New and Renewable Energy Government Departments Closing in 5 days TDR #57874464

Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Dae Kalpakkam Township; Hvac, Comprehensive Maintenance Contract For Air Cooled Packaged Air Conditioners And Kitchen Ventilation System Installed A

Issued by Government Departments · Chengalpattu, Tamil Nadu
Tender Value
48.88 Lakhs
Estimated cost
Bid Submission
22 Oct 2026
5 days left
EMD
98000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chengalpattu → Tamil Nadu
EMD Exemption
Available
Quantity
1

Project Description

Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Dae Kalpakkam Township; Hvac, Comprehensive Maintenance Contract For Air Cooled Packaged Air Conditioners And Kitchen Ventilation System Installed At Kalpakkam During Th.. - Comprehensive Maintenance For Bluestar Make Of 16.5 Tr ( 5.5 Tr X 3Nos. Circuit) Capacity Air Cooled Packaged Air Conditioner. (Running In Good Condition). It Includes Replacement Of Defective Bearings & Belts , Cleaning Of Ac Plant Room ,Air Filters, Grills, Diffuser And Evaporator And Condenser Coil, Lubricating Of Moving Parts, Checking Of Refrigerant Suction And Discharge Pressure, Measuring Current, Repair And Replacement Of Pc Board, Capacitor, Fan Motors, Drier, Evaporator Coil, Condenser Coil, Scroll Compressor, All Type Of Electrical And Mechanical Items Etc, All Complete As Per Specification And As Directed By Engineer In Charge.Note: Rate Shall Be Quoted For Camc Per System Per Year. , Comprehensive Maintenance Contract For Packaged Air Conditioners Installed In The Year 2018 To 2020 (5 Systems X 2 Years = 10 Nos.) , Comprehensive Maintenance Contract For Packaged Air Conditioners Installed In The Year 2015 To 2017 (8 Systems X 2 Years = 16 Nos.) , Comprehensive Maintenance Contract For Packaged Air Conditioners Installed In The Year Of 2007 (2 Systems X 2 Years = 4 Nos.) , Comprehensive Maintenance For Bluestar Make Of 11.0 Tr ( 5.5 Tr X 2 Nos. Circuit) Capacity Air Cooled Packaged Air Conditioner And Ceiling Suspended Ductable Packaged Aircondtioners . (Running In Good Condition). It Includes Replacement Of Defective Bearings & Belts , Cleaning Of Ac Plant Room ,Air Filters, Grills, Diffuser And Evaporator And Condenser Coil, Lubricating Of Moving Parts, Checking Of Refrigerant Suction And Discharge Pressure, Measuring Current, Repair And Replacement Of Pc Board, Capacitor, Fan Motors, Drier, Evaporator Coil, Condenser Coil, Scroll Compressor, All Type Of Electrical And Mechanical Items Etc, All Complete As Per Specification And As Directed By Engineer In Charge.Note: Rate Shall Be Quoted For Camc Per System Per Year. , Comprehensive Maintenance Contract For Packaged Air Conditioners Installed In The Year 2020 To 2023 (2 Systems X 2 Years = 4 Nos.) , Comprehensive Maintenance Contract For Packaged Air Conditioners Installed In The Year 2018 To 2020 (11 Systems X 2 Years = 22 Nos.) , Comprehensive Maintenance Contract For Packaged Air Conditioners Installed In The Year 2014 To 2017 (4 Systems X 2 Years = 8 Nos.) , Comprehensive Maintenance Contract For Blue Star Make Dx Type Air Handling Unit Of 11 Tr ( 5.5 Tr X 2 Nos. Circuit) Capacity. (Running In Good Condition). It Includes Replacement Of Defective Bearings & Belts , Cleaning Of Ac Plant Room, Supply & Return Air Grills And Diffusers, Air Filters, Evaporator And Condenser Coil, Scroll Compressor , Ac System Control Panel , All Type Of Electrical And Mechanical Items Etc., All Complete As Per Specification And As Directed By Engineer In Charge. Note:1) Dx Type Ahu With Condensing Unit Of Capacity 5.5 Tr X 2 Nos. Installed In The Year 2020.2) Rate Shall Be Quoted For Camc Per System Per Year. 3) 2 Systems X 2 Years = 4 Nos. , Comprehensive Maintenance Contract For Blue Star Make Dx Type Air Handling Unit Of 17Tr ( 8.5 Tr X 2 Nos. Circuit) Capacity. (Running In Good Condition). It Includes Replacement Of Defective Bearings & Belts , Cleaning Of Ac Plant Room, Supply & Return Air Grills And Diffusers, Air Filters, Evaporator And Condenser Coil, Scroll Compressor , Ac System Control Panel , All Type Of Electrical And Mechanical Items Etc., All Complete As Per Specification And As Directed By Engineer In