Banking and Finance Government Departments Closing in 15 days TDR #57872233

Tender For Electrical Renovation Works Of Hrmd At 3Rd Floor Of Banks Main Office Building, Reserve Bank Of India, Bengaluru

Issued by Government Departments · Bengaluru Urban, Karnataka
Tender Value
9.50 Lakhs
Estimated cost
Bid Submission
24 Oct 2026
15 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Electrical Renovation Works Of Hrmd At 3Rd Floor Of Banks Main Office Building, Reserve Bank Of India, Bengaluru

BOQ

Name of Work:- Electrical Renovation works of HRMD at 3rd floor of Banks Main Office Building, Reserve Bank of India, Bengaluru
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 3x 1.5 sq.mm FRLS PVC insulated copper wire in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box etc. as required. Average length is 8 meters.
2Wiring for light point/ fan point/ exhaust fan point with 3 x 1.5 sq.mm FRLS PVC insulated copper wire in surface / recessed medium class PVC conduit, and connected to the existing MCB in the lighting DB. as required. Average length is 10 meters.
3Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 3 x 1.5 sq.mm FRLS PVC insulated copper wire in surface/ recessed PVC conduit etc. as required. Average length is 4 meters.
4Wiring for circuit/ submain wiring with 2 x 2.5 sq.mm + 1 x 1.5 sq.mm earth wire with the following sizes of FRLS PVC insulated copper conductor, single core wire in surface/ recessed medium class PVC conduit as required. Length of wire only considered for measurement purpose.
5Wiring for circuit/ submain wiring with 2 x 4 sq.mm + 1 x 2.5 sq.mm earth wire with the following sizes of FRLS PVC insulated copper conductor, single core wire in surface/ recessed medium class PVC conduit as required. Length of wire only considered for measurement purpose.
6Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall/ground and making good the same in case of recessed conduit as required.
720 mm
825 mm
932 mm
10Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
11Supplying and fixing suitable size GI/PVC box with modular plate and cover on surface/work station or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. Location of switch and socket may be different for wall fans, digital clocks, TV etc.
12Supplying and fixing suitable size GI/PVC box with modular plate and cover on surface/work station or in recess, including providing and fixing 2 Nos. of 3 pin 5/6 A modular socket outlet and 2 Nos. of 5/6 A modular switch, connections etc. as required.
13Supplying and fixing suitable size GI/PVC box with modular plate and cover on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. Location of switch and socket may be different for AC point.
14Supplying and fixing factory fabricated, powder coated (Black/Grey) four module cable cubby/Pop up box on the work station in recess manner, including providing and fixing 1 No. of 3 pin 5/6 A modular socket outlet (black colour), 1 Nos. of 5/6 A modular switch (black colour) and 1 No. of USB port with all connections etc. as required.
15Supply & Providing wiring for telephone point by providing 2 Module box concealed in wall/ work station with cover and wiring with two pair 0.5 mm. dia copper conductor PVC insulated in surface/ recessed suitable dia PVC Medium duty conduit. The rate shall include for providing modular Telephone sockets with respective make, required size mounting plate fixed on M.S. box concealed in wall/work station, termination of the wire at both ends. Average length of wiring is 15-20 meters (krone box will be provided and the cables are to be terminated on the same). Ferrules shall be provided at both ends.
16Supply, installation, testing & commissioning of Krone type tag block with100 Pair krone modules to be fixed on wall in concealed manner in suitable size waterproof M.S. (16SWG) of 200 pair box duly painted with powder coating paint with hinged cover box having locking arrangement, using all accessories necessary for completing the work.
17Installation, testing and commissioning of occupancy sensor, LED downlight (Up to 36 Watts) including LED driver on false ceiling/ in surface manner, including connection. Light fittings and accessories will be supplied by the Bank
18Installation, testing and commissioning of LED linear lights/ hanging lights / Pendant lights in false ceiling/ in surface manner, including connection with anchor fastener. Light fittings will be supplied by the Bank
19Supply, installation, testing and commissioning of 6-way 3 phase (TPN) MCB DB double door factory fabricated, IP 43 protection in concealed/ partially concealed manner complete with termination of cable with gland and lugs, loop connections, earthing etc. Sufficient blanking plates to be provided. along with the following breakers. 1. Supply, fixing, interconnection and commissioning of 4 pole RCCB 40 A, 100mA-1No. 2. Supply, fixing, interconnection and commissioning of 4 pole MCB 40 A (C-curve)-1No. 3. Supply, fixing, interconnection and commissioning of 1 pole MCB 16/10 A (C-curve)- 18 Nos.
20Supply, laying and termination (using copper lugs and brass glands) of 4C X 10 Sq.mm Cu Cable with 2 runs of 12 Gauge bare copper 1.1kV grade XLPE insulated PVC sheathed, armored copper conductor power cable amended up to date.
21Ceiling Mounted Speaker - Supply, fixing, testing and commissioning of ceiling mount Metal Grille Speakers with inbuilt line matching transformer with power 6W with all accessories required for complete installation as required.
22Wall Mounted Speaker - Supply, fixing, testing and commissioning of wall mount Speakers with inbuilt line matching transformer with power 6W with box all accessories required for complete installation as required.
23Supply and laying and clamping of 2Cx1.5 Sq.mm flexible speaker cable in medium duty conduit / cable tray /wall using factory made heavy gauge GI/painted MS clamps.
24Removing charges of existing DBs, fans, switchboards, wiring and conduits, light fittings, sensors, etc., and handing over to Bank Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57872233
AUTHORITY Government Departments
TENDER VALUE 9.50 Lakhs
LAST DATE 24-10-2026
Authority
Authority Name Reserve Bank Of India
Work Description Tender for Electrical Renovation Works Of Hrmd At 3Rd Floor Of Banks Main Office Building, Reserve Bank Of India, Bengaluru
Basic Detail
Tender No RBI/Banaglore Regional Office/25/26-27/ET/014
Bidding Type Tender
Location
City Bengaluru Urban
State Karnataka
Key Dates
Publish Date 05 Oct 2026
Submission Date 24 Oct 2026
Open Date 26 Oct 2026
Finance
Tender Value 9.50 Lakhs
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
BOQ_341986.xls
e6d7ca65-ee53-43a9-9203-98714961135a.html
TenderDocument.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Oct 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_341986.xls

html

e6d7ca65-ee53-43a9-9203-98714961135a.html

pdf

TenderDocument.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders