Defence Statutory Bodies & Commissions/Committees Closing in 4 days TDR #57870873

Tender For Special Rep Of Bldg No P-461(Kote & Qtr Gd) Of Certain Units In Jamnagar Mil Stn Under Ge(A) Jamnagar.

Issued by Statutory Bodies & Commissions/Committees · Jamnagar, Gujarat
Tender Value
Ref. Documents
Estimated cost
Bid Submission
03 Nov 2026
4 days left
EMD
97000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jamnagar → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Rep Of Bldg No P-461(Kote & Qtr Gd) Of Certain Units In Jamnagar Mil Stn Under Ge(A) Jamnagar.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 13-Oct-2026 AMENDMENT TO BOQ BOQ 27-Oct-2026
2 27-Oct-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-Nov-2026

BOQ

Name of Work:- SPL REP OF BLDG NO P-461(KOTE & QTR GD) OF CERTAIN UNITS IN JAMNAGAR MIL STN UNDER GE(A) JAMNAGAR.
Sl. No. Item Description
1Dismantaling floor, hearth or wall tiling including cement mortar bedding(but not backing) removing servicable tiles to store and rubbish off premises complete all as specified and directed.
2Taking down chowkats with shutter (without taking off shutters from the frames) exc 1.5 sqm but n exc 4 sm each, complete all as specified and directed.
3Taking down shutter of any description exc 1sqm each and n exc 2Sqm each, complete all as specified and directed.
4Taking down PVC Chowkats or Frames, not exc. 1.50 Sqm Each with Shutters (without taking off shutters from frames), complete all as specified and as directed.
5Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed.
6Demolition Cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level complete all as specified and directed.
7Demolition of brick work or stone/boulder masonary built in CM including all quoins, arches, pillars, etc but excluding ashlar, facing, dressed stone work and pre-cast concrete articles complete all as specified and as directed by Engineer-in-Charge
8Taking down cement plaster on brick or concrete surfaces including racking out joints hacking for keys scrubbing down with water etc complete all as specified and directed.
9M&L for rendering 10mm thick on fair faces on brick masonary/stone masonary or concrete surfaces in cm 1:6 finished fair and even complete all as specified and directed.
10M&L for Prepration of newly plastered on walls by hand held sander / long handle sander including cornices, pilasters etc complete all as specified directed and applying two coat of oil bound distemper over one coat of acrylic water based interior grade primer @ 0.7 ltr(undiluted )/10sqm diluted with water in 1:1 ratio (Minmum ) or as per approved manufacturers instructions to be applied on prepared and wall (interior) surface, over a coat 1 mm thick wall care waterproof cement based putty on walls complete as specified Notes:-(i)Filling cracks in wall using crack seal compound Asian smart crack seal or equivalent.Notes:- (ii) make -BergerHomeshield waterproof putty ,Asain paint smartcare waterproof putty , Nerolac prema waterproof putty ,Berger Homeshield waterprrof putty ,(iii) Approved OEM equipment to be used as per technical & site requirement and as mentioned above.
11M&L for Prepration by hand held sander / long handle sander including cornices, pilasters etc of newly plastered on wall complete all as specified directed and applying three coat of white wash complete all as specified and directed.
12M&L 15 mm thick rendering on other than fair faces of external wall of brick masonary/stone masonary or concret surfaces in two layers Ist layer shall be 10mm in cm 1:6, secound and final layer shall be 5mm thick in CM 1:4 finished fair and even without using extra cement mixed with integral water proofing compound complete all as specified and directed.
13M&L Prepration of newly plastered surface of wall by hand held sander / long handle sander including cornices, pilasters etc and appliying with Airless spray two or more coats of Anti fungal Weather proof grade exterior acrylic emulsion paint @ 0.2 lt (undiluted) /10 sq mtrs diluted with water in 1:1 ratio (Minimum) of approved tint as per approved manufacturers insttruction over prepared and primed surface of external wall over and including one coat of acrylic water based Exterior grade rpimer @0.9 ltr (undiluted)/10 sq mttr diluted with water in 1:1 ratio (minium) as per approved manufacturer's instructions to be applied on prerated and wall (external) surfaces. complete all as specified and directed.
14M&L 5 mm thick rendering on ceiling or concrete surfaces in cm 1:3 finished fair and even complete all as specified and directed.
15M&L for Prepration by hand held sander / long handle sander including cornices, pilasters etc of newly plastered on ceiling complete all as specified directed and applying three coat of white wash complete all as specified and directed.
16M&L complete removal of existing tretment by hand held sander / long handle sander washing down with Jet washer and appliying Airless spray two or more coats of Anti fungal Weather proof grade exterior acrylic emulsion paint @ 0.2 lt (undiluted) /10 sq mtrs diluted with water in 1:1 ratio (Minimum) of approved tint as per approved manufacturers insttruction over prepared and primed surface of external wall over and including one coat of acrylic water based Exterior grade rpimer @0.9 ltr (undiluted)/10 sq mttr diluted with water in 1:1 ratio (minium) as per approved manufacturer's instructions to be applied on prerated and wall (external) surfaces. complete all as specified and directed.
17Complete removal of existing treatment of old surfaces of wall including preparation of surfaces by hand held sander / long handle sander including cornices, pilasters etc and applying two coats of oil bound distemper over one coat of acrylic water based interior grade primer @ 0.7 ltr (undiluted) /10sqm diluted with water in 1:1 ratio (Minmum ) or as per approved manufacturers instructions to be applied on prepared and wall (interior) surface, over a coat 1 mm thick wall care waterproof cement based putty on walls complete as specified Notes:-(i)Filling cracks in wall using crack seal compound Asian smart crack seal or equivalent.Notes:- (ii) make -BergerHomeshield waterproof putty ,Asain paint smartcare waterproof putty , Nerolac prema waterproof putty ,Berger Homeshield waterprrof putty ,(iii) Approved OEM equipment to be used as per technical & site requirement and as mentioned above.
18M&L Preparation of old surfaces of wall removing nails including scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc by hand held sander / long handle sander including cornices, pilasters etc (Plastered or unplastered surfaces) , filling undulation and holes with putty and applying one coat of oil bound distemper with roller finish complete all as directed on walls etc.complete as specified and as directed by Engineer-In-Charge.
19Preparation of old plastered surfaces of ceiling by hand held sander / long handle sander including cornices, pilasters etc and applying one coat of white wash complete all as specified and directed.
20Preparation of old plastered surfaces of wall surface by hand held sander / long handle sander including cornices, pilasters etc and applying one coat of white wash complete all as specified and directed.
21Complete removal of existing roof treatment, removing rubbish off the premises, cleanning the surface and preparing to receive new roof treatment and applying roof treatment as under:- (a) Applying coat of bituminios primer @ 0.40 litre/ Sqm on prepared surfaces and allow to dry(the primer and the membrane to be used shal be of same manufacturer, (b) Supply and laying of minimum 3 mm thick APP modified polymeric membrane weighting not less than 3 KG/ Sqm black finish reinforcement with non woven polyster matt with help of torching with proplane or abutance gas using torch with minimum 75 mm side overlap and 100 mm end overlap. (c) all overlaps and joints shall be sealed as per manufacturers instruction complete all as specified and directed.note : wpc shall be measured and paid sepearately.
22Roughening surfaces of old concrete surfaces by picking, sweeping clean and washing down with water to remove dust, etc incl brushing neat cement slurry with 3.0 kg of cement per sq metre complete all as specified and directed.
23M&L for Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed.
24M&L for Rendering 10mm thick in CM(1:3) with using water proofing compound on fair faces of brick work/ Fasia and roof surface finished even and smooth without using extra cement complete all as specified and directed.
25M&L PCC 1:2:4, type B0 (using 12.5mm size stone aggregate) as levelling course complete all as specified and directed.
26M&L 40 mm thick PCC 1:2:4, type B0 (using 12.5mm size stone aggregate) using integral WPC as per manufacturer instuctions will compacted with V shaped groove of 10mm deep filled with mastic bitumen size of PCC panel with groove shall not exceeding 0.4 sqm complete all as specified and directed.
27S & F PVC door with chowkhats frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supply & fixing in opening as per specification & drawing complete all as specified and directed.
28S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete, all as specified & directed. make - rajshree or equivalent.
29S&F Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.,Size of frame 110X60 MM complete all as specified and as directed.
30S&F Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.,Size of frame 125X60mm complete, as specified, supplied .
31Providing cement concrete type BO 1:2:4 (12.5mm graded aggregate) in cills, steps, seismic and other similar bands plinth coureses string courses lacing courses parapets and railing copings kneelers apex bed plates kerbs. etc.. water troughs and the like including wethering slightly rounded or chamfered angles and throating as directed
32S&F for 35 mm thick flush shutters, solid core construction with block board core and plywood face panels if one face is covered with decorative face veneer with lipping/frame to match, commercial type on both sides and fitted to chowkhats complete all as specified and directed.
33S&F Glazed and skelton shutters, 35 mm thick of Second class hard wood open rebated and prepared to receive glass, gauge etc without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass, etc, sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24(a), chemically treated, complete, all as specified and directed.
34S&F powder coated anodised aluminium alloy sections 3 tier track sliding windows series B of size 92mm x 31.75mm x 1.2mm and shutter section 18mm x 43mm x 1.30mm weight 0.547 kg/m Jindal or equivalent duly fitted with neoprene beading, glazing clips, tinted glass panes 4.80/5.0 mm nominal thickness, stainless steel wire cloth 0.36 mm dia and average width of aperture 1.4 mm, aluminium alloy handles etc including taking down old window in any size and make. complete all as specified and directed.Note : rate shall include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading, locking arrangements, handle etc complete all as specified and directed.
35S&F powder coated anodised aluminium fixed louvered ventilator frame of size 63.5 x 38.1 x 1.01 mm thick or equivalent section fixed in vertical position with aluminium vertical members and half portion to be provided with 4 mm thick pinhead glass and remaining portion to be louvered using 4 mm thick pinhead glass and louvered portion covered with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm incl necessary channel frame work, including rubber gasket and aluminium beading including taking down old ventilator in any size and make complete all as specifiedNote : rates shall include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading etc
36S & F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
37M&L for preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
38M&L for preparation of old steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint complete all as specified and directed.
39S&F Floor door stopper of aluminium alloy body and tongue, anodised, 140 mm with hard drawn steel spring, fixed in floor complete all as specified and directed.
40S & F in repair stainless steel wire cloth 0.36mm dia of wire and avarage width of aperture 1.40mm and fixed with stainless steel wire staple in any type of windows/doors complete all as specified and directed by Engineer-In-Charge.
41M/L two coats of synthetic enameled painting over a coat of pink primer to new wooden surfaces of any description exc 10 cm width or girth complete all as specified and directed.
42M/L two coats of synthetic enameled painting to old wooden surfaces of any description exc 10 cm width or girth complete all as specified and directed.
43S&F Mild Steel Butt hinges, heavy weight, cold rolled, of size 100 mm complete all as specified and directed.
44S&F aluminium anodised, barrel tower bolt of extruded section 150mm long complete all as specified and directed.
45S&F 125 mm long aluminium handle, cast type, anodised complete all as specified and directed.
46S&F aluminium alloy anodised sliding door bolt with hasp staple(bolt type) ,250 mm long,and fixing clip of sheet cast or extruded section or fixing bolt cast aluminium alloy and fixed complete all as specified and directed.
47M&L for screed bed or bedding 15mm thick in CM 1:4 on floor to receive tile complete all as specified and directed.
48S & F Non Skid Ceramic Colour Tiles 7 to 8 mm thick area of each tiles exc 0.06 Sqm but n. exc 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
49S & F Non Skid Ceramic Colour Tiles 7 to 8 mm thick area of each tiles exc 0.18 Sqm but n. exc 0.38 Sqm in floor , skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
50M&L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 20mm screed bed in CM 1:4 complete all as specified and as directed.
51M&L rendering 10 mm thick in CM 1:3 on wall to receive tile complete all as specified and directed.
52M& L glazed ceramic coloured tile in vertical surfaces 300x450x7 mm thick set and jointed in neat cement slurry and poited in white or coloured cement to match
53S&F Coloured Vitrified tiles 10 mm thick (square/rectangular) polished area of each tiles n exc 0.36 sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match in light shade including 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
54S&F Coloured Vitrified tiles 10 mm thick (square/rectangular) polished area of each tiles n exc 0.36 sqm in skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match in light shade including 10 mm thick plaster in CM 1:3 complete all as specified and directed.
55M&L for 75mm thick cement concrete Type C-2 ,1:3:6,( Using 40mm graded aggregate) as in plinth protection , subbase complete all as specified and directed by Engr-in-charge.
56Taking up or down steel tubing and connections including bore of pipe 25 mm complete all as specified and directed.
57Supplying and laying of 25 mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape in any requirement complete to walls and ceilings or laid in floors iincluding all connected brass cpvc fittingsand cutting grooves, filled with CM1:6 complete all as specified and directed.
58Taking up or down steel tubing and connections bore of pipe 20 mm complete all as specified and directed.
59Supplying and laying of 20 mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape complete to walls and ceilings or laid in floors including all connected brass cpvc fittings and cutting grooves, filled with CM1:6 complete all as specified and directed.
60Dismantling exc 500 and n exc 1000 ltr water tank removing to store complete all as specified and as directed.
61S & F in 1000 liters rotaional moulded polyethylene water storage tank, double layered (cylindrical vertical with closed top cover) as per IS-12701-1996 and PTMT 20mm ball valves/ float valve high pressure with epoxy aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum weight 20mm - 210 gms) , hoisted and fixed in position including necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc, complete as specified in SSR Part-I complete all as directed by Engr -in-charge.
62S&F in repairs 20 mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe/upvc pipe complete all as specified and as directed.
63S&F in repair fancy type Bib taps, cast copper alloy 15mm dia with long handle, screwed down, screwed for iron pipe incl female brass threaded adaptor on CPVC pipes complete all as specified and as directed.
64S&F in repair Fancy type Stop valves angle /concealed 15mm bore, cast copper alloy, screwed down, high pre-ssure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed incl female brass threaded adaptor on CPVC pipes complete all as specified and as directed.
65S&F in repair 15mm fancy type Pillar taps, cast copper alloy, with long heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed.
66S&F PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and as directed.
67S&F in repairs PVC(SWR) pipe 110 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, fixed to wall complete all as specified and as directed.
68S & F PVC (SWR) junction single (single T) equal or unequal 110mm bore, with access door complete all as specified and directed by Engr-in-charge.
69S&F in repair PVC (SWR)110 mm bend bore bends with access door any radius complete all as specified and as directed.
70S&F in repairs PVC(SWR) pipe 75 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
71S&F in repairs PVC(SWR) bend any radius, 75 mm dia complete all as specified and as directed.
72S & F PVC (SWR) junction single (single T) equal or unequal 75mm bore, without access door complete all as specified and directed by Engr-in-charge
73M&L for cement concrete 1:2:4 type B-0 (12.5 mm aggregate) sub base of floors , mass concrete complete all as specified and directed by Engr in charge.
74Taking down floor trap/nahani trap of any description any size and making good to disturbed portion with cement concrete type B-1 1:2:4 with water proofing compound complete all as specified and as directed.
75M & L 75mm outlet dia PVC(SWR) floor trap, plain with grating including jointing with solvent cement all as specified and directed.
76S & F in repair vitreous china wash down water closet pan (pedestral pattern) white including fixing to flushing cistern and flush pipe and plastic water closet seat cover black closed pattern with flat bottom and cover and mild steel hinging device complete all as directed.
77S&F in repair vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern ) including provision of cement concrete bedding, connection to trap and to flushing pipe, anti syphonage pipe etc complete making good to floor complete all as specified and as directed.
78Supply and fixing in repair PVC flushing cistern, white, 10ltr capacity with 32mm dia flush pipe any lenth fixed to water closed complete all as specified and as directed.
79S & F in repair Vitreous China wash basin, white, flat back, size 550mm x 400 mm with & including a pair of cast iron brakets embedded in PCC 1:3:6) type C-1 (using 20mm graded stone aggregate), blocks of size 10x7.5x15cm , and 32 mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts,flange end bedded in red lead cement and other end fixed, ( excluding tap ) including PVC Waste coupling of PTMT 32mm dia (half or full threaded) Minimum weight 45gms , washers and Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete as specified and directed by Engr-in-Charge.
80S&F in repairs glass corner shelf 300 mm (with ABS Bracket 300x 600) as selected including removing existing shelf,specified and directed by Eng-in-charge.(Make: Prayag,Jaquar,Cera or equivalent)
81S&F in repair Soap dish of any type (S/S) approximate size 160x160 fixed to plugs with chromium plated brass screws complete all as specified and as directed.
82S&F in repair Brass chromium plated Tublar towel rail 20mm dia D type 60 cm long between flanges complete all as specified and as directed.
83S&F 600 x 450mm bevelled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood & fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed.
84S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
85S&F in repair 125 mm Brass chromium plated shower rose with or without swivel joints, any size, including fixing to steel pipe or union, complete all as specified and directed.
86S&F in repair Vitreous China urinals, bowltype (back or corner wall type),complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets,flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe
87S&F in repair 25mm dia stainless steel curtain rail, cut in required length and size to fit with opening incl fixing on bracket with necessary screws fitted on bracket and decorative nobs on sides with necessary arrangement complete all as specified and as directed by Engr-in-charge.
88S&F in repairs curtain rod side brackets of stainless steel, angular or cantilever type fixed to wall with 02 nos screws on each bracket and fitted screws for fixing curtain rod incl CP/stainless steel carved decorative design plain metal colour nobs with fixing arrangement for curtain rod using a screw complete all as approved and shown by Engr-in-charge.
89M&L for racking of cracks upto 5 mm wide ,preparation and crack filling with ready to use crack fiber reinforced filler /chemical based crack fillers by approved manufacturer and filling as per manufacturer instructions in walls,roofs of any type or size (Make: Pidilite/dr fixit,fosroc, or equivalent) all as specified and directed.
90M&L for racking of cracks exc 5 mm but not exc 10mm wide ,preparation and crack filling with ready to use crack fiber reinforced filler /chemical based crack fillers by approved manufacturer and filling as per manufacturer instructions in walls,roofs of any type or size (Make: Pidilite/dr fixit,fosroc, or equivalent) all as specified and directed.
91Removing the plant/growth of any description size, any location of external surfaces of walls shafts by cutting & remvoing the roots completely spraying the suitable chemical (each plant 100 ML) in the removed portion to avoid re-growth & making good damaged portion to match the existing surfaces by PCC type B0 (1:2:4) 12.5 mm graded aggregate complete all as directed by Engr In Charge (Chemical :- Gramzone/Roundup or equavalent suitable chemical to remove/destroy the plants/roots)
92Removal of all loose/unsound/bad/damaged concrete or plaster existing RCC structure of slab/beams/walls/chajja by using chesel/hammar .Cut and remove unsound reinforcement bars, wires etc without damaging the sound reinforcement . clean loose rust from bars manually with brush . fixing new supplymentary bars if required,either by tying it with existing bars or by welding on it. Applying eppoxy bonding agent and making good with polymer modified plaster/micro concrete as required thickness over a coat of rust removing alkaline primer and match the finishing to the existing surface in ground floor including formwork complete all as specified and directed.
93Supply only of Intergral water proofing compound as per manufactures instruction complete all as specified and as directed.
94M&L for Brickwork with fly ash moudular bricks built in CM (1:4) , straight or curved on plan exc 6m mean radius, complete all as specified and directed.
95S&F in repairs 2 in 1 wall maounted mixer (15 mm bore) with quater turn fittings and provision for overhead shower with 115 mm bend pipe and wall flange, cast copper alloy with capstan heads, fancy type chromium plated (robotic electroplating for everlasting lustrous shine) with 2 water volume adjustment knobs one both side to control the flow of temperature ,screwed down, screwed for iron pipe or for brass ferrule and fixed includng neccesary fittings complete for mixing hot and cold water for tap and shower all as specified and directed by Engr-in-charge. Make:- Hindware ,Cera model or equivalent
96Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in soft/loose soil, complete all as specified and as directed.
97Removing excavated materials to a distance not exceeding 50 m and depositing at a level not exceeding 1.5 m from starting point complete all as specified and as directed.
98Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil, complete all as specified
99Demolition and breaking up sewage drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar (Internal dia of pipe in 150 mm) complete all as specified and as directed by the Engineer-in-Charge.
100M&L Reinforced concrete pipes 150mm ,class NP 2 laid and jointed complete with collars complete all as specified and as directed. (Make Everest/ Hume pipe/Himalya or equvalent)
101M&L for cement concrete bedding and haunching against the sides of pipes after they are laid to 150 mm bore drain pipes in PCC 1:3:6 type C-2 (using 40 mm graded stone aggregates) laid to falls including packing under, and tested, complete all as specified and directed. NOTE :- Pipe shall be measured and paid separately).as in repairs.
102M&L Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing
103Demolition for reinforcement cement concrete of any description in any position complete all as specified and as directed.
104M&L for precast RCC 1:2:4 type B1 using 20mm graded stone aggregate in cover slabs including necessary form work etc for manholes covers set in CM 1:4 complete all as specified and as directed. (reinforcement measured seperately)
105M&L Steel rolling shutters Thickness of laths in mm 1.25 MM, with out ball bearing, as specified including top cover, anchoringrod, hasp and staple and one shop coat of primer; erected in position as indicated,complete: gear operated type with bevel gear box and crank handle complete all as specified and as directed.
106M&L for TMT bars 6 to 8mm dia and over cut to length bent to shape required including bending and binding with and including MS wire annealed not less than 0.9mm dia complete all as specified and as directed.
107Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site.
108Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed.
109Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
110Taking down ceiling fan/ Exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M Jamnagar complete all as specified and as directed.
111M & L for Point wiring for one light point controlled by one, one way switch 5 Amps using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed
112Description all as per item No 111 above but for One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator complete all as specified and directed by Engr-in-Charge.
113Description all as per item No 111 above but for one 3pin 5Amp switch socket outlet point controlled by one switch on same board complete all as specified and directed by Engr-in-Charge.
114Description all as per item No 111 above but for one 3pin 5Amp switch socket outlet point controlled by one switch on independent board complete all as specified and directed by Engr-in-Charge.
115Description all as per item No 111 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly complete all as specified and directed by Engr-in-Charge
116Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and,cutting chases for concealed water,tubing or concealed conduit wiring,,etc., and making good, cutting not,exc 10 cm girth ®(stone massonary) complete all as specified and as directed by Engineer -in-Charge.
117S & F for modular switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified and as directed by Engineer -in-Charge.
118S & F for modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified and as directed by Engineer -in-Charge.
119S & F for modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified and as directed by Engineer -in-Charge.
120S & F for modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified and as directed by Engineer -in-Charge.
121S & F for modular step type fan regulator (BLDC) 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed.
122S & F for ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified and as directed.
123M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit
124S & F for sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
125S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
126S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
127S & F for MCB Tripple pole and neutral rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
128S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
129Taking up/down GI tubing and connections 40mm size of pipes including all fittings complete all as specified and directed.
130S&F tube GI medium grade 25mm dia with all fittings laid in trenches complete all as specified and directed.
131S&F tube GI medium grade 40mm dia with all fittings laid in trenches complete all as specified and directed.
132S&F gun metal valvs with iron wheel head ,screwed both ends for iron pipe and fixed of size 25 mm complete all as specified and directed.
133M&L for filling dry and clean sand in trenches for cable cushioning 8cm below and 15 cm above complete all as specified and directed.
134M&L for un reinforced precast concrete cable cover, LV low voltage type-I flat size 250mmx150mmx40mm complete all as specified and directed.
135M & Lfor XLPE insulated screened PVC bedded galvanised steel strip or wire armoured UG heavy duty electric cable with aluminium conductor 1100 Volts grade cross sectional area of 25 Sqmm 4 core laid in trenches under floor/road/hard standing, along poles etc complete all as specified and as directed by Engineer-in-charge.
136S&F GI pipe light grade 40mm bore for cable protection fixed to poles/along wall/floor/under road/acrossthe drain or nallah including taking down old unservuceable GI pipe complete all as specified and as directed by Engineer-in-charge.
137S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
138S & F for ceiling fan, 230 Volts, 1200 mm sweep with mian air delivary 210 CFM, service value of the fan shall be greater than 6.1 (5 star rated) as per BIS with blades, down rod & other necessary accessories with brushless direct current motor (BLDC) with out remote system and electrical connections from ceiling rose to fan teriminal complete all as specified and as directed
139S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed.
140S & F for LED tube light fitting 2 feet x 10 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and as directed.
141S & F for energy efficient exhaust fan of 230 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed. (Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be included in overall rate quoted).
142M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion. Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.
143Supply, Installation, Testing & Commissioning (SITC) of 18 Watt LED Square Surface Mounted Light Fitting, decorative indoor type, comprising pressure die-cast aluminium/CRCA housing with white polyester powder-coated finish, opal polycarbonate diffuser, high-efficiency SMD LEDs, integrated constant current electronic driver, suitable for 220–240V AC, 50Hz supply, with system efficacy not less than 100 lm/W, Power Factor ≥0.95, CRI ≥80, CCT 4000K (or as specified), THD <10%, average life 50,000 burning hours (L70), IP20 protection, complete with all mounting accessories, fixing hardware, internal wiring, testing and commissioning, complete as required.
144S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25/35 watts with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge.

AI Tender Summary

OUR REF NO 57870873
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 03-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Rep Of Bldg No P-461(Kote & Qtr Gd) Of Certain Units In Jamnagar Mil Stn Under Ge(A) Jamnagar.
Basic Detail
Tender No 8301/E8
Bidding Type Tender
Location
City Jamnagar
State Gujarat
Key Dates
Publish Date 27 Oct 2026
Submission Date 03 Nov 2026
Open Date 05 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 97000
Exemption Available
Document List
439e72e9-b63f-46d9-b78f-172f265e80da.html
BOQ_888422.xls
tender8301.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 27, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 03, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 4 days
Nov 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Nov 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.