Charge.Note: 1) Dx Type Ahu With Condensing Unit Of Capacity 8.5 Tr X 2 Nos. Installed In The Year 2025.2) Rate Shall Be Quoted For Camc Per System Per Year. 3) 2 Systems X 2 Years = 4 Nos. , Comprehensive Maintenance Contract For Bluestar Make Of 5.0 Tr (2.5 Tr X 2 Nos. Circuit) Capacity Ductable & Multi Split Air Conditioners. (Running In Good Condition). It Includes Cleaning Of Supply & Return Air Grilles, Diffusers, Air Filters, Evaporator And Condenser Coil, Lubricating Of Moving Parts, Checking Of Refrigerant Suction And Discharge Pressure, Measuring Current, Repair And Replacement Of Pc Board, Capacitor, Fan Motors, Drier, Evaporator Coil, Condenser Coil, Rotary/Reciprocating/Scroll Compressor, All Type Of Electrical And Mechanical Items, Etc, All Complete As Per Specification And As Directed By Engineer In Charge.Note: 1) Rate Shall Be Quoted For Camc Per System Per Year. 2) 5 Systems X 2 Years = 10 Nos. , Comprehensive Maintenance Contract For Bluestar Make Of 3.0 Tr Capacity Mega Split Air Conditioners. (Running In Good Condition). It Includes Cleaning Of Air Filters, Evaporator And Condenser Coil, Lubricating Of Moving Parts, Checking Of Refrigerant Suction And Discharge Pressure, Measuring Current, Repair And Replacement Of Pc Board, Capacitor, Fan Motors, Drier, Evaporator Coil, Condenser Coil, Rotary/Reciprocating/Scroll Compressor, All Type Of Electrical And Mechanical Items, Etc, All Complete As Per Specification And As Directed By Engineer In Charge.Note: 1) Rate Shall Be Quoted For Camc Per System Per Year. 2) 25 Systems X 2 Years = 50 Nos. , Comprehensive Maintenance Contract For Kitchen Ventilation System Installed In Various Location Of Kalpakkam Township ( Running In Good Condition). It Includes Cleaning Of Baffle Filters, Grilles, Replacement Of Defective Bearings, Belts And Capacitor, Fan Motor, Pc Board All Type Of Electrical And Mechanical Items, Painting Of Ducts And Fan Blowers Etc., All Complete As Per Specification And As Directed By Engineer In Charge. Note:1) Each System Have Exhaust Blower 5 Hp, Fresh Air Blower 3 Hp And Cleaning Of Baffle S.S Filters.2) Rate Shall Be Quoted For Camc Per System Per Year. 3) 3 Systems X 2 Years = 6 Nos. , Painting Of Packaged Air Conditioners Outdoor Unit Of Capacity 5.5 Tr. The Work Shall Includes Cleaning Of Said Units, Scrubbing And Spray Painting Of Sheet Metal Parts Including Interior And Exterior With One Coat Red Oxide Paint And Two Coat Of Epoxy Paint., All Complete As Per Specification And As Directed By Engineer In Charge. , Tinkering Of Packaged Air Conditioners Outdoor Unit Of Capacity 5.5 Tr., It Includes Minor Fabrication, Tinkering With White Metal Paste Etc., All Complete As Per Specification And As Directed By Engineer In Charge. , Supply, Installation And Leak Testing Of Air Cooled Anti Corrosive Coated Blue Finned Condenser Coils For Packaged Ac / Ductable Ac As Per The Specification And As Required. Air-Cooled Condenser Coil Shall Be A Compact Coil Made Using Latest Advanced Copper Tubes With Anti Corrosive/ Hydrophilic Coated Aluminium Fins As Per The Original Installed In The Above Ac Units. Copper Tubes Shall Be Bullet Expanded Into Aluminium Fins For Mechanical Bonding. Independent Sub Cooling Circuit Shall Be Provided In Each Coils To Improve Eer. Copper Tube With Aluminium Blue Finned 14-16 Fpi, Condenser Coil , Fabrication, Supply And Installation Of Double Skin Air Handling Units With Inner Skin Of 0.8Mm Plain Ss & Outer Skin Of 0.8Mm Precoated Ss Sheets With 25Mm Thick Puf Insulated Panels Density Of Not Less Than 40±2 Kg/M3 . All Ahu`S Shall Be With Thermal Break Profile Constructed With Internal Coving. Insulation Shall Be Spread Equal Across The Panel To Avoid Any Air Pocket. All Panels Shall Be Sealed Against The Framework. The Panel Shall Be Mounted Flush With The Frame Members To Create Smooth Surface Inside And Outside. (Ahu Size: 4000L X 2000W X 1000H) , Safely Dismantling Of Old Dx Type Air Handling Unit, Air Cooled Condensers, Evaporator Coils, Blower With Motor, 3 Stage Filter Assembly And Associated Ducting, D Ers And Supports, Etc., From Operation Theatre-1 Of Dae Hospital, Gso, All Complete As Per The Scope And As Directed By Engineer In Charge.

BOQ

Sl. No. Item TitleItem Description
1Comprehensive maintenance for Bluestar make of 16.5 TR ( 5.5 TR X 3nos. circuit) capacity air cooled packaged air conditioner. (running in good condition). It includes replacement of defective bearings & belts , cleaning of AC plant room ,air filters, grills, diffuser and evaporator and condenser coil, lubricating of moving parts, checking of refrigerant suction and discharge pressure, measuring current, repair and replacement of PC board, capacitor, fan motors, drier, evaporator coil, condenser coil, scroll compressor, all type of electrical and mechanical items etc, all complete as per specification and as directed by Engineer in charge.Note: Rate shall be quoted for CAMC per system per year.Comprehensive maintenance for Bluestar make of 16.5 TR ( 5.5 TR X 3nos. circuit) capacity air cooled packaged air conditioner. (running in good condition). It includes replacement of defective bearings & belts , cleaning of AC plant room ,air filters, grills, diffuser and evaporator and condenser coil, lubricating of moving parts, checking of refrigerant suction and discharge pressure, measuring current, repair and replacement of PC board, capacitor, fan motors, drier, evaporator coil, condenser coil, scroll compressor, all type of electrical and mechanical items etc, all complete as per specification and as directed by Engineer in charge.Note: Rate shall be quoted for CAMC per system per year.
2Comprehensive Maintenance Contract for packaged air conditioners installed in the year 2018 to 2020 (5 Systems x 2 Years = 10 Nos.)Comprehensive Maintenance Contract for packaged air conditioners installed in the year 2018 to 2020 (5 Systems x 2 Years = 10 Nos.)
3Comprehensive Maintenance Contract for packaged air conditioners installed in the year 2015 to 2017 (8 Systems x 2 Years = 16 Nos.)Comprehensive Maintenance Contract for packaged air conditioners installed in the year 2015 to 2017 (8 Systems x 2 Years = 16 Nos.)
4Comprehensive Maintenance Contract for packaged air conditioners installed in the year of 2007 (2 Systems x 2 Years = 4 Nos.)Comprehensive Maintenance Contract for packaged air conditioners installed in the year of 2007 (2 Systems x 2 Years = 4 Nos.)
5Comprehensive maintenance for Bluestar make of 11.0 TR ( 5.5 TR X 2 Nos. circuit) capacity air cooled packaged air conditioner and ceiling suspended ductable packaged aircondtioners . (running in good condition). It includes replacement of defective bearings & belts , cleaning of AC plant room ,air filters, grills, diffuser and evaporator and condenser coil, lubricating of moving parts, checking of refrigerant suction and discharge pressure, measuring current, repair and replacement of PC board, capacitor, fan motors, drier, evaporator coil, condenser coil, scroll compressor, all type of electrical and mechanical items etc, all complete as per specification and as directed by Engineer in charge.Note: Rate shall be quoted for CAMC per system per year.Comprehensive maintenance for Bluestar make of 11.0 TR ( 5.5 TR X 2 Nos. circuit) capacity air cooled packaged air conditioner and ceiling suspended ductable packaged aircondtioners . (running in good condition). It includes replacement of defective bearings & belts , cleaning of AC plant room ,air filters, grills, diffuser and evaporator and condenser coil, lubricating of moving parts, checking of refrigerant suction and discharge pressure, measuring current, repair and replacement of PC board, capacitor, fan motors, drier, evaporator coil, condenser coil, scroll compressor, all type of electrical and mechanical items etc, all complete as per specification and as directed by Engineer in charge.Note: Rate shall be quoted for CAMC per system per year.
6Comprehensive Maintenance Contract for packaged air conditioners installed in the year 2020 to 2023 (2 Systems x 2 Years = 4 Nos.)Comprehensive Maintenance Contract for packaged air conditioners installed in the year 2020 to 2023 (2 Systems x 2 Years = 4 Nos.)
7Comprehensive Maintenance Contract for packaged air conditioners installed in the year 2018 to 2020 (11 Systems x 2 Years = 22 Nos.)Comprehensive Maintenance Contract for packaged air conditioners installed in the year 2018 to 2020 (11 Systems x 2 Years = 22 Nos.)
8Comprehensive Maintenance Contract for packaged air conditioners installed in the year 2014 to 2017 (4 Systems x 2 Years = 8 Nos.)Comprehensive Maintenance Contract for packaged air conditioners installed in the year 2014 to 2017 (4 Systems x 2 Years = 8 Nos.)
9Comprehensive maintenance contract for Blue star make DX type Air Handling unit of 11 TR ( 5.5 TR X 2 Nos. circuit) capacity. (running in good condition). It includes replacement of defective bearings & belts , cleaning of AC plant room, supply & return air grills and diffusers, air filters, evaporator and condenser coil, scroll compressor , AC system control panel , all type of electrical and mechanical items etc., all complete as per specification and as directed by Engineer in Charge. Note:1) DX type AHU with condensing unit of capacity 5.5 TR x 2 nos. installed in the year 2020.2) Rate shall be quoted for CAMC per system per year. 3) 2 Systems x 2 Years = 4 Nos.Comprehensive maintenance contract for Blue star make DX type Air Handling unit of 11 TR ( 5.5 TR X 2 Nos. circuit) capacity. (running in good condition). It includes replacement of defective bearings & belts , cleaning of AC plant room, supply & return air grills and diffusers, air filters, evaporator and condenser coil, scroll compressor , AC system control panel , all type of electrical and mechanical items etc., all complete as per specification and as directed by Engineer in Charge. Note:1) DX type AHU with condensing unit of capacity 5.5 TR x 2 nos. installed in the year 2020.2) Rate shall be quoted for CAMC per system per year. 3) 2 Systems x 2 Years = 4 Nos.
10Comprehensive maintenance contract for Blue star make DX type Air Handling unit of 17TR ( 8.5 TR X 2 Nos. circuit) capacity. (running in good condition). It includes replacement of defective bearings & belts , cleaning of AC plant room, supply & return air grills and diffusers, air filters, evaporator and condenser coil, scroll compressor , AC system control panel , all type of electrical and mechanical items etc., all complete as per specification and as directed by Engineer in Charge.Note: 1) DX type AHU with condensing unit of capacity 8.5 TR x 2 nos. installed in the year 2025.2) Rate shall be quoted for CAMC per system per year. 3) 2 Systems x 2 Years = 4 Nos.Comprehensive maintenance contract for Blue star make DX type Air Handling unit of 17TR ( 8.5 TR X 2 Nos. circuit) capacity. (running in good condition). It includes replacement of defective bearings & belts , cleaning of AC plant room, supply & return air grills and diffusers, air filters, evaporator and condenser coil, scroll compressor , AC system control panel , all type of electrical and mechanical items etc., all complete as per specification and as directed by Engineer in Charge.Note: 1) DX type AHU with condensing unit of capacity 8.5 TR x 2 nos. installed in the year 2025.2) Rate shall be quoted for CAMC per system per year. 3) 2 Systems x 2 Years = 4 Nos.
11Comprehensive Maintenance Contract for Bluestar make of 5.0 TR (2.5 TR X 2 Nos. circuit) capacity ductable & multi split air conditioners. (running in good condition). It includes cleaning of supply & return air grilles, diffusers, air filters, evaporator and condenser coil, lubricating of moving parts, checking of refrigerant suction and discharge pressure, measuring current, repair and replacement of PC board, capacitor, fan motors, drier, evaporator coil, condenser coil, Rotary/Reciprocating/scroll compressor, all type of electrical and mechanical items, etc, all complete as per specification and as directed by Engineer in charge.Note: 1) Rate shall be quoted for CAMC per system per year. 2) 5 Systems x 2 Years = 10 Nos.Comprehensive Maintenance Contract for Bluestar make of 5.0 TR (2.5 TR X 2 Nos. circuit) capacity ductable & multi split air conditioners. (running in good condition). It includes cleaning of supply & return air grilles, diffusers, air filters, evaporator and condenser coil, lubricating of moving parts, checking of refrigerant suction and discharge pressure, measuring current, repair and replacement of PC board, capacitor, fan motors, drier, evaporator coil, condenser coil, Rotary/Reciprocating/scroll compressor, all type of electrical and mechanical items, etc, all complete as per specification and as directed by Engineer in charge.Note: 1) Rate shall be quoted for CAMC per system per year. 2) 5 Systems x 2 Years = 10 Nos.
12Comprehensive Maintenance Contract for Bluestar make of 3.0 TR capacity Mega split air conditioners. (running in good condition). It includes cleaning of air filters, evaporator and condenser coil, lubricating of moving parts, checking of refrigerant suction and discharge pressure, measuring current, repair and replacement of PC board, capacitor, fan motors, drier, evaporator coil, condenser coil, Rotary/Reciprocating/Scroll compressor, all type of electrical and mechanical items, etc, all complete as per specification and as directed by Engineer in charge.Note: 1) Rate shall be quoted for CAMC per system per year. 2) 25 Systems x 2 Years = 50 Nos.Comprehensive Maintenance Contract for Bluestar make of 3.0 TR capacity Mega split air conditioners. (running in good condition). It includes cleaning of air filters, evaporator and condenser coil, lubricating of moving parts, checking of refrigerant suction and discharge pressure, measuring current, repair and replacement of PC board, capacitor, fan motors, drier, evaporator coil, condenser coil, Rotary/Reciprocating/Scroll compressor, all type of electrical and mechanical items, etc, all complete as per specification and as directed by Engineer in charge.Note: 1) Rate shall be quoted for CAMC per system per year. 2) 25 Systems x 2 Years = 50 Nos.
13Comprehensive Maintenance Contract for kitchen ventilation system installed in various location of Kalpakkam Township ( running in good condition). It includes cleaning of baffle filters, grilles, replacement of defective bearings, belts and capacitor, fan motor, PC board all type of electrical and mechanical items, painting of ducts and fan blowers etc., all complete as per specification and as directed by Engineer in Charge. Note:1) Each system have Exhaust blower 5 hp, fresh air blower 3 hp and cleaning of baffle S.S filters.2) Rate shall be quoted for CAMC per system per year. 3) 3 Systems x 2 Years = 6 Nos.Comprehensive Maintenance Contract for kitchen ventilation system installed in various location of Kalpakkam Township ( running in good condition). It includes cleaning of baffle filters, grilles, replacement of defective bearings, belts and capacitor, fan motor, PC board all type of electrical and mechanical items, painting of ducts and fan blowers etc., all complete as per specification and as directed by Engineer in Charge. Note:1) Each system have Exhaust blower 5 hp, fresh air blower 3 hp and cleaning of baffle S.S filters.2) Rate shall be quoted for CAMC per system per year. 3) 3 Systems x 2 Years = 6 Nos.
14Painting of packaged air conditioners outdoor unit of capacity 5.5 TR. The work shall includes cleaning of said units, scrubbing and spray painting of sheet metal parts including interior and exterior with one coat red oxide paint and two coat of epoxy paint., all complete as per specification and as directed by Engineer in charge.Painting of packaged air conditioners outdoor unit of capacity 5.5 TR. The work shall includes cleaning of said units, scrubbing and spray painting of sheet metal parts including interior and exterior with one coat red oxide paint and two coat of epoxy paint., all complete as per specification and as directed by Engineer in charge.
15Tinkering of packaged air conditioners outdoor unit of capacity 5.5 TR., It includes minor fabrication, tinkering with white metal paste etc., all complete as per specification and as directed by Engineer in charge.Tinkering of packaged air conditioners outdoor unit of capacity 5.5 TR., It includes minor fabrication, tinkering with white metal paste etc., all complete as per specification and as directed by Engineer in charge.
16Supply, installation and leak testing of air cooled anti corrosive coated blue finned Condenser coils for Packaged AC / Ductable AC as per the specification and as required. Air-cooled condenser coil shall be a compact coil made using latest advanced copper tubes with anti corrosive/ hydrophilic coated aluminium fins as per the original installed in the above AC units. Copper tubes shall be bullet expanded into aluminium fins for mechanical bonding. Independent sub cooling circuit shall be provided in each coils to improve EER. Copper tube with aluminium blue finned 14-16 FPI, Condenser coilSupply, installation and leak testing of air cooled anti corrosive coated blue finned Condenser coils for Packaged AC / Ductable AC as per the specification and as required. Air-cooled condenser coil shall be a compact coil made using latest advanced copper tubes with anti corrosive/ hydrophilic coated aluminium fins as per the original installed in the above AC units. Copper tubes shall be bullet expanded into aluminium fins for mechanical bonding. Independent sub cooling circuit shall be provided in each coils to improve EER. Copper tube with aluminium blue finned 14-16 FPI, Condenser coil
17Fabrication, supply and installation of Double skin Air handling units with inner skin of 0.8mm plain SS & outer skin of 0.8mm precoated SS sheets with 25mm thick PUF insulated panels density of not less than 40±2 kg/m3 . All AHU`s shall be with thermal break profile constructed with internal coving. Insulation shall be spread equal across the panel to avoid any air pocket. All panels shall be sealed against the framework. The Panel shall be mounted flush with the frame members to create smooth surface inside and outside. (AHU Size: 4000L x 2000W x 1000H)Fabrication, supply and installation of Double skin Air handling units with inner skin of 0.8mm plain SS & outer skin of 0.8mm precoated SS sheets with 25mm thick PUF insulated panels density of not less than 40±2 kg/m3 . All AHU`s shall be with thermal break profile constructed with internal coving. Insulation shall be spread equal across the panel to avoid any air pocket. All panels shall be sealed against the framework. The Panel shall be mounted flush with the frame members to create smooth surface inside and outside. (AHU Size: 4000L x 2000W x 1000H)
18Safely dismantling of old DX type Air handling unit, air cooled condensers, evaporator coils, Blower with motor, 3 stage filter assembly and associated ducting, dampers and supports, etc., from Operation Theatre-1 of DAE Hospital, GSO, all complete as per the scope and as directed by Engineer in charge.Safely dismantling of old DX type Air handling unit, air cooled condensers, evaporator coils, Blower with motor, 3 stage filter assembly and associated ducting, dampers and supports, etc., from Operation Theatre-1 of DAE Hospital, GSO, all complete as per the scope and as directed by Engineer in charge.

AI Tender Summary

OUR REF NO 57874464
AUTHORITY Government Departments
TENDER VALUE 48.88 Lakhs
LAST DATE 22-10-2026
Authority
Authority Name Department Of Atomic Energy
Work Description Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Dae Kalpakkam Township; Hvac, Comprehensive Maintenance Contract For Air Cooled Packaged Air Conditioners And Kitchen Ventilation System Installed At Kalpakkam During Th.. - Comprehensive Maintenance For Bluestar Make Of 16.5 Tr ( 5.5 Tr X 3Nos. Circuit) Capacity Air Cooled Packaged Air Conditioner. (Running In Good Condition). It Includes Replacement Of Defective Bearings & Belts , Cleaning Of Ac Plant Room ,Air Filters, Grills, Diffuser And Evaporator And Condenser Coil, Lubricating Of Moving Parts, Checking Of Refrigerant Suction And Discharge Pressure, Measuring Current, Repair And Replacement Of Pc Board, Capacitor, Fan Motors, Drier, Evaporator Coil, Condenser Coil, Scroll Compressor, All Type Of Electrical And Mechanical Items Etc, All Complete As Per Specification And As Directed By Engineer In Charge.Note: Rate Shall Be Quoted For Camc Per System Per Year. , Comprehensive Maintenance Contract For Packaged Air Conditioners Installed In The Year 2018 To 2020 (5 Systems X 2 Years = 10 Nos.) , Comprehensive Maintenance Contract For Packaged Air Conditioners Installed In The Year 2015 To 2017 (8 Systems X 2 Years = 16 Nos.) , Comprehensive Maintenance Contract For Packaged Air Conditioners Installed In The Year Of 2007 (2 Systems X 2 Years = 4 Nos.) , Comprehensive Maintenance For Bluestar Make Of 11.0 Tr ( 5.5 Tr X 2 Nos. Circuit) Capacity Air Cooled Packaged Air Conditioner And Ceiling Suspended Ductable Packaged Aircondtioners . (Running In Good Condition). It Includes Replacement Of Defective Bearings & Belts , Cleaning Of Ac Plant Room ,Air Filters, Grills, Diffuser And Evaporator And Condenser Coil, Lubricating Of Moving Parts, Checking Of Refrigerant Suction And Discharge Pressure, Measuring Current, Repair And Replacement Of Pc Board, Capacitor, Fan Motors, Drier, Evaporator Coil, Condenser Coil, Scroll Compressor, All Type Of Electrical And Mechanical Items Etc, All Complete As Per Specification And As Directed By Engineer In Charge.Note: Rate Shall Be Quoted For Camc Per System Per Year. , Comprehensive Maintenance Contract For Packaged Air Conditioners Installed In The Year 2020 To 2023 (2 Systems X 2 Years = 4 Nos.) , Comprehensive Maintenance Contract For Packaged Air Conditioners Installed In The Year 2018 To 2020 (11 Systems X 2 Years = 22 Nos.) , Comprehensive Maintenance Contract For Packaged Air Conditioners Installed In The Year 2014 To 2017 (4 Systems X 2 Years = 8 Nos.) , Comprehensive Maintenance Contract For Blue Star Make Dx Type Air Handling Unit Of 11 Tr ( 5.5 Tr X 2 Nos. Circuit) Capacity. (Running In Good Condition). It Includes Replacement Of Defective Bearings & Belts , Cleaning Of Ac Plant Room, Supply & Return Air Grills And Diffusers, Air Filters, Evaporator And Condenser Coil, Scroll Compressor , Ac System Control Panel , All Type Of Electrical And Mechanical Items Etc., All Complete As Per Specification And As Directed By Engineer In Charge. Note:1) Dx Type Ahu With Condensing Unit Of Capacity 5.5 Tr X 2 Nos. Installed In The Year 2020.2) Rate Shall Be Quoted For Camc Per System Per Year. 3) 2 Systems X 2 Years = 4 Nos. , Comprehensive Maintenance Contract For Blue Star Make Dx Type Air Handling Unit Of 17Tr ( 8.5 Tr X 2 Nos. Circuit) Capacity. (Running In Good Condition). It Includes Replacement Of Defective Bearings & Belts , Cleaning Of Ac Plant Room, Supply & Return Air Grills And Diffusers, Air Filters, Evaporator And Condenser Coil, Scroll Compressor , Ac System Control Panel , All Type Of Electrical And Mechanical Items Etc., All Complete As Per Specification And As Directed By Engineer In Charge.Note: 1) Dx Type Ahu With Condensing Unit Of Capacity 8.5 Tr X 2 Nos. Installed In The Year 2025.2) Rate Shall Be Quoted For Camc Per System Per Year. 3) 2 Systems X 2 Years = 4 Nos. , Comprehensive Maintenance Contract For Bluestar Make Of 5.0 Tr (2.5 Tr X 2 Nos. Circuit) Capacity Ductable & Multi Split Air Conditioners. (Running In Good Condition). It Includes Cleaning Of Supply & Return Air Grilles, Diffusers, Air Filters, Evaporator And Condenser Coil, Lubricating Of Moving Parts, Checking Of Refrigerant Suction And Discharge Pressure, Measuring Current, Repair And Replacement Of Pc Board, Capacitor, Fan Motors, Drier, Evaporator Coil, Condenser Coil, Rotary/Reciprocating/Scroll Compressor, All Type Of Electrical And Mechanical Items, Etc, All Complete As Per Specification And As Directed By Engineer In Charge.Note: 1) Rate Shall Be Quoted For Camc Per System Per Year. 2) 5 Systems X 2 Years = 10 Nos. , Comprehensive Maintenance Contract For Bluestar Make Of 3.0 Tr Capacity Mega Split Air Conditioners. (Running In Good Condition). It Includes Cleaning Of Air Filters, Evaporator And Condenser Coil, Lubricating Of Moving Parts, Checking Of Refrigerant Suction And Discharge Pressure, Measuring Current, Repair And Replacement Of Pc Board, Capacitor, Fan Motors, Drier, Evaporator Coil, Condenser Coil, Rotary/Reciprocating/Scroll Compressor, All Type Of Electrical And Mechanical Items, Etc, All Complete As Per Specification And As Directed By Engineer In Charge.Note: 1) Rate Shall Be Quoted For Camc Per System Per Year. 2) 25 Systems X 2 Years = 50 Nos. , Comprehensive Maintenance Contract For Kitchen Ventilation System Installed In Various Location Of Kalpakkam Township ( Running In Good Condition). It Includes Cleaning Of Baffle Filters, Grilles, Replacement Of Defective Bearings, Belts And Capacitor, Fan Motor, Pc Board All Type Of Electrical And Mechanical Items, Painting Of Ducts And Fan Blowers Etc., All Complete As Per Specification And As Directed By Engineer In Charge. Note:1) Each System Have Exhaust Blower 5 Hp, Fresh Air Blower 3 Hp And Cleaning Of Baffle S.S Filters.2) Rate Shall Be Quoted For Camc Per System Per Year. 3) 3 Systems X 2 Years = 6 Nos. , Painting Of Packaged Air Conditioners Outdoor Unit Of Capacity 5.5 Tr. The Work Shall Includes Cleaning Of Said Units, Scrubbing And Spray Painting Of Sheet Metal Parts Including Interior And Exterior With One Coat Red Oxide Paint And Two Coat Of Epoxy Paint., All Complete As Per Specification And As Directed By Engineer In Charge. , Tinkering Of Packaged Air Conditioners Outdoor Unit Of Capacity 5.5 Tr., It Includes Minor Fabrication, Tinkering With White Metal Paste Etc., All Complete As Per Specification And As Directed By Engineer In Charge. , Supply, Installation And Leak Testing Of Air Cooled Anti Corrosive Coated Blue Finned Condenser Coils For Packaged Ac / Ductable Ac As Per The Specification And As Required. Air-Cooled Condenser Coil Shall Be A Compact Coil Made Using Latest Advanced Copper Tubes With Anti Corrosive/ Hydrophilic Coated Aluminium Fins As Per The Original Installed In The Above Ac Units. Copper Tubes Shall Be Bullet Expanded Into Aluminium Fins For Mechanical Bonding. Independent Sub Cooling Circuit Shall Be Provided In Each Coils To Improve Eer. Copper Tube With Aluminium Blue Finned 14-16 Fpi, Condenser Coil , Fabrication, Supply And Installation Of Double Skin Air Handling Units With Inner Skin Of 0.8Mm Plain Ss & Outer Skin Of 0.8Mm Precoated Ss Sheets With 25Mm Thick Puf Insulated Panels Density Of Not Less Than 40±2 Kg/M3 . All Ahu`S Shall Be With Thermal Break Profile Constructed With Internal Coving. Insulation Shall Be Spread Equal Across The Panel To Avoid Any Air Pocket. All Panels Shall Be Sealed Against The Framework. The Panel Shall Be Mounted Flush With The Frame Members To Create Smooth Surface Inside And Outside. (Ahu Size: 4000L X 2000W X 1000H) , Safely Dismantling Of Old Dx Type Air Handling Unit, Air Cooled Condensers, Evaporator Coils, Blower With Motor, 3 Stage Filter Assembly And Associated Ducting, D Ers And Supports, Etc., From Operation Theatre-1 Of Dae Hospital, Gso, All Complete As Per The Scope And As Directed By Engineer In Charge.
Basic Detail
Tender No GEM/2026/B/8119337
Bidding Type Tender
Location
City Chengalpattu
State Tamil Nadu
Key Dates
Publish Date 05 Oct 2026
Submission Date 22 Oct 2026
Open Date 23 Oct 2026
Finance
Tender Value 48.88 Lakhs
Tender Fee Ref. Documents
EMD 98000
Exemption Available
Document List
0afbb592-e73b-44d7-913a-c82a2a258857.pdf
1791201591.xlsx
1791201596.pdf
1791201600.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Oct 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
pdf

0afbb592-e73b-44d7-913a-c82a2a258857.pdf

xlsx

1791201591.xlsx

pdf

1791201596.pdf

pdf

1791201600.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender