Power Government Departments Closing in 20 days TDR #57872912

Tender For Creation Of New 3.15 Mva 33/11 Kv, Receiving Station At Village Chill, Dodaimportant Note : All Allied And Associated Works Required For Successful Execution Of Above Items Of Works Including Testing And Energisation , Specifically Mention

Issued by Government Departments · Doda, Jammu and Kashmir
Tender Value
Ref. Documents
Estimated cost
Bid Submission
27 Oct 2026
20 days left
EMD
6.63 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Doda → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Creation Of New 3.15 Mva 33/11 Kv, Receiving Station At Village Chill, Dodaimportant Note : All Allied And Associated Works Required For Successful Execution Of Above Items Of Works Including Testing And Energisation , Specifically Mentioned Or Not In Above Description But Required At Site Shall Be Deemed To Be Included And Covered In The Quoted Rates.

BOQ

Name of Work:- Creation of new 3.15 MVA 33/11 KV, Receiving Station at Village Chill, DodaImportant Note : All allied and associated works required for successful execution of above items of works including testing and energisation , specifically mentioned or not in above description but required at site shall be deemed to be included and covered in the quoted rates.
Sl. No. Item Description
1Please Enable Macros to View BoQ information
2Survey, Supply, Installation , Testing and Commissioning for 33 kV Line BAY at Receiving Station Chill
333kV VCB (36KV,1250 A,26.2 KA, outdoor type Make Megawin, Crompton Greaves Pascal, Stelmec ,etc .
433KV C&R Panel along with O/C, E/F and differential relays (IEC61850), mimic diagram, Voltmeter,Ammeter,Annunciation Windows with annunciation relays, 3-phase Trivectometer-5Amps DLMS Compliant with RS-485 Port
533KV Isolator with earthing blade 36KV,1250Amp, Outdoor 3-Pole 25kA
633KV Isolator without earthing blade 36KV,1250Amp, Outdoor 3-Pole 25kA
733KV Current Transformer (33KV ,1-phase, multi ratio multi core outdoor 1 no per phase)
833KV Voltage Transformer (33KV/110V,1-phase, multi core outdoor 1 no per phase)
933KV Lightening Arrestor (30 kv,10kA, Station Class,ZnO,Polymer)gap less
1033KV Polymer Post Insulator 36kv,170kv Impulse, Creepage distance 1224mm
11CONTROL CABLES
1212 Core 2.5mm2 control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab,etc. a
13ii) 4 Core 2.5mm2 control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab,etc.
14iii) 2 Core 2.5mm2 control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab,etc.
15Lugs, Ferrules etc.
16PIPE STRUCRURES
17Galvanised Steel Structures
18Galvanised Nuts & Bolts
19CONDUCTOR AND HARDWARE
20Providing & Fixing of of BusBar System with 200 sqmm A.C.S.R.Panther Conductor,including Aluminium tension/suspension fitting suitable for Panther Conductor,T Clamps/P.G.Clamps/P.I. Clamps./C.T. Clamps/Isolator Clamps/PT Clamps etc complete job (One No Line Bay)
21Providing of Lightening Protection System with Earthwire (7/4 sqmm) & allied Earthwire Tension Clamps.The Peak Tower shall be connected with independent raiser of G.I. Flat 25mm x 3 mm connected with main earth mat.
22Providing & Welding of Raisers with G.I. Flat of Size 50 mm x 6 mm.Each Equipment structure shall be provided with two raisers connected with Earthmat.The Details of Raisers shall be finalised by Engineer Incharge in detailed engineering
23Survey, Supply, Installation , Testing and Commissioning for TRANSFORMER BAY at Receiving station Chill
2433kV VCB (36KV,1250 A,26.2 KA, outdoor type Make Megawin, Crompton Greaves Pascal, Stelmec ,etc .
2533kv C&R Panel along with O/C, E/F relays , mimic diagram, Voltmeter, Ammeter, Annunciation windows with annunciation relays, 3-Phase Tri-Vector Smart meter- % amps, DLMS Compliant including earthing. Make Megawin, Crompton Greaves Pascal, Stelmec, Yamuna ,etc .
2633KV Current Transformer (CTR 250/125-5A,1- phase multi-core, outdoor,1No. Per phase) on along with fabricatioon ,laying MS Gantry includuing Civil foundation works etc as per REC standards.
2733 kV Polymer Post Insulator 36kV,170kV Impulse, creepage distance 1224m
2833KV Lightening Arrestors(33 KV 10 KA Polymer, ZnO, Gapless)
2933kv Isolator without Earthing Blade (36kv , 1250A,outdoor,3 poles, 25KA) along with fabricatioon ,laying MS Gantry includuing Civil foundation works etc as per REC standards.
3012 Core 2.5mm2 control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab, KEI etc.
314 Core 2.5mm2 control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab, KEI etc.
322 core 2.5mm2 Control Cable copper Armoured, 1.1KV Grade, ISI, FRLS of make Havells, Polycab, KEI etc.
33Galvanised Pipe/ Steel Structures
34Galvanised Nuts & Bolts
35Providing & Fixing of of BusBar System with 200 sqmm A.C.S.R.Panther Conductor,including Aluminium tension/suspension fitting suitable for Panther Conductor,T Clamps/P.G.Clamps/P.I. Clamps./C.T. Clamps/Isolator Clamps/PT Clamps etc complete job (One No Line Bay+ One No Transformer Bay)
36Providing of Lightening Protection System with Earthwire (7/4 sqmm) & allied Earthwire Tension Clamps.The Peak Tower shall be connected with independent raiser of G.I. Flat 25mm x 3 mm connected with main earth mat.
37Providing & Welding of Raisers with G.I. Flat of Size 50 mm x 6 mm.Each Equipment structure shall be provided with two raisers connected with Earthmat.The Details of Raisers shall be finalised by Engineer Incharge in detailed engineering
38SITC of POWER TRANSFORMER (3.15MVA)
3933/11kV, 3 phase ONAN, Copper wound, Out-door Type, conventional Power Transformer, Oil Filled with OLTC and all accessories including HT and LT Terminal connections (3.15 MVA) as per latest IS Standards
4012 Core 2.5mm2 control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab,etc.
416 Core 2.5mm2 control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab,etc.
422 Core 2.5mm2 control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab,etc.
43SITC of 11 kV INDOOR SWITCHGEAR OF 33/11 kV SUBSTATION
4411 kV VCB Panel Board Set (12 kV, 1250A, 25 kA, Indoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port SCADA Compatible etc MAKE :- Seimens, Megawin, Pascal, or equivalent :- including Smart meters Trivector.
4511kV, Gapless Surge Arrestor,9 KV ,10 KA ,LA with Polymer housing, Stn. Type (5Sets Station type 1 for Power Tx))
4611 kV 3- Core XLPE 185 mm² armoured, FRLS
4711 kV 3- Core XLPE 120 mm² armoured, FRLS
4811 kV Indoor Heat Shrinkable Cable Termination Kits for incoming cable
4911 kV Indoor Heat Shrinkable Cable Termination Kits for 185 sqmm single core(Indoor)
5011 kV Indoor Heat Shrinkable Cable Termination Kits for 185 sqmm single core (outdoor )
5111 kV Indoor Heat Shrinkable Cable Termination Kits for outgoing cable
5211 kV Indoor Heat Shrinkable Cable Termination Kits for 120 sq mm Cable (indoor)
5311 kV Indoor Heat Shrinkable Cable Termination Kits for 120 sq mm Cable (outdoor)
5411 kV Isolator, double break,3-pole, 600Amp, horizental mounting Type, with Earth Switch.
5511kV GO set , AB Switch 3-Phase, 3-Pole, 200 Amp
56Galvanised iron of sorts
5709 Mtr. Long Pole(ST-410 SP33)
58120 mm² PVC LT Cable 4 Core, armoured, FRLS
59Cement bottoming 1:2:4 mix as per REC standards 0.5cum per pole
60Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI strip for ST poles
61100 kVA,11/0.433KV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound)
62Earthing of 100KVA substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mm x10 mm & 50 mm x 6 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
63MCCB 200 Amp with box
64COMMON MISCELLENOUS WORKS
65HDPE Pipe Outer Dia 180 mm Inner Dia 152 mm for laying of 11kV XLPE Cable from Power Transformer to Control Room
66Providing & Laying of Earthmat by Using G.I. Flat of Size 50 mm x 8mm as grounding Conductor.The mesh Size shall 2 m x 2 m.The Burial Depth of G.I. Flat Shall be minimum 600 mm.The work involves the excavation of trenches for burial of grounding flat,Laying of G.I.Flat including welding & Backfilling of Trenches
67Earthing Electrode ( 3m long 40mm dia GI pipe) through GI Strip.
68Supply, Errection, Testing & commisioning of Battery Bank 32v 100AH of 15+1 No. cells of 2V each, sealed maintenance free VRLA type, Hgh Impact Polyprophelene copolymer container flame retardant of make Exide Amaron or Tata etc.
69Supply, Errection, Testing & commisioning of Float-Cum-boost Charger with full wave rectification for 220v, 1 Phase 50HZ AC input supply suitable for charging of Battery Bank 32V, 100AH of 15+1 No. cells of 2V each, sealed maintenance free VRLA type, Hgh Impact Polyprophelene copolymer container flame retardant.
70Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Double busbar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories
71Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCB's (16-125 Amps ) and 5 No DP MCBs (0-32A),Rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories
72Civil /Misc Works
73Lump sum amount for PHE WATER connection
74(Development of land) Earthfilling/Cutting upto desired FGL (As decieded by Engineer incharge during detailed Engineering)by Way of Removing Weeds,Wild Grass and endulation if any including disposal of surplus material
75Compound walling of identified land by way of Mass Concrete in Foundations and 228 mm Brick Wall of 2 M height
76Providing and laying cement concrete in retaining walls/Drains 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
77Chainlink Fencing of 33 kV Yard of Substation by way of Mass Concrete in Foundations and chainlink fencing of 6 ft height
78Providing & Fixing of double frame Gate(Min 4000 mm wide & 2000 m high) with 50 dia G.I.Tube in outer frame & 10mm/20 mm Sq rods welded to tubular frame (Final Design to be approved by Engineer incharge).There shall be provision of drop Bolts of 16 mm dia M.S. Rod & suitable Concrete Pockets for holding Bolts.Wheels at bottom & flat arrangement for smooth opening & closing shall be provided
79Construction of R.C.C. Pillars for holding of gate including cost of material & labour.(Design of Reinforcement & sizing shall be finalised by Enginer incharge
80RCC Cable trench (1:2:4) including excavation and disposal of un-wanted soil. for laying of 11 KV XLPE Power Cable and control cable from power transformer, VCB and other equipments to control room and for outgoing cables from control room to outgoing structures including cable duct covers (cable duct covers should be covered with Angle Frames using angle 45x45x5 mm and 8 mm Tar Steel @ 200 c/c & M-20 Concrete)
81BUILDING: A. Control Room Buildingon ground floor complete with Column and Beam structures with 1 no J.E. Room , 1 Store room, 1 Battery Room and a main hall including aluminium windows, cable ducts for power and control cable, Toilet (complete with WC, Washbasin and fittings), electric fittings(fans, LED tubelights, leds powerpoints and other fixtures)White Washing of entire building , painting of doors and windows etc. Overhead /undergroung water Storage tanks . 2 nos of office tables and 6 nos of chairs , staircase . Water Supply . Septic Tank complete with Sanitary Fittings including kota stone floor .complete in all respects
82Construction OF SBA quarters over control room building with specifications and drawings approved by the Engineer incharge.
83construction of septic tank 8x8x6 feet with brick walls and RCC Slab
84construction of water storage tank 8x8x6 with brick walls and RCC Slab
85Truss for control room Building 1.3xPlinth area (Providing and fixing of steel truss including provision of colour coated Roofing.
8633/11 kV Power Transformer Foundation as per REC standards
87Auxillary Transformer Foundation as per REC standards
8833 kV Equipment Foundation & Gantry foundation as per REC standards
8933 KV Yard Concreting with 1: 4 :8 with 20 mm nominal stone aggregate 4 inch thick & RCC 1 :2 :4 with 20 mm nominal stone aggregate 4 \\" thick.
9033 kV Yard Lighting with 6 nos 9 mtr ST poles each having 2 x 100 Wt LEDs street lights of reputed brand complete with earthing , cement bottoming GI brackets,cable etc . All the lights should be controlled from the control room with installation of control panel and having separate SPN for each light
91Safety Tool kit
92Crimping Tool Kit complete set for cable of different sizes upto 630 sqmm
93Rubber Mats( 2 mtr x 2 mtr x 25 mm)
94Conventional Earthing -GI Plate Earthing with 600mm X 600 mm X 6 mm, GI Plate, GI Flat 50 x 6 mm, GI Pipe, 40 mm Dia with Charcoal salt & good earth 10 ft deep pit etc. as per REC standards . Complete job
9533 KV Hand Gloves(set of 2)
9611 KV Hand Gloves(set of 2)
97RainCoats
98Safety Belt
99Gum boots
100Safety Helmet for electrician
101Digital Meggar 5000 mega Ohm
102Earth Resistance Tester
103Emergency light/ Torch 5 Watt chargeable
104Multimeter
10533KV high voltage live phase detector
106Extendable Aluminium Ladder 25 feet
107Aluminium Bus Bar 75 x 10 mm
108GI Flat 50 x 6 mm and 20 x 5 mm for risers and earthing of cable trenches and yard fencing.
109Earthing Rod (set of 3)
110Survey, Supply, Installation , Testing and Commissioning of improvement of existing 33 KV Batote-Assar by way of shifting of LINE from Chattar Pahari to Road side and Diversion of already laid 33KV Chill line upto the site of Proposed Receiving station Chill
111Supply, Transportation, Erection of 11 Mtr Long ST Poles (ST410-SP56) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
112Supply, Transportation, Erection of 13 Mtr Long ST Poles (ST410-SP69) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
113GI Channel iron X-arm of different sizes including clamps,Ties and braces for multi pole structures
11433kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
11533kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm (alongwith Dog fitting)
116100 mm2 ACSR Conductor
117Galvinized Nuts and Bolts
118Danger Plates with Clamps
119Anti-Climbing Device with Clamps
120Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5mtr long through GI Strip.
121Painting of Poles with Red Oxide and aluminium paint (min 2 coats each)
122Cement bottoming 1:2:4 mix as per REC standards .6cum/pole (to be done during erection of poles) including 5 No existing Poles
123Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete
124Creation of Isolation points along the line by way of 33 KV Isolators without earthing blades on ST 11 Mtr Poles and MS Steel etc. Complete job.
125Survey, Supply, Installation , Testing and Commissioning for ERECTION OF 11 kV LINE ON 9 METER ST POLES (9 ckt KM approx)
126Supply, Transportation, Erection of 9 Mtr Long ST Poles (ST410-SP33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
127Supply, Transportation, Erection of 11 Mtr Long ST Poles (ST410-SP56) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
128GI Channel iron X-arm of different sizes including clamps,Ties and braces
129GI Channel iron V cross-arm including clamps
13011kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
13111V Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
132PG clamps for 50 mm2 ACSR Conductor
133Galvinized Nuts and Bolts
134Danger Plates with Clamps
135Anti-Climbing Device with Clamps
136Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5mtr long through GI Strip.
137Painting of Poles with Red Oxide and aluminium paint (min 2 coats each)
138Cement bottoming 1:2:4 mix as per REC standards .45cum/pole (to be done during erection of poles)
139Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
14050 mm2 ACSR conductor
141Guard netting
142Creation of Isolation points with two number ST poles 9 m,600ampere 11KV isolater and all necessary steel as required.
143Write back of material to divisional store
144Old 9m Railpole/9m ST poles (10+6)
145Old ACSR Dog conductor Compatibility Report for DhunaBOQ.xls Run on 10-07-2021 14:05 The following features in this workbook are not supported by earlier versions of Excel. These features may be lost or degraded when you save this workbook in an earlier file format. Significant loss of functionality # of occurrences This workbook contains data in cells outside of the row and column limit of the selected file format. Data beyond 256 (IV) columns by 65,536 rows will not be saved. Formula references to data in this region will return a #REF! error. 6.0 'BoQ1'!L40 'BoQ1'!F40 Any effects on this object will be removed. Any text that overflows the boundaries of this graphic will appear clipped. 3.0 'BoQ1'!A1:II42 Minor loss of fidelity Some formulas in this workbook are linked to other workbooks that are closed. When these formulas are recalculated in earlier versions of Excel without opening the linked workbooks, characters beyond the 255-character limit cannot be returned. 5Defined Names Some cells or styles in this workbook contain formatting that is not supported by the selected file format. These formats will be converted to the closest format available. 14.0

AI Tender Summary

OUR REF NO 57872912
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 27-10-2026
Authority
Authority Name Power Development Department
Work Description Tender for Creation Of New 3.15 Mva 33/11 Kv, Receiving Station At Village Chill, Dodaimportant Note : All Allied And Associated Works Required For Successful Execution Of Above Items Of Works Including Testing And Energisation , Specifically Mentioned Or Not In Above Description But Required At Site Shall Be Deemed To Be Included And Covered In The Quoted Rates.
Basic Detail
Tender No 27 of 2026-27
Bidding Type Tender
Location
City Doda
State Jammu and Kashmir
Key Dates
Publish Date 05 Oct 2026
Submission Date 27 Oct 2026
Open Date 28 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee 5000
EMD 6.63 Lakhs
Exemption Not Available
Document List
1311f228-dc04-4250-b692-ae0d9fba42a9.html
BOQ_1106697.xls
SBDCHILL.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Oct 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

1311f228-dc04-4250-b692-ae0d9fba42a9.html

xls

BOQ_1106697.xls

pdf

SBDCHILL.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail