22 , Pvc Blinds For Door Way As Per Spec No 23 , Earthing And Safety Equipments : Supply And Providing Pipe Earthing As Per Is 3043 With 3.60M Long 40Mm Dia B Class Gi Pipe, Gi Funnel With Weld Mesh, Filling Requried Quantity Of Charcoal & Salt Including Construction Of Inspection Chamber With A Bed Concrete Of 1:4:8 Plain Cement Concrete Using 40Mm Broken Stone (10Cm Thick), Brick Work In Cement Mortar 1:6, Plastering The Surface Of Brick Masonry And The Exposed Surface Of Plain Cement Concrete Bed With Cement Mortar 1:4, 12Mm Thick, (The Finished Inside Dimension Shall Be 300X300X300Mm) But Excluding Test Joint, Earth Continuity Conductor To The Plate, And Covering At The Top ( In Ordinary Soil) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/Cables And Giving Connection As Required. 4.00 Mm Copper Conductor (8 Swg) , Door With Hinges And Emergency Safety Lock Size 1000Mmx2000Mm As Per Spec (Not Taken For Evaluation) , Emergency Alarm Cable Additional Requirement (Hooter) , Two 3Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Two 4Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Two 6Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Two 8Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Additional Digital Display Unit As Per Spec With Standard Length Of Cables As Per Spec , Automatic 3 Phase Change Over , Cable For Additional Digital Display Unit , Demolition Of Old Walkincold Room , Mcbs And Mcb Distribution Boards: Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper/Brass Busbar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Colour Washing Etc. As Required. 4 Way (8+12) - Double Cover Tpn Vertical Db With Provision For Fixing 4P Mcb/Isolator/Rccb/Rcbo As Incomer And Sp/Tp Mcb As Outgoing (Ip 42/43) , Supply And Fixing Of Following Rating Residual Current Circuit Breaker Having Earth Leakage Protection (Rccb) As Per Specification As Required 4 Pole 63 Amps. (415 Volts), 100Ma Sensitivity , Supply And Fixing Of Following Rating, 10 Ka, Miniature Circuit Breakers Of The Following Series As Required. 6 A To 32 A Tp Mcb, C-Curve Mcb , Supply And Fixing Of Following Rating, 10 Ka, Miniature Circuit Breakers Of The Following Series As Required. 6 A To 32 A Sp Mcb, C-Curve Mcb , Sp Mcb Blanking Plate , Cables And Cabling : Supply Of Following Size 1.1 Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Aluminium /Copper Conductor Cable Conforming To Is 7098 (Part 1) Amended Upto Date. 4 C 16 Sq.Mm Al , Supply Of Following Size 1.1 Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Aluminium /Copper Conductor Cable Conforming To Is 7098 (Part 1) Amended Upto Date. 3 C 10 Sq.Mm Al , Supplying And Making End Termination With Brass Compression Gland And Aluminium/Copper Lugs For Following Size Of Xlpe Insulated Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade As Required-4C 25 Sqmm Sq.Mm Al , Laying And Clamping Of 1No. Pvc Insulated And Pvc Sheathed Armoured Power Cable, 1.1Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages Colour Washing Etc. As Required 4 Core Cable Of Size Exceeding 6Sq.Mm But Not Exceeding 25 Sq.Mm With Company Fabricated Saddles. , External Over Head Canopy For 2 Outdoor Units If The Compressor Units Are Placed In Open Area , Stablizer 15 Kva 3 Phase Wide Range As Per Spec

AI Tender Summary

OUR REF NO 57876871
AUTHORITY Government Departments
TENDER VALUE 25.11 Lakhs
LAST DATE 12-10-2026
Authority
Authority Name Kerala Medical Services Corporation Limited
Work Description Tender For Supply & Installation Of Walk In Cold Room , Ppgi Puf Filled Panels As Per Spec No 3, 17 , Plain Cement Concrete Concrete Flooring 1:2:4 At Floor Stand (1 Cement: 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size) , Flooring Of Walkincold Room As Per Spec No. 5 , Door With Hinges And Emergency Safety Lock Size 900Mmx2000Mm As Per Spec No 4 , Emergency Alarm With Standard Length Of Cable As Per Spec No 4 , Two 5Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Copper Pipes For Refrigeration Unit Additional Requirement , Drain Pipe Additional Requirement , Cables For Refrigeration Unit Additional Requirement , Control Panel With Switches And Alarm As Per Spec , Vapour Proof Lamp 2Nos With Cables And Switches As Per Spec No 14 , External Light With Cables And Switches As Per Spec No 14 , Digital Data Recorder With Temperature Alarm And Sms Alert Facility For Temperature Alarm As Per Spec No 12, 13 , Ss 304 Grade 14 Gauge Shelves 6X3 Feet As Per Spec No 22 , Ss 304 Grade 14 Gauge Shelves 5X3 Feet As Per Spec No 22 , Ss 304 Grade 14 Gauge Shelves 4X3 Feet As Per Spec No 22 , Pvc Blinds For Door Way As Per Spec No 23 , Earthing And Safety Equipments : Supply And Providing Pipe Earthing As Per Is 3043 With 3.60M Long 40Mm Dia B Class Gi Pipe, Gi Funnel With Weld Mesh, Filling Requried Quantity Of Charcoal & Salt Including Construction Of Inspection Chamber With A Bed Concrete Of 1:4:8 Plain Cement Concrete Using 40Mm Broken Stone (10Cm Thick), Brick Work In Cement Mortar 1:6, Plastering The Surface Of Brick Masonry And The Exposed Surface Of Plain Cement Concrete Bed With Cement Mortar 1:4, 12Mm Thick, (The Finished Inside Dimension Shall Be 300X300X300Mm) But Excluding Test Joint, Earth Continuity Conductor To The Plate, And Covering At The Top ( In Ordinary Soil) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/Cables And Giving Connection As Required. 4.00 Mm Copper Conductor (8 Swg) , Door With Hinges And Emergency Safety Lock Size 1000Mmx2000Mm As Per Spec (Not Taken For Evaluation) , Emergency Alarm Cable Additional Requirement (Hooter) , Two 3Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Two 4Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Two 6Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Two 8Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Additional Digital Display Unit As Per Spec With Standard Length Of Cables As Per Spec , Automatic 3 Phase Change Over , Cable For Additional Digital Display Unit , Demolition Of Old Walkincold Room , Mcbs And Mcb Distribution Boards: Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper/Brass Busbar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Colour Washing Etc. As Required. 4 Way (8+12) - Double Cover Tpn Vertical Db With Provision For Fixing 4P Mcb/Isolator/Rccb/Rcbo As Incomer And Sp/Tp Mcb As Outgoing (Ip 42/43) , Supply And Fixing Of Following Rating Residual Current Circuit Breaker Having Earth Leakage Protection (Rccb) As Per Specification As Required 4 Pole 63 Amps. (415 Volts), 100Ma Sensitivity , Supply And Fixing Of Following Rating, 10 Ka, Miniature Circuit Breakers Of The Following Series As Required. 6 A To 32 A Tp Mcb, C-Curve Mcb , Supply And Fixing Of Following Rating, 10 Ka, Miniature Circuit Breakers Of The Following Series As Required. 6 A To 32 A Sp Mcb, C-Curve Mcb , Sp Mcb Blanking Plate , Cables And Cabling : Supply Of Following Size 1.1 Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Aluminium /Copper Conductor Cable Conforming To Is 7098 (Part 1) Amended Upto Date. 4 C 16 Sq.Mm Al , Supply Of Following Size 1.1 Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Aluminium /Copper Conductor Cable Conforming To Is 7098 (Part 1) Amended Upto Date. 3 C 10 Sq.Mm Al , Supplying And Making End Termination With Brass Compression Gland And Aluminium/Copper Lugs For Following Size Of Xlpe Insulated Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade As Required-4C 25 Sqmm Sq.Mm Al , Laying And Clamping Of 1No. Pvc Insulated And Pvc Sheathed Armoured Power Cable, 1.1Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages Colour Washing Etc. As Required 4 Core Cable Of Size Exceeding 6Sq.Mm But Not Exceeding 25 Sq.Mm With Company Fabricated Saddles. , External Over Head Canopy For 2 Outdoor Units If The Compressor Units Are Placed In Open Area , Stablizer 15 Kva 3 Phase Wide Range As Per Spec
Basic Detail
Tender No KMSCL/EP/603/2026
Bidding Type Tender
Location
City Thiruvananthapuram
State Kerala
Key Dates
Publish Date 05 Oct 2026
Submission Date 12 Oct 2026
Open Date 14 Oct 2026
Finance
Tender Value 25.11 Lakhs
Tender Fee 4484
EMD 25200
Exemption Available
Document List
b6e5f3bc-f3a8-4b94-b45a-c2db95436ff7.html
BOQ_1487712.xls
Supplierdetails.xls
Tendernotice_1.pdf
WalkinColdRoom.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Oct 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

b6e5f3bc-f3a8-4b94-b45a-c2db95436ff7.html

xls

BOQ_1487712.xls

xls

Supplierdetails.xls

pdf

Tendernotice_1.pdf

pdf

WalkinColdRoom.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender