Tender For Electro-Mechanical Works Of 3X4 Mw Tankul Shp Including Detailed Design, Engineering, Manufacture, Supply, Erection, Testing, Commissioning And Other Associated Different Works On Epc (Engineering, Procurement & Construction) Turnkey Basis
Tender Overview
Project Description
Tender for Electro-Mechanical Works Of 3X4 Mw Tankul Shp Including Detailed Design, Engineering, Manufacture, Supply, Erection, Testing, Commissioning And Other Associated Different Works On Epc (Engineering, Procurement & Construction) Turnkey Basis Against E-
BOQ
| Sl. No. | Item Description |
| 1 | Turbine & Accessories(Details as per Chapter 1 of Section IX- (PTS)) |
| 2 | Supply of Horizontal Pelton Turbine of 1000 rpm, 624.16 m head and 4000 KW at Gen Terminals at rated parameters and inherent continuous overload capacity of 10%, complete with Turbine auxiliaries, & other accessories(Details as per Chapter 1 of Section IX- (PTS)) |
| 3 | Design approval of Turbine |
| 4 | Supply of Runner (Details as per Chapter I of Section IX- (PTS)) |
| 5 | Supply of Governor(Details as per Chapter I of Section IX- (PTS)) |
| 6 | Tools and instruments for turbine |
| 7 | Transportation and Insurance |
| 8 | Installation and Other Services (Details as per Chapter IX of Section IX- (PTS) and Chapter 1 of Section IX- (PTS)) |
| 9 | Generator & Accessories(Details as per Chapter 2 of Section IX- (PTS)) |
| 10 | Supply of Horizontal Synchronous Generator 4706KVA ,0.85 p.f.,6.6 KV generating voltage and 1000 rpm with inherent continuous overload capacity of 10 %, complete with Frame, punchings, windings, Rotor complete, Excitation system & AVR etc.(Details as per Chapter 2 of Section IX- (PTS)) |
| 11 | Design approval of generator |
| 12 | Supply of Generator neutral grounding cubicle (Details as per Chapter 2. clause 2.20 of Section IX- (PTS)) |
| 13 | Supply of LAVT panel consisting of LA, PT’s,CT's etc.(Details as per Chapter 2. clause 2.21 of Section IX- (PTS)) |
| 14 | Supply of Tools and instruments (Details as per Chapter 2, Clause no 2.23 of Section IX- (PTS)) |
| 15 | Transportation and Insurance |
| 16 | Installation and Other Services as per specifications and scope defined in Chapter IX of Section IX- (PTS) |
| 17 | Step-up Transformers(Details as per Chapter III of Section IX- (PTS)) |
| 18 | Supply of Transformer,5.5 MVA, 6.6 kV/33 KV, 50 Hz with NCT (Details as per Chapter 3 of Section IX- (PTS)) |
| 19 | Transportation and Insurance |
| 20 | Installation and Other Services as per specifications and scope defined in Chapter III of Section IX- (PTS) |
| 21 | Protection, Metering System & SCADA System(Details as per Chapter IV of Section IX- (PTS)) |
| 22 | Generator / turbine control, protection, instrumentation & annunciation panel & synchronisation panel |
| 23 | SCADA and Automation System as per Specification |
| 24 | Transportation and Insurance |
| 25 | Installation and Other Services as per specifications and scope defined in Chapter IV of Section IX- (PTS) |
| 26 | Electrical Auxiliaries(Details as per Chapter V of Section IX- (PTS)) |
| 27 | Supply of Auxiliary Transformers 250KVA, 33KV/ 433V, 50 Hz, ONAN(Details as per Chapter 5, clause 5.1 of Section IX- (PTS)) |
| 28 | LT Board, 415 V with incoming LT breaker and outgoing MCCB’s |
| 29 | Supply of 110 V ,400 AH battery, battery charger and DC distribution board(Details as per Chapter 5, clause 5.2 of Section IX- (PTS)) |
| 30 | LT Switchgear (AC and DC) (Details as per Chapter 5, clause 5.3 of Section IX- (PTS)) |
| 31 | Supply 160 KVA DG Set Diesel Generator (DG) Set(Details as per Chapter 5, clause 5.4 of Section IX- (PTS)) |
| 32 | supply of 6.6 kV grade, 1100 V grade, 600 V grade, AC/ DC Power and Control cables, cable supports, trays, lugs/ thimbles, cable numbering ferules etc., along with chequered plates for cable(Details as per Chapter 5, clause 5.5 of Section IX- (PTS)) |
| 33 | Powerhouse, switchyard lighting (Details as per Chapter 5, clause 5.6 of Section IX- (PTS)) |
| 34 | Lightning Protection System(Details as per Chapter 5, clause 5.7 of Section IX- (PTS)) |
| 35 | Internal Communication System(Details as per Chapter 5, clause 5.8 of Section IX- (PTS)) |
| 36 | Emergency Lighting (DC) System(Details as per Chapter 5, clause 5.9 of Section IX- (PTS)) |
| 37 | Supply of Transformer Oil Purification System (Details as per Chapter 5, clause 5.10 of Section IX- (PTS)) |
| 38 | Earthing system for powerhouse, upstream and switchyard equipment(Details as per Chapter 5, clause 5.11 of Section IX- (PTS)) |
| 39 | Transportation and Insurance |
| 40 | Installation and Other Services as per specifications and scope defined in Chapter V of Section IX- (PTS) |
| 41 | Mechanical Auxiliaries(Details as per Chapter VI of Section IX- (PTS)) |
| 42 | Pendant operated EOT of 25/5T capacity (Details as per Chapter 6, Clause no 6.1 of Section IX- (PTS)) |
| 43 | Drainage System (Details as per Chapter 6, Clause no 6.2 of Section IX- (PTS)) |
| 44 | Cooling-Water System(Details as per Chapter 6, Clause no 6.3 of Section IX- (PTS)) |
| 45 | High-Pressure and Low-Pressure Compressed Air System(Details as per Chapter 6, Clause no 6.4 of Section IX- (PTS)) |
| 46 | Water-Level Measuring and Transmitting System(Details as per Chapter 6, Clause no 6.5 of Section IX- (PTS)) |
| 47 | supply 650 litres oil filtration m/c along with accessories, trolley etc.(Details as per Chapter 6, Clause no 6.6 of Section IX- (PTS)) |
| 48 | Ventilation and Air conditioning system (Details as per Chapter 6, Clause no 6.7 of Section IX- (PTS)) |
| 49 | Supply of Main inlet Spherical Valve of 450 mm nominal dia and design pressure; complete in all respect (Details as per Chapter 6, Clause no 6.8 of Section IX- (PTS)) |
| 50 | Supply of PPV Butterfly Valve 850 mm Dia(Details as per Chapter 6, Clause no 6.9 of Section IX- (PTS)) |
| 51 | Transportation and Insurance |
| 52 | Installation and Other Services as per specifications and scope defined in Chapter IX of Section IX- (PTS) |
| 53 | Details of 33 KV outdoor Switchyard(Details as per Chapter VII of Section IX- (PTS)) |
| 54 | Line protection and metering panel with TVM |
| 55 | 33KV, 800A, 40 kA SC breaking current capacity Vacuum Circuit Breaker |
| 56 | 33 KV, 400/1A or 120/1 A outdoor type Multi Core Current Transformers |
| 57 | 33 KV/ 110V, 100 VA/ 100 VA, Star/Star/Star Potential Transformers |
| 58 | 33 KV, 800A triple pole, double break Isolator with bimetallic terminal connector, junction box etc. |
| 59 | 33 KV, 800A triple pole, double break Isolator with earth switch bimetallic terminal connector, junction box etc |
| 60 | 30kV,10 kA lighting arrestors, with insulators base and surge counter (single phase) |
| 61 | Switchyard structures viz towers, poles, other foundations etc., |
| 62 | Clamps, connectors for equipments termination, suspension/ Tension insulators |
| 63 | Transportation and Insurance |
| 64 | Miscellaneous |
| 65 | Installation and Other Services as per specifications and scope defined in Chapter VII of Section IX- (PTS) |
| 66 | Fire Extinguishing, HVAC equipment |
| 67 | Fire Extinguishing, HVAC equipment |
| 68 | Transportation and Insurance |
| 69 | Installation and Other Services as per specifications and scope defined in Chapter IX of Section IX- (PTS) |
| 70 | Supply of Spares (Details as per Chapter VIII of Section IX- (PTS)) |
| 71 | CFD analysis of machine Report Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender