Tender For Supply, Installation, Testing And Commissioning Of08mtr Low Mast With 05 Nos Of 150W Led Flood Lights At Peral Kannur Juma Masjidjunction (Ward -10) In Puthige Grama Panchayat
Tender Value
1.56 Lakhs
Estimated cost
Bid Submission
13 Oct 2026
0 days left
EMD
3900
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kasaragod → Kerala
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply, Installation, Testing And Commissioning Of08mtr Low Mast With 05 Nos Of 150W Led Flood Lights At Peral Kannur Juma Masjidjunction (Ward -10) In Puthige Grama Panchayat
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORK |
| 2 | 2.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 3 | 4.1.8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 5 | 5.9.1Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 6 | 5.1.2Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 7 | 2.25Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 8 | ELECTRICAL WORK |
| 9 | 90.15.1.1Supply installation testing and commissioning of Octogaonal Pole made of hot dipgalvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm baseplate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixedhead frame including round arm luminary carriage suitable to install 4/6 nosluminaries in symmetrical arrangement including connector foundation bolt 4 nosexisting RCC foundation and junction box etc, complete 8 Meters |
| 10 | 90.15.4.9Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 11 | 90.14.1.2Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) |
| 12 | 90.14.3.2Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet |
| 13 | 90.14.5Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 14 | OD355459/2025-2026Supply and fixing of Surge protector device of IP 20,Mounting type: Screw,Voltageprotection level(UP),Nominal voltage: 230V ,UOC:10KV,L-N:7 KV,L-PE:7 KV,NPE:7 KV,Nominal discharge current (8/20):10 KA,Total discharge current (8/20):60KA, Response time :<35 ns, Ta: -10-55. |
| 15 | OD355461/2025-2026Supply and fixing HRC fuse base of 20/32 A using suitable nut and bolt, 32 A 2- wayneutral links mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVCinsulated single core copper conductor cable. |
| 16 | 2.14.2Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 17 | 2.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 18 | 2.10.3Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole |
| 19 | 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps |
| 20 | 90.6.5.11Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVCsheathed 650/1100 V grade copper conductor round flexible cables conforming to IS694 part I 1960 in the existing surface / recess conduit as required including givingnecessary connections of the following sizes.3 core 1.50 sq mm |
| 21 | 1.17.11Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x2.5 sq. Mm |
| 22 | 5.3Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories,and providing masonry enclosure with cover plate having locking arrangement andwatering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. |
| 23 | OD355462/2025-2026Supplying and laying 25 mm X 3 mm G.I strip at 0.50 metre below groundincluding connection/ terminating with G.I. nut, bolt, spring, washer etc. asrequired. |
| 24 | 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along with wiring/cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 25 | 90.16.5.3Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.3.15 mm (10 SWG) |
| 26 | 90.12.1.13Supply & laying of one number PVC insulated and PVC sheathed armouredaluminium power cable of 1.1KV grade of the following sizes in ground includingexcavation of trench of size 35 x 75 cm, refilling the trench etc. as required butexcluding sand cushioning and protective covering (in ordinary soil).3 core 6 sq mm |
| 27 | 90.12.9.2Supplying, laying and jointing of the following sizes of double wall corrugated (DWC)pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection tounderground power cables with all required accessories in ground in the existingtrench50/38 mm or nearest size |
| 28 | 9.1.1Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.2 X 6 sq. mm (19mm) |
| 29 | OD355460/2025-2026Supply and fixing of granite plaque and ACP sheet engraved Name of MP and year ofproject Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayOct 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender