Housing Urban and Rular Development Government Departments Closing in 5 days TDR #57872607

Tender For Relaying Of Drinking Water Supply Line By Shifting In A New Alinement At Krishnatali(Nh-08) To Harijoy Via Brajanagar Pwd Road (Bankumari) To Uttar Majlishpur Panchyat Road During The Year 2026-27.Sh:- Upvc Line, Re-Connection Of Domstic L

Issued by Government Departments · tripura, Tripura
Tender Value
9.66 Lakhs
Estimated cost
Bid Submission
13 Oct 2026
5 days left
EMD
19339
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
tripura → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Relaying Of Drinking Water Supply Line By Shifting In A New Alinement At Krishnatali(Nh-08) To Harijoy Via Brajanagar Pwd Road (Bankumari) To Uttar Majlishpur Panchyat Road During The Year 2026-27.Sh:- Upvc Line, Re-Connection Of Domstic Line Shifting & Placing Of Sluice Valve, Jet Boring Etc. & Other Allied Works Complete.

BOQ

Name of Work:- Relaying of drinking water supply line by shifting in a new alinement at Krishnatali(NH-08) to Harijoy Via Brajanagar PWD road (Bankumari) to Uttar Majlishpur Panchyat road during the year 2026-27.SH:- UPVC line, re-connection of domstic line shifting & placing of sluice valve, jet boring etc. & other allied works complete.
Sl. No. Item Description
1Excavating trenches of required width for pipes, cables etc. including exacavation for sockets, dressing of sides where required, ramming of bottoms, depth upto 1500 mm (slope-1 in 200)including getting out the excavated soil and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil with all required leads as per Chapter - 2 of CPWD specification and direction of the Engineer - in - charge. A) For UPVC pipes in new work.a. All kind of Soils
2i) For pipes not exceeding 90 mm dia
3ii) For pipes exceeding 90mm dia but not exceeding 300mm dia.
4Providing, fixing and laying rigid UPVC pipes conforming to IS : 4985 jointing with couplers, of same class conforming to IS : 10124 ( Pt-II ) with solvent cement conforming to IS : 14182 including testing of joints complete ( but excluding the cost of specials like bend, tees etc. which will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge. A. Class - 3 ( working pressure 6.0 kg / cm2)
5i) 90 mm OD
6ii) 110 mm OD
7iii)140 mm OD
8Providing, fixing and laying fabricated UPVC bend of required degree conforming to IS : 10124 ( part 8 / 9 / 10 / 11 / 12 / 13 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
9i) 90 mm dia
10ii) 110 mm dia
11iii) 140 mm dia
12Providing, fixing and laying fabricated UPVC end cap conforming to IS : 10124 ( Part 4 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
13i) 90 mm OD
14Providing, fixing and laying fabricated UPVC equal tee conforming to IS : 10124 ( Part 5 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
15i) 90 x 90 mm dia
16ii)110 x110 mm dia
17iii) 140 x 140 mm dia
18Providing, fixing and laying fabricated UPVC straight reducer conforming to IS : 10124 ( Part 3 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
19i) 110 x 90 mm dia
20ii) 140 X 110 mm dia
21Providing, fixing and laying flanged fabricated UPVC tailpiece with MS flange ( 8 mm thick ) conforming to IS : 10124 ( Part6 ) with solvent cement conforming to IS : 14182 including testing of joints complete as er CPWD specification anddirection of the Engineer - in - charge
22i) 90 mm dia
23ii) 110 mm dia
24Providing and fixing G.I. pipes medim class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in - charge.A. External work.
25i. 15 mm dia. nominal bore
26Providing and fixing brass ferrule with C.I. cover conforming to IS : 2692 including boring and tapping the main as per CPWD specification and direction of the Engineer - in - charge.
27i) 10 mm nominal bore
28Providing and fixing C.I. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge.
29i) 80 mm dia. A. PN - 1.0
30ii) 100 mm dia. A. PN - 1.0
31Providing and fixing G.I. Nipple of medium class as per CPWD specification and direction of the Engineer - in - charge.
32i) 15 mm dia 150 mm long
33Providing and fixing U.P.V.C. service saddle as per CPWD specification and direction of the Engineer - in - charge.
34i) 90 mm dia with 15 mm dia opening
35ii) 110 mm dia with 15 mm dia opening
36Providing and laying of flexible PVC pipe (conforming to IS:7634) complete including earth work as per specification and direction of the Engineer - in - charge (cost of fittings will be paid separately).
37i) 15 mm dia
38Providing and fixing G.I. Bend /elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
391) 15 mm dia
40Providing and fixing G.I. socket as per CPWD specification and direction of the Engineer - in - charge.
41i) 15 mm dia
42Providing and fixing G.I. union as per CPWD specification and direction of the Engineer - in - charge.
43i) 15 mm dia
44Making road crossing by horizontal boaring for smooth laying of UPVC/CI/DI/GI pipes etc. of required dia complete as per specification and the direction of the Engineer-in-charge.
45A. By manual means
46Providing and fitting fixing PVC / plastic bib cock conforming to IS : 9763 in hydrant points at different location as per specification & direction of the Engineer-in-charge.
47(i) 15 mm dia PVC /plastic bib cock
48Providing, fixing and laying fabricated UPVC socket / coupler conforming to IS : 10124 ( Part 2 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
49i) 90 mm dia
50ii) 110 mm dia
51iii) 140 mm dia Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57872607
AUTHORITY Government Departments
TENDER VALUE 9.66 Lakhs
LAST DATE 13-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Relaying Of Drinking Water Supply Line By Shifting In A New Alinement At Krishnatali(Nh-08) To Harijoy Via Brajanagar Pwd Road (Bankumari) To Uttar Majlishpur Panchyat Road During The Year 2026-27.Sh:- Upvc Line, Re-Connection Of Domstic Line Shifting & Placing Of Sluice Valve, Jet Boring Etc. & Other Allied Works Complete.
Basic Detail
Tender No 49/DNIeT/EE/DWS/JRN/2026-27
Bidding Type Tender
Location
City tripura
State Tripura
Key Dates
Publish Date 05 Oct 2026
Submission Date 13 Oct 2026
Open Date 13 Oct 2026
Finance
Tender Value 9.66 Lakhs
Tender Fee 1000
EMD 19339
Exemption Not Available
Document List
55fa2105-7649-42c3-850a-6256340767d2.html
BOQ_78639.xls
SBD49.PDF
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Oct 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

55fa2105-7649-42c3-850a-6256340767d2.html

xls

BOQ_78639.xls

PDF

SBD49.PDF

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders